JASC 5315
Service difficulty reports · 44,223
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 06FDEA0632Floorbeam · corrodedFOUND BS 480 RBL 65 TO LBL 65 FLOORBEAM IS CORRODED AT NUT PLATE HOLES. REPAIRED FLOORBEAM AT BS 480 LBL 65 TO RBL 65 IAW SRM 53-10-8.SDR 06FDEA0606Floorbeam · corrodedAFT CARGO BAY, CORROSION ON BS 1130 FLOORBEAM LWR CHORD AT NUT PLATE HOLES RBL 65 - LBL 65, WL 200. REPAIRED DAMAGED AFT CARGO BAY FLOORBEAM, BS 1130, LOWER CHORD, RBL 45 TO LBL 45, WL 200 PER FED-EX EA 7-5310-99474SDR 06FDEA0600Floorbeam · corrodedFOUND BS 1070 FLOORBEAM IS CORRODED AT NUT PLATE HOLES LBL 65 - RBL 65, WL 201. REPAIRED OUT OF LIMITS AREA AT STA 1070 W/L 201 RBL 48 IAW SRM 53-10-8, ALL OTHER AREAS FOUND TO BE IN LIMITS IAW SRM 53-10-1.SDR ASAA0640142Floorbeam · corrodedFOUND CORROSION ON FLOORBEAM AT PREVIOUS REPAIR. REPAIRED FLOORBEAM PER EA 5310 02564.SDR ASAA0640141Floorbeam · corrodedFOUND CORROSION ON BOTTOM OF 986.5 FLOORBEAM UPPER FLANGE. REPAIRED PER EA 5310 02565.SDR 06FDEA0580Floorbeam · corrodedFLOORBEAM IS CORRODED ON LWR FLANGE AT NUT PLATE HOLE BS 640 RBL 48. REPAIRED PER SRM 53-10-8 MAJOR REPAIR.SDR UPS06146190Floorbeam · crackedINSPECTION TYPE:5YR, AVIONICS COMPARTMENT FLOOR PANEL NR 121TF BETWEEN AVIONICS RACKS HAS CRACKED FLOORBRACE. REMOVED AND REPLACED FLOORBRACE PER A300 SRM 51-40-21.SDR 2006UALA00240Floorbeam · crackedFLOORBEAM STA 639 LBL 47, BRACKET OUTBOARD & AFT BELOW SEAT TRACK CRACKED. REMOVED CRACKED ANGLE & REPLACED WITH NEW FABRICATED ANGLE REF SRM 51-4-02 BOEING DRAWING 65-46540 GNMM 1-0-0-023.SDR CALA0600316Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED ON FORWARD SIDE AT STA 1016, LBL 35.5. THE FLOORBEAM WAS REPAIRED IAW SRM 53-00-51, FIGURE 201, REPAIR 3.SDR SWIA200616472Floorbeam · crackedFOUND CARGO COMPARTMENT FS 621 LT FLOOR SUPPORT ANGLE LBL 41 CRACKED. REPAIRED ANGLE IAW CRJ REO 601R-53-61-117 REV C.SDR SWAA060454Floorbeam · crackedDURING SCHEDULED D-CHECK, FOUND FUSELAGE FLOORBEAM CRACKED AT BS 947, LBL 53, WL 208. REPAIRED FLOORBEAM PER BFG ER.SDR SIMA200604104Floorbeam · corrodedDURING IMBV INSPECTION FOUND FWD CABIN DIGITAL HAS SMALL AREA OF CORROSION. REPAIRED DIGITAL IAW SRM BY SPLICING IN A NEW PIECE. AIRCRAFT WAS RETURNED TO SERVICE. (K)SDR 2006UALA00205Floorbeam · gougedPASSENGER CABIN, STA 927 FLOORBEAM UPPER SURFACE AT LBL 25.5 AND LBL 44.5 IS GOUGED. *S/D* REMOVED DAMAGE REF SRM 53-60-51. INSTALLED REPAIR REF SRM 53-60-51. INSTALLED NEW SEAT TRACK FLOOR SUPPORT, INSTALLED INTERCOSTAL AND ATTACH ANGLES.SDR SWAA060414Floorbeam · corrodedDURING SCHEDULED 1/4D CHECK, FOUND LONGITUDINAL FLOORBEAM CORRODED AT BS 