JASC 5311
Service difficulty reports · 61,540
Reports filed under 5311 · Fuselage Main, Frame, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2022053103758Stop Fitting · crackedSHIP 3114 - CRACK INDICATION FOUND ON FRAME 68 LH DOOR STOP FITTING 1 HOLE 4 LOWER INBOARD. CORRECTIVE ACTION: PERFORMED REPAIR ON FRAME 68 LH DOOR STOP FITTING 1 HOLE 4 LOWER INBOARD AS PER A319 SRM 53-41-12(2253132)SDR DALA2022053103757Stop Fitting · crackedSHIP 3114 - CRACK INDICATION FOUND ON FRAME 68 RH DOOR STOP FITTING 1 HOLE 4 LOWER INBOARD. CORRECTIVE ACTION: PERFORMED REPAIR ON FRAME 68 RH DOOR STOP FITTING 1 HOLE 4 LOWER INBOARD AS PER A319 SRM 53-41-12.(2253128)SDR DALA2022053103756Stop Fitting · crackedSHIP 3114 - CRACK INDICATION FOUND ON FRAME 68 LH DOOR STOP FITTING 1 HOLE 1 UPPER OUTBOARD. CORRECTIVE ACTION: ERFORMED REPAIR ON FRAME 68 LH DOOR STOP FITTING 1 HOLE 1 UPPER OUTBOARD AS PER A319 SRM 53-41-12(2252935)SDR CALA2022053001370Fitting · gougedGOUGE ON WINDSHIELD LWR FITTING & SPLICE. UPON REMOVAL OF FOWARD SKIN PANEL AND FALSE FRAME, GOUGE FOUND ON WINDSHIELD LOWER FITTING AND SPLICE. EVALUATION IS REQUIRED. AS NOTED ON LTPR NR# 5001142616-0060. REPAIRED THE LWR FITTING & SPLICE GOUGES AT LH WINDSHSDR CALA2022053001374Window Frame · crackedWINDSHIELD FRAME LH CONTINUITY FITTING FOUND CRACKED WINDSHIELD FRAME LH CONTINUITY FITTING REPAIRED PER ECRA 5311- 02813 CAT "A" PERMENENT REPAIR RII REQ CW U 247351SDR CALA2022053001373Fitting · crackedCENTER POST LH CONTINUITY FTG FOUND CRACKED ON UPPER CORNER SEQ: 1543, LTPR NR# 5001143616-0050. REMOVED AND REPLACED BULKHEAD STIFFENER AT FR1 AFT SIDE PER SRM 51-72-11-911-001 RII REQS ARE CW U247351SDR SWIA202266109None · corroded*CORROSION ON FS280 BEAM BETWEEN RBL9.00 AND LBL9.00 (MARKED) (C-CHECK RO 7/9/2022) REMOVED DAMAGED FS 280 BEAM AND REPLACED WITH NEW FS 280 BEAM BETWEEN RBL 9.00 AND LBL 9.00 REF. CRJ200 SRM 51-42-06-00 AND CRJ200 SRM 51-42-21-00 AND REO 601R-53-11-926SDR SWIA202266108None · corroded*MULTIPLE SPOTS OF CORROSION NOTED ON FLOOR BEAM SUPPORT EXTRUSION AT LBL9 BETWEEN FS409.00+128-FS409.00 (MARKED) (C-CHECK RO 7/9/2022) REPLACED FLOOR BEAM SUPPORT EXTRUSION AT LBL9 BETWEEN FS409.00 TO FS409.00+128 PER REO 601R-53-31-1231 REV-- DATED 20SDR SWIA202266107None · corroded*MULTIPLE SPOTS OF CORROSION NOTED ON FLOOR BEAM SUPPORT EXTRUSION AT RBL9 BETWEEN FS409.00+128-FS409.00 (MARKED) (C-CHECK RO 7/9/2022) REPLACED FLOOR BEAM SUPPORT EXTRUSION AT RBL9 BETWEEN FS409.00+128 TO FS409.00 PER REO 