JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2021062928650Scuff Plate · crackedFORWARD CARGO FWD SCUFF PLATE CORNER BROKEN / FORWARD CARGO FWD SCUFF PLATE CORNER WAS REPAIRED ON BACKSHOP WORKORDER 40585-1400-0003 S/N 7705710 SHOP/Y190699SDR SWAA2021062920378Support Angle · corroded***CORROSION*** ON FORWARD ENTRY DOOR SCUFF PLATE OUTBOARD SUPPORT AT B.S. 312-344; L.B.L. 66; W.L. 208.1. / REMOVED CORROSION FROM FED O/B SCUFF PLATE SUPPORT BS312-344; LBL66 WL208.1; ORIGINAL THICKNESS IS .050'; MAX MAT REMOVED IS MORE THAN 30% IN AN AREA OSDR SWAA2021062920379Support Angle · corroded***CORROSION*** ON FORWARD ENTRY DOOR SCUFF PLATE INBOARD SUPPORT AT B.S. 312-344; L.B.L. 64; W.L. 208.1. / REMOVED CORROSION FROM FED I/B SCUFF PLATE SUPPORT BS312-344 LBL64 WL208.1; ORIGINAL THICKNESS .080' MAX MAT REMOVED 5' X 1' X .010' REMAINING THICKNESSSDR SWAA2021041329611Angle · corrodedAFT CARGO COMPARTMENT STA. 727E WL 155 RBL 21 'Z' ANGLE HAS A SPOT OF CORROSION.AFT CARGO COMPARTMENT STA. 727E WL 155 RBL 21 'Z' ANGLE HAS A SPOT OF CORROSION. / REMOVED CORROISON ON AFT CARGO Z ANGLE AT STA 727E RBL 21; .040' ORIG; .038' MAT REMAINING; .002'SDR SWAA2021041329612Angle · corrodedAFT CARGO COMPARTMENT STA. 727E+4' AND STA. 7272E+6' WL 155 RBL 21 'Z' ANGLE HAS TWO SPOTS OF CORROSION. / REMOVED CORROISON ON AFT CARGO Z ANGLE AT STA 727E RBL 21; .040' ORIG; .038' MAT REMAINING; .002' MAT LOSS; RESTORED FINISH REF SRM 53-00-53-1A-2SDR SWAA2021040828617Angle · corrodedAFT CARGO COMPARTMENT BETWEEN STA 727E AND 747+11' WL 156.4 LBL 21.50; TOP SIDE OF L/H Z ANGLE IS CORRODED AS MARKED IN SEVERAL AREAS / PANEL 120ZBC HAS A PUNCTURE; REMOVED PANEL IAW AMM 25-52-09-000-801. VERFIED NEW MATERIAL IAW DWG 453A1210; ATAG #A83690. FASDR SWAA2020042023116Intercostal · corrodedCORROSION ON INTERCOSTAL AT BS 787; RBL 6.5; WL 152 / INTERCOSTAT BS-787-807; RBL-6.5 WL-152 WAS OUT OF LIMITS PER SRM 53-00-53-1A-2 FIG 103. FABRICATED AND LOCATED NEW INTERCOSTAL IAW DWG-146A8132 SH-17 & PL FROM 7075-0 LOT#8891881 HEAT TREATED TO T-62 PO# 78SDR SWAA2020042023110Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT FROM BS 727 TO BS 767; RBL 21; WL 156 / REMOVED CORROSION ON FLOOR TO SIDEWALL SUPPORT BS727 -767 RBL21; WL156 FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 REMOVED FLOOR TO SIDEWALL SUPPORT PER SRM 51-40-02-0G-0 FABRICSDR SWAA2020042023111Support Angle · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT FROM BS 727A TO BS 800; LBL 21; WL 156 / REMOVED CORROSION FROM ACB FLOOR TO SIDEWALL SUPPORT ANGLE BS727A-800 LBL21 IN AREA OF 6' X 3' X 0.013' DEEP ORIGINAL MATERIAL THICKNESS 0.040' FOUND TO BE OUT OF LIMIT IAW SRM 53-SDR SWAA2020042023113Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT FROM BS 867 TO BS 887; RBL 