JASC 5315
Service difficulty reports · 44,220
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2012060400398Floorbeam · corrodedCABIN BS 325, RBL 21 TO 31 FLOORBEAM CORRODED. CABIN BS 325 LBL 62 TO RBL 56 FLOORBEAM UPPER FLANGE REPAIRED IAW SRM53-00-51, REPAIR 1, FIG 201, HFEC NO CRACK FOUND.SDR USAA2012062500010Floorbeam · corrodedQ4 CHECK - FLOORBEAM WEB HAS MULTIPLE SCREW HOLES WITH CORROSION AROUND THEM (7" X 0.75" X .020" AREA) AT BS 630, LBL 40.875. REPAIRED IAW EA 103997.SDR SWAA2012061404877Floorbeam · corrodedFLOORBEAM CORRODED AT BS 344, BETWEEN RBL 2 TO LBL 18. REPAIRED BEAM IAW SRM AND AMM.SDR EIAA20120603047Floorbeam · dentedBS 680 RBL 16 WL 304 FLOORBEAM WEB FOUND DENT. DAMAGED AREA OF THE WEB CUT OUT AS PER B747 SRM 53-00-31, REPAIR PARTS MADE AS PER SRM 53-00-051 FIG 201, ALODINE AS PER SRM 51-10-02, PRIMED AS PER SOPM 20-41-02 REPAIR PARTS TO WEB INSTALLED AS PER B747 SRM 53-SDR FDEA201206032066Floor Support · corrodedMAIN DECK CARGO FLOOR SUPPORT UPPER FLANGE FOUND CORRODED BETWEEN FR12-13 , Y730. REMOVED CORRODED FLOOR SUPPORT IAW SRM 51-40-21. DRILLED FASTENER HOLES ON THE NEW FLOOR SUPPORT IAW SRM 51-40-44. INSTALLED THE NEW FLOOR SUPPORT IAW SRM 51-40-21. APPLIED FSDR CALA2012060400396Floorbeam · corrodedBS 947, FLOORBEAM HAS SURFACE CORROSION BETWEEN RBL49-53 REPAIRED FLOORBEAM IAW ECRA 5321-01798 AND SRM 53-70-51, REPAIR 5.SDR SWAA2012070205488Floorbeam · crackedLONGITUDINAL FLOORBEAM UPPER CHORD CRACKED BETWEEN BS 660 TO BS 680, LBL 24.5. REPAIRED CHORD IAW EA AND EO.SDR AALA20120618006Floorbeam · corrodedCORROSION ON FLOORBEAM 1640 AT SCREW HOLES. ACCOMPLISHED SPLICE REPAIR PER EA B757-53-024162.SDR FDEA201206022059Floorbeam · misrepairedFLOORBEAM MISREPAIRED. REPAIRED PER SRM 53-10-15 FIG 203 SHEETS 1-2 PG'S 245-252.SDR USAA2012060700006Floorbeam · corroded2S CHECK - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM AT FR70, -Y160. REPLACED FLOORBEAM AT FR70, -Y160 IAW A319 SRM 51-74-14 FIG 102, 51-42-11, 51-75-12.SDR CALA2012060400394Floorbeam · corrodedFLOORBEAM 344 HAS CORROSION BL-0 TO RBL-23. REPAIRED FLOORBEAM STA 344 IAW ECRA-5311-01555.SDR C77A20120603009Floorbeam · corrodedRT SUPPORT ON CROSSBEAM AT FRAME 86 BROKEN NEAR AFT SERVICE DOOR. REPLACED RT PANEL SUPPORT IAW SRM 51-41-01 & 51-43-01.SDR C77A20120603010Floorbeam · corrodedLEFT PANEL SUPPORT ON CROSSBEAM AT FRAME 86 BROKEN NEAR AFT SERVICE DOOR. REPLACED LT PANEL SUPPORT IAW SRM 51-41-01 & 51-43-01.SDR AALA20120620018Floorbeam · corrodedCORROSION ON FLOORBEAM STATION 986.5 RIGHT AND LEFT BUTTLINE 46. REPLACED FLOORBEAM PER SRM 53-70-51-2R4.SDR ASOA201201758Floorbeam · corrodedCARGO FLOORBEAM AT FS 349 BETWEEN LBL 27 - LBL 42 IS CORRODED ON UNDERSIDE. REPAIRED IAW SRM 51-42-06, 51-42-21.SDR ASOA201201757Floorbeam · corrodedCARGO FLOORBEAM AT FS 589 BETWEEN RBL 27 - RBL 41 IS CORRODED. BLENDED DAMAGE AND FOUND TO BE OUT OF LIMITS IAW SRM 51-321-06 & SRM 53-00-00. PERFORMED UT INSPECTION OF BLEND AREA IAW MWC NDT INSPECTION PROCEDURE UT-3. REPAIRED IAW REO 601R-53-61-4557.SDR ASOA201201756Floorbeam · corrodedCARGO FLOORBEAM AT FS 574 BETWEEN LBL 9.0 - RBL 9.0 IS CORRODED. REMOVED CORROSION IAW SRM 51-21-06. