JASC 5311
Service difficulty reports · 61,554
Reports filed under 5311 · Fuselage Main, Frame, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 04FDEA01418Frame · chafedMAIN DECK - FRAME FOUND TWO CHAFED MARK AT STA 535 RIGHT BETWEEN 9G NET ATTACH YOKE. DISCREPANT AREAS (2 LOCATIONS) TRIMMED OUT AND REPAIR CARRIED OUT AS PER DWG SRZ-53-503.SDR 04FDEA01416Frame · chafedMAIN DECK FRAME FOUND TWO CHAFED MARKS AT STA 535 LEFT BETWEEN 9G NET ATTACH YOKE. DISCREPANT AREAS (2 LOCATIONS) TRIMMED OUT AND REPAIR CARRIED OUT AS PER DWG SRZ-53-503.SDR SWAA041465Fitting · crackedDURING SCHEDULED C1 CHECK, FOUND FWD ENTRY DOOR UPPER HINGE BOX AFT LEG, CRACKED. REMOVED AND REPLACED FWD ENTRY DOOR UPPER HINGE PER EA.SDR ASAA0480450Frame · corrodedOKC - DURING HV-CHECK, FOUND FRAME IS CORRODED IN AFT CARGO BAY AT FS 1079 AT LONGERON 29R. REMOVED CORROSION AND APPLIED PROTECTIVE TREATMENT PER EA 5310-02365. (M)SDR SIMA200415407Frame · corrodedDURING AN MBV INSPECTION, FRAME 258 WAS FOUND TO HAVE CORROSION BENEATH A PREVIOUS DOUBLER REPAIR. REMOVED THE PREVIOUS DOUBLER, SHIMS, AND FILLER. DOUBLER AND SHIMS INSPECTION AND FOUND TO BE SERVICEABLE. COMPLETELY REMOVED CORROSION BY CUT OUT. PERFORMED SDR 04FDEA01406Frame · corrodedFORWARD PIT APPROX STATION 980 LONGERON 52 FRAME HAS CORROSION. REMOVE CORROSION IAW DC10 SRM 51-21-01 VOL 2, ORIGINAL THICKNESS .071 IAW DC10 SRM 53-13-01 FIG 8 VOL 3. MATERIAL REMOVED .032 INCH, MATERIAL REMAINING .039 INCH. FABRICATED REPAIR PARTS AND INSDR A6WA200440064Frame · crackedRT 718 FRAME FLANGE BETWEEN STRINGERS 11 AND 12 IS CRACKED. REPAIRED RT 718 LOWER FRAME FLANGE AT STRINGERS 11 AND 12 IAW MFG REO 601R-53-61-193 REV A.SDR 2004UALA00497Frame · misinstalledSTATION 178 LT UPPER FRAME WL 243 NO EDGE DISTANCE. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED ANGLE SPLICE REPAIR.SDR SIMA200415408Frame · corrodedDURING AN MBV INSPECTION, THE UPPER FLANGE OF FRAME 272 WAS FOUND TO BE CORRODED BEYOND SRM LIMITS. REMOVED THE EMERGENCY BATTERY PACK MOUNTING BRACKET TO ACCESS THE REPAIR AREA. COMLETELY REMOVED THE CORROSION BY CREATING A 2.5 INCH CUTOUT OF THE UPPER FLANSDR JRAA0520043Beltframe · corrodedDURING A SCID INSPECTION, CORROSION WAS FOUND ON RT BELTFRAME STATION 665.0 AT FLOOR LINE. APPROX. 8.5 INCHES OF THE BELTFRAME IS CORRODED AT THE FLOORBEAM ATTACH POINT. SOME OF THE CORROSION EXTENDS BELOW THE FLOOR LINE. REPAIR IN PROGRESS AT THIS TIME.SDR SIMA200415406Frame · corrodedABI - DURING AN MBV INSPECTION, THE UPPER FLANGE OF FRAME 225 WAS FOUND TO CORRODED BEYOND SRM LIMITS. COMPLETELY REMOVED THE CORROSION BY CREATING A 3.0 CUTOUT OF THE UPPER FLANGE. FABRICATED A REPAIR ANGLE, SPACER AND FILLER PIECE. REPAIR DONE IAW SAAB REPSDR 04FDEA01344Frame · dentedFWD CARGO STA 629 FRAME DENTED LBL 6 STR 28. CUT OUT DAMAGED PORTION OF FRAME AT BS 720 LBL 6 STR 28 AND INSTALLED REPAIR DOUBLER PER SRM 51-40-3.SDR MWEA040080Frame · crackedCANTED FRAME 1388 TOP WEB CRACKED OUTBOARD OF VERTICAL SPAR TANG RIGHT SIDE. FABRICATED AND INSTALLED DOUBLER.SDR USAA040236Frame · corrodedFRAME, 1.100 INCH X 1.00 INCH X 0.62 INCH, CORROSION. REPLACED NEW FRAME IAW SRM.SDR