16; WL 156 / REMOVED CORROSION FROM SIDEWALL SUPPORT BS867-887 RBL16; WL156 1' X 3' X 0.014 PER SRM 51-10-02 ORIGINAL THICKNESS OF 0.050' FOUND TO OUT OF LIMITS PER SRM 51-10-02-0G-0 REMOVED PERSDR SWAA2020042023114Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT BS 895; RBL 16; WL 156 / REPLACED FLOOR TO SIDEWALL SUPPORT AT BS880 TO 947 RBL16 WL156 IAW SRM 51-40-02 AND DRAWING 147A7500 DUE TO THE CORROSION 1' X 5' X 0.08' PER SRM 51-10-02-0G-0 ORIGINAL MAX THICKNESS IS 0.040' SDR SWIA2020041750179Bracket · corrodedLH OUTBOARD BRACKET ASSY AT BL45 FS 345 APPROX. HAVE CORROSION AS MARKED. (C-CHECK) RO 4/16/2020 REPLACED L/H AFT CORRODED BRACKET ASSY AT BL45 FS345 WITH NEW BRACKET AND NEW HARDWARE PER CRJ-200 SRM.SDR SWAA2020041523112Shield · corrodedCORROSION ON ACB LOWER MAIN SILL; FWD SHIELD FROM BS 767 TO BS 787; RBL 21; WL 156 / REMOVED CORROSION FROM ACB LOWER MAIN SILL; FWD SHIELD BS767-787 RBL21 2' X 1' X 0.06' FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2. REMOVED DAMAGED SHEILD PER SRM 51-40-02SDR SWAA2020041420384Support · corroded***CORROSION*** ON FLOOR TO SIDEWALL SUPPORT AT B.S. 747-847; W.L. 155; L.B.L. 21. / REMOVED AND REPLACED FLOOR TO SIDEWALL SUPPORT AT B. 727-847; W.L.155; L.B.L.21 PER SRM 51-40-02-0G-0; SRM 51-40-05-0G-0 AND DWG.146A7502SDR SWAA2020041420386Support · corroded***CORROSION*** ON FLOOR TO SIDEWALL SUPPORT AT B.S. 887-947; W.L. 155; R.B.L. 21. / REMOVED AND REPLACED ACB FLOOR TO SIDEWALL SUPPORT BS887 TO BS947 RBL21 IAW SRM 51-40-02 AND DWG 147A7500 89004U 21MAR20SDR SWAA2020041320388Shield · corroded***CORROSION*** ON SHIELD AT B.S. 847-867; W.L. 155; R.B.L. 21. / CORROSION FOUND ON ACB AFT SHIELD BS847-867 RBL-21 WL-155 FOUND TO BE OUT OF LIMIT DUE TO NO LIMIT ON SRM PARTS WILL REPAIRE BY REPLACEMENT IAW SRM 51-10-02-0G-0 PAR.9C LOCATED AND DRILLED NEW SSDR IPXA2020041054027Floor Support · corrodedINSPECTION TYPE:3CCOURIER AREA FLOOR SUPPORT UNDER AFT I/B CORNER OF LAV HAS CORROSION.REMOVED AND REPLACED CORRODED COURIER AREA FLOOR SUPPORT UNDER AFT I/B CORNER OF LAV. BETWEEN STA. Y=392 - Y=440 AND X=-8.5 - X=27.5. IAW MD-11 SRM 51-33-01. (MINOR)SDR SWAA2020040720387Shield · corroded***CORROSION*** ON SHIELD AT B.S. 767-794; W.L. 155; R.B.L. 21. / REMOVED AND REPLACED SHIELD AT BS767-794; W.L.155; RBL21; WITH P/N 146A8127-12; ITEM 7531132 IAW SRM 51-40-02; DWG# 146A0081 59202U 16MAR20SDR SWAA2020040620383Intercostal · corroded***CORROSION*** ON INTERCOSTAL LOWER FLANGE AT B.S. 847-867; JUST ABOVE STRINGER 26 LEFT; L.B.L. 17. REJECTED RESOLUTION DUE TO INCORRECT SRM REPAIR REFERENCE USED. / REPAIRED INTERCOSTAL BS 847-867 STR 26L LBL 17 IAW SRM 53-00-53-1A-2 FIG 103 DETAIL 'E'. 