SDR SWAA2019102838283Channel · corrodedAFT CARGO COMPARTMENT STRUCTURE SURFACE CORRODED AT BS. 727E FRAME BELOW UPPER WEB FLANGE SURFACE, JUST ABOVE STR. 25R. / REPAIRED Z CHANNEL PER SRM AND DWG.SDR SWAA2019102838282Channel · corrodedAFT CARGO COMPARTMENT STRUCTURE SURFACE CORRODED BETWEEN BS. 727A TO BS. 767 FRAME BELOW UPPER WEB FLANGE SURFACE, JUST ABOVE STR. 25R. / REPAIRED Z CHANNEL PER SRM AND DWG.SDR REXA2019102491481Strap · corrodedINITIAL INSPECTION: CORROSION ON SETTLEMENT AREA AT PANEL ACCESS 193AB AND 195AB (SM).
SUMMARY: ON NRC. 00110, ON SETTLEMENT AREA AT PANEL ACCESS 193AB AND 195AB, STRAPS WERE REPLACED PER CRJ-900 SRM 51-42-10-001-001-A01 PAR. 8SDR REXA2019102391550Angle · corroded"AWR; [ TASK R53520 STEP 7 ]; INITIAL INSPECTION: CORROSION ON MID CAP ANGLE [ JUMPER/PROX-SENSOR/CONNECTOR-WIRING ANGLE ] IN STA. FS= 310 TO FS= 349 AND 41LBL AT MAIN ENTRANCE DOOR LOWER SILL, FWD WET AREA. (W1) (CPAX) SDR REXA2019102391549Angle · corroded"AWR; [ TASK R53520 STEP 7 ]; INITIAL INSPECTION: CORROSION ON KICKPLATE ANGLE IN STA. FS= 310 TO FS= 349 AND 41LBL AT MAIN ENTRANCE DOOR LOWER SILL, FWD WET AREA. (W1) (CPAX)
"
"CORROSION LEVEL 2. KICKPLATE ANGLE IN STA. SDR REXA2019102391526Step · corroded"AWR: OUT OF LIMITS: [ DURING EVALUATION/MEASURE OF LH FWD/AFT SILL STEP PLATE RELATED WITH NRC 00324 ]: CORROSION ON SILL STEP PLATE AT LH FWD/AFT EMERGENCY EXIT SURROUNDING STRUCTURE. (CPAX)TCI: 53-20-258
"
"CORROSION LEVEL 2. SILL STEP PLATE AT LH FWSDR R61A2019102341126Floor Support · corrodedCENTER FUSELAGE III PAX CABIN FLOOR STRUCTURE LONGITUDINAL BEAM FOUND CORRODED AT FR 87-88 RBL 12. REMOVED AND REPLACED BEAM IAW 51-43-03. PSE 53-23-005SDR SWAA2019101737972Channel · crackedCHANNEL CRACKED AT BS. 914, RBL 12. / R&R CHANNEL PER SRM AND DWG.SDR SWAA2019101737971Channel · crackedCHANNEL CRACKED AT BS. 918, RBL 12. / R&R CHANNEL PER SRM AND DWG.SDR AALA201910159063Floor Support · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FORWARD WET AREA FLOOR INTERCOSTAL BETWEEN BS 277 AND BS 294 AT BL 0. REPLACED INTERCOSTAL PER AARD 51-00-05-1.SDR AALA201910159062Floor Support · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED CABIN FLOOR SUPPORT AT BS 540 AND RBL 2. REPLACED FLOOR SUPPORT PER SRM 51-40-02.SDR AALA201910159059Floor Support · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED CABIN FLOOR SUPPORT AT BS 540 AND LBL 2. REPLACED FLOOR SUPPORT PER SRM 51-40-02.SDR A6WA2019101546923Floor Support · corrodedFLOOR SILL AT FS 310 BY PAX DOOR HAS CORROSION. REMOVED AND REPLACED DOUBLER IAW CRJ-200 SRM 51-42-10SDR AALA201910109023Shear Web · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED RIGHT HAND SHEAR WEB AT FR 68 AND S23R. REPLACED SHEAR WEB PER AARD 51-20-01-1.SDR DALA2019101005819Bracket · corrodedEXCESSIVE CORROSION ON LOWER BRACKET BTW STA Y=1022 AND 1037 AT AFT CARGO COMPARMENT. (CCT). NRC 00646: CORROSION LEVEL 2, LOWER BRACKET BTW STA Y=1022 AND 1037 AT AFT CARGO COMPARMENT WAS REPLACED PER B717-200 SRM 51-41-02-0G AND DWG #5936667 REV. BU.SDR SWAA2022040558357Angle · corrodedFORWARD SERVICE DOOR FLOOR STRUCTURE Z ANGLE HAS CORROSION. (MARKED) / E104615-SCHNECK; WILLIAM - 10/13/2019 14:54 COMPLETE: REPLACED OUTER CHORD ANGLE PER