JASC 5311
Service difficulty reports · 61,540
Reports filed under 5311 · Fuselage Main, Frame, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2020111103671Frame · crackedCRACK INDICATION ON FRAME 20 LT ON UPPER INBOARD HOLE COMMON TO DOOR STOP FITTING 7. CRACK ON FRAME WEB LAYER AT FWD GALLEY AREA. CORRECTIVE ACTION: PERFORMED REPAIR INSTRUCTION ON FRAME 20 LT ON UPPER INBOARD HOLE COMMON TO DOOR STOP FITTING 7, AS PER PRI 5SDR SWIA202054995Frame · crackedFS 333 IS CRACKED AT TOOLING HOLE BETWEEN STGR 0 AND STGR 1L. C-CHECK RO 12/30/2020. REMOVED AND REPALCED FRAME SECTOR AT FS 333.00, IAW CRJ 200 SRMS. MAJOR REPAIR TASK CARD & FORM M337 COMLETED AND ATTACHED. NO WEIGHT CHANGE TO BE MADE, WAS A PART FOR PARSDR SWAA2020113032671Frame · crackedCRACK INDICATION FRAME LOCATED BS 905 BETWEEN STR 8R TO 9R AT PASSENGER CABIN. PERFORMED PERMANENT REPAIR ON FRAME BS 907 BETWEEN S8R TO S9R, IAW E/A SWA NR 20-153-02362 REV IR AND AEROMAN EA NR 53-0762-20 REVISION NR 0 AND PART NR 1 DUE TO NOT FOUND ALLOWABLSDR SWAA2020113030351Frame · crackedCRACK INDICATION ON FRAME LOCATED BS 787 BETWEEN STR 8L TO SRT 9L AT PASSENGER CABIN. PERFORMED PERMANENT REPAIR ON FRAME LOCATED BS 787 BETWEEN STR 8L TO STR 9L AT PASSENGER CABIN, IAW EA N 1-A53-12114 REV 5.SDR SWAA2020113030350Frame · crackedCRACK INDICATION FRAME LOCATED BS 827 BETWEEN STR 8L TO STR 9L AT PASSENGER CABIN. PERFORMED PERMANENT REPAIR ON FRAME LOCATED BS 827 BETWEEN STR 8L TO STR 9L AT PASSENGER CABIN, IAW EA N.1-A53-12114 REV 5.SDR SWAA2020113030348Frame · crackedCRACK INDICATION FRAME LOCATED BS 500A BETWEEN STR 8L TO STR 9L AT PASSENGER CABIN. PERFORMED PERMANENT REPAIR ON FRAME LOCATED BS 500A BETWEEN 5-8L TO 5-9L ON PASSENGER CABIN, IAW EA N 1-A53- 12114 REV 5.SDR SWAA2020113030347Frame · crackedCRACK INDICATION FRAME LOCATED BS 480 BETWEEN STR 8L TO STR 9L AT PASSENGER CABIN. PERFORMED PERMANENT REPAIR ON FRAME LOCATED BS 480 BETWEEN STR 8L TO STR 9L ON PASSENGER CABIN, IAW EA N.1-A53-12114 REV 5.SDR SWAA2020113030346Frame · crackedCRACK INDICATION FRAME LOCATED BS 400 BETWEEN STR 8L TO STR 9L AT PASSENGER CABIN. PERFORMED PERMANENT REPAIR ON FRAME LOCATED BS 400 BETWEEN STR 7L TO S-9L ON PASSENGER CABIN, IAW EA N 1-A53-12114 REV 5.SDR SWAA2020113030345Frame · crackedCRACK INDICATION FRAME LOCATED BS 500A BETWEEN STR 8R TO STR 9R AT PASSENGER CABIN. PERFORMED PERMANENT REPAIR ON FRAME LOCATED BS 500A BETWEEN STR 8R TO STR 9R AT PASSENGER CABIN, IAW EA N1-A53-12114 REV 5.SDR SWAA2020113030344Frame · crackedCRACK INDICATION FRAME LOCATED BS 480 BETWEEN SRT 8R TO SRT 9R AT PASSENGER CABIN. PERFORMED PERMANENT REPAIR ON FRAME LOCATED BS 480 BETWEEN STR 8R TO STR 9R ON PASSENGER CABIN, IAW EA N1-A53-12114 REV 5.SDR SWAA2020113030343Frame · crackedCRACK INDICATION FRAME LOCATE BS 400 BETWEEN STR 8R TO STR 9R AT PASSENGER CABIN. PERFORMED PERMANENT REPAIR ON FRAME LOCATED BS 400 BETWEEN STR 7R TO STR 9R ON PASSENGER CABIN, IAW EA N1-A53-12114 REV 5.SDR SWAA2020113030349Frame · crackedCRACK INDICATION FRAME LOCATED BS 867 BETWEEN STR 8L TO STR 9L AT PASSENGER CABIN. PERFORMED PERMANENT REPAIR ON FRAME LOCATED BS 867 BETWEEN STR 7L TO STR 9L AT PASSENGER CABIN, IAW EA N1-A53-12114 REV 5.SDR AALA202011209020Frame · crackedAIRCRAFT IN BASE MAINTENANCE. FOUND CRACKED WEB ON FR68L AT STR 22L DOOR STOP AT NR 1 LOCATION WITH L=0.750 INCH. CUT OUT DAMAGED WEB AND INSTALLED NESTED REPAIR FITTING, REF EA 309580.SDR HNAA2020111200322Frame · crackedFR 25 IS CRACKED BETWEEN STR 16R-15R. PERFORMED SPLICE REPAIR OF FR 25 LOWER FRAME SECTION AND U-SHAPED DOUBLER, IAW EMB 145 SRM 53-00-04 ITEM 4 FIG 201 AND EO1-53-20-0397.SDR HNAA2020111200321Frame · gougedFR 68 RT SIDE HAS MULTIPLE GOUGES ON FWD SIDE AT NUTPLATES. REPAIRED FR 68 RT SIDE HAS MULTIPLE GOUGES ON FWD SIDE AT NUTPLATES, IAW PIEDMONT EO-1-05-20-0410 AND EO1-53-20-0390. SEE TASK AND WIP ENTRIES FOR DETAILS.SDR IPXA2020111062232Frame · crackedINSPECTION TYPE: A300 DURING ACCOMPLISHMENT OF STEP (2) OF TC523208-01-1-812, THE AFT LOWER HOLE OF FR 63 WAS FOUND TO HAVE A CRACK INDICATION AT THE 6 O'CLOCK POSITION AND APPROXIMATELY 1" IN LENGTH. REMOVED DAMAGE & REPAIRED, IAW EA30-5230-27-2511, UPS EO ASDR SWIA202054638Frame · corrodedCORROSION ON FRAME FS 379.00 BETWEEN STGR 22R-24R. C-CHECK RO 12/14/2020. REMOVED AND INSTALLED NEW FRAME SECTOR AT FS 379.00 BETWEEN STGR 20R & 25R, REF DWG CRJ 700 SRM. COMPLIED WITH TASK CARD. PRESSURE CHECK GOOD.SDR SWIA202054637Frame · corrodedFRAME, FS 364.00, CORRODED AROUND FASTENER STGR 26, MARKED. C-CHECK RO 12/14/2020. REPAIRED FRAME AT FS 364.00, STGR 26, REF CRJ 700 SRM REPAIR POCEDURE. COMPLIED WITH TASK CARD. PRESSURE CHECK GOOD.SDR SWIA202054636Frame · corrodedFRAME FS 295.00 HAS CORROSION ON THE LOWER FLANGE AND FORWARD WEB, STGR 25L-STGR 23R, MARKED. C-CHECK RO 12/14/2020. REPAIRED FRAME FS 295.00 LOWER FLANGE FORWARD AND AFT WEB, STGR 25L-STGR 23R, REF CRJ 700 SRM REPAIR PROCEDURE. COMPLIED WITH TASK CARD. PRESDR SWIA202054635Frame · corrodedFRAME FS 310.00 HAS CORROSION ON