8057SDR SWAA2020033133395Nut Plate · missingAFT CARGO COMPARTMENT BETWEEN STA 727J AND 727C R/H Z ANGLE HAS 10 EA GLUE ON NUTPLATES MISSING / FABRCIATED AND INSTALLED NEW ZEE ANGLE PER W/O # 40583/1600/0013 DEFECT NO Y190648SDR SWAA2020033133394Nut Plate · missingAFT CARGO COMPARTMENT BETWEEN STA 727I AND 767 R/H Z ANGLE HAS 10 EA GLUE ON NUTPLATES MISSING / FABRICATED AND INSTALLED NEW ZEE ANGLE PER W/O # 40583/1600/0013; DEFECT NO Y190648SDR SWAA2020033128614Angle · corrodedAFT CARGO COMPARTMENT BETWEEN STA 727J AND 767 WL 156.4 RBL 21; TOP SIDE OF R/H Z ANGLE IS CORRODED AS MARKED IN SEVERAL AREAS / FABRICATED & INSTALLED NEW ZEE ANGLE PER W/O# 40583/1600/0013; DEFECT NO Y190648 P/N 146A7502-56SDR SWAA2020033128613Angle · corrodedAFT CARGO COMPARTMENT BETWEEN STA 727H AND 727J+11' WL 156.4 RBL 21; TOP AND BOTTOM SIDES OF R/H Z ANGLE IS CORRODED AS MARKED IN SEVERAL AREAS / FABRICATED & INSTALLED NEW ZEE ANGLE PER W/O # 40583/1600/0013; DEFECT NO 4190648.SDR AALA2020032759012Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CARGO COMPARTMENT TRANSITION PANEL BETWEEN BS 500H AND BS 500I AT S25R. REPLACED TRANSITION PANEL PER SRM 53-00-53-2R.SDR AALA2020032759005Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CARGO COMPARTMENT TRANSITION PANEL BETWEEN BS 500 AND BS 500A AT S25R. REPLACED TRANSITION PANEL PER AARD 51-10-05-1.SDR SWAA2020032442766Shield · corrodedAFT CARGO COMPARTMENT BETWEEN STA 767 AND 787 WL / 156.4 BETWEEN RBL 20.50 AND RBL 24 FWD FLOOR / SHIELD IS CORRODED TOP AND BOTTOM SIDES AS MARKED REMOVED CORROSION FROM FLOOR SHIELDS STA 767 AND STA 787 RBL 20.50" AND RBL 24" AFT CARGO COMPARTMENT OSDR SWAA2020032442765Angle · corrodedAFT CARGO COMPARTMENT BETWEEN STA 807 AND 747+11" / WL 156.4 LBL 21.50; TOP AND BOTTOM SIDES OF L/H Z / ANGLE IS CORRODED AS MARKED IN SEVERAL AREAS FABRCIATED & INSTALLED NEW ZEE ANGLE PER W/O # 40583/1600/0009 DEFECT NO Y190638. ORIGINAL THICKNESS .SDR SWAA2020032442764Nut Plate · missingAFT CARGO COMPARTMENT BETWEEN STA 727C AND 727 R/H Z ANGLE HAS 4 EA GLUE ON NUTPLATES MISSING ACCOMPLISHED FABRICATION REPLACING ZEE ANGLE ON W/O #40583/1600/0013, DEFECT NO Y190643 P/N 146A75 02-56SDR SWAA2020032442763Angle · corrodedAFT CARGO COMPARTMENT BETWEEN STA 727 AND 727B RBL 21 WL 156.4 R/H Z ANGLE HAS SEVERAL AREAS OF CORROSION TOP SKIN AS MARKED REMOVED CORROSION ON R/H ZEE ANGLE STA 727 TO 767, RBL 21 & EVALUATED MATERIAL LOSS & FOUND TO BE OUT OF LIMIT I.A.W SRM 53-00-5SDR SWAA2020032442675Support · corroded***CORROSION*** ON FLOOR TO SIDEWALL SUPPORT AT B.S. 747-767, W.L. 155, R.B.L. 21. REMOVED AND REPLACED FLOOR TO SIDEWALL SUPPORT AT B.S. 727-767. W.L 155, R.B.L.21 PER SRM 51-40-02-0G-0 AND DWG 146A7500. 59366U, 03/19/20.SDR SWAA2020032442674Floor Support · crackedCRACKED FLOOR SUPPORT AT B.S. 312-328, R.B.L. 35, W.L. 208.1. REMOVED AND REPLACED FLOOR SUPPORT AT BS312-328, RBL 35 WL208.1 IAW SRM 51-40-02-0G-0. 