JASC 5320
Service difficulty reports · 216,415
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR REXA2019061260859Angle · corrodedFUSELAGE , FORWARD WING TO BODY FAIRING MOUNT ANGLE CORRODED RHS. REMOVED AND REPLACED FAIRING MOUNT ANGLE ON FUSELAGE AT FWD WING TO BODY IAW CRJ 200 SRM 51-42-06.SDR IPXA2019061243190Stiffener · crackedINSPECTION TYPE:2C, AFT CARGO STA. 1841 LBL 30 BELOW FLOOR HAS A CRACKED VERTICAL STIFFENER.REMOVED AND REPLACED CRACKED VERTICAL STIFFENER AT STA. 1841 LBL 30 BELOW AFT CARGO FLOOR IAW MD-11 SRM 51-33-01. (MINOR)SDR IPXA2019061243189Stiffener · crackedINSPECTION TYPE:2CAFT CARGO AT STA. 1841 BL 0 BELOW FLOOR HAS A CRACKED VERTICAL STIFFENER.REMOVED AND REPLACED CRACKED VERTICAL STIFFENER AT STA. 1841 BL 0 BELOW AFT CARGO FLOOR IAW MD-11 SRM 51-33-01. (MINOR)SDR IPXA2019061243128Stiffener · crackedINSPECTION TYPE:2C, AFT CARGO AT STA.1841 RBL 30 HAS A CRACKED VERTICAL STIFFENER BELOW FLOOR.REMOVED AND REPLACED CRACKED AFT CARGO VERTICAL STIFFENER AT STA. 1841 RBL 30 BELOW FLOOR IAW MD-11 SRM 51-33-01. (MINOR)SDR IPXA2019061043072Angle · gougedINSPECTION TYPE:2C CENTER CARGO STA. 1781 RT SIDE JUST AFT OF CARGO DOOR AFT JAMB. VERTICAL STANCHION (ANGLE) HAS 2 GOUGES.REMOVED AND REPLACED GOUGED VERTICAL STANCHION (ANGLE) AT CENTER CARGO STA, 1781 R/H SIDE IAW MD-11 SRM 51-35-01. (MINOR)SDR SWAA2019060433247Angle · crackedINTERCOSTAL UPPER ANGLE CRACKED BETWEEN BS. 380 TO BS. 400, BL 0. / R&R ANGLE IAW SRM & DWG.SDR SIMA20190526005Door Sill · corrodedCARGO DOOR SILL CORRODED AT NUT PLATE HOLE. C/A-REMOVED AND REPLACED CARGO DOOR SILL IAW SRM 51-40-02 AND SRM 51-20-03.SDR SIMA20190526004Door Sill · corrodedSERVICE DOOR CENTER SILL CORRODED AROUND SERVAL NUTPLATES. C/A-REMOVED AND REPLACE SERVICEABLE SERVICE DOOR CENTER SILL IAW SRM 51-40-02.SDR RAIA201905260001Structure · corrodedAFT CARGO DOOR CUTOUT AT FR 65 & 68 LATERAL-L SHAPE HAVE CORROSION @ LOWER FWD & AFT CORNERS. R&R AFT FR 65 & 68 LATERAL-L SHAPE AT LOWER FWD & AFT CORNERS.SDR AALA201905299028Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK PLATE FR 56 AT LEVEL STR 36L AFT CARGO COMPARTMENT (1 EA). REPLACED PLATE FR56 AR LEVEL STR 36L IN AFT CARGO COMPARTMENT (1EA)IAW SRM 51-72-11 AND DWG NO.D53974637.SDR SWAA2022030906823Shield · corroded***CORROSION*** FWD. CARGO BAY R/H FLOOR SHIELD AT BS 480- BS 500 HAS AREAS OF CORROSION; WL156; RBL23 / REMOVED AND REPLACED FWD CARGO BAY R/H FLOOR SHIELD AT BS 480-BS500A ITEM 7531855 PO #744712. LOCATED AND DRILLED IAW SRM 51-40-05; DWG 143A0080 AND SRM 51SDR