JASC 5315
Service difficulty reports · 44,187
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2026031100080Floorbeam · corrodedMAIN DECK CARGO UPON REMOVAL OF FLOOR PANEL FLOOR BEAM AT STATION 2220 LBL 82 FOUND CORRODED. CORRODED FLOOR BEAM AT STATION 2220 LBL 82, REPAIR CARRIED OUT AS PER SRM 53-00-51-2R-3 REPAIR 3 REV 106. NO FURTHER DEFECTS NOTED. PN BAC1505-101049.SDR SWAA2026050482884Floorbeam · corrodedCORROSION FLOORBEAM LOCATED BS 947.5 AND RBL23 WL208.1 AFT GALLEY AND LAV. PERFORMED REPAIR ON FLOORBEAM LOCATED STA947.5 AND RBL23 WL208.1 AFT GALLEY AND LAV IAW EA 26-153-00958.SDR SWAA2026050482886Floorbeam · corrodedCORRODED FLOORBEAM LOCATED BS 947.5 AND LBL51 WL208.1 AFT GALLEY AND LAV CHORD PERFORMED REPAIR ON FLOORBEAM LOCATED STA947.5 BTW BL0 TO LBL 60 WL208.1 AFT GALLEY AREA IAW SRM 53-70-51-2R-5, REPAIR 5, PARAGRAPH 4, AND EA 26-153-00929-WIP5.SDR CALA2026040114991Floorbeam · corrodedAFT CABIN WET AREA STA 986.5 FLOORBEAM HAS CORROSION AT FASTENER HOLE LBL 4.REF AAR NR 100015282. REPAIRED FLOORBEAM LOCATED AT STA 986.5 AT PASSENGER CABIN AFT WET AREA (LBL 4) AS PER SRM 53-00-51-2R-1 .SDR CALA2026033114961Floorbeam · corrodedAFT CABIN WET AREA BS 986.5 FLOORBEAM HAS CORROSION AT FASTENER HOLES AT RBL 23, RBL 30 AND RBL 43. REPAIRED FLOOR BEAM LOCATED AT BS 986.5 AT PASSENGER CABIN AFT WET AREA (RBL 23, RBL 30, RBL 43) AS PER EC/RA 5321-01429.SDR CALA2026033114960Floorbeam · corrodedAFT CABIN WET AREA BS 986.5 FLOORBEAM HAS CORROSION AT FASTENER HOLES AT LBL 30 AND LBL 43. REPAIRED FLOOR BEAM LOCATED AT STA 986.5 AT PASSENGER CABIN AFT WET AREA (LBL 30 AND 43) AS PER EC/RA 5321-01429.SDR SWAA2026050482578Floorbeam · crackedCRACK BRAKE PANEL FLOOR STRUCTURE BS540 AND RBL4 AT PASSENGER CABIN. REPLACED BRAKE PANEL FLOOR STRUCTURE BS540 AND BTW BL0 TO RBL24.75 AT PASSENGER CABIN IAW B737-800 SRM 51-10-02-0G-0 ITEM 9 AND DWG#143A0060; SHEET:64; REV:-.SDR SWAA2026050482579Floorbeam · crackedCRACK BRAKE PANEL FLOOR STRUCTURE BS540 AND LBL4 AT PASSENGER CABIN. ] REPLACED BRAKE PANEL FLOOR STRUCTURE BS540 AND BL0 TO LBL24.75 AT PASSENGER CABIN IAW SRM 51-10-02-0G-0 ITEM 9 AND DWG# 143A0060; SHEET:64; REV:- .SDR SWAA2026050482581Floorbeam · corrodedCORRODED FLOORBEAM BS 986.5, LBL 43, WL 208.1 PASSENGER CABIN. PERFORMED REPAIR ON FLOORBEAM IAW SRM 53-70-51-2R-6.SDR AALA202604146607Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON PASSENGER CABIN FLOOR BEAM UPPER CHORD (T-CAP) AT BS 947 BETWEEN LBL 52 AND RBL 52. REPAIRED CHORD PER SRM 53-70-51-2R-5.SDR CALA2026033014893Floorbeam · corrodedFLIGHT DECK FLOOR SUPPORT UPPER SURFACE CORROSION BS 270 BETWEEN LBL 10" TO RBL 10" REF AAR N/R 100003259 INSTALLED REPAIR ANGLE AND REPAIR STRAP AT FLIGHT DECK FLOOR SUPPORT UPPER STA 270 REF B737-800 SRM 51-40-02-0G-0 & ECRA 5321-01566. INSTALLED REPAIR ASDR CALA2026032414805Floorbeam · corrodedPASSENGER CABIN AFT WET AREA FLOOR STRUCTURE FOUND CORROSION BETWEEN STA. 947.5 