JASC 5311
Service difficulty reports · 61,549
Reports filed under 5311 · Fuselage Main, Frame, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2019022501306Frame · corrodedCORROSION LEVEL: 2 FRAME CORRODED BS 1351, STR 18L-19L. REMOVED CORROSION FOUND OUT OF LIMITS, REPAIRED PER SRM 53-00-07. (LP 0958186)SDR DALA2019020700840Frame · crackedHFEC INSPECTION FOUND 01EA CRACK ON LT BS 903.5 FRAME INNER CHORD TRANSITION RADIUS. REPAIRED.SDR DALA2019022601310Frame · corrodedCORROSION LEVEL: 2 FRAME CORRODED BS 1241, STR 19R-20R. INSTALLED NEW ANGLE. (LP 0959486)SDR DALA2019022601309Frame · corrodedCORROSION LEVEL: 2 FRAME CORRODED BS 1417, STR 18R. INSTALLED NEW ANGLE PER SRM 53-00-07. (LP 0959476)SDR DALA2019022651223Frame · corrodedCORROSION LEVEL: 2 FRAME CORRODED BS 1131,STR 16L-17L. BLENDED AND REMOVED CORROSION. ALODINE AND PRIMED, LOCATED DRILLED AND DEBURRED REPAIR ANGLE, INSTALLED. (LP 0958107)SDR WVER2019020623Frame · corrodedLOWER FRAME SECTOR FS 333.00 CORRODED FROM STR 26R TO STR 24R BEYOND LIMITS.SDR WVER2019020622Frame · corrodedLOWER FRAME SECTOR AT FS 319.00 BETWEEN STR26R AND 26L IS CORRODED BEYOND REPAIRABLE LIMITS.SDR WVER2019020620Frame · corrodedLOWER FRAME SECTOR AT FS 349.00 BETWEEN STR27 AND STR 25R CORRODED BEYOND REPAIRABLE LIMITS.SDR REXA2019061850907Frame · crackedFRAME 605 IS CRACKED ON THE FWD SIDE JUST ABOVE AND BELOW STGR 9L, IN THE CARGO BAY. REPAIRED CRACKS ON FRAME 605 ABOVE AND BELOW STGR96 IAW BOMBARDIER REO #601R-53-61-5214.SDR DALA2019020600809Frame · crackedCANTED FRAME CRACKED AT TAILCONE ALIGNMENT PIN L/H SIDE JUST ABOVE TAILCONE TORQUE CAM. REMOVED UPPER PORTION OF CANTED FRAME DRILLED NEW UPPER CANTED FRAME BEGAN INSTALL REPLACED UPPER CANTED FRAME F.S. 1510 PER DRWG 5966768 RTEPLACED TAILCONE CAM ASSY PER MDSDR ABXR2019020500258Strap · corrodedFAIL SAFE STRAP CORRODED.SDR A6WA2019021146384Frame · crackedFS 605 FRAME AT STR 9L CRACKED. REPAIRED.SDR ABXR2019020400239Strap · corrodedFAIL SAFE STRAP CORRODED.SDR ABXR2019020400196Frame Splice · corrodedFRAME SPLICE CORRODEDSDR ABXR2019020400195Frame Splice · corrodedFRAME SPLICE BRACKET CORRODEDSDR ABXR2019020400171Frame · corrodedSTRINGER FRAME CORRODED.SDR UIEA2019020503114Frame · corrodedCORROSION-FOUND 30EA CORROSION DAMAGES WHEN PERFORM SB 747-53A2878.(<P>1.REPAIR DAMAGED AREA I.A.W. EI NO. T2019A53M319 REV.2 2.JOB COMPLETED AND COND CHK NML. 3. JACKING EI. NO.T2019A07M-315 REV.0 THAN ATTACHECHED TO NRC WO.3058015(579).