JASC 5315
Service difficulty reports · 44,220
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA120408Attach Fitting · crackedDURING SCHEDULED 16Y CHECK, FOUND LONGITUDINAL FLOORBEAM ATTACH CLIP CRACKED AT BS 639, RBL 45.5. REMOVED AND REPLACED CLIP IAW SRM AND DWG.SDR COEA2012011813801Floorbeam · corrodedHEAVY CK COE / LEVEL 2 CORROSION: FLOORBEAM 36 HAS CORROSION ON UNDER SIDE OF THE TOP FLANGE AT RIGHT O/B SEAT TRACK. REMOVED FLOORBEAM, FABRICATED AND INSTALLED NEW FLOORBEAM REPAIR PIECE. FLOORBEAM SPLICE WAS PRE-EXISTING AND DONE.SDR COEA2012011808819Floorbeam · crackedHEAVY CK COE / MAJOR REPAIR: LONGITUDINAL FLOORBEAM CRACKED LEFT O/B AFT FR 30. REMOVED CRACKED SECTON, FABRICATED AND INSTALLED NEW SECTION LEFT O/B LONGITUDINAL FLOORBEAM FROM FRAME 30-31, WL 2327.5, BL 640L IAW M7 DWG & M7 SB ATR72-53-015.SDR AALA20120118TUL05Floorbeam · corrodedCORROSION FOUND ON TOP OF FLOORBEAM STATION 328 AT RIGHT BUTTLINES 7 THRU 54. COMPLETED FLOORBEAM REPAIR PER SRM 53-10-51-2R 7 AND EA B737-53-021045.SDR AALA20120118TUL02Floorbeam · corrodedT-CHORD FROM STATION 947 FLOORBEAM FROM LEFT BUTTLINE 58 TO RIGHT BUTTLINE 58 HAS CORROSION. INSTALLED NEW FLOOR BEAM T-CHORD AND REPAIR SPLICE ON 947 FLOORBEAM PER SRM 53-70-51-2R 5 AND EA B737-53-021083.SDR IPXA2B71256Floorbeam · corrodedINSPECTION TYPE:C, BULK CARGO BAY STA 2044, LBL 54 TO RBL 54 FLOORBEAM UPPER & LOWER SURFACE FOUND SEVERAL AREAS CORRODED. REPLACED IAW SRM 51-10-02 AND INSTALLED IAW SRM 51-40-02, REV.19. THICKNESS IS 0.050",BLEND DEPTH IS 0.037", WIDTH 1" & LENGTH 1.5" OUSDR ASOA201200183Floorbeam · corrodedFS 349 FLOORBEAM IS CORRODED ON OTBD END. REPAIRED IAW REO 601R-53-21-2250.SDR ASOA201200178Floorbeam · corrodedFS 280.00 FLOORBEAM TEE CORRODED, REPAIRED IAW REO 670-53-11-047 AND REO 670-53-11-047, REV E.SDR UALA2012011900391Floorbeam · corrodedPASSENGER CABIN MAIN DECK FLOORBEAM STA 377 RBL 48-63 IS CORRODED UPPER CAP. ACCOMPLISHED REPAIR DURING HMV 4 PER ECRA 5310-05432. WORK ACCOMPLISHED ON SCAL LOG 99556 62.SDR UALA2012011800372Floorbeam · corrodedBS 287 FLOORBEAM RT UPPER T-CAP REPAIR HAS CORROSION. MAJOR REPAIR ACCOMPLISHED. RMV'D EXISTING REPAIR, FABBED AND INSTALLED T-CUP, 2 EA ANGLES, AND 1 EA STRAP PER SRM 51-40-02 ON PEMCO NR 3811N00414.SDR UALA2012011800371Floorbeam · corrodedPASSENGER CABIN MAIN DECK FLOORBEAM STA 377 RBL 48-63 IS CORRODED UPPER CAP. MAJOR REPAIR ACCOMPLISHED. REPAIRED DURING HMV 4 PER ECRA 5310-05432. WORK ACCMP'D ON SCAL LOG 99556 62.SDR SWAA120398Attach Fitting · crackedDURING SCHEDULED SPV CHECK, FOUND LONGITUDINAL FLOORBEAM ATTACH CLIP CRACKED AT BS 639, LBL 45.5. REMOVED AND REPLACED CLIP IAW SRM AND DWG.SDR AALA20120117TUL06Floorbeam · corrodedENTIRE FLOORBEAM UPPER CAP AT STATION 986 CORRODED. INSTALLED T-CAP REPAIR PER SRM 53-70-51.SDR SWAA120383Floorbeam · corrodedDURING SCHEDULED 16Y CHECK, FOUND FLOORBEAM UPPER CHORD CORRODED AT BS 947, LBL 20. REPAIRED CHORD PER SRM.SDR FDEA201201170214Floorbeam · corrodedCORROSION ON FLOORBEAM UPPER CAP LOWER SURFACE AT STA 324, RBL 58. CORROSION REPAIR CARRIED OUT IAW EA F-5300-154492, PART 1. REPAIR IS CLASSIFIED AS MAJOR.SDR SWIA201229389Floorbeam · corrodedFS 280 