SDR DALA2017031702152Frame · corrodedCORROSION ON FRAME BS 1326 BETWEEN LONGERONS 29L TO 29R. REPAIRED IAW SRM 53-10-02.SDR DALA2017031702151Frame · corrodedCORROSION ON FRAME BS 1344 BETWEEN LONGERONS 29R AND 29L. FABRICATED AND INSTALLED REPAIR PARTS IAW SRM 53-0-02 AND 51-10-03.SDR QXEA2017041000226Frame · corrodedCORROSION ON FRAME FLANGE AND WEB FORWARD AND AFT FACE FS 216 BETWEEN STR 25-26L. DERIVETED FRAME FLANGE COMMON TO SKIN AT FS X216, BETWEEN STR 25P TO 26P IAW SRM 51-42-05. CUT FRAME FLANGE AND WEB IAW RD 84-53-8048. NDT CARRIED OUT IAW NDTM 6, 51-00-08-250-80SDR ASOA201703151403Frame · corrodedFS 295 FRAME AFT SIDE BETWEEN STR 26L TO 26R HAS CORROSION. REMOVED CORROSION FROM FS 295 FRAME AFT SIDE AND BETWEEN STR 26L TO STR 26R IAW SRM 51-21-06-001-001-A01. PERFORMED UT THICKNESS CHECK; MATERIAL REMOVED .003", ORIGINAL .050", REMAINING .047" PER NDSDR FDEA201703150895Frame · dentedCABIN, MDCC FRAME REPAIR FOUND DENTED AT BS 1681, LONGERON 12R. REPAIRED IAW SRM 51-33-01-0G AND SRM 53-00-07-2R, FIG 201, REPAIR 2. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100.SDR FDEA201703150894Frame · dentedMDCC FRAME REPAIR FOUND DENTED AT BS 1701, LONGERON 12L. REPAIRED IAW SRM 51-33-01-0G, AND SRM 53-00-07-2R, FIG 201, REPAIR 2. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100.SDR DALA2017031602240Frame · dentedAFT CARGO, BS 1560, FRAME, AT STRINGER 27L, DENTED. REMOVED DAMAGE AND REPAIRED IAW SRM 53-00-07, REPAIR 5.SDR DALA2017031602239Frame · dentedAFT CARGO, BS 1340, FRAME ABOVE STRINGER 27R, DENTED. REMOVED DAMAGE & REPAIRED IAW SRM 53-00-07, REPAIR 5.SDR DALA2017031502185Frame · crackedHFEC SURFACE INSPECTION FOUND CRACK APPROXIMATELY 0.15 AS MARKED ON RT BS 859.5 RBL 89 BELOW WL 200 AT THE FRAME INNER CHORD TRANSITION RADIUS. REPAIRED AND ACCOMPLISHED AS PER W/C:5311-01195 09B.SDR DALA2017031602110Frame · crackedFOUND A CRACK ON THE FRAME WEB, FWD SIDE. LOCATED 4 FASTENERS BELOW LONGERON 7L, BS 942.225. REPAIRED IAW SRM 53-03D FIG. 38D.SDR 7C7A2017031500296Frame · chafedCHAFE DAMAGE TO LT MACHINED FRAME (P/N 85320575) AT X253.4 AND BETWEEN STR 23P & 24P. REPAIRED IAW RD 8-53-15102 AND ECO008.53-17.12.SDR ASOA201703141402Frame · corrodedFS 295 FRAME AFT SIDE BETWEEN STR 26L TO 26R HAS CORROSION. REMOVED CORROSION FROM FS 295 FRAME AFT SIDE AND BETWEEN STR 26L TO STR 26R IAW SRM 51-21-06-001-001-A01. PERFORMED UT THICKNESS CHECK; MATERIAL REMOVED .003", ORIGINAL .050", REMAINING .047" PER NDTSDR SIMA20170314002Frame · corrodedFRAME 65 IS CORRODED AT LOWER GUIDE PLATE. FABRICATED AND INSTALLED REPAIR DOUBLER ON FRAME 65 AT LWR GUIDE PLATE IAW ERS-EM-53MR-2619.SDR DALA2017031502234Frame · dentedAFT CARGO, BS 1580, FRAME, BELOW STRINGER 26R, DENTED. REMOVED DAMAGE, FABRIACTED A REPAIR AND INSTALLED IAW SRM 53-00-07, REPAIR 7.SDR DALA2017031502233Frame · dentedAFT CARGO, BS 1580, FRAME, BELOW STRINGER 26R, DENTED. REMOVED DAMAGED, FABRICATED A REPAIR AND INSTALLED IAW SRM 53-00-07, REPAIR 