JASC 5315
Service difficulty reports · 44,223
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AWXA0001864Beam · corrodedd: upom removal of strap HFEC Indicates crack .7" WL 212 RBL 6.8 on BS178 Blkhd web fwd facec: repaired IAW B737-300 SrM 53-10-08 Pg 287-298SDR RRXA11286Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FLOORBEAM ATS STA.1700 AND RBL 24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DHSK606-343. (CORROSION DAMAGE RECORDED IN ESDR SWAA011733Floorbeam · corrodedDURING SCHEDULED D-CHECK, FOUND CORROSION ON FLOORBEAMS AFT CARGO AT BS 727D TO BS 847, WL 157, LBL 7.5 TO RBL 2.5. REPAIRED FLOORBEAMS PER SRM.SDR SWAA011732Floorbeam · corrodedDURING SCHEDULED D-CHECK, FOUND CORROSION ON FLOORBEAM AFT CARGO, BS 767, WL 157, RBL 7.5 TO LBL 17. REPAIRED FLOORBEAM PER SRM.SDR SWAA011730Floorbeam · corrodedDURING SCHEDULED D-CHECK, FOUND CORROSION ON FLOORBEAM E&E COMP, AT BS 312, WL 208, LBL 11 TO RBL 11. REPAIRED FLOORBEAM PER SRM.SDR USAA010860Floorbeam · corrodedPIT - FOUND BEAM CORRODED 1 INCH BY 4 INCHES, BS 967 UPPER T-CAP. CORROSION LEVEL 1. REPLACED PER 53-00-51. (M)SDR 2001UALA01023Floorbeam · corrodedCABIN FLOOR SUPPORT STRUCTURE CORRODED STA 324 - 344, RBL 60. MAJOR REPAIR ACCOMPLISHED. INSTALLED REPAIR STRAPS.SDR 2001UALA01022Floorbeam · corrodedCABIN FLOORBEAM UPPER FLANGES CORRODED STA 310.5, RBL 40. *S/D* RECONNECTED POWER CONNECTOR IN INSIDE OF SIDE WALL. OP CHECKS OK.SDR ZW0A0103705Floorbeam · gougedDURING CHECK-C MAINT A GOUGE WAS FOUND IN THE BOTTOM FLANGE OF THE CABIN FLOORBEAM, STA 408, RBL 2 INCH. BLENDED GOUGE IN BOTTOM FLANGE OF CABIN FLOORBEAM, STA 408, RBL 2 IN. FABRICATED REPAIR ANGLE AND REPAIR STRAP AND PHENOLIC RUB STRIP PER SSRM 53-60-103,SDR 2001F00124Floorbeam · corrodedSAW - DURING CPCP-4 INSPECTION, MAINTENANCE REPORTED FLOORBEAM 36, 38 AND 39 CORRODED. MAINTENANCE REMOVED AND REPLACED FLOORBEAMS 36 AND 38 IAW SRM 53-00-00. MAINTENANCE REPAIRED FLOORBEAM 39 IAW SRM 53-00-00 FIGURE 435. AIRCRAFT WAS RETURNED TO SERVICE. RSDR 2001F00123Floorbeam · corrodedSAW - DURING CPCP-4 INSPECTION, MAINTENANCE REPORTED FLOORBEAM 36, 38 AND 39 CORRODED. MAINTENANCE REMOVED AND REPLACED FLOORBEAMS 36 AND 38 IAW SRM 53-00-00. MAINTENANCE REPAIRED FLOORBEAM 39 IAW SRM 53-00-00 FIGURE 435. AIRCRAFT WAS RETURNED TO SERVICE. RSDR SIMA20011712Floorbeam · corrodedSAW - DURING CPCP-4 INSPECTION, MAINTENANCE REPORTED FLOORBEAM 36, 38 AND 39 CORRODED. MAINTENANCE REMOVED AND REPLACED FLOORBEAMS 36 AND 38 IAW SRM 53-00-00. MAINTENANCE REPAIRED FLOORBEAM 39 IAW SRM 53-00-00 FIGURE 435. AIRCRAFT WAS RETURNED TO SERVICE. (SDR USAA010650Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED .5 INCH, BS 967, RBL 5. REMOVED AND REPLACED ENTIRE T-CAP PER TR 53-10-05A. REMOVED AND REPLACED ENTIRE TEE CAP PER TR 53-10-05A. (M)SDR USAA010651Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 100 INCH BY 2 INCH AREA, BS 986, AFT ENTRY DOOR TO AFT GALLEY SERVICE DOOR. REMOVED AND REPLACED ENTIRE T-CAP PER TR 53-10-05A. (M)SDR USAA010652Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED APPROXIMATELY 3 SQUARE INCH AREA, BS 312, RBL 8. REMOVED AND REPLACED T-CAP