729B, RBL 3. REPAIRED FLOORBEAM PER SWA EA.SDR SWAA060413Floorbeam · corrodedDURING SCHEDULED 1/4D CHECK, FOUND LONGITUDINAL FLOORBEAM CORRODED AT BS 732A, RBL 3. REPAIRED FLOORBEAM PER SWA EA.SDR UPS06M46531Floorbeam · corrodedAFT CARGO COMPT AT STA1841 X=-14 TO -28 FOUND LOWER FLOORBEAM UPPER CAP CORROSION AROUND THE FASTENER HOLES 2 PLCS AS MARKED. AFT CARGO COMPT STA1841 X=-14 TO -28 FLOORBEAM UPPER CAP CORROSION REMOVED AND FOUND OUT OF LIMIT SRM 51-21-01 VOLII. REMOVED FLOORBSDR AWXA200600451Floorbeam · corrodedDURING C11 CHECK DISCOVERED LEVEL 2 CORROSION ON FLOOR BEAM AT BS 1661, WL 208.10 AND BL 21R. CORROSION WAS FOUND TO BE OUT OF LIMITS IAW BOEING 757200 SRM 757-200 53-00-51-1A-1. MAINTENANCE CUT OUT DAMAGED AREA IAW BOEING 757-200 SRM 53-00-51-2R5 PAGE 1 DETSDR AWXA200600450Floorbeam · corrodedSAL - DURING C11 CHECK DISCOVERED LEVEL 2 CORROSION LOCATED ON SUPPORT AT BS 1683.8, WL 208.10 AND FROM BL 6L TO BL 6R. NO ALLOWABLE LIMITS WERE FOUND IN THE SRM. MAINTENANCE REMOVED AND INSTALLED FABRICATED SUPPORT AT BS 1683.8, WL 208.10 AND FROM BL 6L TO SDR DHL2006804525Floorbeam · maint errorMAIN CARGO COMPT FLOORBEAM HOLE MISDRILLED STA 742.250 RBL 32.5 (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW FAA FORM 8110-3 DATED 01-31-06, DWG AA66-53-R01 REV IR DATED 01-16-06. CUT OUT DAMAGED SECTION AND FABRICATED REPAIR ANGLE AND FILLER (EXTRUSION 7075T6SDR USAA060221Floorbeam · corrodedLOCATION: BEAM Y512 @ STA 66 ACTION: REMOVED & REPLACED PER SRM 51-72-11; CORR. LEVEL 1; TASK JA-260-53500 DEFECT SIZE: 3" X 76"SDR 06FDEA0516Floorbeam · misdrilledWHILE WORKING CUST CARD N01118 DISCOVERED DBL DRILLED HOLES IN FLOORBEAM UPPER CHORD AT BS 740 LBL 45 WL 208. FLOOR BEAM UPPER CHORD AT BS 740 LBL 45 WL 208 REPAIRED IAW SRM 53-10-4SDR USAA060216Floorbeam · corrodedAT FLOOR SUPPORT Y354 AND C16 CORRODED. INSTALLED REPAIR & DOUBLER PER SRM 53-00-14; CORROSION LEVEL 1; TASK JA-220-53500, DEFECT SIZE: 4' X 8".SDR USAA060218Floorbeam · corrodedAT -Y81 FRAME 12-16 CORROSION. REPLACED BEAM WITH SAME P/N PER SRM 51-72-11; CORROSION LEVEL 1; TASK JA-220-53500, DEFECT SIZE: 1 X 2 X .040 INCH DEEP.SDR USAA060219Floorbeam · corrodedFLOORBEAM -Y1292, RIGHT STA 64-68 CORRODED. REMOVED & REPLACED WITH IDENT PART PER SRM 51-72-11; CORROSION LEVEL 1; TASK JA-260-53500, DEFECT SIZE: 3" X 9'.SDR USAA060220Floorbeam · corrodedFLOORBEAM Y1292 LEFT STA 66-68 CORRODED. REMOVED & REPLACED WITH IDENTICAL PART PER SRM 51-72-11; CORROSION LEVEL 1; TASK JA-260-53500, DEFECT SIZE: 3" X 9'.SDR SIMA200604604Floorbeam · corrodedDURING HMBV INSPECTION FOUND TOP OF CENTER FLOORBEAM AT FRAME 19A CORRODED. REPAIRED FLOORBEAM WITH DOUBLER IAW SRM. AC RETURNED TO SERVICE. (K)SDR C2XA06SH016Floorbeam · corrodedSHV - DURING C-CHECK THE CENTER OMEGA BEAM WAS FOUND TO BE CORRODED AFT OF FRAME 23. MAINTENANCE REMOVED AND REPLACED THE AFFECTED BEM IAW EMB 135 SRM 51-40-02. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR 06FDEA0497Floorbeam · corrodedCORROSION ON FLOORBEAM STA 440, RBL 10, WL 208. REPAIRED FLOORBEAM IAW SRM 53-10-1, 53-10-4, 51-30-02.SDR SWAA060404Floorbeam · crackedDURING SCHEDULED D-CHECK, FOUND FUSELAGE FLOORBEAM CRACKED AT BS 947.5, LBL 53, WL 208. REPAIRED FLOORBEAM PER BFG ER.SDR 06FDEA0507Floorbeam · tool damageTOOLING DAMAGE ON FLOORBEAM BS 720F BBL0 WL 207. REPAIRED FLOOR BEAM AT 720F BL 0 WL 207 PER FED EX EA 7-5310-99423.SDR USAA060193Floorbeam · corrodedOVER LIMITS, Y790 AT FR 74 CORRODED. REPLACED FLOORBEAM PER SRM 53-41-14, 51-72-11; CORROSION LEVEL 1; TASK C534159-01, DEFECT SIZE: 1 X 4 INCH.SDR USAA060178Floorbeam · corrodedFRAME 66 FLOOR SUPPORT Y-1292. INSTALLED DOUBLER PER SRM 53-41-14, DEFECT SIZE: .75 INCH.SDR USAA060190Floorbeam · corrodedY790 AT FR 74 CORROSION. REPLACED FLOORBEAM PER SRM 53-41-14, 51-72-11; CORROSION LEVEL 1, TASK C534159-01, DEFECT SIZE: .055 INCH DEEP.SDR SWIA200616513Floorbeam · crackedCARGO COMP, FLOORBEAM IS CRACKED, FS 621.00, LBL 38.0. ITEM FOUND AT C-CHECK INSPECTION. FLOORBEAM FS 621.00 LBL 38.0 IAW CRJ REO 601R-53-61-117 REV C.SDR AMTA200600101Floorbeam · corrodedAFT CABIN FLOOR STRUCTURE FLOORBEAM UPPER FLANGE FOUND WITH CORROSION AT FS 1763 LBL 39-55. FLOORBEAM WAS BLENDED AND FOUND BEYOND LIMITS PER SRM 53-21-00. CUTOUT DAMAGED FLOOR T-CAP AND REPAIRED IAW SRM 53-21-00 FIG 815 AND SRM 51-40-01. (M)SDR 2006UALA00173Floorbeam · corrodedAFT PIT FLOORBEAM AT STA 771 LBL 2, STR 27L IS CORRODED. BLENDED CORRODED AREA, MATERIAL LOSS OUT OF LIMITS REF SRM 53-60-53. REMOVED DAMAGED AREA, FABRICATED REPAIR STRAP, BACK DRILLED FASTENER HOLES REF 53-42-97. PAINTED REPAIR, INSTALLED REPAIR STRAP WITSDR 06FDEA0451Floorbeam · corrodedWHILE PREPPING TO CLOSE FLOORBOARDS FOUND CORROSION ON UPPER FLOORBEAM AT BS 1110 BL 0 - RBL 25. *S/D* REPAIRED UPPER FLOORBEAM AT BS 1110 BL 0 - RBL 25.SDR SWAA060371Floorbeam · corrodedDURING SCHEDULED D CHECK, FOUND COCKPIT FLOOR Z-CHORD CORRODED AT BS 270, BETWEEN LBL 11 TO RBL 11, WL 208. REMOVED AND REPLACED Z-CHORD PER SRM.SDR USAA060169Floorbeam · corrodedFOUND CORROSION FLOOR SUPPORT BEAM Y254 NEAR FRAME 16. DEFECTIVE PART REPLACED WITH IDENT PART PER SRM 51-72-11; CORROSION LEV 1; TASK JA-220-53500 DEFECT SIZE: 1/2" DIA (3 EA.)SDR USAA060168Floorbeam · corrodedFOUND FLOORBEAM Y1292 