THE LOWER FLANGE FORWARD AND AFT WEB, STGR 25L-STGR 27, MARKED. C-CHECK RO 12/14/2020. REPAIRED FRAME FS 310.00 LOWER FLANGE FORWARD AND AFT WEB, STGR 25L-STGR 27, REF CRJ 700 SRM REPAIR PROCEDURE. COMPLIED WITH TASK CARD. SDR SWIA202054634Frame · corrodedFRAME FS 319.00 HAS CORROSION ON THE LOWER FRAME, STGR 25L-STGR 26R, MARKED. C-CHECK RO 12/14/2020. REMOVED AND INSTALLED NEW FRAME SECTOR AND REPAIR SPLICE AT FS 319.00 BETWEEN STGR 23R & 25R, REF CRJ 700 SRM. TASK CARD COMPLIED WITH, CHECK GOOD.SDR SWAA2020121429493Frame · corrodedRT FWD WET AREA FLOOR AT STA 328 RBL 48-RBL 56 FRAME UPPER AND LOWER SURFACES HAS CORROSION (18-047). ACCOMPLISHED THIS N/R ON EA NR 1-A53-8530 REV.SDR SCNA20201117326Frame · damagedFRAME HOLE AT BS 992.8 LBL 55 WL 208 IS OUT OF ROUND. REPAIRED FRAME HOLE AT STA 992.8, LBL 55, WL 208, IAW ATS ER 20-03503 REV IR DATED 06-NOV-2020 AND SCA EA 53-0061.SDR SCNA20201117325Frame · damagedFRAME HOLE AT BS 951.07 LBL 55 WL 208 IS OUT OF ROUND. REPAIRED FRAME HOLE AT STA 951.07, LBL 55, WL 208, IAW ATS ER 20-03506 REV IR DATED 06-NOV-2020 AND SCA EA 53-0062.SDR YENA2020111300532Frame · crackedDURING HEAVY MAINTENANCE, CRACK INDICATION ON FRAME 43 LT SIDE IN AFT FASTENER HOLE SIDE BOX BEAM AREA IN PASSANGER CABIN (1 EA), REF AEROMAN NR 2020-308011 WO 2020 330/1. PERFORMED PERMENANT REPAIR ON FRAME 43 LT SIDE ON SIDE BOX BEAM IN PASSANGER CABIN, IAWSDR YENA2020111300531Frame · crackedDURING HEAVY MAINTENANCE, CRACK INDICATION ON FRAME 43 RT SIDE IN AFT FASTENER HOLE SIDEBOX BEAM AREA IN PASSANGER CABIN (1 EA), REF AEROMAN NR 2020-308008 WO 2020 330/1. PERFORMED PERMANANT REPAIR ON FRAME 43 RT SIDE ON SIDE BOX BEAM IN PASSENGER CABIN, IAW SDR SWIA202054626Frame · corrodedFRAME AT FS 333 CORRODED BETWEEN STGRS 24L AND 25L, AS MARKED. C-CHECK RO 12/14/2020. REMOVED AND INSTALLED NEW FRAME AT FS 333 BETWEEN STGRS 24L AND 25L, REF CRJ 700 SRM AND DWG. COMPLIED WITH TASK CARD. PRESURE CHECK GOOD.SDR SWIA202054625Frame · corrodedFRAME CORRODED ON THE AFT WEB & LOWER FLANGE AND FORWARD WEB FS 349.00 STGR 26L-STGR 25R, MARKED. C-CHECK RO 12/14/2020. REMOVED AND INSTALLED NEW LOWER FRAME SECTOR AT FS 349.00 BETWEEN STGR 24R AND STGR 23L, REF DWG CRJ 700 SRM. COMPLIED WITH TASK CARD. SDR FDEA202011072791Frame · crackedTHE RT 1640 FRAME BY STR 14R LOWER INBOARD OPEN HOLE HAS AN INDICATION OF DEFECT NOTED. INDICATION IS AT THE 9 O`CLOCK POSITION LOOKING AFT (GOING OUTBOARD). REPAIR AS REQUIRED, LAYERS NEED TO BE SEPARATED TO DETERMINE WHAT LAYER HAS