JASC 5320
Service difficulty reports · 216,415
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2019051803119Stiffener · crackedMFEC INSPECTION FOUND 01EA CRACK APPROX.0.90" IN LENGTH ON LH NOSE WHEEL WELL VERTICAL STIFFENER FROM WL159.00 TO WL185.00. REPAIRED (LP 1078571)SDR DALA2019051803118Stiffener · crackedMFEC INSPECTION FOUND 01EA CRACK APPROX 0.250" IN LENGTH ON RT NOSE WHEEL WELL VERTICAL STIFFENER FROM WL159.00 TO WL185.00. REPAIRED (LP 1078566)SDR SWAA2019052032874Intercostal · crackedINTERCOSTAL CRACKED AT BS. 540, BETWEEN LBL 45 AND CREASE BEAM. R&R INTERCOSTAL PER SRM.SDR A6WA2019052046609Fitting · crackedRT F.S.484 CLIP IS CRACKED AT RBL27.SDR SWAA2019061833846Web · corrodedAFT CARGO SUB THRESHOLD WEB CORRODED BETWEEN BS. 807 TO BS. 837, RBL 8. / R&R WEB PER DWG & SRM.SDR REXA2019061760880Angle · corrodedCORROSION ON MID CAP ANGLE AT PASSENGER DOOR SURROUND STRUCTURE LOWER SILL.(SM)(CPAX)(53-20-319). "MID CAP ANGLE AT PASSENGER DOOR SURROUND STRUCTURE LOWER SILL WAS REPLACED FOR A NEW ONE (P/N: SH670-31825-9) PER CRJ-900 SRM 51-41-02-001-001-A01.SDR REXA201906176878Angle · corroded"INITIAL INSPECTION. CORROSION ON ANGLES (4EAS) AT SERVICE DOOR SORROUND STRUCTURE LOWER SILL (ON FITTINGS OF PROTECTOR PLATE). (SM)(CPAX)(TCI53-20-320)
"ANGLES (4EAS) AT SERVICE DOOR SORROUND STRUCTUSDR REXA2019061260855Angle · crackedANGLE AT STA. 473.15 LH FUSELAGE SUPPORT BEAM ABOVE CTR WING IS CRACKED. REPLACED ANGLE @ STA 473.15 L/H FUSELAGE ABOVE CTR WING IAW CRJ 200 SRM 51-42-06 AND 51-42-21 AAR SM 33SDR REXA2019061260854Angle · crackedANGLE AT STA. 461.00 RH FUSELAGE SUPPORT BEAM ABOVE CTR WING IS CRACKED. ANGLE @ STA 461.00 R/H FUSELAGE ABOVE CTR WING WAS REPLACED IAW CRJ 200 SRM 51-42-06 AAR SM 33SDR REXA2019061260853Angle · crackedANGLE AT STA. 449.85 RH FUSELAGE SUPPORT BEAM ABOVE CTR WING IS CRACKED
REPLACED ANGLE @ STA 449.85 R/H FUSELAGE ABOVE CTR WING IAW CRJ 200 SRM 51-42-06 AAR SM 33SDR REXA2019061260852Angle · crackedANGLE AT STA. 449.85 LH FUSELAGE SUPPORT BEAM ABOVE CTR WING IS CRACKED
REPLACED ANGLE @ STA 449.85 L/H FUSELAGE ABOVE CTR WING IAW CRJ 200 SRM 51-42-06 AAR SM 33SDR REXA2019061260851Angle · crackedANGLE AT STA.473.15 RH FUSELAGE SUPPORT BEAM ABOVE CTR WING IS CRACKED
REPLACED ANGLE @ STA 473.15 R/H FUSELAGE ABOVE CTR WING IAW CRJ 200 SRM 51-42-06 51-42-21 AAR SM 107SDR SWAA2019060433246Gusset · crackedFORWARD CARGO GUSSET CRACKED AT BS. 500D, STR. 19R. / R&R GUSSET IAW SRM & DWG.SDR SIMA2019060416006Bracket · crackedFWD TORSION BAR BRACKET AT FRAME 61 FOR CARGO DOOR HAS A 1/8" CRACK. -C/A-REMOVED AND REPLACED FWD TORSION BAR BRACKET AT FRAME 61 IAW SRM 51-40-02.SDR SIMA2019060416007Channel · crackedR/H HAT BEAM SUPPORT IS CRACKED BETWEEN FRS 47 AND 48. -C/A-INSTALLED NEW R/H SUPPORT IAW SRM 51-40-02.SDR AALA201906031003Floor Support · corrodedAIRCRAFT IN BASE VISIT: AFT CARGO FLOOR SUPPORT RBL 14, STA 