84632U, 15MAR20.SDR SWAA2020032442673Floor Support · crackedCRACKED FLOOR SUPPORT AT B.S. 328-344, L.B.L. 46, W.L. 208.1. REMOVED AND REPLACED FLOOR SUPPORT AT BS 328-344 LBL 46 WL 208.1 IAW SRM 51-40-02-0G-0 DWG 141A5400SDR CALA2020032000630Fitting · crackedSHEAR FITTING AT STA 540 RBL 6.14 IS CRACKED LP 6481184 SPT REMOVED AND REPLACED SHEAR FITTING IAW B737-700 SRM 51-40-02 AND ECRA 5714-01109. DATA WAS TRANSCRIBED FROM 6481184, WORK ACCOMP LISHED, INSPECTED. SSFR REPORT FORM 46-002 4 ENTERED BY UAL INSPECTION SDR CALA2020032000629Fitting · crackedSHEAR FITTING AT STA 540 RBL 40.87 IS CRACKED LP 6481187 SPT REMOVED AND REPLACED SHEAR FITTING IAW B737-700 SRM 51-40-02 ECR A 5714-01112. DATA WAS TRANSCRIBED FROM 6481187, WORK ACCOMPLISH ED, INSPECTED. SSFR REPORT FORM 46-0024 E NTERED BY UAL INSPECTION 0SDR CALA2020032000628Fitting · crackedSHEAR FITTING AT STA 540 RBL 54.60 IS CRACKED LP 6481193 SPT REMOVED AND REPLACED SHEAR FITTING IAW B737-700 SRM 51-40-02 AND ECRA 5714-01113. DATA WAS TRANSCRIBED FROM 6481193, WORK ACCOMP LISHED, INSPECTED. SSFR REPORT FORM 46-00 24 ENTERED BY UAL INSPECTIOSDR CALA2020032000623Fitting · crackedSHEAR FITTING AT STA 540 LBL 6.14 IS CRACKED LP 6481188 SPT REMOVED AND REPLACED SHEAR FITTING IAW B737-700 SRM 51-40-02 AND ECRA 5714-01104. DATA WAS TRANSCRIBED FROM 6481188, WORK ACCOMP LISHED, INSPECTED, SSFR REPORT FORM 46-002 4 ENTERED BY UAL INSPECTION SDR CALA2020032000627Fitting · crackedSHEAR FITTING AT STA 540 RBL 32.40 IS CRACKED LP 6481186 SPT REMOVED AND REPLACED SHEAR FITTING IAW B737-700 SRM 51-40-02 AND ECRA 5711-01111. DATA WAS TRANSCRIBED FROM 6481186, WORK ACCOMP LISHED, INSPECTED. SSFR REPORT FORM 46-00 24 ENTERED BY UAL INSPECTISDR CALA2020032000626Fitting · crackedSHEAR FITTING AT STA 540 LBL 54.60 IS CRACKED LP 6481192 SPT REMOVED AND REPLACED SHEAR FITTING IAW B737-700 SRM 51-40-02 AND ECRA 5714-01108, DATA WAS TRANSCRIBED FROM 6481192, WORK ACCOMP LISHED, INSPECTED. SSFR REPORT FORM 46-002 4 ENTERED BY UAL INSPECTIONSDR CALA2020032000625Fitting · crackedSHEAR FITTING AT STA 540 LBL 40.87 IS CRACKED LP 6481191 SPT REMOVED AND REPLACED SHEAR FITTING IAW B737-700 SRM 51-40-02 AND ECRA 5714-01107. DATA WAS TRANSCRIBED FROM 6481191, WORK ACCOMP LISHED INSPECTED SSFR REPORT FORM 46-002 4 ENTERED BY UAL INSPECTION 0SDR CALA2020032000624Fitting · crackedSHEAR FITTING AT STA 540 LBL 32.40 IS CRACKED LP 6481190 SPT REMOVED AND REPLACED SHEAR FITTING IAW B737-700 SRM 51-40-02 AND ECRA 5714-01106. DATA WAS TRANSCRIBED FROM 6481190, WORK ACCOMP LISHED INSPECTED. SSFR REPORT FORM 46-00 24 ENTERED BY UAL INSPECTIONSDR CALA2020032000622Fitting · crackedSHEAR FITTING AT STA 540 RBL 15.04 IS CRACKED