SDR REXA2019101421459Floor Support · corrodedINITIAL INSPECTION:CORROSION ON FLOOR BEAM LBL 27 BTW STA FS:1015 AND 1030 AT AFT CARGO COMPARTMENT FLOOR BEAM LBL 27 BTW FS1015/1030 AT AFT CARGO COMPARTMENT WAS REPAIRED PER CRJ-900 SRM 53-00-41-201-001-A03, SRM 51-42-20-001-001-A01 AND SRM 51-42-06-001-001SDR REXA2019101421439Intercostal · corrodedCORROSION ON STRINGER 25RH IN STA. FS= 280 TO FS= 310 AT MAIN AVIONICS COMPARTMENT. THE STRINGER WAS REPLACED PER CRJ 900 SRM 51-42-06-001-001-A01SDR REXA2019101421422Intercostal · corrodedCORROSION ON INTERCOSTALS (2EAS) BTW FS 394-409, LBL3-RBL3. INTERCOSTALS (2EAS) BTW FS 394-409, LBL3-RBL3. WERE REPLACED PER CJ900 SRM 51-42-06. AND SRM 51-42-20.SDR AALA201910119012Floor Support · crackedAIRCRAFT IN BASE MAINTENANCE: CABIN FLOOR INTERCOSTAL CRACKED AT BS 750 AND LBL 40. REPLACED INTERCOSTAL PER AARD 53-30-00-1.SDR AALA2019100879056Intercostal · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED RIGHT HAND FORWARD DOOR CUT OUT INTERCOSTAL AT FR 16, S10R AND DOOR STOP #7. REPLACED INTERCOSTAL PER SRM 51-72-11.SDR AALA2019100879055Intercostal · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED LEFT HAND FORWARD DOOR CUT OUT INTERCOSTAL AT FR 16 AND DOOR STOP #7. REPLACED INTERCOSTAL PER SRM 51-72-11.SDR CALA2019100501700Gusset · damagedRH FR68 ON 3RD GUSSET FROM THE TOP ON BOTTOM HOLE HAS REJECTABLE DAMAGE INDICATION. REPAIR REQUIRED PRIOR TO NEXT FLIGHT CYCLE S UPPORT TASK AD RELATED (2015-05-02) PER HAECO LCQ NR 9292205 GEN ERATED BY V916887 REPLACED GUSSET ON R2 PASSENGER DOOR AT FR68 STRSDR DALA2019100435713Intercostal · cracked(AIRCRAFT 6811, L/P 1297476) CRACKED INTERCOSTAL STA 680 IN PROYECTION STRINGER 12LH (BESIDE L2 DOOR) AT PAX CABIN. SUMMARY OF NRC 00702 (CRACK WITH 1.100" LENGTH ) INTERCOSTAL WAS REPLACED PER B757-200 SRM 51-40-02 PAR 4 AND 7 AND DWG 143N8334, REV. M.SDR DALA2019100435677Intercostal · crackedCRACK INDICATION ON INTERCOSTAL ON UPPER AND LOWER INBOARD HOLES OF DOOR STOP FITTING NUMBER 7 ON FRAME 16 LT IN PASSENGER CABIN (CRACK DIRECTION IS 3 AND 6 O'CLOCK), REPLACED INTERCOSTAL ON STOP FITTING NUMBER 7 ON FRAME 16 LH IN PASSENGER CABIN AS PER SRM 51SDR DALA2019100205633Floor Support · corrodedCORRODED FLOOR SUPPORT BETWEEN FRAMES 64 TO 66+4 INCHES, +Y 129. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, AND DRAWING D53472815.SDR DALA2019100205632Floor Support · corrodedCORRODED FLOOR SUPPORT BETWEEN FRAMES 66+4 INCHES TO 67+ 16 INCHES, +Y1292. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, AND DRAWING D53472780.SDR DALA2019100205631Floor Support · corrodedCORRODED FLOOR SUPPORT BETWEEN FRAMES 12 TO 24, -Y765. REPLACED THE FLOOR SUPPORT IAW SRM 51-42-11, 51-72-11, AND DRAWING D53112812.SDR DALA2019100205630Floor Support · corrodedCORRODED FLOOR SUPPORT BETWEEN FRAMES 67+16 INCHES TO 69 +3 INCHES, +Y 1292. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, AND DRAWING D53472780.SDR DALA2019100205629Floor Support · corrodedCORRODED FLOOR SUPPORT BETWEEN FRAMES 64 TO 66, +Y1292. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, SRM 51-42-00, AND DWG D53472780.SDR DALA2019100205628Floor Support · corrodedCORRODED FLOOR SUPPORT LOCATED BETWEEN FRAMES 12 TO 24, Y1292. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, AND DWG D53112812.SDR DALA2019100205627Floor Support · corrodedCORROSION FLOOR SUPPORT, BETWEEN FRAMES 12 TO 24, Y+ 254. REPLACED THE FLOOR SUPPORT IAW SRM 51-42-00, SRM 51-72-11, AND DRAWING D53110984.SDR SWAA2022032950462Bracket · crackedAFT CARGO BAY BULKHEAD SUPPORT BRACKET CRACKED BS 867 WL 160 LBL12 / REMOVED ACB BULKHEAD SUPPORT BRACKET CRACKED AT BS 867 WL 160 LBL 12. LOCATED AND DRILLED CLIP AND REINSTALLED NEW CLIP IAW SRM 51-40-02-0G-0; SRM 51-40-0G-0G-0; DWG 149A8102 ID:15 REV A 9295SDR SWAA2022032950461Fitting · corroded***CORROSION*** ON WASTE DRAIN FITTING AT B.S. 997; STR.25L; W.L. 148. / NO ALLOWABLE LIMITS IN SRM. PART REPAIRED BY REPLACEMENT PER SRM 51-10-02. REMOVED AND REPLACED WASTE DRAIN FITTING BS 997 STR 25L WL 148 IAW SRM 51-40-02 AND DWG 147A7443.SDR SWIA2019103046629Floor Support · corrodedFLOORBEAM CAP AT RBL27 BEWTWEEN FS 621 AND FS 589 HAS MULTIPLE AREAS OF CORROSION (C-CHECK) RO: 10/26/2019 REPAIRED RBL 27 FLOORBEAM BETWEEN FS589 AND FS 621 AREAS A,B,C,AND F IAW REO.SDR SWIA2019103046628Floor Support · corrodedFLOORBEAM CAP AT LBL27 IS CORRODED IN MULTIPLE AREAS FROM FS621 TO FS559+112 (C-CHECK) RO: 10/26/2019 REPAIRED FLOORBEAM CAP AT LBL27 FS 621 TO FS559+112 IAW SRM.SDR SWIA2019103046620Floor Support · corrodedRH FLOOR SILL HAS 2 AREAS OF CORROSION BETWEEN FS 559+12 AND FS559+20 (C-CHECK) RO: 10/26/2019 REMOVED CORROSION FROM RH FLOOR SILL BETWEEN FS 559+12 AND FS559+20 IAW REO.SDR SWIA2019103046619Floor Support · corrodedFLOORBEAM CAP AT LBL9 BETWEEN FS618 AND FS 570 HAS MULTIPLE AREAS OF CORROSION (C-CHECK) RO: 10/26/2019 PERFORMED MAJOR REPAIR TO FLOOR BEAM FLANGE BETWEEN F.S 605 F.S 621 IAW REO.SDR SWIA2019103046618Floor Support · corrodedFLOORBEAM CAP AT RBL9 FROM FS409 TO FS409+128 HAS NUMEROUS AREAS OF CORROSION AROUND NUTPLATE HOLES. (C-CHECK) RO: 10/26/2019 REMOVED AND REPLACED