SWAA2022030969868Scuff Plate · crackedAFT CARGO DOOR OPENING CENTER SCUFF PLATE HAS A DENT WITH A CRACK NEXT TO A WELD 26' AFT OF FWD EDGE. / REMOVED/REPLACED AFT CARGO DOOR CENTER SCUFF PLATE AS PER AMM 53-11-02SDR SWAA2022030979561Scuff Plate · crackedAFT CARGO PIT AFT CORNER SCUFF PLATE CRACKED / WORK ACCOMPLISHED ON W/O #39546-1600-0001.SDR CA190527008Door Sill · corroded(CAN) SERVICE DOOR SILL CORRODED AT 3 LOCATIONS. (TC# 20190527008)SDR ASAA2019052529850Shear Plate · corrodedAFT MAIN CABIN LATERAL SHEAR PLATE BETWEEN FRAMES 69 & 70 APPROX: RBL 48 IS CORRODED (FLOOR LEVEL) GROUNDED - YES. REMOVED AND REPLACED LATERAL SHEAR PLATE IAW SRM 51-42-11 & DWG # D53471120. DOT REMOVED (ORIG THK .071, REMAINING 0. CORRODED 100% THRU. 2 " LSDR REXA2019062750974Floor Support · corrodedRIGHT FLOOR SILL HAS CORROSION UNDER AFT END OF SILL, FS 319, RBL 42. REMOVED AND REINSTALLED NEW PLATE ASSY#601R31148-79 TO RBL 42-FS 319 IAW SRM 51-42-21 AND SRM 51-42-06.SDR FDEA2019062051375Channel · corrodedCTR CARGO COMPT BILGE, CORROSION ON BOTTOM SIDE OF CARGO TRACK, STA 1770 L42 L/H. REMOVED AND REPLACED CHANNEL REF DWG NFJ 6010SDR FDEA20190611272Support Angle · corrodedAFT CARGO COMPT STA1841 30RBL HAS CORROSION UNDERSIDE. REMOVED AND REPLACED AGA7170-19 SUPPORT ANGLE PER DWG. AGA7170SDR IPXA2019060742946Floor Support · crackedINSPECTION TYPE:2CCENTER CARGO AT STA. 1741 AND LONG. 41 L/H, FLOOR SUPPORT ANGLE IS CRACKED.REMOVED, FABRICATED AND REPLACED FLOOR SUPPORT ANGLE AT STA. 1741 AND LONG. 41 L/H IAW DWG. ADA0130 AND SRM 51-33-01. (MINOR)SDR IPXA2019060742945Floor Support · crackedINSPECTION TYPE:2CCENTER CARGO AT STA. 1781 AND LONG. 41 L/H, FLOOR SUPPORT ANGLE IS CRACKED.REMOVED, FABRICATED AND REPLACED FLOOR SUPPORT ANGLE AT STA. 1781 AND LONG. 41 L/H IAW DWG. AFA7295 AND SRM 51-33-01. (MINOR)SDR IPXA2019060742944Floor Support · crackedINSPECTION TYPE:2CCENTER CARGO AT STA. 1751 AND LONG. 41 L/H, FLOOR SUPPORT ANGLE IS CRACKED.REMOVED, FABRICATED AND REPLACED FLOOR SUPPORT ANGLE AT STA. 1751 AND LONG. 41 L/H IAW DWG. ADA0130 AND SRM 51-33-01. (MINOR)SDR REXA2019060750803Floor Support · corrodedBEAM AT RBL 9 O/B FLOOR PANEL LANDING HAS CORROSION BETWEEN FS 610 AND FS 621, IN THE CARGO BAY. REMOVED CORROSION BETWEEN FS 610 AND FS 621 IN THE CARGO BAY ON BEAM AT RBL 9 O/B FLOOR PANEL LANDING IAW CRJ 200 SRM 51-21-06 AND INSTALLED REPAIR STRAP IAW CRJ SDR REXA201906030769Floor Support · corrodedAFT CABIN FLOOR SUPPORT STRUCTURE-TIE DOWN BEAM TOP CAP CORRODED FROM STA-559+80 TO STA-574, RIGHT SIDE OUTBOARD BEAM RBL 27.
