JASC 5311
Service difficulty reports · 61,549
Reports filed under 5311 · Fuselage Main, Frame, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASOA2015051312805Frame · crackedAT FRAME BS 193, THE FLOOR OF THE FORWARD EQUIPMENT COMPARTMENT IS CRACKED. COMPLIED WITH EC/TC REO 670-53-11-509 AND REO 670-53-11-509, REV B, DATED 01-28-2014.SDR SWAA2015050639358Frame · corrodedFRAME CORRODED AT BS 440, RBL 20. REPAIRED FRAME IAW SRM.SDR SWAA2015070641303Frame · crackedFRAME OTBD CHORD CRACKED AT BS 727, STRINGER 18A LT. REPAIRED CHORD IAW EA & DWG.SDR SWAA2015052039885Frame · crackedBULKHEAD LOWER FRAME WEB CRACKED AT BS 727, WL 200 INBD FASTENER HOLE. REPAIRED WEB IAW EA.SDR IPXA2015042488354Frame · corrodedINSPECTION TYPE:4C, LEFT NR 2 A/C BAY BILGE LONGERON SUPPORT AND FRAME SUPPORT HAS LIGHT CORROSION. ACCOMPLISHED BLEND REPAIR ON LT NR 2 A/C BAY BILGE LONGERON SUPPORT AND FRAME SUPPORT IAW SRM 53-00-00, REPAIR GENERAL.SDR DALA2015041802816Frame Splice · corrodedCORROSION ON SPLICE BETWEEN LONGERON PROJECTION 26 AND 27R, BS 1338 AT AFT CARGO COMPARTMENT. SPLICE WAS REPLACED IAW SRM 53-03, FIG 37, 51-10-3 PARA 14 AND 21, 51-30-5. LP 1909271.SDR V0XD20150416105Frame · corrodedCORROSION ON FRAME 333 AT STRINGER 27. CUT OUT CORRODED FRAME 333 FROM STRINGER 25L TO 25R, FABRICATED & INSTALLED REPAIR PARTS IAW REO 670-53-21-799, DATED 30 JAN 2012. WO 80282 WC 2114. REPAIR PARTS FABRICATED IAW REO 670-53-21-799 DATED 30 JAN 2012.SDR 2017FA0000134Frame · crackedTHE LT BS 130 FRAME WAS FOUND CRACKED DURING A PHASE VISUAL INSPECTION. THE CRACK EXTENDED OUTBOARD 2.0 INCH FROM THE INBOARD FLANGE FREE EDGE AT LBL 67. THE FRAME WAS REPLACED.SDR 2017FA0000133Frame · crackedTHE LT BS 130 FRAME WAS FOUND CRACKED DURING A PHASE VISUAL INSPECTION. THE CRACK EXTENDED OUTBOARD 2.0 INCH FROM THE INBOARD FLANGE FREE EDGE AT LBL 67. THE FRAME WAS REPLACED.SDR AALA201505229001Frame · cracked3S CHECK, CRACK ON WEB OF FRAME 35, FWD FACE, LOCATED AT LT STRINGER 30 IN FWD CARGO COMPARTMENT. PERFORMED REPAIR ON WEB IAW EA 250276.SDR AALA20150418005Frame · crackedLEFT MLG CRACK IN FRAME 984 AT AFT OTBD CORNER OF WW NEXT TO FLAP BUS CABLE PULLEY BRACKET. SPLICED NEW CHANNEL SECTION IAW SRM 51-70-05 & DWG 5936373.SDR V0XD20150416098Frame · corrodedFRAME 345.00 AT STRINGER 27 IS CORRODED. REPAIRED FRAME 345.00 AT STRINGER 27 BY CUTTING OUT CORRODED AREA & INSTALLING REPAIR PARTS IAW REO 670-53-21-1176 DATED 9 APRIL 2015.SDR AALA20150415004Frame · crackedFRAME CRACKED AT AFT SIDE OF STATION 1418 L2-R. INSTALLED DOUBLER IAW SRM 53-03-00-001, 53-01-00-001 & AARD 53-10-00-15.SDR AALA20150415002Frame · crackedFRAME CRACKED AT STATION 1401 L1. CUT OUT DAMAGED AREA, INSTALLED FILLER & DOUBLER IAW AARD 53-10-00-17.SDR FDEA201504141228Frame Splice · gougedAFT CARGO COMPARTMENT, BS 1520 24R FRAME SPLICE HAS GOUGED. REMOVED AND REPLACED IAW DWG 146N1017 SHT 3 REV. D, SPLICE FABRICATED IAW DWG 146N1042 SHT 1 REV A. REPAIR CLASSIFIED MAJOR IAW GMM 6-2-100.SDR ASOA20150414097Frame · crackedDURING C-CHECK. FRAME 10 CRACKED UNDER RT DV WINDOW. REPAIRED FRAME 10 IAW SRM 51-40-02. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA2015050412750Frame · corrodedCORROSION ON FRAME AT FS 605.00, STR 27. REMOVED CORROSION ON FS 605. FRAME BETWEEN STR 25L AND 25R IAW SRM 51-21-06. FS 605.00 FRAME FOPUND TO BE OUT OF LIMITS IAW SRM 53-00-00, TRR 53-29. REMOVED OLD FS 605.00 FRAME SECTOR, PN:601R36026-27 BETWEEN FACTORY SDR DALA2015041502786Frame · crackedTAIL INTERIOR, CANTED B-FRAME BS 1520, AFT WEB HAS A CRACK. COMPLY WITH PRI 535069-14.SDR DALA2015041402757Frame · crackedRT FUSELAGE MAIN FRAME CRACKED AT FS 674. REPLACED FRAME AT 674 IAW AMDS 5310-01436-03B. LP 1902809.SDR ASOA2015050612756Frame · corrodedFS310 AT STR 25RT IS CORRODED. REMOVED CORROSION FROM FRAME STA 295, STR 25R IAW SRM 51-21-06-001-001-A01. BLEND AREA IS OUT OF LIMITS IAW SRM 53-21-06-101-002-A02, DAMAGE IS ON 2 ELEMENTS IAW NOTE 1. COMPLIED WITH EA 32-2015-148. RECEIVED EC/TC EA 32-2015SDR ASOA2015042912699Frame · corrodedFRAME BS 319, FWD SIDE CORRODED 26L-26R. REMOVED CORROSION ON FRAME IAW SRM 51-21-06-001-001-A01.SDR ASOA2015042912698Frame · corrodedFRAME BS 333 FWD SIDE CORRODED STR 27. REMOVED CORROSION IAW SRM 53-21-06-001-001-A01 AND 51-12-00-001-001-A01. NO DAMAGED ALLOWED ON FRAME IAW SRM 53-21-06-101-006-A02. COMPLIED WITH ECTC EA 32-2015-144.SDR 2017FA0000140Frame · crackedTHE RT BS 117 FRAME WAS FOUND CRACKED DURING A PHASE VISUAL INSPECTION. THE CRACK EXTENDED OUTBOARD 5.0 INCH FROM THE INBOARD FLANGE FREE EDGE AT RBL 67. THE FRAME WAS REPLACED.SDR 2017FA0000139Frame · crackedTHE RT BS 117 FRAME WAS FOUND CRACKED DURING A PHASE VISUAL INSPECTION. THE CRACK EXTENDED OUTBOARD 5.0 INCH FROM THE INBOARD FLANGE FREE EDGE AT RBL 67. THE FRAME WAS REPLACED.SDR DALA2016112209108Frame · corrodedOUT OF LIMITS CORROSION SPOTS FOUND ON THE INBD FLANGE OF FRAME 20 RT. REPAIRED IAW ER/A.SDR SWAA2015051139564Frame · crackedRIGHT FRAME CRACKED AT BS 696, UPPER RADIUS OF THE TAB. R & R FRAME IAW DWG.SDR SWAA2015050639356Frame · crackedFRAME WEB CRACKED AT BS 440, STRINGER 24R. R & R FRAME IAW SRM.SDR ASOA2015042912695Frame · corrodedFRAME BS 310 CORRODED FWD SIDE STR 27-26R. REMOVED CORROSION FROM FWD SIDE IAW SRM 51-26-06-001-001-A01.SDR ASOA2015042912694Frame · corrodedFRAME BS 295 CORRODED BOTH SIDES AT STR 27. REMOVED CORROSION FROM FRAME BOTH SIDES IAW SRM 51-21-06-001-001-A01. DAMAGE FOUND TO BE OUT OF LIMITS IAW SRM 53-21-06-101-002-A02. COMPLIED WITH EA 32-2015-147.SDR SWAA2015042738999Frame · crackedFUSELAGE FRAME CRACKED AT BS 907, STRINGER 8L. REPAIRED FRAME IAW EA.SDR SWAA2015042438945Frame · crackedFRAME CRACKED AT BS 500C, STRINGER 8L. REPAIRED FRAME IAW EA.SDR SWAA2015042038715Frame · crackedFUSELAGE