JASC 5311
Service difficulty reports · 61,540
Reports filed under 5311 · Fuselage Main, Frame, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR VNAA2020080499911Frame · corrodedFWD AVI BAY FS 295 FRAME CORRODED BETWEEN STRG 26L TO 26R. INSTALLED NEW FRAME SEGMENT, 2 SPLICES, AND ATTACHING ANGLES AND PERFORMED FS295.00 FRAME REPAIR IAW CRJ900 SRM 53-00-06-201-006-A01.SDR SWIA2020091652516Frame · corrodedFRAME HAS CORROSION AT APPROX FS 513 AND APPROX STGR 5R. C-CHECK RO 9/12/2020. REMOVED CORROSION FROM FS 513.00 FRAME NEAR STRINGER 5R. REMAINING MATERIAL WITHIN LIMITS, REF REO BOMBARDIER DWG & CRJ200 SRM. COMPLIED WITH TASK CARD.SDR SWIA2020091652511Frame · crackedFUSELAGE FRAME AT APPROX FS 333 BETWEEN STGR 0 AND STGR 3L IS CRACKED AT A TOOLING HOLE, FLAGGED. C-CHECK RO 9/12/2020. REMOVED AND RELPLACED THE FUSELAGE FRAME AT FS 333.00 BETWEEN STGR 0 AND STGR 3L WITH NEW PART AND HARDWARE, REF BOMBARDIER DRAWING CRJ200SDR SWIA2020090452255Frame · corrodedFRAME AF FS.313 BETWEEN DD4-DD5 IS CORRODED. REMOVED AND INSTALLED NEW FRAME AT FS313 BETWEEN DD4 AND DD5. REF DWG AND CRJ 200 SRM. DETAILS.SDR SWIA2020090952324Frame · corrodedCORROSION FOUND ON FRAME FS 379.00 BETWEEN STRG 18L & STRG 19L. C-CHECK RO 9/5/2020. REPAIRED CORROSION OF FRAME FS 379.00 BETWEEN STRG 18L & STRG 19L, REF REO. LEAK CHECK GOOD. COMPLIED WITH TASK CARD.SDR SWIA2020090952384Frame · damagedAFT SIDE OF FS 409 BETWEEN STINGERS 25R AND 26R WAS DAMAGED DURING PART REMOVALS. REQUIRES ENGINEERING. C-CHECK RO 9/5/2020. REPAIRED DAMAGE ON AFT SIDE OF FS 409 BETWEEN STRINGERS 25R AND 26R, IAW MHI RJ REO. TASK CARD COMPLIED WITH, M-337 COMPLETED. WEISDR SWIA202081751815Gusset · corrodedCORROSION IN GUSSET L/H BEAM FR.89. REMOVED AND REPLACED GUSSET FOR LH BEAM FR 89 DUE TO OUT OF LIMITS CRITERIA, REF. EMB SRM.SDR SWIA202081751808Gusset · corrodedCORROSION IN GUSSET R/H BEAM FR.90. REMOVED AND REPLACED GUSSET AT RH BEAM FR 90 DUE TO OUT OF LIMITS MATERIAL LOSS, REF. SRM, RESTORED SURFACE PROTECTION, REF. SRM.SDR SWIA202053899Frame · weakCOMPLY WITH REO 601R-53-41-1116 REPAIR & REINFORCEMENT FOR FS 559.00 LOWER CAP ANGLES BL 9.00 & 18.00 LT & RT. C-CHECK RO 11/11/2020. REPAIR AND REINFORCEMENT OF THE LOWER CAP ANGLE BL 9 AND 18 LT AND RT SIDES WERE ACCOMPLISHED, IAW MHIRJ REO AND BOMBARDIER SDR FDEA202009101705Frame · dentedCABIN, MAIN DECK CARGO COMPARTMENT FRAME DENTED AT STATION 1621, LONGERON 12 RT. CABIN, MAIN DECK CARGO COMPARTMENT