7.SDR DALA2017031502232Frame · dentedAFT CARGO, BS 1480, FRAME, ABOVE AND BELOW STRINGER 27L, DENTED. REMOVED DAMAGE . FABRICATED AND INSTALLED A REPAIR IAW SRM 53-00-07, REPAIR 5.SDR DALA2017031502231Frame · dentedAFT CARGO, BS 1480, FRAME, ABOVE AND BELOW STRINGER 27L, FOUND DENTED. REMOVED DAMAGE. FABRICATED AND INSTALLED A REPAIR IAW SRM 53-00-07, REPAIR 5.SDR CALA2017031700603Frame · gougedSCREW GOUGING J SECTION OF FRAME AT BS 1520 AND STRINGER 26R. FOUND TO BE OUT OF LIMITS IAW SRM 53 -00-07, FIG 101, SHT 1-4. PERFORMED REPAIR ON FRAME IAW SRM 53-00-07, REPAIR 5, FIG 201, DETAIL 1.SDR DALA2017031502091Frame · dentedFWD CARGO BAY, BS 660, FRAME, BETWEEN STR 23-24L DENTED. CUT OUT DAMAGE, FABRICATED REPAIR ANGLES AND INSTALLED IAW PRI 553121-14, REV O, REV 1 & ER.A 553121-14, REV ORIGINAL.SDR DALA2017031502090Frame · dentedFWD CARGO, BS 640, FRAME, BETWEEN STRINGERS 23-24L DENTED. REMOVED DAMAGE & REPAIRED THE FRAME IAW PRI 553122-14 REV 0, REV 1, & ER/A 553122-14, REV ORIGINAL.SDR DALA2017031502088Frame · dentedAFT CARGO BAY FRAME AT BS 340 STRINGER 26R HAS A DENT ON UPPER FLANGE. REMOVED DAMAGE IAW SRM. A REPAIR INSTALLED IAW SRM.SDR SWAA2017032812735Frame · crackedRIGHT LOWER FRAME WEB CRACKED AT BS 727, WL 200. REPAIRED IAW EA.SDR SWAA2017032812734Frame · crackedLEFT LOWER FRAME WEB CRACKED AT BS 727, WL 200. REPAIRED IAW EA.SDR DALA2017031302042Frame · crackedHFEC SURFACE INSPECTION FOUND A CRACK APPROXIMATELY 0.18 OF AN INCH ON BS 883.5 LBL 89 BELOW WL 200 ON THE FRAME INNER TRANSITION RADIUS. REPAIRED IAW 5311-01195-09C.SDR DALA2017031302041Frame · crackedHFEC INSPECTION OF BS 903.5 FRAME INNER TRANSITION RADIUS. A CRACK INDICATION WAS FOUND APPROXIMATELY 3/8 INCH IN LENGTH. REPAIRED IAW 5311-01195-09F.SDR A6WA2017031644857Frame · chafedFRAME DAMAGED BS 718, STRINGERS 16-17L. REPAIRED THE FRAME .SDR A6WA2017031644854Frame · corrodedFRAME BS 513 IS CORROEDED BETWEEN STRINGERS 5 - 6R.SDR A6WA2017031644853Frame · corrodedFRAME BS 513 CORRODED BETWEEN STRINGER 5-6LSDR ASOA201703121327Frame · corrodedFRAME BS 333 CORRODED AFT SIDE BETWEEN STRINGERS 27 - 26L. REPAIRED IAW EC/TC REO 670-53-21-1308, AND REO 670-53-21-1308.SDR ASOA201703121326Frame · corrodedFRAME BS 319.7 CORRODED BETWEEN STRINGERS 26R - 26L. REPAIRED IAW EC/TC REO 670-53-21-1308, AND REO 670-53-21-1308.SDR WVER2017031109Frame · crackedFUSELAGE FS 220 LT FRAME HAS AND INDICATION .25 INCHES LONG THROUGH 3RD FASTENER HOLE DOWN FROM STRINGER 13L. FAILED NDT INSPECTION.SDR WVER2017031008Frame · crackedDURING INCORPORATION OF SB 670BA-53-045, FOUND FS 235.00 UPPER FRAME SECTOR TO BE CRACKED. REPLACED CRACKED FRAME SECTOR IAW STANDARD STRUCTURAL REPAIR MANUAL PRACTICES.SDR WVER2017031007Frame · crackedDURING INCORPORATION OF SB 670BA-53-045, FOUND FS 220.00 UPPER FRAME SECTOR TO BE CRACKED. REPLACED CRACKED FRAME SECTOR IAW STANDARD STRUCTURAL REPAIR MANUAL PRACTICES.SDR VGCA20170309006Frame · corrodedCORROSION FOUND ON THE FRAME AT