FRAME CRACKED AT BS 559, STRINGER 8L. REPAIRED FRAME IAW EA.SDR SWAA2015042038714Frame · crackedFUSELAGE FRAME CRACKED AT BS 520, STRINGER 8L. REPAIRED FRAME IAW ACO.SDR SWAA2015041738632Frame · crackedFRAME CRACKED AT BS 827, BETWEEN STRINGER 8R - 9R. REPAIRED FRAME IAW EA.SDR SWAA2015041738631Frame · crackedFRAME CRACKED AT BS 440, BETWEEN STRINGER 8R - 9R. REPAIRED FRAME IAW EA.SDR SWAA2015041538552Frame · crackedFRAME CRACKED AT BS 787, STRINGER 8L. REPAIRED FRAME IAW EA.SDR SWAA2015041538551Frame · crackedFRAME CRACKED AT BS 480, STRINGER 8L. REPAIRED FRAME IAW EA.SDR SWAA2015041538550Frame · crackedFRAME CRACKED AT BS 360, BETWEEN STRINGER 8R - 9R. REPAIRED FRAME IAW EA.SDR SWAA2015041338480Frame · crackedFRAME CRACKED AT BS 727D, STRINGER 8L. REPAIRED FRAME IAW EA.SDR A6WA201542609Frame · dentedFUSELAGE FRAME DENTED AT FS 672.00 ABOVE STRINGER 25R.SDR ASOA20150409088Frame · crackedDURING C-CHECK, FRAME 25 CRACKED AT STR 15R-16R. REPAIRED FRAME 25 IAW SRM 53-00-04. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR WVER0421201500006Frame · chafedFS 1162 FRAME FREE FLANGE IS CHAFED AT STR 7L.SDR CALA2015041393521Frame · corrodedCORROSION AT AFT CARGO COMPARTMENT FRAME AT BS 1460, STRINGER 25R. R & R FRAME AT BS 1460, STRINGER 25R IAW SRM 51-40-02 PAR 7 FIG 12.SDR DALA2015040902699Frame · corrodedCORROSION FRAME Y=1380 LWR SECTION AT AFT ACCESSORIES COMPARTMENT. FRAME TEE WAS REPLACED IAW SRM 51-30-2, 51-30-5, 51-10-4, 51-10-3, PARS 21, 14 & 38. LP 1895919.SDR FDEA201504081167Frame · corrodedAFT CARGO COMPARTMENT STATION 1440, RBL 10 BOTTOM FRAME CORROSION. R & R WITH NEW FRAME IAW DWG NR & 146N1013 SHT 3 REV D. REPAIR CLASSIFIED MAJOR IAW GM 6-2-100.SDR CALA2015040800260Frame · crackedCRACK INDICATION AT STATION 727B RT, BETWEEN STRINGER 8 & 9. PERFORMED AN INTERIM REPAIR IAW ECRA 5310-06473 PART 1. IMITATED A DIP TO READ ACCOMPLISH A PERMANENT REPAIR ON OR BEFORE 4/6/2017. PLANNING TO CONTACT ENGINEERING AFTER 2/6/2017 BUT BEFORE 3/6/20SDR SWAA2015050639353Frame · corrodedAFT CARGO BAY ON FRAME SHEAR TIE CORRODED AT BS 767, BETWEEN STRINGER 27L - 27R. R & R FRAME ASSEMBLY IAW SRM & DWG.SDR ASOA2015042912720Frame · corrodedCORROSION ON FRAME AT FS 364.00 BETWEEN LBL 24 & RBL 24. COMPLIED WITH EA 32-2015-138.SDR ASOA2015042912719Frame · corrodedCORROSION ON FRAME AT FS 330.00 BETWEEN LBL 24 & RBL 24. FOUND CORROSION TO BE LOCATED ON FRAME SECTOR AT FS 333.00 NOT FS 330.00. CORROSION FOUND OUT OF LIMITS IAW SRM 53-00-00. REMOVED CORRODED FRAME IAW SRM 51-42-21 AND 51-42-06. LOCATED AND DRILLED NEWSDR ASOA2015042912718Frame · corrodedCORROSION ON FRAME AT FS 319.70 BETWEEN LBL 24 & RBL 24. FOUND CORROSION ON FS 319.70 FRAME OUT OF LIMITS IAW SRM 53-00-00. REMOVED FS 319.70 LOWER FRAME SECTOR FOR REPLACEMENT IAW SRM 51-42-06 AND 51-42-21. LOCATED, DRILLED AND INSTALLED NEW FS 319.70 LOWE
Back to JASC 5311