REMOVED CORROSION BY BLENDOUT AND FOUND TO BE WITHIN LIMITS IAW BOMBARDIER REO 601R-53-00-005 REV: B STA 559+86 (.050" ORIGINAL - .0SDR DALA2019052603288Structure · corroded(AIRCRAFT 6712, L/P 1091702) AWR / CORROSION / STA: 1470 LBL STRINGERS 2.90, 10.45, 16.10/ STA. 1510 RBL STRINGER 2.90 / ON AT AFT CARGO COMPARTMENT FLOOR STRUCTURE. (C2). CORRECTIVE ACTION: SUMMARY: NRC 463 CORROSION LEVEL 2 ;STRINGERS STA 1470 LBL 10.45 AND SDR UIEA2019052804312Floor Support · corrodedCORROSION FOUND ON MAIN CABIN FLOOR SUPPORT FRAME T CAP AT BS 325 RBL 25. (<P>REPAIRED MAIN CABIN FLOOR SUPPORT BEAM AT STA 325 RBL 25 IAW SRM 53-00-51-2R-1.</P>)SDR UIEA2019052804316Fitting · corrodedL-1 PASS DOOR FWD GIRT BAR FTG ON FUSE CORRODED 4 SQ IN. (<P>REMOVED AND REPLACED L-1 PASS DOOR FWD GIRT BAR FITTING IAW SRM 51-40-02. ACCESS GAINED ON TASK NR-00609.</P>)SDR UIEA2019052804318Fitting · corrodedL-1 PASS DOOR AFT GIRT BAR FITTING ON FUSE CORRODED 2 SQ IN AT ATTACH FASTENERS. (<P>REMOVED AND REPLACED L-1 PASS DOOR AFT GIRT BAR FITTING PLATE IAW SRM 51-40-02. ACCESS GAINED ON NR-00609.</P>)SDR UIEA2019052804319Fitting · corrodedL-1 PASS DOOR FWD GIRT BAR FTG ON FUSE ATTACH PLATE BENEATH CORRODED 8 SQ IN. (<P>REMOVED AND REPLACED L1 PASS DOOR FWD GIRT BAR FITTING ATTACH PLATE IAW SRM 51-40-02. ACCESS GAINED ON NR-00609.</P>)SDR DALA2019052503229Support Angle · corroded(LOG 1090376) DURING INSPECTION FOUND CORROSION SUPPORT ZEE ON BS 727 TO BS 847 AND STR 25L AT AFT CARGO COMPARTMENT. REPLACED SUPPORT ZEE BTW BS 727 TO BS 847, STRINGER 25L AT AFT CARGO COMPARTMENT ASPER SRM 51-10-02 ITEM 9, SRM 51-40-02 AND DRAWING #146A7502SDR SWAA2022030972248Panel · elongatedL/H PACK AIR EXHAUST PANEL; 2EA DAMAGED OUT OF ROUND HOLES. / AFTER EVALUATION OF DAMAGE ON THE L/H PACK AIR EXHAUST PANEL FOUND TO BE OUT OF ALLOWABLE LIMITS IAW AMM 21-51-24-340-803 PARA. 4.A. REMOVED DAMAGE; FABRICATED; INSTALLED AND CURED REPAIR PLIES ON TSDR CA190528006Floor Support · corroded(CAN) LIGHT CORROSION ON THE LEFT HAND SIDE OF THE AIRCRAFT BETWEEN F.S 728 TO F.S 827 ON THE PRESSURE DECK FLOOR (TC# 20190528006)SDR SWIA2019092746353Angle · crackedLEFT HAND BATT RIB ANGLE CRACKED. (C-CHECK) RO: 09/26/2019 REMOVED AND REPLACED LH BATT RIB ANGLE IAW SRM.SDR SWAA2019062534043Support · corrodedFORWARD CARGO BAY FLOOR TO SIDEWALL SUPPORT CORRODED BETWEEN BS. 500C TO BS. 500D, LBL 25. / REPAIRED SUPPORT PER SRM & DWG.SDR SWAA2019061833849Support · corrodedFORWARD CARGO BAY FLOOR TO SIDEWALL SUPPORT CORRODED BETWEEN BS. 500B TO BS. 500D, RBL 25. / R&R SUPPORT IAW SRM AND DWG.SDR SWAA2019061833806Rivet · shearedFORWARD CARGO BAY BULKHEAD SUPPORT ANGLE HAD SHEARED RIVET AT BS. 500D, STR. 19L. / R&R RIVET PER DWG AND SRM.SDR SWAA2019061833805Rivet · shearedBULKHEAD SUPPORT ANGLE HAD SHEARED RIVET AT BS. 500D, STR. 19R. / R&R RIVET PER DWG AND SRM.SDR SWAA2019061833804Support Angle · corrodedFORWARD