AND RBL-20 REF AAR N/R 100013085 REMOVED, FABRICATED NEW REPAIR PARTS (T CHORD, 2 ANGLE S, 2 STRAPS) AND REINSTALLED AT LBL 4 TO RBL 55 STA 947.5 REF B737-700 SRM 51-40-02-0G-0 , SSDR SWIA2026032275673Floorbeam · corrodedAFT CABIN FLOOR STRUCTURE RIGHT BEAM HAS CORROSION ON AND AROUND FASTENER AT FR 87. (C-CHECK RO 04/05/2026)REMOVED AND REPLACED AFT CABIN FLOOR STRUCTURE RH BEAM BETWEEN FR 86-89 REF EMB SRM 51-40-08. SEE CONTINUE CARD FOR WORK PERFORMED. REPLACED WITH FACSDR SWIA2026032176331Floorbeam · damagedAT BS 574, RBL 36 FLOORBEAM HAS A SCRIBE LINE ACROSS THE TOP. REMOVED AND REPLACED FLOORBEAM CAP STRIP AT BS 574 BETWEEN RBL 9 AND RBL 27 IAW SRM 51-42-06, REV-. COMPLIED WITH TASK CARD 51-900-1003-SKY AND DWG. 601R35031 REV. AG.SDR AALA202604148251Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON PASSENGER CABIN FLOOR BEAM UPPER CHORD (T-CHORD) AT BS 947.5 AND RBL 24. REPLACED CHORD PER SRM 53-70-51-2R-5.SDR CALA2026041515401Floorbeam · corrodedCABIN AFT WET AREA HAS CORROSION AT BEAM BS 986.5, LBL 44 UPPER SURFACE FASTENER HOLE. ACCOMPLISHED REPAIR OF THE UPPER T-CHORD SECTION OF THE FLOOR BEAM 986.5" FROM LBL 52" TO RBL 52" PER SRM 53-70-51-2R-4 AND ESR 12 14659-WI-P1. COMPLIANCE WITH THE REQUIREMSDR CALA2026032314738Floorbeam · dentedDENTS ON FLIGHT DECK FLOOR B.S. 259 LBL. 15" - RBL. 4". REPAIR ACCOMPLISHED PER SRM 51-10-51-2R-2 AND DWG 141A0631.SDR ASAA2026031965493Floorbeam · corrodedAFT WET AREA FLOORBEAM 986.5 UPPER REPAIR T-CAP CORRODED RBL 0 TO RBL-45. GROUNDED - YES. REMOVED DAMAGE ON AFT WET AREA FLOORBEAM STA 986.5 REPAIR T-CAP MAX MAT LOSS 100% FOUND TO BE OUT LIMITS. REMOVED AND INSTALLED NEW REPAIR ON FLOORBEAM T-CAP STA 986.5 DBSDR ASAA2026031965261Floorbeam · corrodedAFT WET FLOORBEAM BS 993, LBL 32 TO LBL 45 CORRODED. GROUNDED - YES. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS, REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-40-02-0G-0.SDR REXA2026050700536Floorbeam · corrodedCORROSION ON CROSSBEAM LH AT FS 280.00 CROSSBEAM LH AT FS 280.00 WAS REPLACED PER CRJ 900 SRM 51-42-21-001-001-A01, SRM 51-42-06-001-001-A01 AND SRM 51-42-10-001-001-A01SDR REXA2026050500493Floorbeam · corrodedAFTER REMOVAL OF FLOOR PANEL SUPPORT ANGLE OVER FS 280.00, IT WAS DETECTED CORROSION ON RH CROSSBEAM AT FS 280.00 AT LBL 9.00. CORROSION ON RH CROSSBEAM AT FS 280.00 AT LBL 9.00. WAS EVALUATED OUT OF LIMITS, THEREFORE WAS REPLACED PER CRJ900 SRM 51-10-06-001-0SDR AALA202603254160Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: FLOORBOARD SUPPORT UNDER CABIN FLOOR AT BS 540 AND RBL2 IS CRACKED. INSTALLED CABIN FLOORBOARD PANEL 231XF. PER AMM 53-21-00.SDR AALA202603256168Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: FLOORBOARD SUPPORT UNDER CABIN FLOOR AT BS 540 AND LBL 2 IS CRACKED. INSTALLED CABIN FLOORBOARD PANEL 231UF. PER IAW AMM 53-21-00.SDR CALA2026032014700Floorbeam · corrodedMAIN CABIN, FLOOR AREA, RH SIDE, APPROX