JASC 5311
Service difficulty reports · 61,549
Reports filed under 5311 · Fuselage Main, Frame, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA202001239005Frame · corrodedFUSELAGE FRAME AT FS310.00 IS CORRODED FROM STR 26LH TO 26RH. AND ON THE AFT VERTICAL SURFACE. -C/A-REPAIRED FUSELAGE FRAME AT FS310.00 IAW SRM 53-00-06.SDR COEA2020032009801Frame · corrodedWO 209330 NR 100076 HEAVY CHECK COE/MAJOR REPAIR: FRAME 12 LOWER R/H SIDE HAS LEVEL 2 CORROSION ON FORWARD SIDE BETWEEN BL 0- STRINGER 21R. CORRECTIVE ACTION: REPAIRED PER SRM 531140-300-803-A01.SDR COEA2020032008801Frame · corrodedWO 209330 NR 100076 HEAVY CHECK COE/MAJOR REPAIR: FRAME 12 LOWER L/H SIDE HAS LEVEL 2 CORROSION ON FORWARD SIDE BETWEEN BL 0-STRINGER 21L. CORRECTIVE ACTION: REPAIRED PER SRM 531140-300-803-A01.SDR COEA2020031305801Splice · corrodedWO 209330 NR 100077 HEAVY CHECK COE/MINOR REPAIR: FRAME 12 LOWER SPLICE HAS LEVEL 2 CORROSION BETWEEN STRINGERS 21L-21R. CORRECTIVE ACTION: REPLACED SPLICE WITH OEM PART.SDR 2020FA0000204Frame · crackedDURING 72-MONTH INSPECTION, CRACKING WAS DISCOVERED AT FRAME STA 1209. THE UPPER FRAME CAP IS CRACKED IN TWO LOCATIONS COMMON TO LONGERON 2L AND 2R. THE FRAME DOUBLER ON THE AFT SIDE WAS ALSO FOUND TO BE CRACKED IN THE UPPER FLANGE THROUGH THE BEND RADIUS. THESDR SWIA2020020648243Frame · corrodedF.S. 333 FRAME HAS CORROSION ON FWD> AND AFT SIDE AS MARKED IN RED IN AVIONICS BELLY AREA (C-CHECK) RO 2/04/2020 REPAIRED F.S. 333 FRAME REF CRJ200 SRM, CRJ200 SRM, AND BOMBARDIER DWG. LEAK CHECK GOODSDR DALA2020010900142Former · corrodedFRAME FORMER Y994 L29-L23 CORRODED. REMOVED FORMER FROM Y994 L20-25, DRILLED, TREATED, AND FITTED FORMER Y994 L20-L25. OK TO INSTALL FORMER. INSTALLED FRAME FORMER ON Y994 FROM L20-L25 PER SRM B717 51-41. RII COMPLETE. (LP #1436253)SDR SWAA2020010710766Rib · damagedL/H HORIZ STAB #4 INSPAR RIB AT STAB STA 120.30 LOWER FLANGE I/B SIDE; 21ST FASTENER HOLE BACK FROM FWD STIFFENER IS OBLONG / R&R'D L/H STAB #4 RIB AT STATION 120.30 PER SRM 51-40-02 & 51-10-02.SDR SWIA2020020648238Frame · corroded* FRAME AT FS 574.0 FWD SIDE HAS CORROSION IN THE AREA OF STR 26L TO 26R (C-CHECK) RO 2/04/2020 REPAIRED FRAME AT FS574 BETWEEN STR26L AND STR26R PER REO.SDR SWIA2020020648237Frame · corroded* FRAME AT FS 589.0 FWD SIDE HAS CORROSION IN THE AREA OF STR 26L TO 26R (C-CHECK) RO 2/04/2020 REPAIRED FRAME AT FS589 BETWEEN STR26L AND STR25R PER REO.SDR SWIA2020020648235Frame · corroded* FRAME AT FS 605.0 FWD SIDE HAS CORROSION IN THE AREA OF STR 26L TO 26R (C-CHECK) RO 2/04/2020 REPAIRED