JASC 5311
Service difficulty reports · 61,549
Reports filed under 5311 · Fuselage Main, Frame, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2015061840906Frame · crackedFRAME OTBD CHORD CRACKED AT BS 727, STRINGER 18A, LT SIDE. REPAIRED CHORD IAW EA.SDR SWAA2015070141283Former · corrodedKEEL BEAM FORMER CORRODED AT BS 696, BETWEEN LONGERON 30R TO 26R. R & R FORMER IAW DWG.SDR SWAA2015061140599Frame · crackedFOUND A FUSELAGE FRAME CRACKED AT BS 400, STRINGER 8R. REPAIRED THE FRAME IAW EA.SDR SWAA2015061140598Frame · crackedA FUSELAGE FRAME WAS FOUND CRACKED AT BS 360, STRINGER 8R. REPAIRED THE FRAME IAW EA.SDR SWAA2015060540421Frame · crackedFUSELAGE FRAME CRACKED AT STATION 360, STRINGER 8L. REPAIRED FRAME IAW SRM.SDR ASOA2015060413022Frame · corrodedBS 310 FRAME HAS CORROSION AT SPLICE LOCATION BETWEEN STR 22 & 23R. REMOVED FS 310 FROM STR 16R TO 23R IAW SRM 51-42-06, PT 601R32002-65. LOCATED AND DRILLED NEW FS 310 FRAME SECTOR, PN 601R32002-65 IAW SRM 51-40-11. INSTALLED FRAME SECTOR AT FS 310 FROM STSDR SWAA2015052840127Frame · crackedFRAME CRACKED AT BS 867, STRINGER 8R. REPAIRED FRAME IAW EA.SDR SWAA2015052840126Frame · crackedFRAME CRACKED AT BS 827, STRINGER 8R. REPAIRED FRAME IAW EA.SDR SWAA2015052840125Frame · crackedFRAME CRACKED AT BS 787, STRINGER 8R. REPAIRED FRAME IAW EA.SDR SWAA2015052840124Frame · crackedFRAME CRACKED AT BS 747, STRINGER 8R. REPAIRED FRAME IAW EA.SDR SWAA2015052840123Frame · crackedFRAME CRACKED AT BS 867, STRINGER 8L. REPAIRED FRAME IAW EA.SDR FDEA201505191537Frame · gougedFWD E & E COMPARTMENT BS 231.25, LBL 9 FRAME WEB HAS A GOUGE. REPAIRED IAW EA F-5310-T0317393. REPAIR CLASSIFIED AS MAJOR.SDR ASOA2015060513063Frame · corrodedFRAME BS 605, LOWER FLANGE IS CORRODED STRINGERS 22-23L. REMOVED AND REPLACED IAW SRM 51-42-06.SDR KO0R201505180048Frame · corrodedCENTER PIT AFT DOOR TORQUE BOX LOWER FRAME AT STATION 1781 AT PIT FLOOR LEVEL HAS CORROSION.SDR ASOA2015060513055Frame · corrodedFRAME BS 280 FOUND CORRODED. REMOVED CORROSION IAW SRM 51-21-06-001-001-A01.SDR IPXA2015052789475Frame · corrodedINSPECTION TYPE:4C, TRANSVERSE FRAME IN CENTER ACCESSORY COMPARTMENT HAS CORROSION FS 6-90 BETWEEN L51L AND L51R. ACCOMPLISHED BLEND REPAIR ON TRANSVERSE FRAME IN CENTER ACCESSORY COMPARTMENT FS 6-90 BETWEEN L51L AND L51R IAW SRM 53-00-00 REPAIR GENERAL.SDR SWAA2015071041713Frame · corrodedRIGHT WING TO BODY SUPPORT FRAME CORRODED AT BS 832 LOWER END. R & R FRAME IAW DWG.SDR SWAA2015070941606Former · corrodedFRAME SHEAR TIE HAS CORRODED AT BS 927, BETWEEN LONGERON 29L TO 29R. REPAIRED FORMER IAW SRM.SDR SWAA2015070841581Frame · corrodedAFT CARGO COMPARTMENT FRAME CORRODED AT BS 927, LONGERON 28R - 29L. REPAIRED