CARGO BAY AFT LOWER BULKHEAD SUPPORT ANGLE CORRODED AT BS. 500D, BETWEEN LBL 19 TO RBL 20. R&R SUPPORT ANGLE PER SRM & DWG.SDR SWAA2019061833803Shield · corrodedFORWARD CARGO BAY ON FORWARD SHIELD CORRODED BETWEEN BS. 420 TO BS. 440, RBL 25. / R&R SHIELD PER SRM & DWG.SDR SWAA2019061833802Shield · corrodedFORWARD CARGO BAY AFT SHIELD CORRODED BETWEEN BS. 500 TO BS. 500A, RBL 25. / R&R SHIELD PER SRM AND DWG.SDR SWAA2019061833801Attach Angle · crackedFORWARD CARGO BAY INTERCOSTAL ATTACH ANGLE CRACKED AT BS. 400, LBL 25. / R&R ANGLE IAW SRM AND DWG.SDR SWAA2019061833800Floor Support · crackedFLOOR SUPPORT ANGLE CRACKED BETWEEN BS. 380 TO BS. 400, LBL 13. / R&R ANGLE PER SRM AND DWG.SDR SWAA2019061733752Gusset · crackedFORWARD CARGO BAY GUSSET CRACKED AT BS. 500D, STR. 19R. R&R GUSSET PER SRM AND DWG.SDR SWAA2019061733724Gusset · crackedFORWARD CARGO BAY GUSSET CRACKED AT BS. 500D, STR. 19L. R&R GUSSET PER SRM AND DWG.SDR REXA2019061340817Intercostal · crackedINTERCOSTAL JUST AFT OF EXTERNAL POWER PLUG APPEARS TO BE CRACKED AT TOOLING HOLE, LOCATED JUST I/B AND AFT OF ACCESS DOOR 122BR OPENING. - EDGE BLENDED CRACKED AREA IN AFT INTERCOSTAL AT POWER PLUG IAW CRJ 200 SRM T.R 51-44 FOUND TO BE WITHIN LIMITS IAW CRJ 2SDR REXA2019061240858Floor Support · corrodedLBL 27 I/B AND O/B FLOOR PANEL LANDINGS HAVE CORROSION SPOTS BETWEEN FS 610 THRU FS 621, IN THE CARGO BAY. REPAIRED LBL 27 INBOARD AND OUTBOARD FLOOR PANEL LANDINGS IAW ENDEAVOR E.A NO# CRJ 253-09044 AAR SM 107SDR R61A201906110594Floor Support · corrodedCORROSION-AFT WET AREA FR.88 L.HAND FLOOR SILL HAS CORROSION. REMOVED AND REPLACED AFT WET AREA L.HAND SILL AT FR. 88 EMB 175 SRM 51-40-08,SRM 51-42-01, SRM 51-43-03 SEE EAMS W/O H6837 SN 303 FOR WORK DETAILS. AIRCRAFT REMAINS IN HEAVY CHECK BNA.SDR R61A201906110590Shear Panel · corrodedCORROSION_AFT WET AREA FR.87 CENTER SHEAR PANEL HAS MULTIPLE AREAS OF CORROSION. REMOVED AND REPLACED CENTER SHEAR PANEL AT FR. 87 REF EMB 175 SRM 51-40-08 AND SRM 51-23-06. SEE EAMS W/O H6837 SN 296 FOR WORK DETAILS. AIRCRAFT REMAINS IN HEAVY CHECK BNA.SDR R61A201906110589Shear Panel · corrodedCORROSION-AFT WET AREA FR.87 R.HAND SHEAR PANEL HAS MULTIPLE AREAS OF CORROSION AS MARKED, REMOVED AND REPLACED AFT WET AREA FR.87 SHEAR PANEL REF. EMB 175 SRM 51-40-08, SRM 51-23-04. SEE EAMS W/O H6837 SN 294 FOR WORK DETAILS. AIRCRAFT REMAINS IN HEAVY CHECSDR IPXA2019060542861Web · crackedINSPECTION TYPE:2CL-3 DOOR JAMB LOWER AFT WEB IS CRACKED AT STA. 1307 AND Z=-18.REPAIRED CRACKED L-3 DOOR JAMB LOWER AFT WEB AT STA. 1307 AND Z=-18 IAW SRM 53-40-15 REPAIR 3 FIG. 201. (MAJOR)SDR REXA2019060424798Stiffener · corroded"AWR; HIDDEN CRACK: [ DURING 280 RH FLOOR BEAM REMOTION RELATED WITH NR
C 00141, A STIFFENER OF COCKPIT BULKHEAD, FWD FACE WAS FOUND CRAKED ]:
CRACKED STIFFENER IN STA. FS= 280 AND 26RBL AND WL= 70 AT PAX CABIN F
WD WET AREA. (W1) (CPAX)