SDR JR2R20201108069Floor Support · corrodedLT FLOOR SILL CORRODE FR 88-FR 90 FOUND TO BE CORRODED OUT OF LIMITS.SDR JR2R20201108057Floor Support · corrodedRT FLOOR SILL BETWEEN FR 88-FR 90 FOUND TO BE CORRODED OUT OF LIMITS.SDR SWAA2021072729001Floor Support · bentAFT CARGO FLOOR FWD BULKHEAD FLOOR ANGLE BENT / REMOVED AND REPLACED PER SRM 51-40-02.SDR SWIA202054624Intercostal · corrodedINTERCOSTAL LOWER FLANGE CORRODED FS 394.00-FS 421.00, BETWEEN STGR 27 & STGR 26R, MARKED. C-CHECK RO 12/14/2020. REMOVED AND INSTALLED NEW INTERCOSTAL AT FS 394.00-FS 421.00, BETWEEN STGR 27 & STGR 26R, REF CRJ 700 SRM DWG. COMPLIED WITH TASK CARD. PRESSUSDR SWIA202054623Intercostal · corrodedINTERCOSTAL CORRODED FS 349.00-FS 364.00 BETWEEN STGR 27 & STGR 26L, MARKED. C-CHECK RO 12/14/2020. REMOVED AND INSTALLED NEW LT SIDE INTERCOSTAL LOCATED BETWEEN FS 349-364, REF DWG CRJ 700 AMM & CRJ 700 SRM. COMPLIED WITH TASK CARD. PRESSURE CHECK GOOD.SDR AALA202011249010Door Sill · corrodedAIRCRAFT IN BASE MAINTENANCE. FOUND SURFACE CORROSION AROUND NUT PLATE HOLE ON BULK CARGO DOOR SILL PLATE, MEASURING 1.00 INCH X 0.750 INCH X 0.035 INCH. REMOVED AND REPLACED BULK CARGO DOOR SILL PLATE, REF SRM 53-41-49-300-002.SDR SCNA20201124330Web · corrodedCORROSION ON WEB LOCATED BETWEEN STA 260 AND STA 270 BL 0 WL 208. REMOVED AND REPLACED WEB LOCATED BETWEEN STA 260-270 BL 0 WL 208 WITH ITEM NR 141A5211U1 PO NR 806895, IAW SRM 51-40-02 AND DWG NR 141A5210.SDR AALA202011099013Floor Support · crackedAIRCRAFT IN BASE MAINTENANCE. CRACK IN FLOOR INTERCOSTAL BETWEEN STA 312 AND STA 328 AT LBL 50, MEASURING L=2.125 IN, W=0.75 IN, D=0.1 IN. REPLACED INTERCOSTAL WITH NEW, IAW SRM 51-40-02.SDR AALA202011099010Floor Support · crackedAIRCRAFT IN BASE MAINTENANCE. CRACK IN FLOOR INTERCOSTAL AT STA 323 AND RBL 31, MEASURING L=1.0 IN, W=0.1 IN. REPLACED INTERCOSTAL WITH NEW, IAW AARD 51-00-05-1.SDR AALA202011099009Floor Support · crackedAIRCRAFT IN BASE MAINTENANCE. CRACK IN FLOOR INTERCOSTAL AT STA 321 AND LBL 45, MEASURING L=1.0 IN, W=0.1 IN. REPLACED INTERCOSTAL WITH NEW, IAW AARD 51-00-05-1.SDR AALA202011099008Floor Support · crackedAIRCRAFT IN BASE MAINTENANCE. CRACK IN FLOOR INTERCOSTAL AT STA 335.5 AND LBL 45, MEASURING L=1.0 IN, W=0.1 IN. REPLACED INTERCOSTAL WITH NEW, IAW AARD 51-00-05-1.SDR DALA2020110903636Floor Support · corrodedDURING INITIAL INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON STRINGER FLOOR SUPPORTS LBL/RBL 2.90 AND RBL 7.55, BETWEEN STA 1495 AND STA 1520 AT AFT CARGO COMPARTMENT. STRINGER FLOOR SUPPORTS REPAIRED, PER SRM.SDR DALA2020110903635Floor Support · corrodedDURING INITIAL INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON FLOOR STRINGERS RBL 10.45 AND RBL 16.10, BETWEEN STA 780 + 60 TO 780 + 70 AT FWD CARGO COMPARTMENT. STRINGERS WERE REPAIRED, PER SRM.SDR SWAA2021072828710Fitting · brokenLWR FUSELAGE RIGHT SIDE STA 1016-5 O/B DRAIN FITTING BROKEN / REMOVED AND REPLACED DRAIN FITTING AT LWR FUSELAGE STA 1016+5' RIGHT SIDE O/B AS PER B737-700 SRM 51-40-02-0G-0 AND DWG 148A3320SDR SWAA2021072136713Floor Support · crackedCABIN FLOOR SUPPORT CRACKED STA 540 AT LBL-1 / REMOVED AND REPLACED PER SRM 51-40-02SDR SWAA2021052528807Gusset · crackedFWD CARGO COMPARTMENT AT STA 500D S-21L GUSSET BRACKET CRACK. 