SDR 2001UALA00536Shear Tie · corrodedBS 368 STRINGERS 37L TO 38L SHEAR TIE CORRODED. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR IN ACCORDANCE WITH BAC DRAWING 141T1221.SDR 2001UALA00532Shear Tie · corrodedBS STRINGER 35L TO 37L SHEAR TIE CORRODED. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR IN ACCORDANCE WITH BAC DRAWING 146T8511 AND SRM 51-40-02.SDR 2001UALA00531Shear Tie · corrodedSTATION 355 STRINGERS 35L TO 34L SHEAR TIE CORRODED. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR IN ACCORDANCE WITH BAC DRAWING 141T1221 AND SRM 51-40-02.SDR 2001UALA00529Door Frame · corrodedBULK PIT DOOR SILL UPPER CHORD CORRODED ON INBOARD LEG STATION 1417 TO 1424 ABOVE STRINGERS 32L TO 33L. MAJOR REPAIR ACCOMPLISHEDFABRICATED AND INSTALLED REPAIR IN ACCORDANCE WITH BAC DRAWING 146T8511 AND SRM 51-40-02.SDR MWEA010595Shear Tie · corrodedFOUND CORROSION ON SKIN SPLICE DOUBLER AND FORWARD SIDE OF RIGHT LAV FLOORBEAM AT STATION 996. REMOVED SHEAR TIE, LOCATED, DRILLED, AND INSTALLED NEW SHEAR TIE.SDR MWEA010584Fitting · corrodedFORWARD CARGO DOOR JAMB, FOUND T-FITTING CORRODED INSIDE BOX STRUCTURE TOP OF DOOR JAMB ABOVE AFT STOP FITTING. REMOVED BRACKET, FABRICATED, DRILLED, AND INSTALLED NEW FITTING.SDR MWEA010583Fitting · corrodedFORWARD CARGO DOOR JAMB TEE FITTING WAS EXFOLIATED INSIDE BOX STRUCTURE TOP OF DOOR JAMB. REMOVED FITTING, FABRICATED, AND INSTALLED NEW TEE FITTING.SDR RRXA10988Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO LONGERON AT STA 605 AND L35L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-2 FIG.10,SDR RRXA10987Longeron · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO LONGERON AT STA 605 AND L35R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-20D, 53-2-0 FSDR LR7A01025Pressure Panel · corrodedDURING SCHEDULED C3 INSPECTION PER JOB CARD HSP53126 FOUND FS 477 - 517 PRESSURE FAIRING CORRODED AT RT CWS 23.5 TO 61.5, WL 276 TO WL 282. REPAIRED IAW LAC MEA 382-53-01-013.SDR CALA0100369Shear Tie · corrodedINSPECTION FOUND SHEAR TIE ON AFT SIDE OF FRAME IN AFT PIT CORRODED AT STA 1155 BETWEEN LONGERON 30 AND 29R. A T-ANGLE WAS INSTALLED IAW 51-10-4, 51-10-3, AND 51-30-5.SDR RRXA10986Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO BATHTUB FITTING AT STA 1180 AND L32L TO L33L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRSDR RRXA10985Fitting · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO BANNANA FITTING AT STA 1200 AND L27L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-1-21, 51-1SDR RRXA10984Longeron · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO LONGERON AT STA 1766 AFT OF BULKHEAD AND HOLE#60 AND L17R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IASDR RRXA10981Fitting · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO FITTING AT STA 1140 AND L35R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 53-1-0, 51-1-20D ANDSDR DHL2001705512Pressure Panel · crackedAT C-CHECK- NOSE GEAR WHEEL WELL RT SIDEWALL PANEL IS CRACKED BS 285.6 WL 158. CRACK RUNNING ALONG FAST ROWS-2 PLACES. FABRICATED EXTERNAL DOUBLER REPAIR AT NOSE WW RT SIDEWALL FROM BS 250 TO 294.5 AS PER B727 S/B 53-0065- MAT USED 2024 T3 .050 38 X 34 INCH LSDR DHL2001705510Pressure Panel · crackedC-CHECK- NLG WW RT