LP 6481185 SPT REMOVED AND REPLACED SHEAR FITTING IAW B737-700 SRM 51-40-02 AND ECRA 5714-01110 DATA WAS TRANSCRIBED FROM 6481185, WORK ACCOMPL ISHED INSPECTED. SSFR REPORT FORM 46-0024 ENTERED BY UAL INSPECTION 03SDR CALA2020032000621Fitting · crackedSHEAR FITTING AT STA 540 LBL 15.04 IS CRACKED LP 6481189 SPT REMOVE AND REPLACED SHEAR FITTING IAW B737-700 SRM 51-40-02 AND ECRA 5714-01105, DATA WAS TRANSCRIBED FROM 6481189, WORK ACCOMPL ISHED SSFR REPORT FORM 46-0024 ENTERED BY UAL INSPECTION 03/10/20 INSPSDR SWAA2020031742535Threshold · corrodedAFT CARGO COMPARTMENT BETWEEN STA 787+7.50" AND 847 WL 156.4 RBL 28 TO RBL 20 CARGO DOOR LOWER CUTOUT; TRESHOLD WEB IS CORRODED IN SEVERAL AREAS TOP SKIN AS MARKED AFT CARGO COMPARTMENT, REMOVED CORROSION ON THRESHOLD WEB. IAW SRM 51-10-02-0G-0, VERIFIESDR SWAA2020031742523Angle · corrodedAFT CARGO COMPARTMENT STA. 727F+5.3/4 WL 155 RBL 21 Z ANGLE HAS CORROSION. ACCOMPLISH R/H Z ANGLE REPAIR ON WORK CARD Y175976 VERIFIED MATERIAL LOSS ORG T .040" LOSS OF .008" FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 P/N 146A7502-34SDR SWAA2020031742522Angle · corrodedAFT CARGO COMPARTMENT STA. 727F+2" WL 155 RBL 21 Z ANGLE HAS CORROSION. ACCOMPLISH R/H Z ANGLE REPAIR ON WORK CARD Y175976 VERIFIED MATERIAL LOSS ORG T .040" LOSS OF .006" OUT OF LIMITS IAW SRM 52-00-53-1A-2. P/N 146A7502-34SDR SWAA2020031742521Angle · corrodedAFT CARGO COMPARTMENT STA. 727E+10.5" WL 155 RBL 21 "Z" ANGLE HAS CORROSION. ACCOMPLISHED R/H Z ANGLE REPAIR ON WORKCARD / Y175976 VERIFIED MATERIAL ORG T ".40 .007 LOSS OF / MATERIAL FOUND TO BE OUT OF LIMITS IAW SRM / 53-00-53-1A-2 P/N 146A7502-34SDR SWAA2020031642468Angle · corrodedAFT CARGO COMPARTMENT STA. 727H TO STA. 807 WL 155 LBL 21 Z ANGLE HAS CORROSION. FOUND CORROSION ON AFT CARGO LH 2 ANGLE OUT OF LIMITS AT STA 807, 100% MAT LOSS, .040 ORIG. REPAIRED Z ANGLE REF SRM 53-00-53-2R-5 DWG 146A7502-33. ACCOMPLISH NUTPLATE TESTSDR SWAA2020031642467Angle · corrodedAFT CARGO COMPARTMENT STA. 727G TO STA. 767 WL 155 RBL 21 Z ANGLE HAS CORROSION. REMOVED AND REPLACED AFT CARGO COMP R/H Z ANGLE AT STA 727E+8-767WL 155 RBL 21. DUE TO CORROSION IAW SRM 53-00-53-1A-2 ORG T IS .040" MATERIAL LOSS .015" FOUND TO BE OUT OFSDR SWAA2020031642466Angle · corrodedAFT CARGO COMPARTMENT STA. 727F+12" WL 155 RBL 21 Z ANGLE HAS CORROSION. ACCOMPLISH R/H Z ANGLE REPAIR ON WORK CARD Y175976 VERIFIED MATERIAL LOSS ORG T ".040" LOSS OF .008" FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2SDR DALA2020031001804Panel · corroded(AIRCRAFT 5648, L/P 1523534) CORROSION OUT OF LIMIT: CORROSION ON LH SIDE PANEL STA. 1242 AT AFT CARGO COMPARTMENT. CORRECTIVE ACTION: CORROSION LEVEL 2. SIDE PANEL WAS REPAIRED PER B757-200 SRM 53-00-53-2R-2 REPAIR 2.
Back to JASC 5320