STA.330, PANEL 222AF CUTOUT, BEAM FLOOR, UPPER SURFACE HAS CORROSION. NR#136805 FLOORBEAM AT STA330 PANEL 222AF CUTOUT AREA REPAIRED IAW ECRA 5310-08842. AFTER REMOVING CORROSION ON FLOOR BEAM STA 330 RBL 45.3 WAS FOUN DSDR JR2R20260318120Floorbeam · corrodedEXISTING FLOOR BEAM REPAIR AT FR16 LBL11 CORRODED. REPLACE REPAIRSDR JR2R20260318107Floorbeam · corrodedEXISTING FLOOR BEAM REPAIR AT FR19 LBL11 CORRODED. REPLACE REPAIRSDR SWIA2026031777402Floorbeam · crackedCOCKPIT FLOORBEAM AT APPROX FS 28000 LBL12 HAS CRACK TRANS 31900501 C-CHECK RO 09302026REPARED COCKPIT FLOORBEAM AT LBL1200 REF CRJ700 SRM 53-11-43-201-003-A01 AND COMPLIED WITH FORM M337 AND TASK CARD 51-900-1002-SKY,SEE CONTINUE CARD FORE MORE DETAILSSDR SWIA2026031777387Floorbeam · crackedCOCKPIT FLOORBEAM AT APPROX FS 28000 RBL12 HAS CRACK. INSTALLED REPAIR PARTS FOR COCKPIT FLOORBEAM AT RBL1200 REF SRM 53-11-43-201-003-A01SDR SWAA2026042280597Floorbeam · crackedCRACKED FLOORBEAM BS 967, LBL 50. PERFORMED REPAIR AT FLOORBEAM IAW EA 26-153-00821, AND 26-153-00821, WIP 1, & WIP 2.SDR AALA202604018233Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON PASSENGER CABIN FLOORBEAM UPPER TEE CAP AT BS 947 AND RBL 51. REPLACED UPPER TEE PER SRM 53-70-51-2R-5.SDR AALA202604015064Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON PASSENGER CABIN FLOOR BEAM UPPER TEE CAP AT BS 947 AND RBL 24.75. REPLACED UPPER TEE CAP PER SRM 53-70-51-2R-5.SDR AALA202604015821Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON PASSENGER CABIN FLOOR BEAM UPPER TEE CAP AT BS 947 AND LBL 26. REPLACED UPPER CHORD PER SRM 53-70-51-2R-5.SDR SWIA2026031677447Floorbeam · corrodedLEFT CROSSBEAM AT BS 280 HAS CORROSION. REMOVED AND REPLACED THE CROSSBEAM IAW SRM 51-42-06-001-001-A01, SRM 51-42-21-001-001-A01, SRM 51-42-22-001-001-A01, AND DWG CC670-34010, REV -K.SDR SWIA2026031677426Floorbeam · corrodedRIGHT FLOORBEAM, BS 280 CORRODED. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-42-06-001-001-A01, SRM 51-42-21-001-001-A01, SRM 51-42-22-001-001-A01, & DWG CC670-34010, REV K.SDR REXA2026050700506Floorbeam · crackedCRACK RH FS 280.00 BEAM. RH FS 280.00 BEAM WAS REPLACED PER CRJ 900 SRM 51-42-21-001-001-A01, SRM 51-42-06-001-001-A01 AND SRM 51-42-10-001-001-A01SDR REXA2026041700292Floorbeam · corrodedTHE RH FS 280 FLOOR BEAM IS CORRODED. BEGAN REMOVING CORROSION FROM RH FS 280.00 CROSSBEAM IAW CRJ900 SRM 51-21-06-001-001-A01. PART IS HEAVILY CORRODED FROM BL0 TO RBL9 WITH MORE THAN 50% MATERIAL LOST AND DAMAGE STILL PRESENT. CROSSBEAM REQUIRES REPLACEMENTSDR REXA2026041600289Floorbeam · corrodedTHE LT FS 280 FLOORBEAM CORRODED REMOVED CORROSION FROM LT FLOORBEAM IAW SRM 51-21-06-001-001-A01. PART IS HEAVILY CORRODED FROM BL0 TO LBL9 WITH MORE THAN 50% MATERIAL LOST & DAMAGE STILL PRESENT. LOCATED & DRILLED A NEW FLOORBEAM IAW SRM 51-40-11-001-001-A0SDR SIMA20260314003Floorbeam · corrodedRIGHT FLOORBEAM CORRODED, Y+276 AFT OF FRAME FR 90 (MAJOR REPAIR). BLENDED CORROSION ON RT FLOORBEAM IAW SRM 51-10-03. BLENDED AREA MEASURES (INTERCOSTAL - W =1.3", L = 2.0", H = 010".) ORIGINAL MATERIAL THICKNESS OF .040, (ANGLE - W = .8", L = 2.