FRAME AT FS605 BETWEEN STR26L AND STR26R PER REO.SDR SWAA2020011340427Frame · crackedFRAME CRACKED AT BS. 440, FASTENER HOLE BELOW STR. 8R. / REPAIRED FRAME IAW EA, SRM, & AMM.SDR 2A6R202001104282Frame · chafedL/H INBOARD SIDE OF AFT LOWER LEG OF THE X-FRAME HAS CHAFFING MEASURING APPROXIMATELY 0.011" DEEP AND 0.3" WIDE BY 2.4".SDR DALA2020010700097Strap · crackedAD/EM-EO TASK - OPEN HOLE HFEC INSPECTION FOUND 02EA CRACKS ON LH FAIL-SAFE STRAP ABOUT 5 O'CLOCK AND 9 O'CLOCK POSITION AT THE LOWER OF THE THREE FASTENER HOLES IN FIGURE 10 AS MARK (LOOKING FROM INBOARD) PER W/C 5312-01170-10A-02 STEP 2. C/A LH STA 955 CRACKSDR DALA2020010700096Strap · crackedAD/EM-EO TASK-OPEN HOLE HFEC INSPECTION FOUND CRACKING IN LH STA955 FAIL SAFE STRAP AS MARK PER W/C 5312-01170-05 STEP 10 AND TO REPAIR THE FAIL SAFE STRAP IN ACCORDANCE WITH EM 5312-01170 SECTION 10A PRIOR TO FURTHER FLIGHT.C/A LH STA955 CRACKED FAIL SAFE STRSDR DALA2020010700095Strap · crackedOPEN HOLE HFEC INSPECTION FOUND 01EA CRACK ON RH STA955 FAIL-SAFE STRAP AT THE LOWER OF THE THREE FASTENER HOLES IN FIGURE 10 AS MARK ABOUT 10 O'CLOCK POSITION (LOOKING FROM INBOARD) PER W/C 5312-01170-10B-02 STEP 2. C/A RH STA955 CRACKED FAIL-SAFE STRAP REPAISDR DALA2020010700094Failsafe · crackedUT INSPECTION FOUND CRACKING IN LH STA 955 FAIL SAFE STRAP AS MARK PER W/C 5312-01170-05 STEP 8 AND TO REPAIR THE FAIL SAFE STRAP IN ACCORDANCE WITH EM 5312-01170 SECTION 10A C/A LH STA 955 CRACKED FAIL SAFE STRAP REPAIRED REFER TO W/C 5312- 01170-10A-02. (143SDR SWAA2021042928700Frame · dentedCREW REPORTS DENT 18 INCHES UP FROM BOTTOM FORWARD CORNER OF FORWORD CARGO DOOR FRAME. DENT MEASURES 3 32 INCH IN DEPTH AND 30 INCHES LONG. WITHIN LIMITS PER SRM 5300011A1 PARAGRAPH 4 A (3) DENTS DETAIL G WY RATIO = 31 REINSPECTION OF THE DENT FOR CORROSION ANSDR K11A2020021240503Frame · crackedUPPER EDGE OF FRAME HAS A CRACK AFT PIT BILGE STA 727B BL 0SDR SWAA2020020544989Frame · crackedFRAME CRACKED AT BS. 380, BETWEEN STR. 8L TO STR. 9L. / REPAIRED FRAME IAW EA.SDR SWAA2020020544988Frame · crackedFRAME CRACKED AT BS. 440, BETWEEN STR. 8L TO STR. 9L. / REPAIRED FRAME IAW EA.SDR SWAA2020020544987Frame · crackedFRAME CRACKED AT BS. 400, BETWEEN STR. 8L TO STR. 9L. / REPAIRED FRAME IAW EA.SDR K11A2020021240502Frame · crackedFRAME CRACKED IN AFT PIT AT EXISTING TOOLING HOLE STA 967 RBL 1SDR QMLA2020012203203Frame · crackedFRAME 5A CRACKED. INSTALLED DOUBLER P/N L533M1022966 PER SB EC135-53-031. AIRCRAFT IS CURRENTLY OUT OF SERVICE.SDR COEA2020033118Frame · corrodedWO 209330 NR 100045 