601R-53-31-1230 REV-- DATED 20SDR SWIA202266101None · corrodedPRESSURE FLOOR SUPPORT BEAM RBL9 HAS SPOTS OF CORROSION ALONG FLOOR SILL FROM FS409+128 TO FS559.0 (MARKED) (C-CHECK RO 7/9/2022) REMOVED CORROSION FROM FLOOR SUPPORT BEAM RBL9 FROM FS409+128 TO FS559.00 PER REO 601R-53-41-3035 REV-- DATED 2022-06-13 ASDR REXA2022071201517Frame · corrodedCORROSION FOUND AT FRAME AT FS 942.00, BETWEEN STGR 26L-25R. REMOVED & REPLACED LOWER FRAME SECTOR IAW ENDEAVOR AIR EA#CRJ953 - 13823, REV- IR, 6/9/2022SDR SWIA202265948None · corrodedCORRODED SHEAR CLIP FR88 STGR 28R-29R AS MARKED (C-CHECK RO 6/16/2022) REMOVED AND REPLACED SHEAR CLIP AT FR88 STGR28R-29R IAW SRM 51-40-08. REFERENCE CARD FOR WORK PERFORMED.SDR SWIA202265947None · corrodedCORRODED SHEAR CLIP FR88 STGR 28R-27R AS MARKED (C-CHECK RO 6/16/2022) REMOVED AND REPLACE CORRODED SHEAR CLIP AT FR88 STGR 28R-27R IAW SRM 51-40-08. RESTORED SURFACE PROTECTION IAW SRM 51-23-06. REFERENCE CARD FOR WORK PERFORMED. NO CHANGE TO MRB REQUISDR SWIA202265946None · corrodedCORRODED SHEAR CLIP FR87 STGR 28R-27R AS MARKED (C-CHECK RO 6/16/2022) REMOVED AND REPLACED CORRODED SHEAR CLIP AT FR 87 STGR 28R-27R IAW SRM 51-40-08. REFERENCE CARD FOR WORK PERFORMED.SDR SWIA202265945None · corrodedCORRODED SHEAR CLIP FR87 STGR 28R-29R AS MARKED (C-CHECK RO 6/16/2022) REMOVED AND REPLACED CORRODED SHEAR CLIP AT FR87 STGR 28R-29R IAW SRM 51-40-08. REFERENCE CARD FOR WORK PERFORMED.SDR SWIA202265944None · corrodedCORRODED SHEAR CLIP FR85 STGR 28R-27R AS MARKED (C-CHECK RO 6/16/2022) REMOVED AND REPLACED SHEAR CLIP FR 85 STGR 28R-27R REF SRM 51-40-08. RESTORED SURFACE PROTECTION REF SRM 51-23-06. RESTORED CIC IAW CPM 51-25-00-910-001-A. SEE CONTINUATION CARD FOR SDR AALA202206023869Window Frame · elongatedAIRCRAFT IN BASE MAINTENANCE: CAPTAIN'S SIDE EYEBROW WINDOW FRAME LOCATED AT BS 220.8 HAS ELONGATED HOLES. REPAIRED FRAME PER EA 336065.SDR AALA202207062335Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FRAME FOOT COUPLING AT FR 43 BETWEEN S21R AND S22R. REPLACED FRAME PER EA 336571.SDR DALA2022053103753Stop Fitting · crackedSHIP 3102 - CRACK INDICATION FOUND ON DOOR STOP FITTING #1 HOLE 4 ( I/B, LOWER POSITION)LH SIDE FRAME 68 AT 9 O CLOCK. CORRECTIVE ACTION: PERFORMED REPAIR ON DOOR STOP FITTING #1 LH SIDE FRAME 68 AS PER A319 SRM 53-41-12.