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-00. REMOVED AND INSTALLED CAP STRIP IAW SRM 51-42-06 AND 51-45-00, 51-42-15 AND DWG NR 601R35031.SDR ASOA201201754Floorbeam · corrodedCARGO FLOORBEAM AT FS 621 BETWEEN LBL 9 - 27 CORRODED. REMOVED CORROSION IAW SRM 51-21-06. BEYOND LIMITS IAW SRM 53-61-49.SDR ASOA201201737Floorbeam · crackedCABIN FLOORBEAM AT FS 280.00, RBL 9.0 IS CRACKED. REPAIRED IAW REO 601R-53-11-171.SDR ASOA201201720Floorbeam · corrodedFS 280.00 CROSSBEAM HAS CORROSION. REPLACED 280 CROSSBEAM IAW EC/TC REO 670-53-11-047.SDR CALA2012060400392Floorbeam · damagedFWD PIT STA 420 LT UNDER CABLE PULLEY FLOORBEAM HAS DAMAGE. REPAIRED IAW SRM 53-00-51, REPAIR 1.SDR V0XR20120604J0041Floorbeam · corrodedFS 280 FLOORBEAM CORRODED (BUBBLING PAINT), R & R FS 280 FLOORBEAM IAW SRM 51-42-06, 53-11-41.SDR V0XR20120604J0040Floorbeam · corrodedFS 280 FLOORBEAM CORRODED BEYOND SERVICEABLE LIMITS. R & R FS 280 FLOORBEAM IAW REO 670-53-11-047. TREATED AND PRIMED REPAIR AREA IAW SRM 51-25-06.SDR V0XR20120508J0041Floorbeam · corrodedFS 280 FLOORBEAM CORRODED (BUBBLING PAINT), R & R FS 280 FLOORBEAM IAW SRM 51-42-06, 53-11-41.SDR V0XR201205080040Floorbeam · corrodedFS 280 FLOORBEAM CORRODED BEYOND SERVICEABLE LIMITS. R & R FLOORBEAM IAW REO 670-53-11-047. TREATED AND PRIMED REPAIR AREA IAW SRM 51-25-06.SDR C77A20120601004Floorbeam · corrodedLEFT FLOORBEAM CORRODED BETWEEN FRAMES 17 AND 19A. REMOVED CORROSION BY BLENDING AND TREATING IAW SRM 51-10-03 & 51-12-01.SDR FDEA201206012051Floorbeam · corrodedBS 1340, FLOORBEAM UPPER SURFACE HAS CORROSION AT FASTENER HOLES BL 0 TO LBL 25. REMOVED DAMAGED FLOORBEAM FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51. INSTALLED NEW FLOORBEAM IAW SRM 53-60-51, SRM 51-40-02 AND DWG 146N5008. MAJOR REPAIR.SDR CALA2012060100386Floorbeam · corrodedFLOORBEAM BS 328 HAS CORROSION BL 0 TO RBL 23. REPAIRED FLOORBEAM IAW ECRA 5311-01554SDR REXA2012061800859Floorbeam · crackedRBL12 FLOORBEAM FS 272 CRACKED AT BACK-UP FITTING ATTACHMENT BOSS. REPAIRED IAW REO 690-53-11-383.SDR REXA2012061800858Floorbeam · crackedLBL12 FLOORBEAM FS 272 CRACKED AT BACK-UP FITTING ATTACHMENT BOSS. REPAIRED IAW REO 690-53-11-382.SDR REXA2012061300853Floorbeam · corrodedFS 280 CROSSBEAM SPLICE CORRODED. REMOVED AND REPLACED IAW SRM 53-00-00.SDR DALA1235230690Floorbeam · corrodedCORROSION ON MAIN CABIN FLOORBEAM UPPER CHORD AT TOP AND BOTTOM SURFACE AROUND FASTENER HOLES STA 377 BL 2L - BL 20L / OUT OF LIMITS. REPAIRED PER SRM 53-00-51 REPAIR 3.SDR DALA1235220690Floorbeam · corrodedMAIN CABIN FLOORBEAM HAS CORROSION AT BOTTOM EDGE OF UPPER CHORD STA 324 BL 9L, OUT OF LIMITS. REPAIRED PER ERA 503026-14.SDR SWAA2012062605331Floorbeam · corrodedFLOORBEAM CORRODED AT BS 986 UPPER FLANGE LOWER SIDE FLOORBOARD ATTACH HOLES. REPAIRED BEAM PER EA.SDR FDEA201205302016Floorbeam · misinstalledTHE STA 1640, FLOORBEAM IS MISLOCATED. REMOVED MISDRILLED FLOORBEAM IAW SRM 51-40-02. INSTALLED REPLACEMENT FLOORBEAM IAW DWG 146N8711 SH2 REV R. MAJOR REPAIRSDR AALA20120530009Floorbeam · corrodedFLOORBEAM AT STATION 1640 HAS