FRAME C65-C69. DEFECTIVE PART REPLACED WITH IDENT PART PER SRM 53-41-14 AND DWG D53472092; TASK JA-260-53500, DEFECT SIZE: 1" BY 1-1/2" ON EACH SEGMENT OF BEAM.SDR USAA060167Floorbeam · corrodedFOUND FLOORBEAM CORRODED C66 AT Y1732. INSTALLED ANGLES AND FILLERS PER SRM 53-41-14 FIG. 201; CORROSION LEVEL 1; TASK JA-260-53500, DEFECT SIZE: 1/2" X 1-1/2".SDR C1HA200682009Floorbeam · corrodedFLOORBEAM BS 344 HAS CORROSION. REMOVED PREVIOUS REPAIR IAW B727 SRM 51-30-2, CUT OUT DAMAGED AREA, FABBED FILLER, 7075-T6, .080, 1 X .1875 INCH (2EA) REPAIR ANGLES 7075-T6, .071, 16.5 X 1.875 INCH, & 2 EA SAME MAT 14.5 X 1.875 INCH IAW B727 SRM 53-10-2 FIG 7SDR C1HA200682007Floorbeam · corrodedBS 1030 RBL 4 - 10 LBL CABIN FLOOR SUPPORT UPPER FLANGE HAS CORROSION. CUT OUT DAMAGE AREA AT BS 1030 RBL 20 TO LBL 10 IAW B727 SRM 51-10-1, FABRICATED T-SUPPORT USING BAC1505-100617, DIM 43.125 X 2.25 INCH, 2 EA SUPPORT ANGLE AND TWO STRAP IAW B727 SRM 53-10SDR C1HA200682008Floorbeam · corrodedBS 1110 LBL 24 - RBL 24 TRANSVERSE FLOOR SUPPORT UPPER FLANGE HAS CORROSION (BOTH SIDES). REMOVED EXISTING REPAIR IAW B727 SRM 51-30-2. REMOVED LBL 24 TRACK IAW B727 SRM 51-30-2, FABRICATED T-ANGLE 60 INCH DIM 4 ES STRAP DIM 15", 11", 14" AND 10.5". FOUR EASDR DL73S060090Floorbeam · crackedTHE LBL & RBL 24 LONGITUDINAL OVERWING FLOORBEAMS WERE PREVIOUSLY MODIFIED PER REV B OF 3-56673-12AD, HOWEVER THIS INSTALLATION DOES NOT MEET THE REQUIREMENTS OF AD 2001-17-18. FLOORBEAM WEBS WERE FOUND CRACKED. FLOORBEAM C-CHANNELS WERE REPLACED WITH AD COMSDR AWXA200600282Floorbeam · corrodedMCN - DURING C4 CHECK DISCOVERED CORROSION ON Y254 BEAM, AT FS 16 AND FS 20+4". CORROSION WAS FOUND TO BE OUT OF LIMITS IAW AIRBUS 320 SRM 53-11-14 FIG 104. MAINTENANCE REMOVED AND INSTALLED NEW FLOORBEAM AT Y254 FROM FS 12 TO FS 24 IAW AIRBUS 320 SRM 51-47-SDR AWXA200600276Floorbeam · corrodedMCN - DURING C4 CHECK DISCOVERED CORROSION ON THE Y-1350 FLOORBEAM PLATE AT FS 16. NO CORROSION REMOVAL LIMITS AVAILABLE IN THE AIRBUS SRM. MAINTENANCE REMOVED AND INSTALLED NEW FLOOR BEAM PLATE AT Y-1350 AND FR16 IAW AIRBUS 320 SRM 51-42-11 FIG 8.SDR ASAA0640062Floorbeam · corrodedPAE: CORROSION ON FLOORBEAM. BLENDED CORROSION, FABRICATED REPAIR STRAP AND INSTALLED IAW SRM. (K)SDR MALA060033Floorbeam · corrodedDURING THE 2 YEAR INSPECTION, CORROSION WAS FOUND ON THE RT FLOOR FRAME AT STATION 294.0 WL 70.5. THE REPAIR WILL BE CARRIED AS PER MESABA EO 3S53152 ON MM409 ##223576.SDR ASAA0640060Floorbeam · corrodedPAE - FOUND CORROSION ON FLOORBEAM AT BS 986.5, RBL 44 TO LBL 44, WL 208. REPAIRED PER ER 05-5163, AND EA 5310-02558. (M)
Back to JASC 5315