AT STATION 1621, LONGERON 12 RT, DENTED FRAME, REPAIRED AS PER SRM 53-00-07 -2R FIGURE 201 REPAIR 2. REPETITIVE INSPECTION REQUIRED-INITIAL ATSDR SWIA2020090152117Frame · cracked*FS333.00 BETWEEN STRINGER 0 AND STRINGER 1L HAS A CRACK AT TOOLING HOLE. (C-CHECK) RO 8/28/2020 REMOVED FRAME AT FS 333.0 STR 1L - 5L REF CRJ 200 SRM 51-42-06. INJSTALLED NEW FRAME SECTION AT FS 333.00 STR 1L - 5L REF CRJ 200 SRM AND BOMBARDIER DWG. COMSDR FDEA2020073091705Frame · dentedCABIN - MAIN DECK CARGO COMPARTMENT FRAME DENTED AT STATION 1621 , LONGERON 12 RIGHTSDR SWIA2020090452243Frame · corrodedFRAME AT FS 559.0+112 IN THE AREA OF RBL 26 TO LBL 26 HAS CORROSION. C-CHECK RO 9/1/2020. EVALUATED AND FOUND FRAME AT FS.559+112 IN AREA OF RBL26 TO LBL26 TO BE OUT OF LIMITS. INSTALLED A NEW FRAME SPLICE ANGLE REF CRJ 200 SRM AND BOMBARDIER DWG. COMPLIEDSDR SWIA2020090452242Frame · corrodedFRAME AT FS 574.0 IN THE AREA OF RBL 26 TO LBL 26 HAS CORROSION. C-CHECK RO 9/1/2020. REMOVED CORROSION AT FRAME FS574.00 IN THE AREA OF STGR 26L TO STGR 26R REF CRJ-200 SRM. BLENDED AREA FOUND TO BE OUT OF LIMITS CRJ200 SRM. REPAIRED FRAME AT FS 574.0 REFSDR SWIA2020090452240Frame · crackedSUSPECT CRACK IN THE FUSELAGE FORMER/FRAME AT APPROX. FS333 AT A TOOLING HOLE AT APPROX. STGR1L (MARKED ON AFT SIDE). C-CHECK RO 9/1/2020. REMOVED AND INSTALLED NEW FUSELAGE FORMER/FRAME PN 601R32004-41 AT APPROX. FS333 AT STGR1L TO STGR4L WITH SEALANT, SOLISDR FDEA202007281690Frame · dentedCABIN - MAIN DECK CARGO COMPARTMENT FRAME EXISTING REPAIR FOUND DENTED AT LEFT STATION 1661 , LONGERON 12 L . REPAIR CARRIED OUT PER MD - 11 SRM 53-00-07 -2R REPAIR 2 FIGURE 201. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.SDR FDEA202007281689Frame · dentedCABIN - MAIN DECK CARGO COMPARTMENT FRAME EXISTING REPAIR FOUND DENTED AT LEFT STATION 1721 , LONGERON 12 L . REPAIR CARRIED OUT PER MD - 11 SRM 53-00-07-2R REPAIR 2 FIGURE 201. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.SDR SWIA2020090452230Frame · corrodedFS333 FRAME HAS CORROSION BETWEEN STGR 25R AND STGR 25L. C-CHECK RO 9/1/2020. REMOVED CORROSION AND FOUND FRAME AT FS.333 TO BE OUT OF LIMITS REF CRJ 200 SRM. INSTALLED A NEW FRAME AT FS.333 REF CRJ 200 SRM AND DRAWING. COMPLIED WITH TASK CARD. SEE CONTSDR SWIA2020090452229Frame · corrodedFS280 CIRCUMFERENTIAL JOINT HAS CORROSION ON MULTIPLE LOCATIONS ON THE STRAP BETWEEN STGR 25R AND STGR 25L (MARKED). C-CHECK RO 9/1/2020. REPAIRED *FS280 