SDR FDEA2019040850763Floorbeam · crackedMAIN CABIN FLOOR BEAM -STA..580 LBL 45.5 HAS A CRACK IN UPPER AFT FLANGE OF STUB BEAM FITTING. COMPLIED WITH FED-EX EA. #F-5310-T0346128 P1, FUSELAGE- MAIN FRAME- STA.580 FLOOR BEAM SPLICE SEGMENT UPPER AFT FLANGE CRACK REPAIR.SDR SWAA2019050132093Floorbeam · corrodedAFT CARGO FLOOR SUPPORT CORRODED AROUND NUT PLATE HOLES AT BS. 887, BETWEEN RBL 0 TO RBL 21. R&R SUPPORT STRAP PER SRM.SDR ASAA201904290152Floorbeam · corrodedPASSENGER COMPARTMENT FLOOR 986.5 FLOOR BEAM UPPER SURFACE CORRODED AT FASTENER HOLE GIRT BAR FITTING. GROUNDED - YES. REPAIRED 986.5 FLOOR BEAM UPPER SURFACE HOLE GIRT BAR FITTING IAW ALASKA EA: 800-53-EA-21508W=1.5" O=.150 R=.110 L=2.0" D= .040.SDR ASAA2019042904151Floorbeam · corrodedPASSENGER COMPARTMENT FLOOR WET AREA AT STA 947.5 HAS CORROSION. GROUNDED - YES. REPAIRED 947.5 FLOOR BEAM IAW B737-800 SRM 53-70-51-2R-5 AND ALASKA AIRLINES EA 800-53EA-21558.SDR ASAA2019042904150Floorbeam · corrodedPASSENGER COMPARTMENT FLOOR BEAM STA 294 HAS EVIDENCE OF CORROSION. GROUNDED - YES. REPAIRED FLOOR BEAM AT STA 294 IAW ALASKA E.A 800-53EA-21495W:1" O:.094" R:.065" L:1" D: .029".SDR ASAA2019042549134Floorbeam · corroded986 FLOOR BEAM AT LEFT GIRT BAR ATTACH HOLE HAS AREA OF CORR. GROUNDED - YES. REPAIRED 986 FLOOR BEAM L/H SIDE IAW B737 800 SRM 53 70 51 2R 4 REPAIR 4 W 1.5 O .150 R .057 L 2 D .093.SDR ASAA2019041749011Floorbeam · corrodedPAX COMPARTMENT FLOOR WET AREA AT STA 312 HAS EVIDENCE OF CORR. GROUNDED - YES. REPAIRED FLOOR BEAM IAW 737 800 SRM 53 10 51 2R 15 W 1" O .125" R .099" L 2" D .026".SDR DALA2019040852303Floorbeam · corrodedSHIP 6702 MAIN CABIN STA 324 RBL 49 CORROSION ON FLOOR BEAM T CHORD. CORRECTIVE ACTION: FOUND TO BE OUT OF LIMITS REF SRM. REPAIRED FLOOR BEAM IAW B757 SRM. (1016066)SDR ASAA2019041739005Floorbeam · crackedPAX COMPARTMENT STA 540 BL 0 BL 24.82L PANEL BREAK CRACKED. GROUNDED - YES. REMOVED AND REPLACED 1EA PANEL BREAK AT STA 540 BL 0 BL 24.82 IAW B737 800 SRM 51 40 02 0G 0 PG 6 STEP D 1-6.SDR AALA201904043003Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT WET AREA FLOOR BEAM AT BS 947 BETWEEN LBL 7.8 AND LBL 53. REPAIRED FLOOR BEAM PER SRM 53-70-51-2R-5.SDR SWAA2022030726444Seat Track · corrodedSUPPLEMENTAL INFORMATION: ***CORROSION*** IN WELL OF SEAT TRACK CROWN STA 496-498; 500+5-6; 500A+9-500B; 500C+7-11; 520 ON TOP OF CROWN; LBL 45; WL 208. (MARKED) / REMOVED CORROSION ON SEAT TRACK CROWN AT STA 496-498. 500+5-6; 500A+9-500B; 500C+7-11; 520 ON TOSDR CA190402012Floorbeam · corroded(CAN) DURING HMV INSPECTION 425-536108 GVI 10000-1, CORROSION WAS FOUND IN MULTIPLE LOCATIONS ON FLOOR BEAM S53672409218 AT FRAME 40. CORROSION WAS REMOVED BY BLENDING AND THE REMAINING MATERIAL THICKNESS WAS FOUND UNDER LIMITS IN SEVERAL LOCATIONS. REFERENCE SDR SWIA2019050845862Floorbeam · corrodedFLOORBEAM FS409+10 €“ FS409+40 RBL9 CORRODED AT FASTENER HOLE LOCATIONS. (C-CHECK) RO: 