HEAVY CHECK COE/MAJOR REPAIR: FRAME 39 HAS LEVEL 2 CORROSION LOWER SURFACE WHERE IT PASSES THROUGH THE FLOOR WEB. CORRECTIVE ACTION: REPAIRED PER SRAS ES_0115582_01...16012 ISSUE A, DATED 3/18/2020.SDR COEA2020032013801Frame · corrodedWO 209330 NR 300015 HEAVY CHECK COE/MAJOR REPAIR: FRAME 47 AFT SIDE HAS LEVEL 2 CORROSION AT UPPER L/H BONDING POINTS. CORRECTIVE ACTION: REPAIRED PER SRM 538140-300-804-A01.SDR COEA2020030403801Frame · corrodedWO 209330 NR 100031 HEAVY CHECK COE/MINOR REPAIR: FRAME 28A HAS LEVEL 2 CORROSION BETWEEN STRINGERS 20L-21L. CORRECTIVE ACTION: REPLACED WITH OEM PART.SDR SWIA2020020748303Frame · corrodedFRAME AT FS319, AT APROX. STGR21L HAS CORROSION ON THE AFT SIDE. (C-CHECK) RO 2/05/2020 REMOVED DAMAGED AND INSTALLED NEW FRAME AT FS 319 BETWEEN STGR 21L AND 18L REF CRJ 700 SRM AND BOMBARDIER DWG. PRESSURE LEAK CHECK GOOD. COMPLIED WITH THE TASK.SDR SWIA2020020748294Frame Angle · corroded*CLIP ON AFT SIDE OF FRAME, FS319.70, FOR INTERCOSTAL STGR20R IS CORRODED. (C-CHECK) RO 2/05/2020 REMOVED CORRODED CLIP ON AFT SIDE OF FS319.7 STGR 20R AND INSTALLED NEW CLIP,REF CRJ-700 SRM AND BOMBARDIER DWG AND TASK CARD.SDR COEA2020032000000Failsafe · corrodedWO 209330 NR 100010 HEAVY CHECK COE/MAJOR REPAIR: FRAME 14 FAIL SAFE HAS LEVEL 2 CORROSION, STRINGER 16R-18R. CORRECTIVE ACTION: REPAIRED PER SRM 530000-300-817-A01.SDR SWAA2020031342428Strap · not reported(SKYLINE DTIP) FRAME FAILSAFE REPAIR, BS727B, BETWEEN STR20L-22L, STRAP REPAIR NO FURTHER EVALUATION IS NECESSARY PER EA 1-751-1124. (REFERENCE SRL N1010042993) STRAP REPAIR FROM .10 THICK ,7075-T6 CLAD SHEET ON THE AFT SIDE OF THE CHORD AND INSTALLESDR CALA2020010600061Frame · dentedFWD CARGO COMPARTMENT STA500B R/H AT STR23R TO STR24R THE FRAME HAS DENT DAMAGE PER ECRA 5311-02353 INITIATE A DTA DIP TO -ACCOMPLISH INSPECTION REQUIREMENTS ON OR BEFORE THE AIRCRAFT REACHING 75,000 TOTAL FLI GHT CYCLES. PLANNING TO CONTACT ENGINEERING AFTER SDR AALA2020010209007Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FRAME AT BS 1380 BETWEEN S23L TO S26L. REPLACED FRAME PER SRM 51-40-02.SDR SWAA2022040648399Support Bracket · crackedAFT CARGO COMPARTMENT LH BULKHEAD SUPPORT BRACKET CRACKED BS 867 RBL 10 WL 156 / REMOVED CRACKED SUPPORT BRACKET BS 867 RBL 10 WL 156 I.A.W. SRM 51-40-02-0G-0. LOCATED AND DRILLED NEW SUPPORT BRACKET P/O# 774596 I.A.W. SRM 51-40-05-0G-0. INSTALLED NEW BRACKET SDR REXA2020010720017Frame · corroded"INITIAL INSPECTION: (DUE WET INSULATIONS) MAIN AVIONICS COMPARTMENT, CORROSION ON FRAME FS 349 BTW STGR 25L/25R (SM)[E/E].