FRAME IAW SRM.SDR SWAA2015070141258Former · crackedMAIN CABIN FORMER CRACKED AT BS 1022, LONGERON 14R. REPAIRED FORMER IAW EA.SDR FDEA201505161526Frame · dentedMAIN DECK LT FRAME 74 IS DENTED, OVERHEAD ABOUT STRINGER 12L. REPAIRED FRAME 74, STRINGER 12 LT IAW SRM-53-10-13 FIG 202 & SRM-51-40-44. REPAIR ANGLE FABRICATED ON T15 1136702. REPAIR MUST BE INSPECTED IAW-SRI-53-10-13, PAGE 207 & 208. FIRST INSPECTION AFTSDR SWAA2015060140245Frame · crackedFUSELAGE FRAME CRACKED AT STATION 867, STRINGER 8R. REPAIRED FRAME IAW EA.SDR SWAA2015060140244Frame · crackedFUSELAGE FRAME CRACKED AT STATION 827, STRINGER 8R. REPAIRED FRAME IAW EA.SDR SWAA2015060140243Frame · crackedFUSELAGE FRAME CRACKED AT STATION 747, STRINGER 8R. REPAIRED FRAME IAW EA.SDR SWAA2015060140242Frame · crackedFUSELAGE FRAME CRACKED AT STATION 400, STRINGER 8R. REPAIRED FRAME IAW EA.SDR SWAA2015060140241Frame · crackedFUSELAGE FRAME CRACKED AT STATION 360, STRINGER 8R. REPAIRED FRAME IAW EA.SDR SWAA2015052940211Frame · crackedFUSELAGE FRAME CRACKED AT STATION 540, STRINGER 22L - 23L. REPAIRED FRAME IAW EA.SDR SWAA2015052940210Frame · crackedFUSELAGE FRAME CRACKED AT STATION 727A, STRINGER 8R. REPAIRED FRAME IAW EA.SDR SWAA2015052940209Frame · crackedFUSELAGE FRAME CRACKED AT STATION 867, STRINGER 8L. REPAIRED FRAME IAW EA.SDR SWAA2015052940208Frame · crackedFUSELAGE FRAME CRACKED AT STATION 827, STRINGER 8L. REPAIRED FRAME IAW EA.SDR SWAA2015052940207Frame · crackedFUSELAGE FRAME CRACKED AT STATION 787, STRINGER 8L. REPAIRED FRAME IAW EA.SDR SWAA2015052940206Frame · crackedFUSELAGE FRAME CRACKED AT STATION 400, STRINGER 8L. REPAIRED FRAME IAW EA.SDR SWAA2015052840145Frame · crackedFRAME CRACKED AT BS 480, STRINGER 8R. REPAIRED FRAME IAW EA.SDR SWAA2015051939826Frame · crackedFRAME OF BELLY FAIRING STRUCTURE CRACKED AT BS 500D RT SIDE. R & R FRAME IAW DWG.SDR CALA2015051500400Frame · crackedCABIN FRAME STATION 800 IS CRACKED AT FASTENER BETWEEN STRINGER 8R & 9R. FABRICATED & INSTALLED REPAIR CHANNELS 1 & 2 AT STATION 800 BETWEEN STRINGER 8R & 9R IAW SRM 53-00-07.SDR DALA2017011900491Failsafe · crackedINSPECTION SHOWS CRACK INDICATION RT SIDE FAILSAFE FITTING AND REPAIRED.SDR DALA2015071004275Frame · gougedMAIN CABIN FRAME , BS 1280, HAS TWO GOUGES AT THE WINDOW BELT, BETWEEN S11-13R. BLENDED OUT AREAS IAW SRM 51-10-02 AND FOUND OUT OF LIMITS IAW SRM 53-00-07. REPAIR IAW ERA 532895-14AD, REV "0".SDR ASOA2015060513060Frame · corrodedCORROSION ON FRAME AT FS 319.7 BETWEEN STR 25L AND 25R. FOUND CORROSION TO BE IN TWO ELEMENTS AND OUT OF LIMITS IAW SRM 53-00-00 FIG 102, SHEET 2. REMOVED FRAME SECTOR IAW SRM 51-42-06 AND SRM 51-42-21 AND INSTALLED IAW SRM 51-42-06, SRM 51-42-21 