(2250294)SDR SWAA2022072011057Frame · crackedCRACK FRAME BS312 UPPER CORNER CUT OUT WL288 AT PASSENGER CABIN 2022-274472 / [01] FOULT RESOLVED ON FOULT: TTG8Q00CRX9T;[02] TASK CARD COMPLETE.;[03] EDITED STEP 1<BR>REPAIRED FRAME BS312 UPPER CORNER CUT OUT WL288 AT PASSENGER CABIN IAW EA# M-22-153-01244 RESDR SWAA2022072011060Frame · crackedCRACK STUD FRAME LOCATED BS294 AND BETWEEN STR8R TO STR9R AT PASSENGER CABIN 2022-274479 / [01] REPLACED STUD FRAME LOCATED BS294 AND BETWEEN STR8R TO STR9R AT PASSENGER CABIN IAW B737-700 SRM 51-40-02; SRM 51-10-02 PARAGRAPH 9 AND DWG 141A8370 SHEET 9 REV:-. SDR SWAA2022072011061Frame · crackedCRACK STUD FRAME LOCATED BS294 AT LEVEL STR17R AT PASSENGER CABIN 2022-274481 / [01] REPLACED STUD FRAME LOCATED BS294 AT LEVEL STR17R AT PASSENGER CABIN IAW B737-700 SRM 51-40-02; SRM 51-10-02 PARAGRAPH 9 AND DWG 141A8370 SHEET 9 REV:-. SEE INDIVIDUAL SIGNOFFSDR DALA2022052603653None · noneSHIP 666 AFTER FASTENERS REMOVAL, CRACK WAS FOUND ON ANGLE BTW STA 1640 AND S-14R. CORRECTIVE ACTION: SUMMARY OF NRC 00184: CRACK ANGLE WAS REPLACED PER B757-200 SRM. (2248930)SDR DALA2022052503628None · noneSHIP 3102 - CRACK INDICATION FOUND ON HOLE D AT FRAME 16 DOUBLE JOGGLE AREA AT LEVEL OF THE DOOR STOP 7. CORRECTIVE ACTION: COMPLIED WITH ER/A #598915-14AD REV ORIGINAL.(2248727)SDR DALA2022052503626None · noneSHIP 3102 - CRACK WEB LOCATED BETWEEN FR10 TO FR11 AND Y765 FLOOR STRUCTURE IN COCKPIT. CORRECTIVE ACTION: REPLACED WEB LOCATED BETWEEN FR10 TO FR11 AND Y765 FLOOR STRUCTURE IN COCKPIT AS PER SRM 51-42-11.(2248737)SDR CALA2022052501334Frame · cracked(AD2022-02-11) DURING ROTO PROBE OF RH FR16 #7 DOOR STOP CRACK I NDICATION NOTED IN HOLES #1 AND #3 FRAME AND INTERCOASTAL LAYERS REPAIR BEFORE NEXT FLIGHT.()SDR CALA2022052501333Frame · cracked(AD2022-02-11) DURING ROTO PROBE OF LH FR16 #7 DOOR STOP CRACK INDICATION NOTED IN HOLE #1 FRAME AND INTERCOASTAL LAYERS.()SDR IXXA2022052408Floor Support · corrodedCORROSION STA1283, RBL28 BALLMAT SUPPORTSDR AALA202207067269Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FRAME AT FR 68 AND S22L AT DOOR STOP FITTING #1 FASTENER HOLE. REPAIRED FRAME PER SRM 53-41-12-300-011.SDR AALA202207063538Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FRAME AT FR 68 AND S22R AT DOOR STOP FITTING #1 FASTENER HOLE. REPAIRED FRAME PER SRM 53-41-12-300-011.SDR SWAA2022070110586Stub Frame · crackedCRACK FRAME STUB LOCATED ON BS 294.5 AT FWD UPPER CORNER OF R1 DOOR CUT OUT AT PASSENGER CABIN 2022-265933 / [01] INSTALLED STUB FRAME; LOCATED ON BS 294.5 AT FWD UPPER CORNER OF R1 DOOR CUT OUT AT PASSENGER CABIN IAW B737-700 SRM 51-40-02; B737-700 SRM 51-10-SDR P5CA2022051800118Structure · corrodedCORROSION ON INNER CHORD OF LOWER FRAME SEGMENT AT STA 1219 BETWEEN LBL 42 / RBL 39 AND WL 124.43 (AFT CARGO COMPT. FLOOR STRUCTURE)(IT WAS REPLACED THE AFFECTED PART)SDR R61A2022052300363Shear Angle · corrodedWHILE ACFT IN HEAVY CHECK, MAINTENANCE FOUND CORROSION ON THE SHEAR CLIPS ON FR 83, 84, 85 AND 86 AT STR 27R-28R. REMOVED AND REPLACED SHEAR CLIPS ON FR 83,84,85 AND 86 AT STR 27R-28R. IAW EMB SRM 51-40-08. ACFT REMAINS IN HEAVY CHECK.SDR SWIA202265935None · corrodedCORROSION AROUND SCREW HOLE L/H TRACK AT FR 19 (C-CHECK RO 6/14/2022) REMOVED CORROSION FROM AROUND SCREW HOLE L/H TRACK AT FR 19 BY CUTOUT, FILLER AND DOUBLER FABRICATION AND INSTALLATION REF SRM 53-10-10/REPAIR01P. REFERENCE CARD FOR WORK PERFORMED. RSDR SWIA202265934None · corrodedCROSS BEAM CORRODED FR 17 CENTER BETWEEN L/H AND R/H TRACK BEAMS (C-CHECK RO 6/14/2022) REMOVED CORROSION ON FR 17 CROSS BEAM BETWEEN L/H AND R/H TRACK BEAMS BY PERFORMING CUTOUT, FILLER AND DOUBLER INSTALLATION REF SRM 53-00-10/REPAIR03P. REPAIR DOUBLESDR AALA202207205234Window Post · crackedAIRCRAFT IN BASE MAINTENANCE FLIGHT DECK WINDSHIELD CENTER POST RIGHT HAND LOWER WINDSHIELD FRAME CRACKED AT FR 2 BETWEEN Y0 AND -Y511. REPLACED WINDSHIELD FRAME PER EA 336637 AND EO 5319Y017-003.SDR AALA202207207798Window Post · crackedAIRCRAFT IN BASE MAINTENANCE FLIGHT DECK WINDSHIELD CENTER POST LEFT HAND LOWER WINDSHIELD FRAME CRACKED AT FR 2 BETWEEN Y0 AND +Y511. REPLACED WINDSHIELD FRAME PER EA 336637 AND EO 5319Y017-003.SDR AALA202207143168None · crackedAIRCRAFT IN BASE MAINTENANCE: FLIGHT DECK CENTER WINDSHIELD RIGHT HAND LATERAL WINDSHIELD FRAME CRACKED AT FR 3 AND Y0. REPLACED WINDSHIELD FRAME PER EA 336637 AND EO 5319Y017-004.SDR SWAA2022070110051Frame · crackedCRACK FRAME BS 312 BTW STR 5L TO STR 6L AT PASSENGER CABIN 2022-265837 / [01] REPAIRED FRAME BS 312 BTW STR 5L TO STR 6L AT PASSENGER CABIN IAW EA M-22-153-01244; FAULT TTG8Q00CRYNN;[02] CORRECTED ITEM 1<BR>REPAIRED FRAME BS 312 BTW STR 5L TO STR 6L AT PASSENGSDR SWAA2022061709821Frame · crackedMAIN CABIN L/H STA 312 STR 4 FRAME CRACKED / [01] PERFORMED HFEC INSP ON MAIN CABIN L/H STA 312 STR 4. IAW B 737 NDT PART 6 51-00-00 PROCE 23. TOOL NORTEC 600. BC 166316. CALIB DUE 10-8-22. CONFIRMED CRACK; LENGTH 0.313'.;[02] CUTOUT DAMAGED AREA AT FRAME STA SDR SWIA202265932None · corrodedSHEAR CLIP AT FRAME 88 BETWEEN STRINGERS 26R-27R CORRODED (C-CHECK RO 6/14/2022) REMOVED AND REPLACED SHEAR CLIP FR 88 STRINGER 26R-27R REF EMB SRM 51-40-08. RESTORED