ASAA0480436Frame · corrodedOKC - FOUND DURING C-CHECK, FRAME IS CORRODED AT NUMBER LOCATIONS BETWEEN LONGERON 28L AND 28R AT FS 1079. REMOVED DAMAGED AREA AND INSTALLED DOUBLER AND FILLER PER SRM 53-03. (M)SDR ASAA0410267Frame · crackedFOUND CRACKED FRAME. REPLACED FRAME. (M)SDR AUS20040405Frame · corroded(AUS) LT FUSELAGE FRAME 43 CONTAINED LEVEL 2 CORROSION ON THE FORWARD FACE AT FLOOR LEVEL. DAMAGE WAS LOCATED AT ZONE 20 FRAME 43 STA 726.9 AND WAS 38.1MM (1.5IN) LONG BY 38.1MM (1.5IN) WIDE AND 4.546MM (0.179IN) DEEP. CAUSE OF DAMAGE WAS ASSESSED AS ENVIRONMESDR ASAA0480430Frame · corrodedOKC - DURING HV CHECK, FOUND FRAME IN AFT CARGO PIT AT STATION 1287, LONGERON 29L-28R IS CORRODED. REMOVED DAMAGE AND INSTALLED REPAIR FRAME SEGMENT IAW 53-03. (M)SDR ASAA0480426Frame · corrodedOKC - DURING HV CHECK, FOUND FRAME IN AFT PIT AT STATION 1231, LONGERON 29L-29R IS CORRODED. REMOVED DAMAGE AND INSTALLED REPAIR SPLICE IAW 53-03. (M)SDR UPS04542533Frame · dentedINSPECTION TYPE:C3 FWD CARGO COMPARTMENT BS 680, BETWEEN STR 23 RT AND STR 24 RT, FRAME IS DENTED. REMOVED DAMAGE FROM FRAME, FABRICATED DOUBLER AND INSTALLED PER SRM 51-70-11 FIG 1.SDR COMA0460319Frame · crackedCRACK ON LEFT HAND FS 718 BETWEEN STRINGER 11 AND 12. REPAIRED FRAME BETWEEN STRINGER 11 AND 12 ON CT FS 718.00 IAW REO 601R-53-61-193.SDR 0401119929Frame · crackedDURING M-CHECK FOUND CRACK IN FRAME AT BS 598 L24L. REPAIRED PER EA 99-199088.SDR ASAA0480421Frame · corrodedDURING HV CHECK, FOUND FRAME IN AFT PIT AT STATION 1117, LONGERON 29R TO 29L IS CORRODED. REMOVED DAMAGE AND INSTALLED NEW FRAME IAW 51-30-1. (M)SDR ASAA0480422Frame · corrodedDURING HV-CHECK, FOUND FRAME IN AFT PIT AT STATION 1250, LONGERON 29R TO 28L IS CORRODED. REMOVED DAMAGE AND INSTALLED FRAME REPAIR ANGLES IAW 53-03. (M)SDR ASAA0480401Frame · crackedOKC - DURING C-CHECK, FOUND LEFT WHEEL WELL FAIRING FRAME CRACKED AT FASTENER. REMOVED DAMAGED FRAME AND INSTALLED NEW IAW 51-30-2. (M)SDR ASAA0440131Frame · damagedGYR - FOUND AFT PIT STAITON 787 LEFT SIDE FRAME ZEE ANGLE ATTACHMENT HOLES ARE DAMAGED. REMOVED DAMGAED AREA AT FS 787 LEFT FRAME. FABRICATED REPAIR REF SRM 51-70-11. TREATED, PRIMED AND APPLIED TOPCOAT, REF 51-20-01, AND INSTALLED REPAIR REF 51-40-02. (M)SDR 04FDEA01267Frame · damagedUPPER CARGO COMPARTMENT, RIGHT UPPER FRAME ASSY AT STA 1681 FOUND DAMAGED. UPPER CARGO COMPARTMENT, RIGHT UPPER FRAME ASSY AT STA 1681 CARRIED OUT REPAIR ON DAMAGED AREA AS PER SRM 53-30-00 VOL I FIG 1. FOR REPETITIVE INSPECTION TRACKING, REFER TO FEDEX EA 1SDR SWAA041372Frame · crackedDURING SCHEDULED D-CHECK, FOUND FRAMES AT BS 867, BS 907, STRINGER 8L, AND BS 867, BS 907, STRINGER 8R, CRACKED. REPAIRED FRAME SECTIONS PER SRM.SDR SWAA041370Frame · crackedDURING SCHEDULED D-CHECK, FOUND FRAMES AT BS 727 D, STRINGER 8L, AND BS 747, STRINGER 8R, CRACKED. REPAIRED FRAME SECTIONS PER SRM.SDR ABXA040189Frame · corrodedCORROSION ON FRAME LOWER LEG AT STA 446, LONGERON 30. REPAIRED IAW DC-9 SRM 53-03.SDR ABXA040188Frame · corrodedCORROSION ON FRAME LOWER LEG AT LONGERON 30, STA 408. REPAIRED FRAME IAW DC-9 SRM 53-03.SDR SWAA041371Frame · crackedDURING SCHEDULED