</P>)SDR SWAA2019021829756Frame Splice · corrodedFORWARD CABIN FRAME FACTORY SPLICE CORRODED AT BS 294.5, STR 1. R&R SPLICE IAW SRM & DWG.SDR DALA2019020200785Frame · crackedHFEC INSPECTION FOUND 01EA CRACK APPROX 0.150" IN LENGTH IN THE RADIUS OF STA 1809 BULKHEAD LEFT FORWARD OUTER CHORD AT STRINGER 5L. CRACK REPAIRED.SDR DALA2019020530762Frame · corroded(AIRCRAFT 681, L/P 0929436) CABIN B.S. 1160 STRGR 17 LT. MAIN FRAME WEB HAS EXFOLIATED CORROSION - MARKED - DOT 064 - CP53-241-02I. CUT OUT DAMAGED SECTION OF FRAME, DIM 1.9" X .650" AND REPAIRED FRAME SECTION ALL IAW DELTA ER/A 574804-14 REV ORIGINAL.SDR ASOA201902027024Frame · dentedTYS A/C IS IN C-CHECK WHEN INSPECTION FOUND THE AFT FRAME 79 LEFT SIDE EXTERNAL FUSELAGE DENTED. MAINTENANCE REPAIRED THE DENT IAW SRM 53-32-01 TYPE A AND FIG SHEET 1. ALL WORK ACCOMPLISHED AND WILL BE RELEASED AT THE END OF THE CHECK.SDR ABXR2019020200084Frame · corrodedFRAME STATION 1175 HAS CORROSON ON WEB.SDR ABXR2019020200082Frame · corrodedSTRINGER AND FRAME CORRODED.SDR ABXR2019020200070Frame · corrodedFRAME SEGMENT CORRODEDSDR REXA2019020100128Frame · corrodedCORROSION ON FRAME IN STA FS= 349 BTW STR 26R TO 27 AT MAIN AVIONIC S COMPARTMENT. LEVEL CORROSION 2. FRAME IN STA FS= 349 BTW STR 26R TO 27 AT MAIN AVIONICS COMPARTMENT WAS REPAIRED PER REO 670-53-21-1
281.SDR A6WA2019020246354Frame · corrodedLOWER FLANGE ANGLE AT FS 333 IS CORRODED. REPLACED.SDR ABXR2019020100040Frame · corrodedRH MAIN FRAME PICKLE FORK CORRODEDSDR DALA2019020100660Frame · damagedTRANSFERRED FROM NR 10, LEFT SIDE FUSELAGE FRAME 1079, DAMAGED AT LONGERON L-21L. REPAIRED PER ERA 574949-14 REV A.SDR VNAA2019020199907Frame · crackedFS 333.0 FRAME IS CRACKED BETWEEN STRINGER 0 AND STRINGER 1L. C/A: REMOVED AND REPLACED FRAME IAW CRJ 200SRM 51-40-11,51-42-21 AND 51-42-06.SDR SWIA2019030545602Frame · corrodedCORROSION ON FLANGE OF FRAME, FS605.00, STGR21L €“ STGR23L. (C-CHECK) RO: 03/02/2019 BLENDED/REMOVED CORROSION FROM FS605 FRAME LOWER FLANGES LOCATED BETWEEN STGR-21L & STGR-23L IAW REO. PRESSURE CHECK GOOD.SDR DALA2019013100775Frame · crackedHFEC INSPECTION FOUND 01EA CRACK ON RT BS 903.5 FRAME INNER CHORD TRANSITION RADIUS AND REPAIRED.SDR DALA2019013100774Frame · crackedFOUND 01EA CRACK ON LT BS 883.5 FRAME INNER CHORD TRANSITION RADIUS. REPAIRED.SDR SWAA2019022029853Frame · corrodedE&E COMPARTMENT STUB FRAME LOWER CHORD ON VERTICAL AND SKIN FLANGE CORRODED AT BS 336, STR 23L. REPAIRED CHORD IAW SRM, DWG, AND EA.SDR CALA2019020100191Frame · corrodedREF L/P 9645024 FOUND CROSSION ON FRAME AT STATION 1560 S-27R AND S-28R REF FLEETCYCLE L/P 9645024 FOR ALL WORKED PERFORMED PLACED ON DI P IAW ECRA5360-01501 PAGE 6 OF 12 STEP 7 TO ACCOMPLISH A PERMANE NT REPAIR ON OR BEFORE 24 MONTHS PLANNING TO CONTACT ENGINSDR SWAA2019022129881Frame · crackedABOVE L1 DOOR CUTOUT FRAME RADIUS CRACKED AT BS 312. REPAIRED FRAME PER EA AND ER.SDR AALA201902079017Frame · corrodedAIRCRAFT WAS GROUNDED: CORROSION ON FRAME FLANGE AT BS 907 BETWEEN S23L AND S24L. REPAIRED FRAME PER EA 