AND DWG 601SDR ASOA2015060513059Frame · corrodedCORROSION ON FRAME AT BS 310 BETWEEN STR 25L AND 25R. FOUND CORROSION TO BE IN TWO ELEMENTS AND OUT OF LIMITS IAW SRM 53-00-00 FIG 102, SHEET 2. INSTALLED NEW FRAME SECTOR IAW SRM 51-42-06, 51-42-21 AND SRM TR 51-32.SDR ASOA2015060513058Frame · corrodedCORROSION ON FRAME AT BS 295 AT STRINGER 26L. FOUND CORROSION ON FRAME AT FS 295 AT STR 26L TO BE IN 2 ELEMENTS AND OUT OF LIMITS IAW SRM CH 53-00-00, FIG 102, SHEET 2. COMPLIED WITH EA 32-2015-197 IAW SRM 51-21-16-00 AND 51-21-11-00. EA 32-2018-197 HAS BESDR ASOA2015060513057Frame · corrodedFOUND MINOR CORROSION AROUND FASTENERS AND DRAIN HOLE LOCATIONS AT FS 559+96 BETWEEN STR 26L AND 26R. EA 37-2015-028 HAS BEEN ACCOMPLISHED.SDR ASOA2015060513056Frame · corrodedFOUND MINOR CORROSION AROUND FASTENERS AT BS 559.00+16 BETWEEN STR 27 AND 26R. EA 37-2015-029 HAS BEEN ACCOMPLISHED AND ALL STEPS HAVE BEEN DOCUMENTED AND SIGNED FOR ON A NON-ROUTINE WORK CARD.SDR ASOA2015060413026Frame · corrodedCORROSION ON FRAME AT FS 364.00 BETWEEN STR 25 - 27R. FOUND CORROSION ON FRAME AT FS 364 AT STR 27 TO 25R TO BE IN 2 ELEMENTS AND OUT OF LIMITS IAW SRM CH 53-00-00, FIG 102 SHEET 2. C/W STS EA 32-2015-208. EA 32-2015-208 REV 1R HAS BEEN ACCOMPLISHED AND ALLSDR ASOA2015060413005Frame · corrodedCORROSION ON FRAME AT BS 349 BETWEEN STRINGERS 25L AND 25R. FOUND CORROSION TO BE IN TWO ELEMENTS AND OUT OF LIMITS IAW SRM 53-00-00 FIG 102, SHEET 2. LOCATED AND DRILLED NEW SERVICEABLE FRAME SEGMENT IAW SRM 51-40-11. REMOVED CORROSION IAW SRM 51-42-06 ANSDR ASOA2015060413004Frame · corrodedCORROSION ON FRAME BS 333 BETWEEN STR 25L AND 25R. FOUND CORROSION TO BE IN 2 ELEMENTS AND OUT OF LIMIT IAW SRM 53-00-00 FIG 102, SHEET 2. REMOVED LOWER FRAME IAW SRM 51-42-06. INSTALLED NEW SERVICEABLE LOWER FRAME IAW SRM 51-42-06 AND SRM 51-42-21.SDR SWAA2015060140240Frame · crackedFUSELAGE FRAME CRACKED AT STATION 986, STRINGER 20R. REPAIRED FRAME IAW EA.SDR IPXA2015060689871Frame · dentedINSPECTION TYPE: C-8, FWD CARGO BAY BS 680, STR 23R FRAME DENTED. REPAIRED THE FRAME IAW SRM 53-00-07-2R-5, FIGURE 201, SHEET 4, DETAIL I.SDR IPXA2015060689870Frame · dentedINSPECTION TYPE:C-8, FWD CARGO BAY RT BS 740, STR 25R, FRAME DENTED. REPAIRED THE FRAME IAW SRM 53-00-07-2R-5 FIGURE 201, SHEET 8, DETAIL III.SDR IPXA2015060789911Frame · dentedINSPECTION TYPE:C8, FWD CARGO BAY LT SIDE BS 680 FRAME AT 25L DENTED. REPAIRED DENTED FRAME IN FWD CARGO COMPARTMENT BS 680, STR 25L IAW SRM 53-00-07-2R-5, FIG 501, DETAIL III.SDR 4AER201505120009Frame · corrodedDURING AGING ACFT INSPECTION, FOUND LEVEL 3 CORROSION ON UPPER FLANGE OF FRAME IN AFT CARGO BAY AT FS 947 AT STR 27R.
Back to JASC 5311