05/07/2019 REMOVED AND REPLACED FLOORBEAM CAP AT FS409.00+5 - FS409.00+42 IAW SRM AND REO.SDR AALA201904089016Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD WET AREA FLOOR SUPPORT ANGLE CLIP AT FR 20 AND -Y1650. REPLACED FLOOR SUPPORT ANGLE CLIP PER SRM 53-11-14 AND 51-42-11.SDR CA190403010Floorbeam · corroded(CAN) 1-OFF CORROSION DAMAGE TO FLOOR BEAM OUTBOARD FLANGE DIMENSIONS POST BLEND OUT ARE AS FOLLOWS: 0 1.625`L X 1.090`W X 0.035` MIN. REMAINING THK (0.060` NOM THK, REF) (TC# 20190403010)SDR SWIA2019050845864Floorbeam · corrodedFLOORBEAM CORRODED AROUND NUT PLATE LOCATIONS FS610 €“ FS620 LBL27. (C-CHECK) RO: 05/07/2019 COMPLIED WITH PERMANENT REPAIR FLOORBEAM CORROSION AROUND NUT PLATE LOCATIONS FS610 €“ FS620 LBL27 IAW REO.SDR SWIA2019050845861Floorbeam · corrodedFLOORBEAM CORRODED AROUND NUT PLATE LOCATIONS FS569 €“ FS610 LBL27. (C-CHECK) RO: 05/07/2019 REPLACED FLOORBEAM FS569 - FS610 LBL27 WITH NEW P/N 601R35031-263 IAW REO.SDR SWIA2019050845854Floorbeam · corrodedFLOORBEAM CORRODED AROUND NUT PLATE LOCATIONS FS561 €“ FS569 LBL27. (C-CHECK) RO: 05/07/2019 REMOVED AND REPLACED NEW FLOORBEAM LBL 27 FROM FS 574 TO FS 559+24 IAW REO.SDR SWAA2019042631915Floorbeam · corrodedBS 986 FLOOR BEAM CORRODEC AT RBL 36-43 AND LBL43 WL208. / REPAIRED FLOORBEAM IAW ER & SRM 53-70-51-2R-4.SDR AALA201904109024Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT GALLEY FLOOR BEAM BETWEEN FR 66 AND FR 68 AT +Y1225. REPLACED FLOOR BEAM PER SRM 51-72-11.SDR REXA201904090424Floorbeam · crackedINITIAL INSPECTION: CRACK ON FLOOR BEAM IN STA. FS= 280 12RBL AT PAX CABIN FWD WET AREA. (W1) (CPAX)
FLOOR BEAM IN STA. FS= 280 12RBL AT PAX CABIN FWD WET AREA WAS REPAIR PER REO 690-53-11-1127.REV --SDR SWIA2019050845838Floorbeam · corrodedCORROSION ON FLOORBEAM INBOARD FLANGE AT NUTPLATE, LOCATED 2.0" AFT OF FS 409.00+16, RBL9. (C-CHECK) RO: 05/07/2019 PERFORMED SPLICE REPAIR OF FLOORBEAM IAW SRM.SDR ASAA2019040588886Floorbeam · corrodedFLOOR BEAM STA 986 HAS MULTIPLE SPOTS OF CORR ACROSS LENGTH OF BEAM. GROUNDED - YES. CUT OUT DAMAGE AND ACCOMPLISHED PERMANENT REPAIR OF STA 986 FLOOR BEAM UPPER CAP IAW B737 800 SRM 53 70 51 2R 4 W 2 O .150 R .118 L 6 D .032.SDR KCSA201903271064Floorbeam · corrodedMD-3, AFT PIT STATION 1580, LBL APPRX 72 TO LBL APPRX 100 HAS CORROSION ALONG FLOORBEAM UPPER CHORD OF MAIN DECK.SDR KCSA201903271063Floorbeam · corrodedFLOORBEAM CORD @ STA 2240 BBL 84 L WL 199 IS CORRODED.SDR KCSA201903271062Floorbeam · corrodedFLOORBEAM FASTENER HOLES SHOW EVIDENCE OF CORROSION @ STA 980, BBL 13 TO 25 LEFT, WL 199.SDR KCSA201903271058Floorbeam · corrodedEVIDENCE OF CORROSION ON UPPER CHORD OF MAIN DECK FLOORBEAM IN MULTIPLE SPOTS STA 1840 LBL42 TO LBL 67.SDR SWAA2019050732348Floorbeam · crackedFLOORBEAM CRACKED AT BS. 328, RBL 23. REPAIRED FLOORBEAM PER SRM.SDR REXA2019040836380Floorbeam · crackedFLOOR BEAM CLIP AT FS484.00 AND LBL36 IS CRACKED.