- 0", H = .0SDR N6WA2026031603Floorbeam · damagedFLOOR BEAM RBL 9.00 UPPER INBRD FLANGE DAMAGED TO NUTPLATE HOLE AT FS1031 - 1051.3. PERFORMED PERMANENT REPAIR AT FLOOR BEAM RBL 9.00 UPPER INBRD FLANGE IAW GOJET EO C550-53MR-072-REV-O.SDR AALA202603165591Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN FLOOR SUPPORT BREAK ASSEMBLY PANEL AT BS 540, BETWEEN RBL 0 AND RBL 24. REPLACED BREAK ASSEMBLY PANEL PER AARD 51-00-05-1.SDR SWAA2026041378852Floorbeam · crackedCRACKED FLOOR BEAM ATTACH ANGLE AT PASSENGER COMPARTMENT BS 695; RBL 1; WL 208.<[01] REMOVED AND REPLACED FLOOR BEAM ATTACH ANGLE AT PASSENGER COMPARTMENT BS 695; RBL 1; WL 208 IAW SRM 51-40-02 AND DWG: 273A9111 ID: 0010 REV:-;[02] VERIFIED CORRECTIVE ACTION 1SDR DALA2026031201731Floorbeam · corroded(LOG 1490158) DURING H CHECK IN TPA CORROSION WAS FOUND ON FLOOR BEAM STA 986.5 UPPER T CAP FASTENER HOLES. MAINTENANCE REPAIRED CORROSION PER ERA 632979-14.SDR DALA2026031101692Floorbeam · corrodedSHIP 188 AFT CARGO FLOOR BEAM FOUND CORROSION AT STA 1197+88. CORRECTIVE ACTION: DAMAGED AREA REPAIRED PER B767-300 SRM53-00-07. (1489129)SDR REXA2026041500287Floorbeam · corrodedLH FS 280.00 CROSSBEAM IS CORRODED FROM LBL0 TO LBL9. LOCATED AND DRILLED NEW LH FS 280.00 CROSSBEAM P/N:CC670-34094JP-1S IAW SRM 51-40-11-001-001-A01. INSTALLED NEW LH FS 280.00 CROSSBEAM P/N :CC670-34094JP-1S IAW CRJ900 SRM 51-42-13-001-001-A01. AND CRJ900 SSDR SWAA2026041378521Floorbeam · corrodedCORROSION ON BS328 FLOOR BEAM UPPER FLANGE RBL44; WL208. CORROSION ON BS328 FLOOR BEAM UPPER FLANGE RBL44; WL208WILL BE REPAIRED ON CUSTOMER CARD TTG8Q01AXDK2.;[02] VERIFIED CORRECTIVE ACTIONSDR SWAA2026040978522Floorbeam · corrodedCORROSION ON BS328 FLOOR BEAM UPPER FLANGE RBL23; WL208<[01] REPAIRED BS328 FLOOR BEAM UPPER FLANGE RBL23; WL208 I.A.W SRM 53-10-51-2R-7;[02] VERIFIED CORRECTIVE ACTIONSDR REXA2026032000243Floorbeam · corrodedRT BS 280 CROSSBEAM IS CORRODED FROM RBL 0 - RBL 9. CROSSBEAM FOUND TO BE HEAVILY CORRODED AT MULTIPLE AREAS WITH MORE THAN 50% MATERIAL LOST. NO ALLOWABLE DAMAGE PROVIDED IN SRM. PART REQUIRES REPLACEMENT. REMOVED DAMAGED CROSSBEAM IAW SRM 51-42-06-001-001-ASDR REXA2026031300241Floorbeam · crackedRH COCKPIT FLOORBEAM IS CRACKED AT FS 280.00. CENTER COCKPIT FLOOR BEAM AT RBL 12.00 - REPAIRED IAW SRM 53-11-43-201-003-A01 TYPE 4.SDR SWAA2026041677956Floorbeam · corrodedCORROSION ON FLOORBEAM, BS 947.5, RBL 51, WL 208.1. REPAIRED THE FLOORBEAM IAW SRM 53-70-51-2R-5, REPAIR 5, ALTERNATIVE 2, AND EA 26-153-00786.SDR SWAA2026040978099Floorbeam · corrodedCORROSION ON BS947 FLOOR BEAM UPPER FLANGE LBL49; WL208<[01] REPAIRED BS947 FLOOR LBL 49; WL208 I.A.W SRM 53-70-51-2R-5 REPAIR 5.;[02] VERIFIED CORRECTIVE ACTION
Back to JASC 5315