SIDEWALL PANEL IS CRACKED BS 285.6 WL 158. CRACK RUNNING ALONG FASTENER ROWS-2 PLACES. INSTALLED DOUBLER REPAIR AT NLG WW RT SIDE FABRICATED EXTERNAL DOUBLER REPAIR AT NOSE WW RT SIDEWALL FROM BS 250 TO 294.5 AS PER B727 S/B 53-0065- MAT USESDR DHL2001705543Pressure Panel · crackedC-CHECK- NLG WW RT SIDEWALL PANEL CRACKED BS 263.5 FASTNENER ROW UPPER OF AFT ACCESS DOOR. CUT OUT DAMAGED SECTION AND INSTALLED REPAIR.SDR DHL2001705524Pressure Panel · crackedC-CHECK- NLG WW TOP CEILLING PANEL IS CRACKED AROUND FASTENER ROW AT BS285.5 RBL 3. REMOVED DAMAGED AREA AND INSTALLED DOUBLER REPAIR & FILLERSDR RRXA10979Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO BATHTUB FITTING AT STA 1160 AND L32L TO L35L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECIVED PART AND INSTALLED IAW DC-8 SRM 5SDR RRXA10978LongeronDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO LONGERON AT STA 8-70 AND L27R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-1-0, 51-1-SDR RRXA10975Intercostal · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO LOWER CORD ON INTERCOSTAL AT STA 1460 AND L34R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SDR RRXA10973Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO LONGERON AT STA 35-55 AND L27R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW 53-3-3 FIG.2 AND 51-1SDR RRXA10972Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO LONGERON 27R END FITTING AT STA 70 TO 80, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRMSDR SWAA011134Shear Tie · crackedDURING SCHEDULED D CHECK, FOUND SHEAR TIE CRACKED AT BS 360, BETWEEN STR 14L & 15L. R&R SHEAR TIE PER SRM & BAC DWG.SDR UPS01435670Door Frame · crackedINSPECTION TYPE:C3 L3 DR CUTOUT FWD LOWER CORNER REVEAL CRACKED AS MARKED. L3 DR CUTOUT FWD LOWER CORNER REVEAL REPLACED AS PER AS PER SRM 51-10-01.SDR UPS01435666Door Frame · crackedINSPECTION TYPE:C3 R3 DR CUTOUT FWD LOWER CORNER REVEAL CRACKED AS MARKED. R3 DR CUTOUT FWD LOWER CORNER REVEAL REPLACED AS PER SRM 51-10-01.SDR UPS01435640Shear Tie · crackedINSPECTION TYPE:C3 CABIN - SHEAR TIE FOUND CRACK AT STA 1800 S-4R TO S-5R. SHEAR TIE REPLACED AS PER SRM 51-10-01.SDR RRXA10969Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE LOWER FRAME AT FS 1440 AND L34R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SRM 53-SDR EISA20010085Stringer · damagedSTRINGER 25 RIGHT DAMAGED BETWEEN STATION 1100 AND 1140. CORRECTIVE ACTION: REMOVED DAMAGED SECTION OF STRINGER, FABRICATED REPAIR SECTIONS AND SPLICES, IAW SRM 53-10-3, 51-10-2, 53-10-3 FIG 1.SDR RRXA10962Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE FLOOR PANEL SUPPORT FITTING AT STA 1220 AND L35R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////OPEN/////SDR RRXA10951Channel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE UNDER STRAP ON LONGERON 34R AT STA 1400 TO 1420, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLSDR EISA20010087Skin · damagedDAMAGED TO RIGHT SIDE OF AIRCRAFT AT STATION 1100-1135 BETWEEN STRINGER 24 & 25R DUE TO BAGGAGE CART BLOWN INTO AIRCRAFT. CORRECTIVE ACTION: CUT OUT DAMAGED AREA PER E.O. #01-112, REV A FABRICATED FILLER, DOUBLER, SHIMS. TREATED PRIMED AND INSTALLED REPAIR PERSDR AALA20010930Door Frame · crackedTUL - FOUND