REMOVED AND REPLACED CLIP IAW BOMBA REO 601R-53-41-059 REV B AAR SM 107SDR DALA2019032802027Floorbeam · corrodedSHIP 6702 MAIN CABIN STA 324 RBL 49 CORROSION ON FLOORBEAM T CHORD. CORRECTIVE ACTION: CORROSION FOUND OUT OF LIMITS IAW SRM. REPAIRED FLOOR BEAM IAW SRM. (1004690)SDR KCSA201903261055Floorbeam · corrodedEVIDENCE OF CORROSION ON UPPER CHORD OF MAIN DECK FLOOR BEAM STA 1500 APPROX LBL 80 TO 100.SDR CA190327007Floorbeam · corroded(CAN) DURING HMV INSPECTION, CORROSION FOUND ON FLOOR BEAM AT FRAME 33, P/N S53372411200, BETWEEN LBL 13 AND LBL 38. WO 33424191 MR 00090, INSPECTION TASK CARD 425-536108-GVI-10000-1.SDR F3LA2019040800033Floorbeam · corrodedFLOORBEAM Y1292 AT FR68 CORRODED. REMOVED AND REPLACED FLOORBEAM Y1292 AT FR68 IAW SRM 51-72-11.SDR F3LA2019040800031Floorbeam · corrodedFLOORBEAM -Y1292 FR68 CORRODED TWO PLACES AT SPLICE FASTENERS. REMOVED AND REPLACED FLOOR BEAM AT FR68 -Y1292 IAW A319 SRM 51-72-11./END/SDR AALA2019041659028Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOOR BEAM AT FR 12 AND -Y81. REPLACED FLOOR BEAM PER SRM 51-72-11.SDR AALA2019041659027Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOOR BEAM AT FR 16 AND +Y503.5. REPLACED FLOOR BEAM PER SRM 51-72-11.SDR AALA2019041659026Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOOR BEAM AT FR 16 AND +Y765. REPLACED FLOOR BEAM PER SRM 51-72-11.SDR AALA2019041659025Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOOR BEAM AT FR 16 AND +Y940. REPLACED FLOOR BEAM PER SRM 51-72-11.SDR IPXA2019040140655Floorbeam · corrodedINSPECTION TYPE:C12CORROSION ON THE FLOOR BEAM OF MAIN DECK FLOOR STRUCTURE ON STA 266.5,LBL 53,WL200.REPAIR I.A.W. 767-300F SRM 53-00-51 ALLOWABLE DAMAGE 1 REV.73.01SDR SWAA2019050632344Floorbeam · corrodedAFT CARGO BAY FLOOR SUPPORT CORRODED AT BS. 767+6, BETWEEN LBL 17 TO RBL 13. R&R FLOOR SUPPORT IAW SRM AND DWG.SDR SWAA2019050632343Floorbeam · corrodedAFT CARGO BAY FLOOR SUPPORT CORRODED AT BS. 887, BETWEEN RBL 20 TO LBL 7. R&R FLOOR SUPPORT IAW SRM AND DWG.SDR SWAA2019050232194Floorbeam · corrodedFLOORBEAM CORRODED AT BS. 986, LBL 40. R&R UPPER TEE CAP PER SRM AND EA.SDR SWAA2019043031888Floorbeam · corrodedAFT CARGO BAY FLOOR RAIL AT BS. 767+6, LBL 17. / R&R FLOOR RAIL IAW SRM AND DWG.SDR SWAA2019043031887Floorbeam · corrodedAFT CARGO BAY FLOOR RAIL CORRODED AT BS. 767+6, LBL 12. / REPAIRED FLOOR BEAM PER EA.SDR SWAA2019043031886Floorbeam · corrodedAFT CARGO BAY FLOOR RAIL CORRODED AT BS. 767+6, RBL 7. / REPAIRED FLOOR BEAM PER EA.SDR SWAA2019043031885Floorbeam · corrodedAFT CARGO BAY FLOOR RAIL CORRODED AT BS. 767+6, RBL 2. / REPAIRED FLOOR BEAM PER EA.SDR SWAA2019042331889Floorbeam · corrodedCABIN FLOOR BEAM CORRODED AT RBL 3-45, STA 986, WL 208. / REPAIRED BEAM PER SRM.SDR REXA2019040832363Floorbeam · corrodedFORWARD CABIN FLOOR SUPPORT -280- BEAM TOP CENTER CORRODED
REMOVED AND REPLACED FWD CABIN FLOOR SUPPORT 280 BEAM, TOP CENTER ANGLES I.A.W. CRJ-200 SRM 51-42-06, 51-42-10.SDR REXA2019040821352Floorbeam · crackedFLOOR BEAM CLIP AT FS484.00 AND RBL27 IS CRACKED. REMOVED AND REPLACED WITH NEW CLIP AT FS 484.00 AND RBL 27 ON FLOOR BEAM IAW SRM 51-42-21.SDR SWAA2019042632019Floorbeam · corrodedFLOOR BEAM CORRODED AT BS 986, RBL 43- LBL 39, WL 208 / REPAIRED DAMAGED FLOOR BEAM PER ER & SWA EA 1-753-34682 IR