CIRCUMFERENTIAL JOINT REF REO. SEE CONTINUATION CARD FOR DETAILS.SDR SWAA2020083104254Frame · crackedCRACK FRAME BS440 BETWEEN STR8L TO STR9L AT FWD GALLEY AREA / REPAIRED FRAME LOC. STR 18L TO STR 9L BS440 AT FWD GALLEY AREA IAW B737-700 SRM 53-00-07-2R-1 REPAIR 1; FIG 201; SHEET 1.SDR SWAA2020083104250Frame · crackedCRACK FRAME BS400 BETWEEN STR8L TO STR9L AT FWD GALLEY AREA / REPAIRED FRAME LOC BS400 BTW STR8L TO STR9L AT FWD GALLEY AREA IAW B737-700 SRM 53-00-07-2R-1 REPAIR 1 FIG 201 SHEET 1SDR SWAA2020083104249Frame · crackedCRACK FRAME BS400 BETWEEN STR8R TO STR9R AT FWD GALLEY AREA / REPAIRED FRAME BS400 BTW STR10R TO STR7R AT FWD GALLEY AREA IAW B737-700 SRM 53-00-07-2R-1 REPAIR 1 FIG 201SDR SWAA2020083104247Frame · crackedCRACK FRAME BS440 BETWEEN STR8R TO STR9R AT FWD GALLEY AREA / REPAIRED FRAME LOC BS440 BTW STR8R TO STR9R AT FWD GALLEY AREA IAW B737-700 SRM 53-00-7-2R-1 REPAIR 1 FIG 201 SHEET 1;2SDR SWAA2020083103917Stub Frame · crackedCRACK FRAME STUB LOCATED AT BSTA 294.5 BTW STR 16R TO STR 17R AT PASSENGER CABIN (1 EA) / REPAIRED FRAME STUB LOCATED BS 294.5 BTW 16R TO STR 17R AT PASSENGER CABIN IAW SRM B737-700 53-10-15-2R-7 REPAIR 7.SDR SWIA2020090952390Frame · corrodedFRAME CORRODED AT FS 605.00 BETWEEN STGR 26R AND STGR 23L. C-CHECK RO 9/5/2020. REMOVED AND REPLACED FS 605.00 BETWEEN STR 26R AND 23L, IAW CRJ 200 SRM AND DRAWING. COMPLIED WITH SKYCARD AND FORM M-337. SEE CONTINUATION CARD FOR DETAILS OF WORK PERFORMED. SDR FDEA202007241638Frame · crackedFRAME 40 TO CENTER WING JOINT AT UPPER SKIN LEVEL TENSION BOLT JUNCTION INSPECTION, RHS UPPER BOLT HOLE WITH CRACK SIGNAL. INSPECTION COMPLIED WITH IAW EA 6-5710-T0355356 P1. MAJOR REPAIR IAW GMM6-2-100.SDR SWAA2020082403613Frame · corrodedCORROSION ON FRAME AT AREA AFT OF ACB BS951.07 RBL45 WL189. MARKED / REMOVED AND REPLACED EXISTING DOUBLER ON FRAME IAW SRM 51-40-02 SRM 51-10-02 PARAGRAPH 9 AND DWG 147A8110 REV:C LOCATED B/S 951.07. BTW STRINGER 20R TO STRINGER 21R.SDR SWIA2020081151727Skin · gougedFUSELAGE SKIN GOUGED AT FS 341 BETWEEN STR 24R AND STR 25R. REPAIRED GOUGE IN FUSELAGE SKIN AT FS 341 BETWEEN STR 24R AND STR 25R IAW MHIRJ REO AND SKYWEST TASK CARD.SDR FDEA2020090421696Frame · gougedGOUGE FRAME 73 RT AT LEVEL STR 21 ON UPPER FUSELAGE REPAIRED FRAME 73 RT AT LEVEL STR 21 ON UPPER FUSELAGE, IAW A300-600 SRM 53-10-13 PAR 5C FIG 202. THIS MUST BE INSPECTED AT DEFINED INTERVALS. THE INSPECTION INSTRUCTION REFERENCE IS 53-10-13-2-002-00 