FLOORBEAM CAP AT RBL9 FROM FS409 TO FS409+128 WITH A NEW SERVICEABLE FLOORBEAM CAP IAW SRM.SDR SWAA2019102538209Support Plate · corrodedAFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT PLATE HAD AREAS CORRODED BETWEEN BS. 727 TO BS. 767, RBL 23. / R&R SUPPORT PLATE IAW SRM & DWG.SDR SWAA2019102438171Web · corrodedAFT CARGO BAY SUB THRESHOLD WEB HAS AREAS OF CORRODED BETWEEN BS. 807 TO BS. 827, RBL 27. / R&R SUB THRESHOLD WEB PER SRM & DWG.SDR SWAA2019102438170Angle · corrodedAFT CARGO BAY ANGLE UNDER SHIELD CORRODED ON THE FORWARD END BETWEEN BS. 767 TO BS. 787, RBL 23. / R&R ANGLE PER SRM & DWG.SDR SWAA2019102238097Support · corrodedAFT CARGO BAY L/H FLOOR TO SIDEWALL SUPPORT PLATE CORRODED BETWEEN BS. 727 TO BS. 847, LBL 23. / R&R SUPPORT IAW SRM AND DWG.SDR R61A20191022115Shear Panel · corrodedWHILE AC WAS IN FOR HVY CK FOUND CF 3 FLOOR STRUCTURE FR87 RH SHEAR PANEL HAS CORROSION. AAR MX REPLACED CF 3 FLOOR STRUCTURE FR87 RH SHEAR PANEL PN 170-94919-001 IAW SRM 51-42-01, 51-42-02, 51-43-03. SEE AAR NRC #4500474-1000-0048 FOR WORK PERFORMED.SDR ASAA2019102131031Web · corrodedAFT CARGO TORSION BOX UPPER WEB AT FR. 56 HAS CORROSION. GROUNDED - YES. REMOVED AND REPLACED AFT CARGO TORSION BOX WEB IAW A320 SRM 51-42-11 AND AIRBUS DWG 17E53470321.SDR R61A2019101711105Shear Panel · corrodedCORROSION WAS FOUND CF 3 FLOOR STRUCTURE LH SHEAR PANEL AT FR 87. LH SHEAR PANEL WAS REPLACED IAW ETD2019-170-136163 AND SRM 51-42-01.SDR R61A2019101711104Floor Support · corrodedCORROSION WAS FOUND CF 3 FLOOR STRUCTURE RH PANEL SUPPORT BETWEEN FR 88 AND FR 90.PANEL SUPPORT WAS REPLACED IAW SRM 51-42-01.SDR R61A2019101711103Gusset · corrodedCORROSION WAS FOUND CF 3 FLOOR STRUCTURE FRAME 89 O/B GUSSET. GUSSET WAS REPLACED IAW SRM 51-41-02.SDR R61A2019101711097Gusset · corrodedWHILE AC WAS IN FOR HVY CK FOUND CF3 FLOOR STRUCTURE FR 89 LH/IB GUSSET HAS CORROSION. MX REMOVED AND REPLACED CF3 FLOOR STRUCTURE FR 89 LH/IB GUSSET PN 170-60257-001 IAW SRM 51-41-02.SDR SWAA2019101637929Shield · corrodedAFT CARGO BAY SHIELD FORWARD OF THE CARGO DOOR CORRODED BETWEEN BS. 767 TO BS. 787, RBL 23. / R&R SHIELD PER SRM & DWG.SDR SWAA2019101637928Gusset · crackedFORWARD CARGO BAY AFT BULKHEAD GUSSET CRACKED AT BS. 500D, STR. 19R. / R&R GUSSET IAW SRM & DWG.SDR REXA2019101401437Intercostal · corrodedCORROSION ON INTERCOSTALS BTW FS 310 TO FS 319 STRG 20R AT MAIN AVIONICS COMPARTMENT. (E/E)(SM)(TSI 53-20-304).