SRM 51-40-02.SDR SWAA2022040119525Scuff Plate · crackedFWD CARGO BAY AFT CORNER SCUFF PLATE IS CRACKED / REPAIRED SCUFF PLATE IAW SW EA 1-A53-2076 REV; 11 59581U 15OCT19SDR SWAA2022040119524Scuff Plate · crackedFWD CARGO BAY FWD CORNER SCUFF PLATE IS CRACKED / REPAIRED SCUFF PLATE IAW SW EA 1-A53-2076 59581U 15OCT19 REV.11 59581U 15OCT19SDR SWAA2022040186194Scuff Plate · crackedFWD CARGO DOOR CUTOUT AFT SCUFF PLATE CRACKED / REPAIRED FWD CARGO DOOR CUT OUT AFT SCUFF PLATE CORNER BY OUTSIDE (JL WELDING INC. W.O 15762) IRW SOUTHWEST EA # 1-A53-2076 REV. 11SDR SWAA2022040585007Strap · corroded***CORROSION*** ON TENSION STRAP AT AFT CARGO BAY BS 847 RBL8 WL163. MARKED / AREAS FOUND TO BE OUT OF LIMITS IAW SRM 53-60-15-1A-1 FIG 103.D LOCATED AND DRILLED REPLACEMENT TENSION STRAP AT AFT CARGO BAY BS785- 862; RBL8; WL163; IAW SRM 51-40-05-0G-0; INSTALLSDR C77A202002048040Panel · corrodedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING AFT CABIN FLOOR STRUCTURE: P/N 170-92907-001 LH PANEL SUPPORT, P/N 170-92856-001 FLOOR DOUBLER, P/N 170-92908-001 FLOOR DOUBSDR C77A2020012800039Panel · corrodedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING AFT CABIN FLOOR STRUCTURE: P/N 170-92907-001 LH PANEL SUPPORT, P/N 170-92856-001 FLOOR DOUBLER, P/N 170-92908-001 FLOOR DOUBSDR C77A2020012800037Floor Support · corrodedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING AFT CABIN FLOOR STRUCTURE: P/N 170-92907-001 LH PANEL SUPPORT, P/N 170-92856-001 FLOOR DOUBLER, P/N 170-92908-001 FLOOR DOUBSDR A6WA2019112047009Stiffener · crackedFOUND FS409+128 VERTICAL POST AT BL0.00 LEFT SIDE HAS INDICATION .400 LONG 80% FSH AT AFT FLANGE RADIUS, FAILS NDT. AIRCRAFT REMOVED FROM SERVICE REPLACED FS409+128 BL0.00 VERTICAL POST LEFT SIDE IAW CRJ200 SRM 51-42-06 AND BOMBARDIER REO 601R-53 41-889 REVSDR A6WA2019112047010Stiffener · crackedFOUND FS409+128 VERTICAL POST BL0.00 RIGHT SIDE HAS INDICATION NOTED .300 LONG 70% FSH AT AFT FLANGE RADIUS, FAILS NDT. AIRCRAFT REMOVED FROM SERVICE REPLACED FS409+128 VERTICAL POST AT BL0.00 RIGHT SIDE IAW CRJ200 SRM 51-42-06 AND BOMBARDIER REO 601R53-41-8SDR A6WA201911147007Angle · corrodedPAX DOOR UPPER SILL ANGLE IS CORRODED AROUND THE PROX SENSOR,& NUTPLATE FWD OF PROX SENSOR. AIRCRAFT REMOVED FROM SERVICE REPLACED PAX DOOR SILL ANGLE IAW CRJ200 SRM 51-42-06.SDR IPXA2019103098431Floor Support · corrodedINSPECTION TYPE:2CAFT CARGO FLOOR SUPPORT ANGLE IS CORRODED BETWEEN STA. 1902-16-967 R/H SIDE.REMOVED, FABRICATED AND REPLKACED SUPPORT ANGLE IAW DWG. AGA3857 AND SRM 51-35-01. (MINOR)SDR IPXA2019102868313Support Bracket · crackedINSPECTION TYPE:SEGBROKEN BRACKET AT CARGO STA 5L FWD CABINREMOVED & INSTALLED BRACKETSDR IPXA2019102548238Floor Support · corrodedINSPECTION TYPE:2CAFT CARGO FLOORBOARD LANDING HAS CORROSION AT STA. 1887 L/H SIDE.REMOVED, FABRICATED AND REPLACED LANDING IAW DWG. AGA3857 AND SRM 51-35-01. (MINOR)SDR SWAA2019102538186Angle · corrodedR2 DOOR FLOOR STRUCTURE Z ANGLE CORRODED. / REPAIRED Z ANGLE PER SRM.SDR AALA201910259026Floor Support · corrodedAIRCRAFT IN BASE VISIT: CORROSION ON INTERCOSTAL AT STA 986-1006, LBL31. INSTALLED NEW INTERCOSTAL IAW SRM 53-70-51-2R-5 AND SRM 51-40-02.SDR REXA2019102381548Striker · corroded"AWR; [ TASK R53520 STEP 7 ]; INITIAL INSPECTION: CORROSION ON LOWER STRIKER IN STA. FS= 319 TO FS= 349 AND 44RBL AT GALLEY SERVICE DOOR LOWER SILL, FWD WET AREA. (W1) (CPAX)