D CHECK, FOUND FRAME AT BS 787, STRINGER 8R, CRACKED. REPAIRED FRAME SECTION PER SRM.SDR EIA2004103Frame · crackedCRACK IN OUTER RING CHORD, STA 140R AT STR 20. STOP DRILL CRACK STA 140R AT STR 20. NDT VERIFIED NO CRACK CONDITION REMAINING, ALODINED AND PRIMED. REPAIRED PER EO53-747-1730-04 REV A, AND SB 747-53-2355, FIG 5, PG 52 AND 70-2138-05-0715.SDR UPS04842450Frame · corrodedINSPECTION TYPE:C-2 CORROSION ON FRAME AT FS 180 L35L-35R. REMOVED CORROSION, FOUND BLENDOUT BEYOND ALLOWABLE LIMITS IAW SRM 53-2-0 FIG 1F. FAB -9 DOUBLER, -11 FILLER IAW EO 11728-B AND UPS DWG 53A-011A. INSTALLED PARTS IAW EO AND DWG. ALODINED AND PRIMED IAWSDR SWAA041360Frame · corrodedDURING SCHEDULED 1/4D CHECK, BELT FRAME AT BS 827, RBL 9, CORRODED. REPAIRED BELT FRAME PER SRM.SDR 2004UALA00471Frame · corrodedSTA 380 FRAME HAS CORROSION FROM STR 28L TO 28R. *S/D* MAJOR REPAIR ACCOMPLISHED. INSTALLED REPAIR DOUBLER.SDR 2004UALA00468Frame · dentedAFT PIT LEFT SIDE STA 1400 FRAME BETWEEN STRS 23L AND 26L HAS 2 EACH DENTS ON FRAME. *S/D* MAJOR REPAIR ACCOMPLISHED. FRAME DENTS FROM LOADING OF LUGGAGE. CUT OUT DAMAGED AREA AND FABRICATED ANGLE REPAIR AND INSTALLED IAW SRM.SDR 2004UALA00467Frame · dentedFRAME AT STA 1500 ABOVE STR 26L DENTED. MAJOR REPAIR ACCOMPLISHED. FRAME DENTS FROM LOADING OF LUGGAGE. CUT OUT DAMAGED AREA AND FABRICATED ANGLE REPAIR AND INSTALLED IAW SRM.SDR SWAA041335Frame · crackedDURING SCHEDULED D-CHECK, FOUND FRAMES AT BS 380, STRINGER 8L AND BS 440, STRINGER 8L, CRACKED. REPAIRED FRAME SECTIONS PER SRM.SDR SWAA041342Frame · crackedDURING SCHEDULED D CHECK, FOUND FRAME AT BS 520, STRINGER 8R, CRACKED. REMOVED AND REPLACED FRAME SECTION PER SRM.SDR SWAA041341Frame · crackedDURING SCHEDULED D CHECK, FOUND FRAME AT BS 500 A, STRINGER 8L, CRACKED. REMOVED AND REPLACED FRAME SECTION PER SRM.SDR SWAA041336Frame · crackedDURING SCHEDULED D CHECK, FOUND FRAME AT BS 360, STRINGER 8R, CRACKED. REMOVED AND REPLACED FRAME SECTION PER SRM.SDR HNAA0400054Frame · corrodedSKIN CORRODED UNDER FRAME X252 BETWEEN STR 31S AND 30S, REMOVED AND REPLACED FRAME IAW EO 8-53-04-0315 CLEANED AND TREATED SKIN CORROSION.SDR HNAA0400053Frame · corrodedFRAME X252.7 CORRODED AT STR 31S. INSTALLED NEW FRAME SECTION PER EO8-53-04-0315.SDR HNAA0400052Frame · corrodedFRAME X220 CORRODED AT STRINGER 31S. REMOVED AND REPLACED FRAME & VERTICAL BEAM IAW EO 8-53-04-0316.SDR HNAA0400051Frame · corrodedFRAME X220 CORRODED AT STRINGER 29S. REMOVED AND REPLACED FRAME 220 IAW EO 8-53-04-0316.SDR HNAA0400050Frame · corrodedFRAME AT X 220 CORRODED AT STR 28S. REMOVED AND REPLACED FRAME 220 IAW EO 8-53-04-0316.SDR HNAA0400049Frame · corrodedFRAME X202 CORRODED AT STRINGER 31S.SDR HNAA0400048Frame · inadequateFRAME X240 HAS AN INADEQUATE SPLICE AT STR 33. REMOVED AND REPLACED FRAME AT X240 PER EO 8-53-04-0314, MAJOR REPAIR.SDR AWXA200400505Frame · crackedLCQ - MAJOR REPAIR - DURING C-15 CHECK A .3125 INCH CRACK WAS FOUND IN MAIN CABIN FRAME AT BS 616, LBL 65, BELOW FLOOR LEVEL WL 205. MAINTENANCE CUT OUT DAMAGED SECTION OF FRAME AT BS 616, LBL 65, WL 205; FABRICATED A FILLER AND STIFFENING ANGLE; INSTALLED RE
Back to JASC 5311