"SUMMARY OF NRC 00232 CORROSION LEVEL 2:FRAME SECTION AT FS 349 AND BTW STRINGER 23LH TO 23RH WAS REPLACED PER CRJ-90SDR SWAA2020010740172Frame · crackedFORWARD CARGO COMPARTMENT FRAME FASTENER HOLE DAMAGED AND CRACKED AT BS. 500D, WHERE LOWER STEP OF L/H TRANSITION ANGLE ATTACHES TO FRAME. / REPAIRED FRAME PER EA.SDR 2019FA0000422Frame · crackedFRAME BS 500E CRACKED AT STAND-OFF HOLE BELOW STRINGER 21R. REPAIRED IAW EA 43-2019-114.SDR 2019FA0000419Frame · crackedFRAME CRACKED AT FS 500G STR 20L - 21L AT LIGHTNING HOLE FORWARD SIDE REPAIRED IAW SRM 53-00-07 REPAIR 13. CAT B REPAIR.SDR SWIA2020013148025Frame · cracked* STRGR 3L CRACKED AT FRAME 379 MARKED (C-CHECK) RO 1/28/2020 CUT AWAY DAMAGED SECTION OF STRINGER 3L BETWEEN FS 379 AND 394 REF CRJ 200 SRM. INSTALLED STRINGER 3L REPAIR PARTS REF CRJ 200 SRM. WEIGHT OF PART REMOVED IS .12LBS AND WEIGHT OF REPAIR PARTS SDR SWIA2020013148024Frame · cracked* SUSPECTED CRACK AT FS 333 LBL 5 MARKED (C-CHECK) RO 1/28/2020 VERIFIED CRACK, REMOVED CRACKED FRAME SECTOR AT FS 333 LBL 5 REF CRJ 200 SRM. - INSTALLED NEW FRAME SECTOR PN 601R32004-41 AT FS 333 REF DRAWINGS AND CRJ 200 SRM. RESTORED FINISH AND APPLIED SDR SWIA2020013148019Frame · corroded*FS 605 FRAME CORRODED ON FWD SIDE LOWER FLANGE STR 26R-23L (C-CHECK) RO 1/28/2020 BLENDED CORROSION ON FRAME AT FS 605 BETWEEN STGR 26R AND STGR 23L. FOUND TO BE OUT OF LIMITS. REMOVED AND INSTALLED NEW FS 605.00 FRAME LOWER SECTOR AND REINFORCING ANGLESDR SWIA2020013148018Frame · corroded*FS 589 FRAME ON FWD SIDE LOWER FLANGE CORRODED FROM STR 25R-23L (C-CHECK) RO 1/28/2020 REPAIRED FRAME AT FS 589. REF BOMBARDIER REO AND BOMBARDIER DWG. REFERENCE THE CONTINUE CARD FOR DETAILS. PRESSURE LEAK CHECKS GOOD.SDR CALA2020010600048Frame · gougedSUPPORT TASK, FRAME AT STATION 294.5 HAS GOUGE AT STRINGER 3L. REF TO PEMCO NR 2645N977 EVALUATED AREA ORI. MAT .051" MAT LOSS .020", MAT REMAINSING .031". FOUND TO BE OUT OF LIMITS IAW B737-800 SRM 53-00-07 FIG 102. DETAIL C, FABEB ANGLE 063 7075 O SENDED TO SDR VNAA2019122699910Frame · corrodedFS 295 LOWER FRAME SEGMENT IS CORRODED. FOUND CORROSION ON FS 295 TO BE OUT OF LIMITS IAW REO 670-53-21-1308 STEP 1 EXCEEDED THE .70" DIAMENSION, MENTIONED IN MAIN VIEWS. FS 295 LOWER SEGMENT REQUIRES REPAIR IAW REO 670-53-21-799. C/W STEPS 1-3 OF REO 670-5SDR VNAA2019122699908Frame · corrodedBS 349 FRAME SECTOR CORRODED BETWEEN STRINGERS 26R AND 27. REMOVED AND REPLACED THE FRAME SECTOR IAW SRM 51-42-06-001-001-A01 AND 51-42-21. SRM 51-40-11-001-001-A01.SDR DALA2019122657547Frame · crackedBS 1809.5 BULKHEAD OUTER FRAME BETWEEN STRINGERS 13AR TO 20R WAS FOUND CRACKED . THE FRAME WAS REPAIRED IAW PRI 583489-14, REV 0. PRI583489-14 REV 1.PRI583489-14 REV 2.SDR SWAA2022032812372Frame · corrodedAFT CARGO COMP. BS 947 FRAME RBL3 AND 12 WL 157 HAS SURFACE CORROSION. (MARKED) / BS947 FRAME AT RBL3 AND RBL12 W.L157 REPAIRED IAW EA 1-753-36477 REV IR AND ATS ER 20-01042 REV IRSDR NACA2020010800176Frame · crackedBS500F, S20L - S21L, 1.04" WIRING PENETRATION HOLE CRACKED IN FRAME WEB. REPAIR IAW SB 737-53A1279 B737-400, 53-00-07 REPAIR 20SDR NACA2019122400175Frame · crackedBS500B, S21R - S22R TOOLING HOLE CRACKED IN FRAME. CONTACT BOEING ENGINEERING, SDR STILL OPENSDR SWIA2020021448467Frame · corrodedFRAME 333 HAS CORROSION SPOTS ON THE FWD SIDE BETWEEN STGR 23R THRU 22R IN THE FWD E&E BAY (C-CHECK) RO 2/10/2020 REMOVED AND REPLACED FRAME STATION 333 FROM THE SERVICE DOOR THRESHOLD IAW CRJ-200 SRM. 601R32004-795 TAG BB5202