DEFECT ALL WORK ACCOMPLISDR FDEA202011072790Frame · crackedTHE LT 1640 FRAME BY STR 14L LOWER INBOARD OPEN HOLE HAS AN INDICATION OF DEFECT NOTED. INDICATION IS AT THE 9 O`CLOCK POSITION LOOKING AFT (GOING INBOARD). REPAIR AS REQUIRED, LAYERS NEED TO BE SEPARATED TO DETERMINE WHAT LAYER HAS DEFECT. ALL WORK ACCOMPLSDR DALA2020110903637Frame · crackedWHILE PERFORMING AN INSPECTION FOUND A CRACK ON INBOARD FASTERNER HOLE OF FRAME 1681 LOWER SECTION JUST BELOW WL 208, RIGHT SIDE. THE FRAME STA 1681 LOWER SECTION WAS REPAIRED, PER ER/A 588552-14AD.SDR DALA2021070203675Frame · crackedSHIP 3277 CRACK FRAME 35 LH THAT DOES NOT EXCEED THE AUTHORIZED REPAIR AREA WAS FOUND AT THE PRESSURE PLATE AREA BETWEEN FR35LH AND FR36LH. CORRECTIVE ACTION: REPAIRED PER DELTA WORKCARD AMDS 5311-01171-04A. (1649874)SDR DALA2021070203674Frame · crackedSHIP 3277 CRACK FRAME 35 LH THAT DOES NOT EXCEED THE AUTHORIZED REPAIR AREA WAS FOUND AT THE PRESSURE PLATE AREA BETWEEN FR35LH AND FR36LH. CORRECTIVE ACTION: REPAIRED PER DELTA WORKCARD AMDS 5311-01171-04A. (1649870)SDR DALA2021070203673Frame · crackedSHIP 3277 CRACK FRAME 35 LH THAT DOES NOT EXCEED THE AUTHORIZED REPAIR AREA WAS FOUND AT THE PRESSURE PLATE AREA BETWEEN FR35LH AND FR36LH. CORRECTIVE ACTION: REPAIRED PER DELTA WORKCARD AMDS 5311-01171-04A. (1649855)SDR SWIA202054993Frame · corrodedFRAME SEGMENT CORRODED AT FS 333.00 BETWEEN STGR 25L AND STGR 25R. C-CHECK RO 12/30/2020. REMOVED AND REPLACED FS 333 LOWER FRAME SEGMENT, IAW CRJ 200 SRM. COMPLETED TASK CARD AND ATTACHED COMPLETED FORM 337. NO WEIGHT CHANGE NOTED.SDR SWIA202054967Frame · corrodedFRAME SEGMENT CORRODED AT FS 310.00 BETWEEN STGR 23L AND STGR 25R. C-CHECK RO 12/30/2020. REMOVED AND REPLACED LOWER FRAME SEGMENT AT FS 310, IAW CRJ 200 SRM. COMPLETED TASK CARD AND ATTACHED COMPLETED FORM 337. NO WEIGHT CHANGE NOTED.SDR SWIA202054883Frame · corrodedCORROSION ON FRAME FS 1015.00 BETWEEN STGR 27-25L, FWD SIDE. C-CHECK RO 12/26/2020. REMOVED CORROSION ON FRAME 1015.00 BETWEEN STRG 27-25L FWD SIDE, REF CRJ900 SRM. FOUND TO BE OUT OF LIMITS. RECEIVED AND COMPLIED WITH ALL STEPS OF REO. REWORK WITHIN LIMISDR SWIA202054839Frame · corrodedCORROSION ON FRAME AT FS 1031.00, BETWEEN STGR 27-25L, FWD SIDE. C-CHECK RO 12/26/2020. REMOVED CORROSION ON FRAME 1031.00 BETWEEN STRG 27-25L FWD SIDE, REF CRJ900 SRM. FOUND TO BE OUT OF LIMITS. RECEIVED AND COMPLIED WITH ALL STEPS OF REO. ALL ASSOCIATEDSDR HNAA2020121100345Frame · crackedSSI 53-20-43, FRAME 25 IS CRACKED BETWEEN STRINGERS 