787 AND 807 HAVE CORROSION. INSTALLED AFT CARGO FLOOR SUPPORT STA. 760-887 RBL14 IAW SRM 51-70-12.SDR AALA201906031006Floor Support · corrodedAIRCRAFT IN BASE VISIT: R/H TRANSITION ANGLE FLOOR SUPPORT, STA 847 & 850 HAS CORROSION. INSTALLED NEW TRANSITION ANGLE FROM STA 847 TO 867 IAW AARD 51-00-05-1 AND BOEING DRAWING 146A0081.SDR SWAA2019053133218Structure · corrodedR1 DOOR STRAP, INNER CHORD CORRODED BETWEEN BS. 277 TO BS. 296, RBL 59. R&R INNER CHORD IAW SRM & DWG.SDR SWAA2019053133217Structure · corrodedR2 DOOR INNER CHORD CORRODED BETWEEN BS. 967 TO BS. 982, RBL 52. R&R INNER CHORD IAW SRM & DWG.SDR SWAA2019053133205Baffle · corrodedFORWARD CARGO COMPARTMENT INTERCOSTAL BAFFLE CORRODED AROUND FASTENER HOLES BETWEEN BS. 500 TO BS. 500A, LBL 21. R&R INTERCOSTAL (BAFFLE) IAW SRM & DWG.SDR AALA201905289024Beam · corrodedAIRCRAFT IN BASE VISIT: AFT CABIN AT AFT SERVICE DOOR LOWER BEAM HAS CORROSION SEVERAL AREAS CORROSION (1) 3.5"X.95"X.030" (2) 2.2" X.9"X.042" (3) 3.4"X1.6"X.050". REMOVED CORROSION FROM AFT CABIN AT AFT SERVICE DOOR LWR BEAM (1) 3.5"X.95"X.030" (2) 2.2"X.9"X.SDR SWAA2019052833107Door Sill · corrodedR2 DOOR MOP SILL UPPER FLANGE OF INNER CHORD CORRODED AT BS. 980, WL 208. R&R MOP SILL IAW SRM AND DWG.SDR JJBA20190516008Threshold · corrodedBAGGAGE DOOR THRESHOLD CORRODED FR 65-68. REMOVED AND REPLACED BAGGAGE DOOR THRESHOLD BEAM BETWEEN FR 65-68.SDR AALA20190517003Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CARGO COMPARTMENT LEFT HAND TRANSITION PANEL BETWEEN BS 480 AND 500I. REPLACED TRANSITION PANEL PER SRM 53-00-53-2R-5.SDR AALA20190517002Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CARGO COMPARTMENT RIGHT HAND TRANSITION PANEL BETWEEN BS 500A AND 500I. REPLACED TRANSITION PANEL PER SRM 53-00-53-2R-5.SDR FDEA201905161102Support Angle · corrodedMDIS 643 53-30 1587 16MAY19 MEM FACT U CENTER CARGO. DURING OPEN UPFOR BULGED SKIN ON FUSELAGE, FOUND BULKHEAD CORRODED ON THE FWD AND AFT SIDES, UNDER FLOOR, WHERE DRAIN TROUGH IS MOUNTED AT FWD END. (TRANSFERRED FROM B CHECK NR 27) SHGN 17MAY19 0SDR AALA201905179032Shear Web · crackedAIRCRAFT IN BASE MAINTENANCE: MAIN CABIN RIGHT LATERAL SEAT TRACK SUPPORT SHEAR WEB CRACKED BETWEEN FR 19 AND FR 20. REPLACED SHEAR WEB PER SRM 51-40-08.SDR AALA20190516006Intercostal · crackedAIRCRAFT IN BASE MAINTENANCE: CABIN FLOOR INTERCOSTAL CRACKED BETWEEN BS 328 AND BS 344 AT LBL 45. REPLACED INTEROSTAL PER SRM 51-40-02.SDR AALA20190516005Intercostal · crackedAIRCRAFT IN BASE MAINTENANCE: CABIN FLOOR INTERCOSTAL CRACKED BETWEEN BS 312 AND BS 328 AT LBL 45. REPLACED INTEROCTAL PER SRM 51-40-02.SDR AALA20190516004Intercostal · crackedAIRCRAFT IN BASE MAINTENANCE: FORWARD WET AREA FLOOR INTERCOSTAL UPPER FLANGE CRACKED AT BS 353 AND LBL 13. REPLACED INTERCOSTAL PER 51-00-51-1.SDR CALA2019051700779Cleat · corrodedFWD CARGO PIT CLEAT HAS CORROSION FR33 ST 41R-42R FCD 