FLOORBEAM HAS CORROSION ON RIGHT AND LEFT SIDES AROUND NUT PLATES. (C-CHECK) REPAIR FS 280 FLOORBEAM CORROSION ON RIGHT AND LEFT SIDES AROUND NUT PLATES.SDR DALA1202271707Floorbeam · corrodedCABIN STA 654+110 RBL 21, FLOORBEAM UPPER CHORD CORROSION. THE FLOORBEAM REPAIR AS PER B767-300 SRM 53-00-51 FIG 201 REPAIR 1.SDR SWAA120366Floorbeam · corrodedDURING SCHEDULED 24Y CHECK, FOUND FLOORBEAM CORRODED AT BS 328, RBL 47. REPAIRED BEAM IAW SRM.SDR SWAA1201124Support · crackedBS 639, RBL 45.5 FLOORBEAM SUPPORT WEB FOUND AT STUB BEAM ATTACH CLIP LOWER FASTENER HOLE CRACKED. REPAIRED WEB PER SEA EA.SDR SWIA201229409Floorbeam · crackedFS 280 FLOORBEAM IS CRACKED AND CORRODED. (C-CHECK) REPAIR CRACK AND CORROSION AT FS 280 OF FLOORBEAM.SDR SWAA120299Fitting · crackedDURING SCHEDULED 16Y CHECK, FOUND LONGITUDINAL FLOORBEAM CLIP CRACKED AT BS 639, LBL 45.5. REMOVED AND REPLACED CLIP IAW SRM AND DWG.SDR SWAA120294Floorbeam · crackedDURING SCHEDULED 20Y CHECK, FOUND LONGITUDINAL FLOORBEAM UPPER CHORD CRACKED AT BS 727B, RBL 45.5. REPAIRED CHORD IAW EA.SDR SWAA120293Floorbeam · corrodedDURING SCHEDULED 20Y CHECK, FOUND FLOORBEAM UPPER CHORD T-ANGLE CORRODED AT BS 986.5, RBL 44. REPAIRED CHORD IAW EO.SDR SWIA201231467Floorbeam · dentedFLOORBEAM 349.00 DENTED ON AFT SIDE JUST OUTBOARD OF RBL 9. (C-CHECK) REPAIRED IN REFERENCE TO CRJ700 SRM.SDR A6WA201240319Floorbeam · crackedFS 484 FLOORBEAM ANGLE CRACKED AT RBL 27-78. REPAIRED CRACKED FLOORBEAM ANGLE AT FS 484, RBL 27 IAW REO 601R-53-41-059, REV B.SDR USAA2012012700004Floorbeam · corrodedC2 CHECK - LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM AT FR13, Z-490, -Y273. REPLACED FLOORBEAM AT FR13, Z-490, -Y273 IAW TYPICAL REPAIR # TR190-5300-0563, ER-J190 SRM 51-23, 51-40, 51-41 & 51-43.SDR USAA2012012400009Floorbeam · corrodedC2 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR87, Z-490, Y273. REPLACED FLOORBEAM AT FR87, Z-490, Y273 IAW TYPICAL REPAIR TR190-5300-11-0563.SDR USAA2012012400008Floorbeam · corrodedC2 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR17, Z-490, Y273. REPLACED FLOORBEAM AT FR17, Z-490, Y273 IAW TYPICAL REPAIR TR190-5300-11-0563.SDR USAA2012012400007Floorbeam · corrodedC2 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR17, Z-490, -Y273. REPLACED FLOORBEAM AT FR17, Z-490, -Y273 IAW TYPICAL REPAIR TR190-5300-11-0563.SDR ASOA201200143Floorbeam · crackedANGLE CRACKED AT RBL 9 FLOORBEAM AT FS280. REMOVED CRACKED ANGLE IAW SRM 51-42-20. LOCATED AND DRILLED NEW ANGLE. INSTALLED ANGLE IAW SRM 51-42-20.SDR ASOA201200142Floorbeam · crackedANGLE CRACKED AT LBL 9 FLOORBEAM AT FS 280. REMOVED CRACKED ANGLE IAW SRM 51-42-20. LOCATED AND DRILLED NEW ANGLE. INSTALLED ANGLE IAW SRM 51-42-20.SDR JR2R2012011300035Floorbeam · corrodedDRILL START WITH STUCK SCREW ON FLOORBEAM AT RBL 9 AND FS 847. REPAIRED IAW RO CRJ9-53-0937.SDR JR2R2012011300034Floorbeam · corrodedFLOORBEAM CORRODED AROUND SCREW HOLE AT FS 830. REPAIRED IAW RO CRJ9-53-0933.SDR ZZDA20120112081Floorbeam · corrodedFLOORBEAM, BS 540, RBL 2 TO LBL 2, CORRODED. ACCOMPLISHED FLOORBEAM REPLACEMENT PER SRM 51-40-02.SDR ASOA201200148Floorbeam · corrodedRT SIDE FS 349 FLOORBEAM IS