TABLESDR FDEA2020073011696Frame · gougedGOUGE FRAME 73 RH AT LEVEL STR 21R ON UPPER FUSELAGESDR SWAA2020080302164Frame · damagedAFT CARGO BAY BS 727A FRAME HAS DAMAGED FASTENER HOLE ON TOP FLANGE LBL 22 / REPAIRED DAMAGED FASTNER HOLE ON TOP FLANGE OF FRAME AT B.S. 727A LBL 22 IN ACB IAW SRM 53-60-07-2R-2 REPAIR 2SDR FDEA202008281692Frame · gougedGOUGE FRAME 31 AT LEVEL STR-17 LT SIDE ON AFT FACE INBOARD FLANGE IN PASSENGER CABIN. REPAIRED FRAME 31 AT LEVEL STR 17 LT SIDE ON AFT FACE INBOARD FLANGE IN PASSENGER CABIN, IAW SRM A300-600 53-10-13-201 PARA 5.C. THIS REPAIR MUST BE INSPECTED AT DEFINED INSDR FDEA2020082681974Frame · gougedGOUGE FRAME FR-54 BETWEEN STR-12 LT TO 13 LT SIDE ON AFT FACE IN PASSENGER CABIN. PERFORMED PERMANENT REPAIR ON FRAME 54 BETWEEN STR 12 LT TO 13 LT SIDE ON AFT FACE IN PASSENGER CABIN, IAW EA 6-5310-T0355414 A P1 EA TITTLE: FUSELAGE-MAINFRAME-MAIN DECK CARGO SDR FDEA2020081271789Frame · crackedCRACK FRAME 26 BETWEEN STRINGERS 13R TO 14R IN PASSENGER CABIN. REPLACED THE SECTION OF FRAME IAW DRAWING A53777450, SRM 51-40-21, AND SRM 51-72-10.SDR FDEA202008071789Frame · crackedCRACKED FRAME 26, BETWEEN STRINGERS 13R TO 14R. REPLACED THE SECTION OF FRAME IAW DRAWING A53777450, SRM 51-40-21, AND SRM 51-72-10.SDR FDEA2020073081692Frame · gougedGOUGE FRAME 31 AT LEVEL STR-17 LH SIDE ON AFT FACE INBOARD FLANGE IN PASSENGER CABIN REPAIRED FRAME 31 AT LEVEL STR 17 LH SIDE ON AFT FACE INBOARD FLANGE IN PASSENGER CABIN IAW SRM A300-600 53-10-13-201 THIS REPAIR MUST BE INSPECTED AT DEFINED INTERVALSSDR IPXA2020081439019Frame · bentINSPECTION TYPE:3CMAIN CABIN FUSELAGE FRAME AT STA 735 BETWEEN LONGERONS 12R - 13R IS BENT.REPAIRED BENT MAIN CABIN FUSELAGE FRAME AT STA 735 BETWEEN LONGERONS 12R - 13R IAW VT-SAA EA 011-5310-01-A8433 REV. IR AND UPS EO MD11-5310-77478-A. (MAJOR)SDR FDEA2020072771558Frame · corrodedAFT CARGO - DOORWAY AFT JAMB FRAME SURFACE, LEFT HAND STATION 1959 X=32 TO 55 FOUND CORROSION. AFT CARGO DOORWAY AFT JAMB FRAME SURFACE LEFT HAND STATION 1959 X=32 TO 55 CORROSION REMOVED AND FOUND X=34 TO 55 WITHIN LIMIT AS PER SRM 53-00-00-2R FIGURE 20SDR FDEA202007171563Frame · crackedDURING AN NDT OPEN HOLE INSPECTION, TWO CRACK NDICATIONS NOTED IN LOWER INBOARD HOLE AT APPROX. 