SDR QMLA2019070919057Structure · crackedDURING THE COMPLETION OF AAIP A ZONE 0301 AIRFRAME INSPECTION NOTICED A CRACK ON THE AVIONICS BAY CEILING. REFERENCED MSR AND NOTIFIED TECH REP AND WAS NOTIFIED CRACK COULD BE REPAIRED UNDER SERVICE BULLETIN SB-BK117C2-53-013. THIS AIRCRAFT REMAINS OUT OF SERVSDR R61A201907090690Threshold · corrodedCORROSION FOUND INSIDE AFT. GIRT BAR FITTING CUTOUT WHILE PERFORMING 170EO-53-14-0002 L1 DOOR LOWER BEAM.SDR R61A201907090688Support Fitting · corrodedCORROSION AT FR 16 LAV SUPPORT FITTING.SDR R61A201907090687Shear Panel · corrodedCORROSION AT FR 84-86 RT SHEER PANEL AS MARKED.SDR R61A201907090685Gusset · corrodedCORROSION AT FR 90 INTERCOSTAL GUSSET AS MARKED.SDR R61A201907090684Shear Panel · corrodedCORROSION AT FR. 87-88 LT SHEAR PANEL AS MARKED.SDR R61A201907090683Panel Support · corrodedCORROSION AT FR 88-90 PANEL SUPPORT AS MARKED.SDR R61A201907090682Door Sill · corrodedCORROSION AT LT FR 15-16 OB SILL AS MARKED.SDR R61A201907090681Door Sill · corrodedCORROSION AT SILL FR 12-14 RT AS MARKED.SDR SWAA2022031148360Angle · corrodedFWD CARGO STA 500/500A RBL24 TRANSITION ANGLE HAS CORROSION AROUND NUT PLATE HOLES. / TRANSITION ANGLE STA 500-500A REMOVED AND REPLACED ON NRC # G664780. P/N 143A8126U31.SDR SWAA2022031148359Angle · corrodedFWD CARGO STA 500A/500D LBL24 TRANSITION ANGLE HAS CORROSION AROUND NUT PLATE HOLES. / REMOVED AND INSTALLED REPAIR TRANSITION(SIDEPLATE) ANGLE AT FWD CARGO; STA. 488 TO STA. 500D; LBL 24 IAW SRM 53-00-53-2R-5. SEE TASKS AND WIP'S FOR INDIVIDUAL SIGN OFFS. THESDR MK1Y20190902014Adapter · corrodedCORROSION FOUND ON THE FWD RT SERVICE DOOR ADAPTER ASSY P/N 141T6252-14, STA 347, WL 200.SDR MK1Y20190902007Support Angle · corrodedDURING FWD CARGO DOOR SURROUND STRUCTURE AREA INSPECTION FOUND CORROSION ON UPPER SURFACE OF STA 566 TO STA 599, RBL 42, BALL PANEL ASSY SUPPORT ANGLE P/N 451T1606-30.SDR MK1Y20190902005Stiffener · crackedFOUND CRACK ON STIFFENER AT STA 784, RBL 10.94, WL 196 THE CRACK IS STARTING FROM THE EDGE WITH A LENGTH OF 2.0".SDR MK1Y20190902004Stiffener · crackedFOUND CRACK ON STIFFENER AT STA 784, LBL 10.94, WL 196 THE CRACK IS STARTING FROM THE EDGE WITH A LENGTH OF 2.3".SDR AALA201908169074Intercostal · crackedAIRCRAFT IN BASE VISIT: CRACK INDICATION ON INTERCOSTAL FRAME 16 LH UPPER AND LOWER INBOARD HOLES AT LEVEL DOOR STOP FITTING 7 AT FWD GALLEY AREA (2 EA), (D:0.310"). REPLACED INTERCOSTAL FRAME 16 LH AT LEVEL OF DOOR STOP FITTING #7 IAW A321 SRM 51-72-11 AND DWSDR AALA201908169075Intercostal · crackedAIRCRAFT IN BASE VISIT: CRACK INDICATION ON INTERCOSTAL FRAME 16 RH UPPER AND LOWER INBOARD HOLES AT LEVEL DOOR STOP FITTING 7 AT FWD GALLEY AREA (2 EA), (CRACK D=0.330). REPLACED INTERCOSTAL FRAME 16 RH AT LEVEL OF DOOR STOP FITTING #7 IAW A321 SRM 51-72-11 ASDR AALA201908169076Intercostal · crackedAIRCRAFT IN BASE VISIT: CRACK INDICATION ON INTERCOSTAL FRAME 16 RH LOWER INBOARD HOLE AT LEVEL DOOR STOP 1 AT FWD GALLEY AREA (1 EA), (D=0.265"). REPLACED INTERCOSTAL FRAME 16 RH AT LEVEL DOOR STEP 1 AT FWD GALLEY AREA IAW A321 SRM 51-72-11 AND DWG# D53112300SDR SWAA2019072235154Threshold · corrodedFORWARD CARGO THRESHOLD WEB CORRODED BETWEEN