CORRODED ON OTBD END. REMOVED CORROSION IAW SRM 51-21-06, STEP 3. FOUND TO BE OUT OF LIMITS. REMOVED DAMAGE IAW REO 601R-53-21-2250, STEPS 1 AND 2. PERFORMED EDDY CURRENT IAW NDTM 51-20-06. NO INDICATIONS NOTED.SDR SWAA120264Floorbeam · corrodedDURING SCHEDULED 12Y CHECK, FOUND FLOORBEAM CORRODED AT BS 344, BL 11. REPAIRED BEAM IAW SRM.SDR SWAA120260Floorbeam · crackedDURING SCHEDULED 16Y CHECK, FOUND LONGITUDINAL FLOORBEAM WEB CRRACKED AT BS 640, RBL 45.5. REPAIRED WEB IAW SRM AND EA.SDR DALA1201536303Floorbeam · corrodedMAIN DECK FLOORBEAM UPPER SURFACE OF UPPER TEE CORRODED BS 880 RBL 22-34. S=2"X1. REPAIRED FLOORBEAM PER SRM 53-20-51 REPAIR 5 FIG 201.SDR DALA1205436303Floorbeam · corrodedMAIN DECK FLOORBEAM UPPER CHORD UPPER SURFACE CORROSION BS 980. RBL 53.5. S=1.5"X2" SCEPTRE LOG PAGE ENTERED AND DEFERRED FOR SDR REPORTING. REPAIRED THE CORRODED FLOORBEAM UPPER CHORD PER B747-400 SRM 53-20-51.SDR DALA1201716303Floorbeam · corrodedFOUND SURFACE CORROSION ON MAIN DECK FLOORBEAM UPPER CHORD 39/240 BS 980 RBL 53.5, S=1.5" X 2" LOG WRITTEN AND DEFERRED FOR SDR REPORTING.SDR REXA201200012Floorbeam · corrodedFLOORBEAM CAP FROM FS 589-FS 621 AT LBL 27 FOUND CORRODED AROUND NUT PLATES. REPAIRED IAW BOMBARDIER REO 601R-53-00-005.SDR SWAA120216Floorbeam · crackedDURING SCHEDULED 16Y CHECK, FOUND LONGITUDINAL FLOORBEAM UPPER CHORD CRACKED BETWEEN BS 666 TO BS 670, LBL 25. REPAIRED CHORD PER ER AND EA.SDR COEA2012011107819Floorbeam · bentHEAVY CK / MAJOR REPAIR: LEFT O/B LONGITUDINAL FLOORBEAM IS BENT JUST FWD OF FRAME 23C. REMOVED DAMAGED SECTION / FABRICATED AND INSTALLED NEW FLOORBEAM AND CLIPS IAW M7 SB ATR72-53-015.SDR COEA2012011106819Floorbeam · bentHEAVY CK / MAJOR REPAIR: RIGHT O/B LONGITUDINAL FLOORBEAM IS BENT JUST AFT OF FRAME 23C. REMOVED DAMAGED SECTION / FABRICATED AND INSTALLED NEW FLOORBEAM AND CLIPS IAW M7 SB ATAR72-53-015.SDR COEA2012011105819Floorbeam · crackedHEAVY CK / MAJOR REPAIR: LEFT O/B LONGITUDINAL FLOORBEAM IS CRACKED JUST FWD OF FRAME 25. REMOVED DAMAGED SECTION / FABRICATED AND INSTALLED NEW FLOORBEAM AND CLIPS IAW M7 SB ATR72-53-015.SDR COEA2012011104819Floorbeam · crackedHEAVY CK / MAJOR REPAIR: LT OUTBOARD LONGITUDINAL FLOORBEAM IS CRACKED JUST FWD OF FRAME 26. REMOVED DAMAGED SECTION / FABRICATED AND INSTALLED NEW FLOORBEAM AND CLIPS IAW M7 SB ATR72-53-015.SDR COEA2012011103819Floorbeam · crackedHEAVY CK / MAJOR REPAIR: RIGHT O/B LONGITUDINAL FLOORBEAM IS CRACKED JUST AFT OF FRAME 28C. REMOVED DAMAGED SECTION / FABRICATED AND INSTALLED NEW FLOORBEAM AND CLIPS IAW M7 SB ATR72-53-015.SDR A6WA201240180Floorbeam · crackedFLOOR STRUCTURE FS 280 IS CRACKED JUST OTBD OF LBL 9. C/W REO`S 601R-53-11-171, REV D AND 601R-53-11-2265 C/W NDT, NO DEFECTS NOTED.SDR DALA1201526303Floorbeam · corrodedCORROSION FOUND ON FLOORBEAM BS 1700. RBL 46. S: 1"X1". REPAIRED PER ERA 496578-14 REV 0.SDR DALA1205140668Floorbeam · corrodedMAIN CABIN FLOORBEAM CORRODED ON UPPER SURFACE STA 1640 LBL 59-RBL 59. CORROSION ON EXISTING REPAIR FROM LBL 13- RBL 9 OUT OF LIMITS. REMOVED EXISTING REPAIR AND FLOORBEAM TO LBL 35 FABRICATED AND INSTALLED FLOORBEAM AND REPAIR ANGLES IAW B757 SRM 53-00-51 D
Back to JASC 5315