DOOR JAMB WEB CRACKED AT STATION 208, LONGERON 15L. FABRICATED AND INSTALLED REPAIR STRAP PER AARD 53-10-00-11. (M)SDR UPS01435726Door Frame · crackedINSPECTION TYPE: C3 CRACK REVEALED ON THE BOTTOM FORWARD CORNER VERTICAL BEAM OF DOOR 5L, DOOR 5L FWD CORNER VERTICAL BEAM REPAIRED AS PER SRM 52-10-02 FIG 10SDR UPS01435665Shear Tie · crackedINSPECTION TYPE:C3 CABIN - SHEAR TIE FOUND CRACK AT STA 1920 S-4R TO S-5R. SHEAR TIE REPLACED AS PER SRM 51-10-01.SDR UPS01435664Shear Tie · crackedINSPECTION TYPE: C3 CABIN - SHEAR TIE FOUND CRACK AT STA 1820 S-4R TO S-5R. CRACKED SHEAR TIE REPLACED PER SRM 51-10-01.SDR RRXA11019Shear Tie · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO SHEAR TIE AT STA 1420 AND L34R AND L36R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-20D, 51-3-0.SDR RRXA10944Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK BETWEEN LONBERON 28L AND 29L AT STA 1160, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// RECEIVED PART AND INSTALLED IAW DC-8 SRM 53-2-0, FIG 2D.SDR AALA20010787Door Frame · corrodedTUL - FOUND CORROSION ON LOWER FORWARD CORNER OF DOOR JAMB FRAME AROUND NUT PLATE. REMOVED CORROSION PER SRM 51-21-01, VOL 2. INSTALLED REPAIR PER SRM 53-50-00 FIG 23. (M)SDR 2001UALA00497Crease Beam · corrodedCREASE BEAM WEB STA 1076 STR 17R HAS EXCESSIVE MATERIAL LOSS. REPLACED CREASE BEAM PER SRM.SDR 2001UALA00382Shear Tie · corrodedBETWEEN STRINGERS 38R - 39R SHEAR TIE CORRODED. MAJOR REPAIR ACCOMPLISHEDFABRICATED AND INSTALLED REPAIR IN ACCORDANCE WITH SRM 51-40-02 AND BAC DRAWING 140T2102.SDR 2001UALA00498Shear Tie · corrodedAFT CARGO PIT AT BS 1241 BETWEEN STRINGERS 37L TP 39L, SHEAR TIE CORRODED. MAJOR REPAIR ACCOMPLISHED REPLACED SHEAR TIE PER BAC DRAWING 140T2102 AND INSTALLED PER SRM 51-40-02.SDR 2001UALA00495Shear Tie · corrodedBS 1439 STRINGER 38R TO 39R SHEAR TIE CORRODED. MAJOR REPAIR ACCOMPLISHED FABRICATED AND INSTALLED REPAIR IN ACCORDANCE WITH BAC DRAWING 140T2102 AND SRM 51-40-02.SDR 2001UALA00480Shear Tie · corrodedFORWARD PIT BS 742 STRINGERS 38R TO 39R SHEAR TIE CORRODED. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED FABRICATED AND INSTALLED NEW SHEAR TIE IN ACCORDANCE WITH BAC DRAWING 140T2102 AND SRM 51-40-02.SDR 2001UALA00489Shear Tie · corrodedBS 1439 STRINGERS 39L TO 39R SHEAR TIE CORRODED. MAJOR REPAIR ACCOMPLISHED FABRACATED AND INSTALLED REPAIR IN ACCORDANCE WITH BAC DRAWING 140T2102 AND SRM 51-40-02.SDR 2001UALA00488Shear Tie · corrodedBS 1373 STRINGERS 36L TO 37L SHEAR TIE CORRODED. MAJOR REPAIR ACCOMPLISHED FABRACATED AND INSTALLED REPAIR IN ACCORDANCE WITH BAC DRAWING 140T2102 ANDSRM 51-40-02.SDR 2001UALA00487Shear Tie · corrodedBS 1417 STRINGERS 39L TO 39R SHEAR TIE CORRODED. MAJOR REPAIR ACCOMPLISHED FABRACATED AND INSTALLED SHEAR TIE IN ACCORDANCE WITH BAC DRAWING 140T2102 ANDSRM 51-40-02.SDR 2001UALA00486Shear Tie · corrodedBS 1417 STRINGERS 38R TO 39R SHEAR TIE CIRRIDED. MAJOR REPAIR ACCOMPLISHEDFABRACATED AND INSTALLED REPAIR IN ACCORDANCE WITH BAC DRAWING 140T2102 ANDSRM 51-40-02.SDR 2001UALA00485Shear Tie · corrodedBS 1131 STRINGERS 34R TO 35R SHEAR TIE CORRODED. MAJOR REPAIR ACCOMPLISHED FABRACATED AND INSTALLED REPAIR IN ACCORDANCE WITH BAC DRAWING 140T2102 ANDSRM 51-40-02.
Back to JASC 5310