DUE TO CORROSION LEVEL 2 ON INTERCOSTAL BTW FS310/319 AND STRG 20R AT MAIN AVIONICS COMPARTMENT WAS REPLACED PER CRJ-900 SRM 51-42-13-001-001-A01.SDR REXA2019101401430Floor Support · corrodedCORROSION ON THE FLOOR SUPPORT BS 349 TO 366 BETWEEN RBL 41 TO RBL 46. THE FLOOR SUPPORT WAS REPLACED IAW SRM 51-42-06. AND CRJ-900 SRM 51-42-13.SDR ASAA2019101010965Web · corrodedAFT PIT LOWER MAIN SILL THRESHOLD WEB HAS SEVERAL SPOTS OF CORROSION BETWEEN BS800 - BS840. GROUNDED - YES. REMOVED CORROSION ON AFT PIT LOWER MAIN SILL THRESHOLD WEB, ORIG. 0.045, REMAINING 0.039, REMOVED 0.006 AND FOUND TO BE OUT OF LIMITS PER B737-800 SRM 5SDR SWAA2019100837668Floor Support · crackedFLOOR INTERCOSTAL CRACKED AT BS. 540, LBL 1. REPAIRED INTERCOSTAL PER SRM.SDR AALA2019100879054Intercostal · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED LEFT HAND FORWARD DOOR CUT OUT INTERCOSTAL UPPER INBOARD FASTENER HOLE AT FR 16 AND DOOR STOP #7. REPLACED INTERCOSTAL PER SRM 52-11-31.SDR AALA2019100879053Intercostal · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED LEFT HAND FORWARD DOOR CUT OUT INTERCOSTAL LOWER INBOARD FASENER HOLE AT FR 16 AND DOOR STOP #7. REPLACED INTERCOSTAL PER SRM 52-11-31.SDR AALA2019100759029Angle · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT WET AREA FLOOR "Z" ANGLE BETWEEN BS 992 AND BS 1006 AT RBL 32. REPLACED ANGLE PER SRM 51-40-02.SDR AALA2019100759025Angle · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT WET AREA PRESSURE DECK ANGLE AT BS 992 BETWEEN LBL 27 AND LBL 45. REPLACED ANGLE PER SRM 51-40-02.SDR CALA2019100541687Intercostal · corrodedAFT CARGO PIT FR56-57 INTERCOSTAL ST38R HAS CORROSION PER HAECO LCQ NR LP 9299062 GENERATED BY N078625 REMOVED AND REPLACED INTERCOSTAL IN AFT CARGO COMPARTMENT BTWN F RAME 56 AND 57 AT STGR 38R IAW A320 SRM 51-42-11-801/TO80673599/ 005/2019 #A ECRA5341-01189.SDR CALA2019100501689Floor Support · corrodedCABIN FLOOR SUPPORT ANGLE IS CORRODED AT 947-987 JUST I/B OF R-2 DOOR REF AAR N/R 99847934 REMOVED AND REPLACED AFT CABIN FLOOR SUPPORT ANGLE INNER CHORD REF B737 SRM 41-40-02 ADD EMP:V891438SDR AALA201910049022Web · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON RIGHT HAND FLOOR SUPPORT PANEL SUPPORT WEB ANGLE AT FR 35.4 AND Y-1722. REPLACED WEB PER SRM 51-74-00-801 AND 51-42-11-801.SDR A6WA2019100246900Angle · corrodedANGLE LOCATED AT FS 589 BETWEEN STRINGERS 22R AND 24R CORRODED. REPLACEDSDR KCSA201910011234Support · corrodedFWD CARGO AUX SILL CHORD HAS CORROSION AT STA 610 - 632SDR KCSA201910011233Angle · crackedCRACKED ANGLE JUST I/B OF FWD CARGO DOOR LOWER SILL STA 625 AND 534 RBL 41SDR KCSA201910011232Support · damagedBALLMAT SUPPORT AT FWD CARGO DOOR AT STA 610 DAMAGED