BS. 457 TO BS. 476, RBL 29. R&R WEB PER SRM.SDR SWAA2019071935047Gusset · crackedFORWARD CARGO CORNER GUSSET CRACKED AT BS. 500D, STR. 19L. R&R GUSSET PER SRM.SDR SWAA2019071935045Gusset · crackedFORWARD CARGO CORNER GUSSET CRACKED AT BS. 500D, STR. 19R. R&R GUSSET PER SRM.SDR RAIA2019000708000Angle · crackedCENTER OMEGA BEAM CENTER SPLICE IS CRACKED AT FR 20 TO 22. REMOVED ANGLE AT CENTER OMEGA BEAM SPLICE FR 20 TO 22. INSTALLED ANGLE AT CENTER OMEGA BEAM SPLICE FR 20 TO 22.SDR DALA2019070904167Rivet · missing(AIRCRAFT 5806, L/P 6009894) FOUND MISSING RIVET AT STATION 1580.45 1 INCH RIGHT OF STRINGER S30. REMOVED AFT LAV TANK ACCESS PANEL FOR ACCESS AND FOUND CORROSION AROUND MISSING RIVET LOCATION REF AMM 25-50 659235. REMOVED AFT CARGO FLOOR BOARD FOR ACCESS AT SSDR A6WA2019071246697Fitting · crackedFS484.00, RBL 27, O/B CLIP IS CRACKED. REPLACED CLIP IAW SRM 51-42-21 AND REO 601R-52-41-059 REV-B.SDR V0XR20190705007Channel · crackedAFT CARGO DOOR TRACK STRCTURE LOWER FWD AND AFT BRACKETS CRACKED. CORRECTIVE ACTION: REMOVED AND REPLACED LOWER FWD AND AFT DOOR TRACK STRUCTURE IAW SRM 51-42-13, 51-42-06, 51-42-21 AND 51-40-11.SDR A6WA201946692Fitting · crackedFS484.00, LBL27, O/B CLIP IS CRACKED. REPAIRED CLIP IAW SRM 51-42-21 AND REO 601R-53-41-059 REV-B.SDR AALA20190709001Intercostal · crackedAIRCRAFT IN BASE MAINTENANCE: FORWARD WET AREA FLOOR INTERCOSTAL CRACKED BETWEEN BS 328 AND BS 344 AT LBL 42. REPLACED INTERCOSTAL PER 51-00-05-01.SDR DALA2019070904135Angle · corrodedEXFOLIATION CORROSION AFT OF AFT CARGO COMPT - GANG BOND/GROUND STRIP ANGLE ON STR 34 LT, BETWEEN FRAMES 65, SEE NR FOR ADDITIONAL INFORMATION 001-0057:5340-3001/001 00062 REPLACED GANG GROUND ANGLE REF SRM 51-72-11.SDR WVER2019070837Door Sill · corrodedLT FLOOR SILL AT FS 985.00 IS CORRODED AT SCREW HOLE.SDR EVCA2019070800001Web · crackedVERTICAL TUNNEL RT WEB CRACKED THROUGH RIVET HOLE AT FS STA. 80, WL 66.5.SDR CA191019001Floor Support · corroded(CAN) BETWEEN FS 856 TO FS 977 AT LBL 9, CORROSION FOUND, 100% MATERIAL LOSS NOTED AROUND A FLOORBOARD ATTACHMENT HOLE JUST FORWARD OF THE CROSSBEAM AT FS 939, THE HOLE WAS REAMED TO A .316 TO CLEAN UP THE CORROSION. (TC# 20191019001)SDR COEA2019080172816Floor Support · crackedRT FLOOR SUPPORT CRACKED BETWEEN FRAMES 30-31. REPAIRED IAW E.O. 5315-02.SDR R61A201907070749Door Sill · corroded***AIRCRAFT IN HEAVY CHECK***CORROSION FOUND ON FWD CARGO DOOR CUTOUT LOWER SILL BEAM AT FR 25 AND STR 26R. PERMANENTLY REPAIRED IAW ETD2019-170-097949. ***AIRCRAFT REMAINS IN HEAVY CHECK***SDR REXA2019070701101Intercostal · corrodedINITIAL INSPECTION: CORROSION ON INTERCOSTAL 6 LBT AND 6 RBL BTW FS 364-349 AT INTERNAL STRUCTURE OF MAIN AVIONICS COMPARTMENT (E/E) (SM). IN REFERENCE NRC 00084 TASK 900-53-140-300 APPENDIX A ].