BS 1142.SDR VGCA2017043009005Frame · crackedCRACK FOUND ON THE FRAME AT BS 480, STRINGERS 16L & 17L.SDR DALA2017031002001Frame · crackedNOSE LANDING GEAR WHEEL WELL CUTOUT FRAME CRACKED BS 45 RIGHT SIDE. REMOVED AND REPLACED THE FRAME IAW SRM 51-30-02, 51-30-05, AND DWG 991008, REV CJ.SDR DALA2017030901929Frame · crackedHFEC SURFACE INSPECTION FOUND CRACKED APPROX.0.20 ON THE FRAME AT BS 883.5, RBL 89 BELOW WL 200. REPAIRED THE FRAME.SDR DALA2017030901928Frame · crackedHFEC SURFACE INSPECTION FOUND A CRACK APPROX. 0.18 AT BS 859.5 LBL 89, BELOW WL 200 AT FRAME INNER CHORD. REPAIRED THE FRAME.SDR DALA2017031001926Frame · crackedAFT ACCESSORY BAY, CRACKED FRAME BS 1451, LONGERON 3L - 3R. REPAIRED IAW ETI-88-17-080, REVISION 4, AND ER/A 555642-14, REV ORIGINAL.SDR DALA2017031001921Frame · crackedFRAME CRACKED RT SIDE BS 1076 AFT FLANGE IN RADIUS. REPAIRED IAW PRI 556132-14, REVISION O, AND COMPLIED WITH ER/A 556132-14 REVISION ORIGINAL.SDR DALA2017030901925Frame · damagedBS 237 FRAME BETWEEN LONGERONS 17 AND 18L IS CRACKED AND BENT. REMOVED AND REPLACED THE FRAME IAW SRM 51-41.SDR DALA2017030901918Frame · dentedAFT CARGO, STA 1600, LT FRAME, BELOW S-27, DENTED. REMOVED DAMAGE ON STA 1600 ABOVE STR 27 L/H (1.3" X .080" TRIMOUT) AND REPAIRED IAW SRM 53-00-07 REPAIR 5 ID REPAIR IAW PS 900-5-1 NR 4.SDR DALA2017030901915Frame · dentedAFT CARGO, STA 1600, LT FRAME, BELOW S-27, DENTED. REMOVED DAMAGE ON STA 1600 ABOVE STR 27L (1.3" X .080" TRIM OUT) AND REPAIRED IAW SRM 53-00-07 REPAIR 5 ID REPAIR IAW PS 900-5-1 NR 4 HFEC INSPECTION ACCOMPLISHED ON LOG PAGE2922262 DETAILED VISUAL INSPECTION SDR DALA2017030901914Frame · dentedAFT CARGO, STA 1600, LT FRAME, BELOW S-27, DENTED. REMOVED DAMAGE ON STA 1600 ABOVE STR 27L (1.3" X .080" TRIM OUT) AND REPAIRED IAW SRM 53-00-07 REPAIR 5 ID REPAIR IAW PS 900-5-1 NR 4.SDR DALA2017030801992Frame · crackedOVERWING FRAME CRACKED, BS 962 RIGHT SIDE. REMOVED AND REPLACED THE FRAME.SDR DALA2017032102267Frame · dentedAFT CARGO, STA 1400, LT FRAME, BELOW S-26, DENTED. REMOVED DENTED AREA FROM FREE FLANGE OF FRAME, FABRICATED AND INSTALLED REPAIR IAW SRM. REF NRC 5189806 AND LOG PAGES 2936571 AND 2936589.SDR DALA2017031502094Frame · dentedAFT CARGO, BS 1480, FRAME, ABOVE AND BELOW STRINGER 27L DENTED. REMOVED THE DAMAGE. FABRICATED AND INSTALLED A REPAIR IAW SRM.SDR YADA20170308002Frame · crackedWHILE AIRCRAFT WAS IN SCHEDULED HEAVY MAINTENANCE, MECHANIC WAS PERFORMING VISUAL C-CHECK AND FOUND A CRACK IN FRAME AT FS 509.50, WL 96 APPROXIMATELY (JUST AFT OF CARGO DOOR). P/N:114-430125-5SDR YADA20170308001Frame · crackedWHILE AIRCRAFT WAS IN SCHEDULED HEAVY MAINTENANCE, MECHANIC WAS PERFORMING VISUAL C-CHECK AND FOUND A CRACK IN FRAME P/N:114-430121-33 AT FS 456.00 APPROXIMATELY WL 96(JUST FORWARD OF CARGO DOOR).SDR FDEA201703060786Frame · chafedMAIN CABIN FRAME 20 CHAFED BETWEEN STRINGERS 13 AND 14R. REPAIRED THE FRAME IAW EA 6-5310-T0331410, PART 1, STEPS 1 - 5.
Back to JASC 5311