SECTION PER SRM 53-10-51 AND 51-20-01. (M)SDR USAA010653Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED APPROXIMATELY 12 SQUARE INCH AREA, BS 328, BL 0 TO RBL 60. REMOVED AND REPLACED ENTIRE TEE CAP PER SRM 53-10-51. (M)SDR USAA010654Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED APPROXIMATELY 1 SQUARE INCH AREA, BS 344, LBL 24 TO RBL 11. REMOVED AND REPLACED T-CAP SECTION PER SRM 51-10-2 AND 53-10-51. (M)SDR USAA010657Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED APPROX 14 SQUARE INCHES, BS 1016 LBL 45 TO RBL 45. REMOVED AND REPLACED T-CAP PER SRM 53-00-51. (M)SDR 2001UALA01009Floorbeam · corrodedAFT CABIN FLOORBEAM LOWER SURFACE CORRODED STA 1681, RBL 4, RBL 30, LBL 12. MAJOR REPAIR ACCOMPLISHED. INSTALLED ANGLE AND STRAP REPAIR.SDR AT0100210Floor Panel · corrodedFOUND FORWARD PIT FLOOR PANEL AT BS 218-332 CORRODED BEYOND LIMITS. CORRECTIVE ACTION: FABRICATED AND INSTALLED REPAIR PANEL IAW DC9 SRM 51-10-02, 51-10-03, AND 51-10-04.SDR AT0100207Floor Support · corrodedFOUND FLOOR SUPPORT AT BS 160-218 CORRODED BEYOND LIMITS. CORRECTIVE ACTION: FABRICATED AND INSTALLED REPAIR IAW DC9 SRM 51-30-05.SDR AT0100206Floor Support · corrodedFOUND FLOOR SUPPORT AT BS 205 RBL 22-44 CORRODEDBEYOND LIMITS. CORRECTIVE ACTION: FABRICATED AND INSTALLED REPAIR IAW DC9 SRM 51-30-05.SDR AT0100205Floor Support · corrodedFOUND CABIN FLOOR SUPPORT AT LBL 15 IS CORRODED BEYOND LIMITS AT BS 205-218. CORRECTIVE ACTION: FABRICATED AND INSTALLED REPAIR IAW DC9 SRM 51-30-05.SDR 01FDEA00404Floorbeam · crackedDURING ROUTINE INSP FLT DECK FLOORBEAM WEB AT BS 299, LBL 6 FOUND CRACKED. *S/D* REMOVED, REPLACED AND FAB WEB PER IAW BAC 727 SRM 51-20-1, SRM 51-30-2.SDR 2001UALA01014Floorbeam · corrodedAFT CARGO PIT AT BS 1285, LBL 45-RBL 45, FRAME T-CAP IS CORRODED.SDR 2001UALA00989Floorbeam · corrodedFLOORBEAM CORRODED STA 1016. MAJOR REPAIR ACCOMPLISHED. REPLACED FLOORBEAM UPPER CAP.SDR 2001UALA00986Floorbeam · corrodedFLOORBEAM CORRODED STA 947.5, RBL 30. *S/D* MAJOR REPAIR ACCOMPLISHED. INSTALLED STRAP REPAIR.SDR 2001UALA00972Floorbeam · corrodedFLOORBEAM CORRODED STA 1640, LBL 53. MAJOR REPAIR ACCOMPLISHED. INSTALLED STRAP REPAIR.SDR MWEA010905Floorbeam · gougedGOUGE ON BOTTOM OF CABIN FLOOR BEAM AT STATION 917 ABOUT 2 INCHES RIGHT OF CENTER INTERCOSTAL. FABRICATED, DRILLED AND INSTALLED REPAIR DOUBLERS.SDR AWXA0001844Floorbeam · corrodedaft lav FLOORBEAM BS 986.5 has moderate to severe exfoliated corrosion upper T-cap APPROX 30 sq inch. repaired IAW SRM 53-00-51 fig 202 sht 1-4.SDR AWXA0001843Floorbeam · corrodedaft cabin FLOORBEAM BS 947 has APPROX 1 sq inch corrosion at LBL 11. removed corrosion IAW SRM 53-60-51 fig 101 pg 110 det VII; corrosion exceeded limits IAW SRM 53-60-51 fig 101 pg 110 (max allowed .013 inch, removed .023 inch). repaired damaged area IAW SRSDR AT0100208Floor Support · corrodedFOUND FLOOR SUPPORT AT BS 160-200 CORRODED BEYOND LIMITS. CORRECTIVE ACTION: FABRICATED AND INSTALLED REPAIR IAW DC9 SRM 51-10-04, 51-10-03, 51-20, AND 51-30-02.SDR 2001UALA00980Floorbeam · corrodedTOP OF FLOORBEAM HAS CORROSION. BLENDED MATERIAL LOSS OUT OF LIMITS, AT BS 1016. REMOVED