8 AND 4 O'CLOCK POSTIONS LOOKING AFT. BS 1640 FRAME STRINGER 14L. ALL WORK ACCOMPLISHED IAW EA F-5310-T0355050 P1.SDR SWIA2020082051901Frame · corrodedFS1031 BETWEEN STRINGER 24R TO 26R APPEARS CORRODED. (C-CHECK) RO 8/18/2020 REMOVED CORROSION FROM FRAME AT FS1031 BETWEEN STGR 24R - 26R REF CRJ700 SRM. FOUND TO BE WITH IN LINITS. RESTORED FINISH REF CRJ700 SRM. PRESSURE CHECK GOOD.SDR SWIA202082051873Frame · blockedREMOVE AND REINSTALL FS333.00 FRAME SECTION FROM STR 20R TO STR 25R AND FRAME SPLICE DOUBLER FROM STR 25R TO STR 27 TO FOM STR 21R REPLACEMENT (C-CHECK) RO 8/14/2020 REMOVED AND REINSTALLED THE FS333.00 FRAME SPLICE FROM STR27 TO STR24R AND REPLACED THE FSSDR SWIA2020090952412Frame · corrodedFRAME AT FS 409.00 CORRODED BETWEEN STGR 25L TO 26L. C-CHECK RO 9/5/2020. REMOVED CORROSION AT FRAME AT FS 409.00 BETWEEN STGR 25L TO 26L, IAW CRJ-200 SRM.SDR SWIA2020090952388Frame · corrodedFRAME AT FS 349.00 CORRODED BETWEEN STGR 26L TO 27L. C-CHECK RO 9/5/2020. REMOVED DAMAGED FRAME AT FS 349.00 AND INSTALLED A NEW FRAME, IAW CRJ 200 SRM AND DRAWING NUMBER FOR FASTENER CALL OUT AS DOCUMENTED ON ATTACHED CONTINUATION CARD. PRESSURIZATION AND SDR SWIA2020090952387Frame · corrodedFRAME AT FS 333.00 CORRODED BETWEEN STGR 25L TO 25R. C-CHECK RO 9/5/2020. INSTALLED NEW FRAME AT FS 333 BETWEEN STR 25L TO 25R, IAW CRJ 200 SRM AND DRAWING. COMPLIED WITH SKYWEST AND FORM M-337. PART FOR PART REPLACEMENT. WEIGHT AND BALANCE NOT AFFECTED.SDR SWIA2020090952386Frame Angle · corrodedFWD FRAME ANGLE AT FS 394.00 CORRODED BETWEEN STGR 25L TO 25R. C-CHECK RO 9/5/2020. INSTALLED NEW SERVICEABLE FWD FRAME ANGLE AT FS 394, IAW CRJ-200 SRM.SDR SWIA2020090952383Frame · corrodedFRAME AT FS 364.00 CORRODED BETWEEN STGR 25L TO 25R. C-CHECK RO 9/5/2020. REMOVED COMPONENTS AS REQUIRED FOR ACCESS, REMOVED DAMAGED LOWER FRAME SECTOR. INSTALLED A NEW LOWER FRAME SECTOR AND SAME SERVICEABLE SPLICE PLATES AT FS 364.00, IAW CRJ 200 SRM AND SDR SWIA2020090952382Frame · corrodedFRAME AT FS 319.70 CORRODED BETWEEN STGR 25L TO 25R. C-CHECK RO 9/5/2020. INSTALLED NEW FRAME AT FS 319.70 BETWEEN STR 25L TO 25R, IAW CRJ 200 SRM AND DRAWING. COMPLIED WITH SKYCARD AND FORM M-337. PART FOR PART REPLACEMENT. WEIGHT AND BALANCE NOT AFFECTESDR KCSA202007151116Frame · crackedSTA 800 FRAME RH HAS A CRACK INDICATION IN THE AFT UPPER FASTENER HOLE AT STR 17R. REMOVED FOR SB 747-53A2451.SDR KCSA202007151115Frame · crackedSTA 800 FRAME RT HAS A CRACK INDICATION IN THE FWD LOWER FASTENER HOLE AT STR 17R. REMOVED FOR SB 747-53A2451.SDR KCSA202007151114Frame · crackedSTA 800 STR 23 L UPPER FRAME FASTENER HOLE HAS CRACK INDICATION.
Back to JASC 5311