"
"CORROSION LEVEL 2.LOWER STRIKER IN STA. FS=SDR REXA2019102381542Support Angle · corroded"AWR; [ TASK R53520 STEP 7 ]; INITIAL INSPECTION: CORROSION ON PROTECTION PLATE SUPPORTS ANGLE IN STA. FS= 346 BETWEEN 41RBL TO 44RBL AT GALLEY SERVICE DOOR LOWER SILL, FWD WET AREA. (W1) (CPAX)
"
"CORROSION LEVEL 1. ON SUPPORT ANGLE IN STASDR SWAA2019102338138Angle · crackedFORWARD ENTRY DOOR FLOOR STRUCTURE Z ANGLE CRACKED AT BS. 303.9. / R&R Z ANGLE PER SRM.SDR REXA2019102381525Support · damaged"AWR; PER MTC REQUEST: [ DURING REMOTION OF MLG WHEEL BINS RELATED WITH TASK 900-27-900-112 STEP 5 ]: ELONGATED HOLE IN RH FAIRING SUPPORT IN STA. FS= 797 TO FS= 807 AND 35RBL AT RH MLG WHEEL WELL. (FYT)
"
"SUMMARY: FAIRING SUPPORT IN STA. FS= 797 TSDR IPXA2019102348196Angle · crackedINSPECTION TYPE:2CCENTER CARGO L/H SIDE FLOOR SUPPORT ANGLE IS CRACKED AT STA. 1781.REMOVED, FABRICATED AND REPLACED ANGLE IAW DWG.AFA7295 AND SRM 51-33-01. (MINOR)SDR IPXA2019102348195Stiffener · crackedINSPECTION TYPE:2CAFT CARGO R/H SIDE VERTICAL STIFFNER IS CRACKED AT STA. 1841.REMOVED, FABRICATED AND REPLACED STIFFNER IAW DWG. AGA7170 AND SRM 51-33-01. (MINOR)SDR SWAA2019102238124Web · corrodedAFT CARGO BAY INTERCOSTAL CORRODED BETWEEN BS. 767 TO BS. 787, RBL 5. / R&R INTERCOSTAL WEB IAW SRM.SDR SWAA2019102238080Floor Support · crackedFLOOR SUPPORT CRACKED BETWEEN BS. 344 TO BS. 360, BL 0. / R&R INTERCOSTAL PER SRM.SDR SWAA2019102213878Floor Support · crackedFLOOR SUPPORT CRACKED BETWEEN BS. 294 TO BS. 312, RBL 16. / R&R FLOOR SUPPORT PER SRM.SDR SWAA2019102238075Door Sill · corrodedR2 LOWER SILL INNER CHORD CORRODED BETWEEN BS. 951 TO BS. 992.8. / R&R INNER CHORD PER SRM & DWG.SDR AALA2019102219034Web · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CARGO DOOR CUT OUT LOWER THRESHOLD WEB BETWEEN BS 793 AND BS 847 AT RBL 26. REPLACED WEB PER AARD 51-00-05-1.SDR SWAA2019102138014Support · corrodedAFT CARGO BAY FLOOR TO SIDEWALL SUPPORT CORRODED BETWEEN AT BS. 727+4 TO BS. 767, RBL 21. / R&R SUPPORT ASSEMBLY PER DWG AND SRM.SDR SWAA2019102138012Support · corrodedAFT CARGO BAY FLOOR TO SIDEWALL SUPPORT CORRODED BETWEEN BS. 727 TO BS. 847, LBL 21. / R&R SUPPORT PER SRM & DWG.SDR SWAA2019102138010Support Angle · corrodedBULKHEAD TO FLOOR PANEL LOWER SUPPORT ANGLE CORRODED AT BS. 947, RBL 20. / R&R ANGLE PER DWG AND SRM.SDR SWAA2019102137998Intercostal · crackedINTERCOSTAL CRACKED BETWEEN BS. 312 TO BS. 328, RBL 31. / R&R INTERCOSTAL PER SRM AND DWG.SDR SWAA2019101767963Support Angle · corrodedFORWARD ENTRY DOOR THRESHOLD WEB SUPPORT Z ANGLE CORRODED. / R&R ANGLE PER SRM.SDR SWAA2019101637884Shield · corrodedFORWARD SHIELD CORRODED AT AFT CARGO BAY BETWEEN BS. 767 TO BS. 787, RBL 21. / R&R SHIELD IAW SRM AND DWG.SDR SWAA2019101657838Floor Support · crackedFLOOR SUPPORT INTERCOSTAL CRACKED BETWEEN BS. 294 TO BS. 277, BL 0. / R&R INTERCOSTAL IAW SRM AND DWG.SDR SWAA2019101657837Floor Support · corrodedAFT WET AREA LONGITUDINAL T FITTING FLOOR SUPPORT CORRODED BETWEEN BS. 947.5 TO BS. 967, RBL 8. / R&R FLOOR SUPPORT PER DWG.