289535.SDR DALA2019020180675Frame · damagedSHIP 681 AFT CARGO FRAME DAMAGED S26R-S27R STA 1320. CORRECTIVE ACTION: REPAIRED AFT CARGO FRAME AT STA.1320 S26R-S27R IAW B757 SRM. (0921542)SDR A6WA2019012946342Frame · corrodedFS 319 IS CORRODED AT STR 26R.SDR CALA2019012800187Frame · dentedDENT ON AFT CARGO FRAME UPPER FLANGE AT STA 1400 ABOVE STR 25L. AFT CARGO FRAME UPPER FLANGE DENT AT STA 1400 S-25L FOUND OUT OF LIMITS L=3.0, W=.85, D=.052 IAW SRM 53-00-07 FIG 101. CUT OUT DAMAGE AND ACCOMPLISHED PERMANENT REPAIR IAW SRM 53-00-07-R5.SDR K11A2019032629005Frame · crackedMAIN DECK R/H FASTENER HOLE JUST BELOW FLOOR HAS A CRACK.SDR DALA2019012800567Former · crackedCRACKED FORMER ON RT MLG FWD DOOR JAMB OUTBOARD SECTION (FYT). NRC 00184: FORMER WAS REPLACED PER SRM 51-41-05-0G AND SRM 51-41-02-0G. (LP #0920939)SDR A6WA2019012846340Frame · corrodedFS 310.00 LOWER FRAME SEGMENT IS CORRODED AT STRINGER 26R.SDR CALA2019012800170Frame · crackedRT FR 20 DOUBLE JOGGLE UPPER CORNER I/B ROW, 3RD INSP HOLE FROM TOP NR 6 HOLE, HAS CRACK INDICATION. NTM 53-11-55, FIG 53-11-55-991-001-A. REPAIRED HOLE NR 6 AT RT FR 20 DOUBLE JOGGLE AREA IAW ECRA 5311-02072.SDR DALA2019012600587Frame · crackedDURING INSPECTION FOUND CRACK ON FRAME FROM STATION 727B BTW S8L TO S9L. FRAME FROM STATION 727B BTW S8L TO S9L WAS REPAIRED PER ER/A 574641-14AD REV ORIGINAL.SDR DALA2019012600586Frame · crackedDURING INSPECTION FOUND CRACK ON FRAME FROM STATION 400 BTW S8R TO S9R. MAINTENANCE REPAIRED CRACK PER ERA 574641-14AD REV ORIGINAL.SDR CALA2019012800165Frame · crackedREF N/R 9615401, RT FR 20 DOUBLE JOGGLE UPPER CORNER I/B ROW, 3RD INSP HOLE FROM TOP #6 HOLE, HAS CRACK INDICATION. NTM 53-11-55, FIG 53-11-55-991-001-A. REPAIRED HOLE #6 AT RT FR 20 DOUBLE JOGGLE AREA IAW ECRA 5311-02072. ACCOMPLISH THE INITIAL INSP PER PART SDR VNAA2019012599902Frame · crackedFS605 FRAME IS CORRODED BETWEEN STR 26L & 26R. FRAME WAS REPLACED.SDR SWAA2022030234333Frame · corroded***CORROSION*** ON FRAME AT FWD PASSENGER COMPARTMENT BS294.5 S-3L WL288.1. (MARKED) / AFTER DAMAGE REMOVAL; THE BLEND MEASURES 1.6' X 1.0'; MINIMUM REMAINING THICKNESS OF 0.043'. ORIGINAL THICKNESS 0.051' THE AREA WAS REWORKED AS PER EA 1-753-34250 REV IR ANDSDR SWAA2022030264077Splice · corrodedCORROSION ON FRAME SPLICE IN AFT CARGO BAY BS 787 BETWEEN S-24R AND S-25R / REMOVED AND REPLACED FRAME CAP SPLICE AT BS 787 STR 24R-25R IAW SRM 51-40-02-0G-0 AND DWG 146A1262 81489U 25JAN19SDR DALA2019012500516Doubler · crackedINITIAL INSPECTION: CRACK ON PREVIOUS REPAIR DOUBLER OF WEB Y = 1485 CANT, 11 HRS AT AFT ACCESSORY COMPARTMENT. REPAIR DOUBLER OF WEB Y =1485 CANT, 11 HRS AT AFT ACCESSORY COMPARTMENT WAS REPLACED PER ERA 537343-14MA REV.B SECTION III. (LP0917292)
Back to JASC 5311