227-009 / REMOVED AND REPLACED GUSSET AT FWD CARGO COMP AT STA 500D S-21L IN REF B737-700 SRM 51-40-02-0G-0 AND DWG #143A9481.SDR SWAA2021052528808Gusset · crackedFWD CARGO COMPARTMENT RH SIDE AT STA 500D S-19R GUSSET BRACKET CRACK. 227-010 / REMOVED AND REPLACED GUSSET AT FWD CARGO COMP FROM STA 500D S-19R IN REF B737-700 SRM 51-40-02-0G-0 AND DWG # 143A9481SDR SWAA2021052528806Gusset · crackedFWD CARGO COMPARTMENT AT STA 500D S-19L GUSSET BRACKET CRACK. 227-008 / REMOVED ANS REPLACED GUSSET AT FWD CARGO COMP FROM STA 500D S-19L IN REF B737-700 SRM 51-40-02-0G-0 AND DWG # 143A9481SDR SWIA202054986Intercostal · corrodedAVIONICS BAY SURROUND FWD INTERCOSTALS CORRODED AT FS 364.00 STGR 27L AND 27R. C-CHECK RO 12/30/2020. REMOVED AND REPLACED INTERCOSTALS AT FS 364 AT STR 27L AND 27R, IAW CRJ 200 SRM. COMPLETED TASK CARD CARD AND ATTACHED COMPLETED FORM 337. NO WEIGHT CHANGSDR SWIA202054969Floor Support · corrodedLT PRESSURE FLOOR SILL SKIN IS CORRODED BETWEEN FS 409+128-FS 559. REFERENCE CONTINUATION CARD FOR SPECIFIC LOCATIONS. C-CHECK RO 12/30/2020. REPAIRED IAW REO. MAJOR REPAIR TASK CARD & FORM M337 ATTACHED. NO MEASUREABLE WEIGHT CHANGE.SDR SWIA202054966Floor Support · corrodedRT PRESSURE FLOOR SILL SKIN HAS CORROSION BETWEEN FS 409+128-FS 559. C-CHECK RO 12/30/2020. REPAIRED IAW REO. MAJOR REPAIR TASK CARD & FORM M337 COMPLETED AND ATTACHED. NO MEASUREABLE WEIGHT CHANGE.SDR SWIA202054464Door Sill · corrodedCORROSION DETECTED ON RT FLOOR SILL, JUST (AFT) OF SERVICE DOOR SURROUND STRUCTURE AT FS 349.00, MARKED. C-CHECK RO 12/04/2020. CUT OUT DAMAGED SECTION OF RT FLOOR SILL JUST AFT OF SERVICE DOOR SURROUND STRUCTURE AT FS 349.00. FABRICATED AND INSTALLED REPAISDR SWIA202054463Striker · corrodedCORROSION DETECTED ON SERVICE DOOR SURROUND STRUCTURE, LOWER SEAL "STRIKER" BETWEEN FS 319.70 AND FS 349.00. AREAS ARE LOCATED AT FASTENER HOLES FOR GALLEY FLOOR PROTECTOR, MARKED. C-CHECK RO 12/04/2020. REMOVED AND REPLACED NEW FITTING SEAL STRIKE P/N SH67SDR AALA202011069014Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE. CORROSION OF INTERCOSTAL AT FASTENER HOLES UNDER FLOOR PANEL BETWEEN STA 951 AND STA 967 AT LBL 20, MEASURING L=2.5 IN, W=2.0 IN, D=0.027 IN. REPLACED INTERCOSTAL WITH NEW, IAW DRAWING 147A5660 AND B737NG SRM 51-40-10-2R. SUPPLSDR SWIA202054218Threshold · corrodedCORROSION FOUND ON FWD PAX DOOR THRESHOLD. C-CHECK RO 11/20/2020. REMOVED AND REPLACED FWD