(TCI:100-09) SUMMARY OF NRC 00139: CORROSION LEVEL 2. INTERCOSTALSDR AALA20190711007Expansion Joint · crackedAIRCRAFT IN BASE MAINTENANCE: CABIN EXPANSION JOINT CRACKED RIGHT OF CENTERLINE AT BS 520. REPLACED EXPANSION JOINT PER 551-00-05-1.SDR AALA20190711006Expansion Joint · crackedAIRCRAFT IN BASE MAINTENANCE: CABIN EXPANSION JOINT CRACKED LEFT OF CENTERLINE AT BS 520. REPLACED EXPANSION JOINT PER 551-00-05-1.SDR V0XR20190705004Landing · crackedFWD EQUIPMENT COMPARTMENT RT LANDING CRACKED. CORRECTIVE ACTION: REMOVED AND REPLACED RT DOOR LANDING IAW SRM 51-42-06, 51-42-10, 51-40-11, 51-25-04 AND AMM 20-70-00.SDR SWAA2019070934699Stiffener · crackedCENTER WING STIFFENER CRACKED AT 663 BULKHEAD, RBL 25. R&R STIFFENER PER SRM & EA.SDR SWAA2019070934698Stiffener · crackedCENTER WING STIFFENER CRACKED AT 663 BULKHEAD, LBL 25. R&R STIFFENER PER SRM.SDR DALA2019070804123Support · corroded(LOG 1159969) DURING INSPECTION FOUND CORROSION SUPPORT ZEE LOCATED BTW BS727 TO BS767 AT LEVEL STR25R AT AFT CARGO COMPARTMENT. REPLACED SUPPOR ZEE LOCATED BTW BS 727 TO BS 767 AT LEVEL STR 25R AFT CARGO COMPARTMENT ASPER SRM 51-10-02 AND DRAWING #146A7500.SDR UIEA2019070404675Structure · crackedDURING HFEC INSP. CARRIED OUT AND FOUND CRACK INDICATION AT 01EA HOLE AT BS2231 S-16L INNER CHORD AREA AS MARKED(<P>CRACK AREAS TRIMMED OUT & REPAIR CARRIED OUT AS PER SRM 53-60-15-2R-2, REPAIR 2, DETAIL XI, REV.85 & REV.86 AND SASCO EN 274-9, REV.0.</P><P>REPSDR CALA2019070801167Strap · corrodedFWD CARGO STRAP BELOW CLEAT AT FR29 ST41R-40R HAS CORROSION ON REF 9293149 SPEC A3NB-05-3-6013. REMOVED & REPLACED LOWER STRAP BELOW CLEAT AT FR29 ST 41R-40R IAW SRM 51-42-11 PARA E & SRM 51-72-11 PARA 3 & 4 AT ON HANGAR NR 9293149.SDR CALA2019070801162Cleat · corrodedCLEAT AT FR 65 STR 39R HAS CORROSION PER NR LP 9293324 REMOVED AND REPLACED CLEAT AT FR63 STR 39R IAW SRM 51-72-11 -911-001.SDR CALA2019070801161Cleat · corrodedFWD CARGO CLEAT FR30 STR 42R-41R HAS CORROSION ON REF 9293153 SPEC A3NB-05-3-6013. REMOVED & REPLACED FWD CARGO CLEAT AT FR30 STR 42R TO 41R IAW SRM 51-72-11-911-001 AT ON HANGAR NR 9293153.SDR CALA2019070801160Cleat · corrodedFWD CARGO FR32 CLEAT STR 40R-39R HAS CORROSION PER NR LP 9293169 REMOVED AND REPLACED FWD CARGO CLEAT AT FR32 STR 40R TO 39R IAW SRM 51-72-11-911-001.SDR DALA2019070804075Splice · corrodedAWR IN REF MON/9508/049-MON, 95 REP, L.P. 2070042: CORROSION ON PREVIOUS REPAIR SPLICE LOWER AREA OF AFT CARGO COMPARTMENT. LEVEL 2. PREVIOUS REPAIR SPLICE LOWER AREA WERE REPLACED OF AFT CARGO COMPARTMENT PER SRM 53-20-15-2R-7, SRM 51-41-04-0G AND SRM 51-41-0SDR ASOA201907077067Floor Support · crackedPASSENGER CABIN FLOOR SUPPORT BETWEEN FRAMES 23L-24L CRACKED. REMOVED AND REPLACED CABIN FLOOR STEP UP SUPPORT.SDR SWAA2022031147635Support Angle · crackedPOTABLE WATER SERVICE PANEL AFT INTERNAL SUPPORT ANGLE IS CRACKED. / REMOVED AND REPLACED/INSTALLED; POTABLE WATER SERVICE PANEL; AFT INTERNAL SUPPORT ANGLE (STIFFENER) IAW SRM 51-40-02; AND DRAWING #147A7221-0017. 59565U 09JUL19SDR R61A201907060755Service Panel · corrodedDURING HEAVY CHECK MAINTENANCE FOUND WASTE BOX HAS COMPOSITE DELAMINATION AND CORROSION ON INTERNAL SIDE OF BOX; FR 88-89; STR 28R-26R. REMOVED AND REPLACED WASTE BOX REF: SRM 51-40-08. A/C REMAINS IN CHECK.SDR R61A201907060752Angle · corrodedDURING HEAVY CHECK MAINTENANCE FOUND FWD FUSELAGE BETWEEN FR16 AND FR17 IN BETWEEN STRINGER 26R AND 27R 2 EA ANGLES FWD AND AFT OF HEATED DRAIN MAST ARE CORRODED. AFTER CLEANING FWD ANGLE, NO DAMAGE NOTED. REF SRM 51-10-02. REMOVED AND REPLACED AFT ANGLE IN FW
Back to JASC 5320