CORROSION ON TOP OF LEFT BUTTLINE TO RIGHT BUTTLINE 4. INSTALLED T CAP, ANGLE AND STRAPS PER SRM 53-00-51-2R 3.SDR DALA12000626305Floorbeam · crackedDURING INSPECTION, FOUND MAIN DECK CABIN FLOORBEAM WEB CRACK AT BS 1200 AND RBL 109. MAINTANENCE REMOVED AND REPLACED MAIN DECK CABIN FLOORBEAM WEB PER WORKCARD 5313-01014-02G.SDR DALA12000616305Floorbeam · crackedDURING INSPECTION, FOUND MAIN DECK CABIN FLOORBEAM WEB CRACK AT BS 1180 AND RBL 109. MAINTANENCE REMOVED AND REPLACED MAIN DECK CABIN FLOORBEAM WEB PER WORKCARD 5313-01014-02F.SDR DALA12000606305Floorbeam · crackedDURING INSPECTION, FOUND MAIN DECK CABIN FLOORBEAM WEB CRACKED AT BS 1180 AND LBL 109. MAINTENANCE REMOVED AND REPLACED MAIN DECK CABIN FLOORBEAM WEB PER WORKCARD 5313-01014-02B.SDR USAA2012061100008Floorbeam · corrodedQ4 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM T-CAP AT BS 328, BETWEEN LBL 30 TO RBL 64. REPAIRED FLOORBEAM T-CAP AT BS 328, BETWEEN LBL 30 TO RBL 64 IAW B737-400 SRM 53-10-51-2R.SDR SWAA2012060504674Floorbeam · crackedFLOORBEAM UPPER CHORD CRACKED AT BS 294.3, RBL 55. REPAIRED CHORD IAW SRM.SDR AALA20120528011Floorbeam · corrodedRIGHT BUTTLINE 10 LONGITUDINAL FLOORBEAM BETWEEN STATIONS 955 AND 977 IS CORRODED. REMOVE AND REPLACE A SECTION OF THE LONGITUDINAL FLOORBEAM BETWEEN STATIONS 955 TO 977 PER SRM 53-00-51-2R.SDR DALA1240540918Floorbeam · corrodedAFTER REMOVAL OF FLOORBEAM STRUCTURE AT AFT CARGO BS 1322 BETWEEN L23L-L23R. FOUND CORROSION ON TEE AT BS 1322. CORROSION ON TEE WAS OUT OF LIMITS. REPLACED TEE PER SRM 51-30-02.SDR UALA2012052702968Floorbeam · corrodedMAIN CABIN BS 324 FLOORBEAM UPPER CHORD HAS CORROSION FROM RBL 46 TO RBL 55. MAJOR REPAIR ACCOMPLISHED: PERFORMED REPAIR TO MAIN CABIN STA 324 FLOORBEAM PER ECRA 5310-05518 AND EA PT57-53- 006.SDR AALA20120622003Floorbeam · corrodedFLOORBEAM NEXT TO FLOORBOARD MOUNT HOLE LOCATED AT STATION 328 RIGHT BUTTLINE 48 CORRODED. INSTALLED T-CHORD REPAIR ON RIGHT SIDE OF 328 FLOORBEAM PER SRM 53-10-51-2R7.SDR DALA1238050679Floorbeam · corrodedDURING HMV, FOUND LIGHT CORROSION ON MAIN CABIN FLOORBEAM AROUND FASTENER HOLES, STA 1640, RBL4 TO LBL 20. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS. REMOVED UPPER TEE OF FLOORBEAM, FABRICATED AND INSTALLED TEE REPAIR ANGLES AND STRAPS IAW B757 ERA 48913-SDR AALA20120618007Floorbeam · corrodedFLOORBEAM AT STATION 986.5 CORRODED IN NUMEROUS SPOTS FROM RIGHT AND LEFT BUTTLINE 46. INSTALLED T-CAP REPAIR PER SRM 53-70-51-2R 4.SDR SWAA2012061504954Floorbeam · corrodedFLOORBEAM CORRODED AT BS 344, LBL 9. REPAIRED BEAM IAW SRM.SDR UALA2012052702954Floorbeam · corrodedMAIN CABIN STA 1661 FLOORBEAM LBL14 - LBL15 HAS CORROSION. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGED AREA, FABRICATED TOP STRAP, FILLER, 2 ANGLES PER SRM 53-00-51. INSTALLED IAW SRM 53-00-01, PG 201, REPAIR 5, FIG 201.SDR UALA2012052702951Floorbeam · corrodedAFT GALLEY FLOORBEAM AT BS 1640 CORRODED AT FASTENER HOLES BETWEEN BL 0 AND RBL 55. SUPPLEMENTAL DATA UPDATE ALL WORKS PERFORMED ON FLOORBEAM AT STA.1640, BL0 - RBL 55 ACCOMPLISHED IAW PEMCO EA PT57-53-008 AND EC-RA 5360-01201.
Back to JASC 5315