PAX DOOR THRESHOLD WITH NEW PART FROM FACTORY, NO SIGNIFICANT CHANGE TO WEIGHT AND BALANCE, REF EMB175 SRM.SDR DALA2020110903634Floor Support · corrodedDURING INSPECTION CORROSION LEVEL 2 WAS FOUND ON STRINGER LBL 16.10 FROM STA 1360 TO 1380 AT AFT CARGO COMPARTMENT AND REPAIRED, PER SRML.SDR N6WA2020110603Door Sill · corrodedSERVICE DOOR SILL MOUNTING ANGLE HAS CORROSION UNDER LOWER SILL ANGLES. REMOVED AND REPLACED SERVICE DOOR SILL MOUNTING ANGLE, IAW CRJ700 SRM 51-40-06.SDR SWAA2021080336685Panel · corrodedNWW PANEL 113AC LIGHT SURFACE CORROSION ON LANDINGS / REMOVED AND REPLACED PANEL PER M/M 53-14-01; PANEL WILL BE INSTALLED ON ROUTINE CARD J PANEL 115 CLOSESDR SWAA2021080336683Panel · corrodedNWW PANEL 113BW LIGHT SURFACE CORROSION ON LANDINGS / REMOVED AND REPLACED PANEL PER M/M 53-14-01; PANEL WILL BE INSTALLED ON ROUTINE CARD J PANEL 115 CLOSESDR SWAA2021080336684Panel · corrodedNWW PANEL 114AC LIGHT SURFACE CORROSION ON LANDINGS / REMOVED AND REPLACED PANEL PER M/M 53-14-01; PANEL WILL BE INSTALLED ON ROUTINE CARD JPANEL 115 CLOSESDR SWAA2021080336677Panel · corrodedPANEL 192CR HAS CORROSION ON DRAIN MAST BASE. / REMOVED AND REPLACED FWD DRAIN MAST BASE; PANEL 192CR; PER SOPM 20-50-19.SDR SWIA202054724Door Sill · corrodedAFT CARGO DOOR SILL HAS CORROSION IN MULTIPLE PLACES. C-CHECK RO 12/24/2020. REMOVED AND REPLACED AFT CARGO DOOR SILL, IAW MHIRJ REO AND CRJ 700 SRM & SKY CARD NO WEIGHT CHANGE AND FORM M337 IS ATTACHED. REF ATTACHED CONTINUATION CARD FOR DETAILS OF WORK PESDR FDEA202011052776Stiffener · crackedCENTER WING BOX FRONT SPAR VERTICAL STIFFENER AT Y1456 LOWER END CRACKED COMPLIED WITH EA: 6-5710-T0358000 P1. EA TITLE: WINGS-BASIC WING STRUCTURE- CWB FRONT SPAR VERTICAL STIFFENER CRACK AT FR 40, Y1456 LT SIDE-REPAIR. REPAIRED THE CENTER WING BOX FRONT SSDR AALA202011309024Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE. CORROSION OF LT TRANSITION PANEL BETWEEN STA 500A AND STA 500I AT LBL 24, MEASURING L=12.0 IN, W=1.75 IN, D=0.01 IN. REPLACED TRANSITION PANEL WITH NEW, IAW SRM 53-00-53.SDR AALA202011309023Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE. CORROSION OF RT TRANSITION PANEL BETWEEN STA 500A AND STA 500I AT RBL 25, MEASURING L=12.0 IN, W=2.0 IN, D=0.007 IN. REPLACED TRANSITION PANEL WITH NEW, IAW DRAWING 143A7500.SDR SWIA202054361Intercostal · corrodedCENTER INTERCOSTAL CORRODED AT DOOR DATUM 2 OF PAX DOOR. C-CHECK RO 11/24/2020. REMOVED AND REPLACED CENTER INTERCOSTAL AT DATUM 2 OF PAX DOOR, IAW CRJ 200 SRM. COMPLETED TASK CARD AND ATTACHED COMPLETED FORM 337. NO WEIGHT CHANGE NOTED.SDR SWIA202054212Seal Rest · corrodedFWD CARGO DOOR CENTER SEAL REST ON FUSELAGE CORRODED. C-CHECK RO 11/20/2020. REMOVED CORROSION BY BLENDING FWD CARGO DOOR SEAL REST UNDER FUSELAGE, REF E175 SRM. SEE CONTINUATION CARD FOR WORK PERFORMED.SDR SWIA202054211Angle · crackedCRACK IN ANGLE FR 12 LBL 36. C-CHECK RO 11/20/2020. REMOVED AND REPLACED ANGLE AT FR 12, REF SRM.SDR SWIA202054210Angle · crackedCRACK IN ANGLE AT FR 12 BL 0. C-CHECK RO 11/20/2020. REMOVED AND REPLACED ANGLE AT FR 12 BL 0, REF SRM 51-40-08. APPLIED ALODINE SRM TOPCOAT SRM & CPM.SDR SWIA202054208Doubler · corrodedCORROSION, RT OUTBOARD FLOOR DOUBLER CORRODED, AS MARKED FR 14. C-CHECK RO 11/20/2020. REMOVED AND REPLACED RT OUTBOARD FLOOR DOUBLER BETWEEN FRAMES 12-14, REF SRM.SDR SWIA202054207Support · corrodedCORROSION, RT PANEL SUPPORT CORRODED, AS MARKED FR 16. C-CHECK RO 11/20/2020. REMOVED AND REPLACED RT PANEL SUPPORT AT FRAME 16, REF SRM.SDR SWIA202054203Shear Panel · corrodedCORROSION, LT SHEAR PANEL CORRODED, AS MARKED FR 87-88. C-CHECK RO: 11/20/2020. REMOVED AND REPLACED LT SHEAR PANEL BETWEEN FR 87 AND 88, REF EMB175 SRM. SEE CONTINUATION CARD FOR DETAILS OF WORK PERFORMED.SDR SWIA202054202Support · brokenLT OUTBOARD PANEL SUPPORT BROKEN FR 86. C-CHECK RO: 11/20/2020. REMOVED AND REPLACED PANEL SUPPPORT ON FR 86, REF SRM.SDR SWIA202054201Floor Support · corrodedCORROSION, LT OUTBOARD FLOOR SUPPORT CORRODED, AS MARKED FR 84. C-CHECK RO: 11/20/2020. REMOVED AND REPLACED LT OUTBOARD FLOOR SUPPORT AT FR 84, REF SRM. RESTORED SURFACE PROTECTION, REF SRM. REFER TO CONTINUATION CARD FOR ALL WORK ACCOMPLISHED.SDR SWIA202054198Shear Panel · corrodedCORROSION, CENTER SHEAR PANEL CORRODED, AS MARKED FR 87-88. C-CHECK RO: 11/20/2020. REMOVED AND REPLCED SHEAR PANEL. COMPLIED WITH SURFACE PROTECTION, AS REQUIRED, REF SRM.SDR SWIA202054197Gusset · corrodedCORROSION, RT GUSSET CORRODED, AS MARKED FR 91. C-CHECK RO: 11/20/2020. REMOVED AND REPLACED RT GUSSET AT FR 91 AND RESTORED SURFACE PROTECTION, REF SRM. REFER TO CONTINUATION CARD FOR ALL WORK ACCOMPLISHED.SDR SWIA202054195Gusset · corrodedCORROSION, RT INBOARD GUSSET CORRODED, AS MARKED FR 90. C-CHECK RO: 11/20/2020. REMOVED AND REPLACED RT INBOARD GUSSET AT FR 90, REF SRM AND RESTORED SURFACE PROTECTION, REF SRM. REFER TO COTINUATION CARD FOR ALL WORK ACCOMPLISHED.SDR SWIA202054194Gusset · corrodedCORROSION, RT OUTBOARD GUSSET CORRODED, AS MARKED FR 90. C-CHECK RO: 11/20/2020. REMOVED AND REPLACED RT OUTBOARD GUSSET AT FR 90, REF SRM AND RESTORED SURFACE PROTECTION REF SRM.SDR SWIA202054193Support · corrodedCORROSION, RT INBOARD INTERCOSTAL SUPPORT CORRODED, AS MARKED FR 89-90. C-CHECK RO: 11/20/2020. REMOVED RT INBOARD INTERCOSTAL SUPPORT FR 89-90. DRILLED UP NEW INTERCOSTAL SUPPORT, INSTALLED AND APPLIED TOPCOAT, REF EMB SRM. SEE CONTINUATION CARD FOR EVALUSDR SWIA202054191Gusset · corrodedCORROSION, RT INBOARD GUSSET CORRODED, AS MARKED FR 89. C-CHECK RO: 11/20/2020. REMOVED RT INBOARD GUSSET FR 89. DRILLED UP NEW GUSSET, INSTALLED GUSSET AND APPLIED TOPCOAT, REF EMB SRM. SEE CONTINUATION CARD FOR EVALUATION.
Back to JASC 5320