15R AND 16R, MARKED. FABRICATED, PREPPED AND INSTALLED SERVICEABLE FR 25 LOWER RT FRAME SECTION INTERNAL SPLICE DOUBLER, IAW EMB 145 SRM 53-00-04, ITEM 4, FIGURE 201 AND EMB 145 SRM 51-20-03 AND 51--40-02 ANSDR SWIA202054477Frame Angle · corrodedCLIP FOR FRAME FS 265 AT STGR 27 HAS CORROSION. C-CHECK RO 12/04/2020. REPLACED CLIP FOR FRAME FS 265 AT STGR 27, REF CRJ700 SRM.SDR SWIA202054476Frame Splice · corrodedEXTERNAL FS 939 PANEL SUPPORT FRAME BUTT SPLICE DIRECTLY BELOW STGR 27 CORRODED, AS MARKED. C-CHECK RO 12/04/2020. REMOVED AND REPLACED SUPPORT FRAME BUTT SPLICE AT FS 939 BELOW STGR 27, PER CRJ700 SRM.SDR DALA2020111103669Frame · crackedCRACK INDICATION ON FRAME 16 RT SIDE AT OPEN FASTENER HOLE 7, CRACK DIRECTION IS 10 O'CLOCK, AT FWD GALLEY AREA . CORRECTIVE ACTION: PERFORMED REPAIR ON FR 16 RT SIDE AT PASSENGER 7, AS PER PRI 588168-14AD REV 0, 1 AND ERA 588168-14 REV ORIGINAL.SDR DALA2020111103668Frame · crackedCRACK INDICATION ON FRAME 16 RT SIDE AT OPEN FASTENER HOLE B, CRACK DIRECTION IS 3 O`CLOCK, AT FWD GALLEY AREA. CORRECTIVE ACTION: PERFORMED REPAIR ON FR 16 RT SIDE AT FASTENER HOLE B, AS PER PRI 588168-14AD REV 0, 1 AND ERA 588168-14 REV ORIGINAL.SDR 2020F00439Frame Angle · corrodedDURING ROUTINE INSPECTION, ON FRAME 6 UNDER THE FLOORBOARDS AT APPROXIMATELY BL 700(LT), THE FRAME ANGLE WAS FOUND CORRODED WITH A SUBSEQUENT CRACK IN THE SUPPORTING ANGLE UNDERNEATH IT.SDR VNAA2020110499920Frame · crackedFRAME AT FS 333.00 IS CRACKED LOCATED BETWEEN STRINGER 1 RT AND STRINGER 2 RT, REPLACED FRAME.SDR VNAA2020110499917Frame · corrodedBOTTOM OF FRAME FS 565.00 IS CORRODED AND FOUND TO BE OUT OF LIMITS.SDR VNAA2020110499916Frame · corrodedBOTTOM OF FRAME FS 549.00 IS CORRODED AND FOUND TO BE OUT OF LIMITS, REPLACED FRAME.SDR VNAA202011049991Frame · corrodedFS 310 HAS CORROSION ON ATTACH FLANGE AND WEB BETWEEN STR 26L & 26R. REPAIRED IAW REO 670-53-21-799 REV A.SDR SWIA202055170Frame · corrodedFS 333.00 CIRCUMFERENTIAL JOINT BETWEEN STRINGERS 20L/21L AND 21L/22L HAS CORROSION. C-CHECK RO 1/5/2021. REMOVED CORROSION AT CIRCUMFERENTIAL JOINT FS 333.00 BETWEEN STRINGER 20L/21L AND STRINGER 21L/22L, REF CRJ 700 SRM 51-21-06-001-001-A01. ORIGINAL MATESDR SWIA202054784Frame · damagedFRAME, FS 379 BETWEEN STGR 24R TO STGR 20R, MARKED. C-CHECK RO 12/26/2020. REMOVED AND REPLACED FRAME AT STA 379 BETWEEN STGR 24R TO 20R, IAW CRJ900 SRM, AND DWG. COMPLETED FORM M-337. SEE CONTINUATION CARD FOR DETAILS. PERFORMED LEAK CHECK, NO LEAKS NOTE
Back to JASC 5311