CORROSION. INSTALLED REPAIR STRAP AND NEW INTERCOSTAL. MAJOR REPAIR ACCOMPLISHED.SDR 2001UALA00969Floorbeam · corrodedFLOORBEAM CORRODED AT BS 1006, RBL 15 TO RBL 30. REPLACED FLOORBEAM UPPER T-CAP SECTION. MAJOR REPAIR ACCOMPLISHED.SDR SWAA011682Floorbeam · crackedDURING SCHEDULED 1/4D CHECK, FOUND FLOORBEAM CRACKED AFT CARGO BS 787, STR 27R. REPAIRED FLOORBEAM PER SRM.SDR ASAA0110333Floorbeam · corrodedPAE - DURING SCHEDULED C-CHECK, FOUND FLOORBEAM AT BS 986.5, WATERLINE 208 CORRODED. REPAIRED PER EA. ( M)SDR 0102445517Floorbeam · crackedIN L2 CHECK, FOUND CRACKED FLOORBEAM. REPAIRED PER EA55-183549.SDR 2001UALA01013Floorbeam · corrodedPIT FLOOR T CAP CORRODED BS 1153 RBL 45-LBL 45.SDR SWAA011683Floorbeam · corrodedDURING SCHEDULED 1/4D CHECK, FOUND CORROSION ON FLOORBEAMS AFT CARGO AT BS 860, LBL 8, RBL 3 & RBL 8. REPAIRED FLOORBEAMS PER SWA RA.SDR PCAA0106049Floorbeam · crackedBGM- DURING SCHEDULED A INSPECTION NOSE GEAR WHEEL WELL FLOORBEAM AT STATION X97 FOUND CRACKED. REPAIR STRAP INSTALLED PER DEHAVILLAND REPAIR DRAWING RD 8-53-5817 AS AN INTERIM REPAIR. RD 8-53-1336 IS REQUIRED TO BE INSTALLED WITHIN NEXT 250 HOURS. PERMANENT SDR SWAA011664Floorbeam · corrodedDURING SCHEDULED D-CHECK, FOUND FLOORBEAM CORRODED AT BS 986, WL 208, RBL 30 TO LBL 20. REPAIRED FLOORBEAM PER SWA RA.SDR SWAA011663Floorbeam · corrodedDURING SCHEDULED 1/4D CHECK, FOUND FLOORBEAM CORRODED IN AFT CARGO AT BS 807 & BS 860, LBL 17. REPAIRED FLOORBEAMS PER SRM.SDR ZW0A0103504Floorbeam · corrodedDURING CHECK-C MAINT FOUND CORROSION ON CABIN FLOORBEAM, STA 218 CENTERLINE. REMOVED AND REPLACED FLOOR SUPPORT PER SRM 51-01 PAGE 1.SDR AALA20011199Floorbeam · corrodedTUL - FOUND CORROSION ON UNDERSIDE OF FLOORBEAM AT DOOR SILL AREA FRAME 62 INBOARD OF ROLLOUT DEVICE. CORROSION IS HALF WAY THROUGH FLOORBEAM. INSTALLED FABRICATED SECTION OF FLOORBEAM AT DOOR SILL AREA STATION 4097 (FRAME 62) PER SRM 51-72-10. (M)SDR USAA010606Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED APPROXIMATELY 6 SQUARE INCH AREA NUT PLATE HOLES, BS 345, RBL 12 TO RBL 52. REMOVED DAMAGED AREA, INSTALLED NEW T-CAP PER TYPICAL REPAIR 53-15-01. (M)SDR USAA010607Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 1 INCH AREA, BS 360, RBL 13. REMOVED DAMAGE, INSTALLED DOUBLER PER RM 53-10-51. (M)SDR USAA010612Floorbeam · corrodedCLT - FOUND FLOORBEAM T-CAP CORRODED, APPROXIMATELY 2 INCH BY 6 INCH AREA, BS 324, LBL 23 TO LBL 41. DAMAGE REMOVED, REPAIR STRAP AND SLEEVE INSTALLED PER SRM 53-10-08 FIG 101, 51-20-07, AND EA 69647. (M)SDR USAA010605Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 3 INCH BY 2 INCH AREA OF CORROSION, BS 1320, RBL 22. REMOVED DAMAGED T-CAP, INSTALLED NEW T-CAP PER TYPICAL REPAIR 53-15-01 AND EA 69751. (M)SDR AALA20014040Floorbeam · corrodedAFW - FOUND INNER T-CHORD HAS CORROSION REMOVAL ON UPPER AND LOWER SURFACE. REQUEST APPROVAL TO CONTINUE IN SERVICE AFTER FOLLOWING NOTES LISTED IN 53-60-15-1 SRM PAGE 108. REMOVED EXISTING FASTENER. REMOVED CORROSION PER SRM. (M)SDR ABXA010342Floorbeam · corrodedFLOORBEAM AT STATION 275 LBL 50 HEAVILY CORRODED. REPAIRED FLOORBEAM IAW DC-9 SRM DWG K07411.
Back to JASC 5315