SURFACE PROTECTION REF SRM 51-23-04, 51-23-05, 51-23-06. APPLIED C.I.C. REF CPM 51-25-SDR DALA2022052003479None · none(LOG 2242882) DURING INSPECTION FOUND CORROSION AT LOWER WEB STA 463 APROX. OF FWD CARGO DOOR CUTOUT STRUCTURE. LOWER WEB STA 463 APROX. OF FWD CARGO DOOR CUTOUT STRUCTURE.. (C1). WAS REPLACED PER B737-800 SRM 51-40-02-0G.SDR AALA202207277202Window Post · crackedAIRCRAFT IN BASE MAINTENANCE: FLIGHT DECK RIGHT HAND CENTER LATERAL WINDSHIELD / WINDOW POST CRACKED AT FR 4 AND -Y511. REPLACED WINDSHIELD / WINDOW POST PER EO 5319Y17-004 AND EA 336815.SDR CALA2022052001292Window Frame · corrodedINTERIM REPAIR TO L1 WINDOW FRAME WAS ACCOMPLISH PER ECRA 5311-02812 PART 1. REFERENCE FLEETCYCLE NON-ROUTINE 9809922. THE INSPECTION REQUIREMENTS PER ECRA 5311-02812 PART 1 STEP G.2. INITIATE DIP FOR PLANNING TO CONTACT ENGINEERING AFTER 43,000 TOTAL FLIGHT SDR CALA2022052001291Window Frame · crackedINTERIM REPAIR TO R1 WINDOW FRAME WAS ACCOMPLISHED PER ECRA 5311-02811 PART 1, INSPECTION REQUIREMENTS ARE STATED IN PART 2. REFERENCE FLEET CYCLE NON-ROUTINE 9809923. OR BEFORE THE AIRCRAFT REACHES 50,000 TOTAL AIRCRAFT FLIGHT PART 2, SECTION A AT INTERVALS NSDR 2022FA0000263None · corrodedTHE FRAME OF THIS PLANE IS SEVERELY CORRODED. THERE IS VISUAL DAMAGE TO MULTIPLE SURFACES INCLUDING THE SKIN AND THE SPARS. IT ALSO HAS MULTIPLE CABLES THAT ARE SEVERELY CORRODED. AN A&P DEEMED IT “AIRWORTHY” BUT NONE OF THESE ISSUES HAVE BEEN REMEDIED. I GROUSDR SWIA202266080None · corroded2 EA CLEATS @ FS339.963 AND LOWER CHANNEL HAVE INTERGRANULAR CORROSION (C-CHECK RO 7/8/2022) REMOVED 2 EA CLEATS @ FS339.963 AND LOWER CHANNEL REF CRJ700 SRM51-42-06-001-001-A01 / AND INSTALLED NEW (2EA) CLEATS @ FS339.963 AND LOWER CHANNEL REF: CRJ-7SDR AALA202206108047Frame · crackedAIRCRAFT IN BASE MAINTENANCE: FRAME FOOT COUPLING CRACKED AT FR 43 BETWEEN S21R AND S22R. REPLACED FRAME AND FITTING PER EA 336347. SEE PREVIOUSLY SUBMITTED REPORTS AALA202206081443 (FRAME) AND AALA202206081314 (FITTING).SDR DALA2022052003474None · none(LOG 2240647) DURING INSPECTION FOUND CORROSION AT LOWER SILL STRUCTURE R1 DOOR BTW STA 294.5 TO STA 360 RBL 58 FWD WET AREA. CORROSION LEVEL 2 LOWER SILL WAS REPLACED PER B737-800 SRM 51-40-02-0G PAR.7 AND SRM 51-40-04-0G.SDR DALA2022051903448None · noneSHIP 3162 - CORROSION STRINGER 41R BTW FR 63 TO FR 64 IN AFT CARGO COMPARTMENT. CORRECTIVE ACTION: REPLACED STRINGER 41 RH AND FASTENERS LOC BTW FR64 TO FR65 ASPER A319 SRM 51-72-11.(2240974)
Back to JASC 5311