5300-01440 NR 9299160 REMOVED AND REPLACED CLEAT IN THE FWD CARGO COMPARTMENT AT FR33 AND STR 41R-42R IAW SRM 51-42-11-001.SDR DALA2019051703058Plate · corroded(AIRCRAFT 683, L/P 1078014) OUT OF LIMITS: CORROSION ON RT SIDE PLATE BTW STA 1270 TO STA 1310 AT AFT CARGO COMPARTMENT (IN REF NRC: 0220) (AMDS: 2020-2379). (CCT). SUMMARY OF NRC 00575: SIDE PLATE WAS REPAIRED PER SRM 53-00-53 REP. 2.SDR DALA2019051703057Intercostal · corroded(AIRCRAFT 683, L/P 1077765) INITIAL INSPECTION: CORROSION ON INTERCOSTAL BETWEEN STA 740 AND 760 AND STRINGERS 28 AND 29R. FWD CARGO COMP. (CCD). SUMMARY: OF NRC 00158 (CORROSION LEVEL 2) INTERCOSTAL AT STA 740 TO 760 BTW STRINGERS 28R TO 29R WAS REPLACED PER SDR DALA2019051603056Door Sill · corroded(AIRCRAFT 682, L/P 1076969) CORROSION LOWER UPPER SURFACES ON AFT CARGO DOOR JAMB LOWER SILL AT AFT CARGO COMPARTMENT (CCT) (AMDS 2020-2444). SILL (SIDE PANEL) AT AFT CARGO COMPARTMENT IT IS REPLACED BY AREA OUT OF LIMITS PER SRM 51-40-02 PAR .5 AND 7 D.SDR VNAA2019051699902Stiffener · crackedDURING INSTALLATION OF THE RT FS280.00 BEAM, FOUND THE STIFFENER ON THE FWD SIDE OF THE FS280.00 AT RBL26.00 TO BE CRACKED AT THE LOWER END, REQUIRES REPLACEMENT. C/A: LOCATED, AND DRILLED NEW STIFFENER PART CC670-34117-2 IAW SRM 51-40-11-001-001-A01.SDR A6WA2019051646606Post · crackedFOUND INDICATIONS AT FS409+128 BL 0 LT AND RT POSTS AFT FLANGE RADIUS APPROX. .500" LONG 100% FSH BOTH FAILS NDT.SDR A6WA2019051646605Angle · crackedFOUND INDICATIONS AT FS 409+128 B.L.0.00 LT AND RT POSTS AFT FLANGE RADIUS APPROX. .500" LONG 100% FSH BOTH FAIL NDT.SDR SWAA2022030948164Tie Down · crackedFWD CARGO BAY TIE DOWN PLATE RBL21 AFT OF CARGO DOOR IS CRACKED / RECEIVED NEW FCB TIEDOWN PLATE PER AFT OF THE CARGO DOOR ON PO# 744724 NEW PART WILL BE INSTALLED ON CUST CARD #753-140-00-01YSDR SWAA2022030948166Baffle · crackedFORWARD CARGO BAY FLOOR TO SIDEWALL BAFFLE CLIP IS CRACKED ON THE AFT SIDE OF BS 500C LBL25 / REMOVED FCB FLOOR TO SIDEWALL SUPPORT BAFFLE CLIP; BS 500C; LBL;25 AFT SIDE. LOCATED DRILLED DEBURRED; NEW CLIP; ACC IAW SRM 51-40-02-OG-E; SRM 51-40-05-0G-O. INSP 86SDR SWAA2022030981677Support Fitting · corroded***CORROSION*** ON GRAY WATER DRAIN DOUBLER IN AREA AFT OF ACB STA 986+7 LBL 19 WL 183 / REMOVED & REPLACED GRAY WATER DRAIN SUPPORT FITTING IN AFT OF ACB STA 986+7 LBL 19 WL183 IAW SRM 51-40-02-0G-0SDR SWAA2022030981674Support Bracket · corroded***CORROSION*** ON WATER TANK DRAIN VALVE SUPPORT BRACKET LOCATED AT 947+1 WL 177 BL 0 / REMOVED AND REPLACED DRAIN VALVE SUPPORT BRACKET PN HFAB53-BR-01 AT STA 947+1 WL 177 BL0 IAW DWG 147A9100; SRM 51-40-02SDR SWAA2022030905189Intercostal · elongatedAFT CARGO BAY INTERCOSTAL CLIP HAS ELONGATED HOLES BS747; RBL21; WL156. / REMOVED AND LOCATED AND DRILLED NEW INTERCOSTAL CLIP RECIEVED ON P.O.#707449 12 PER DWG 146A7500; AND SRM 51-40-05-0G-0 OK TO INSTALL 87713U 15MAY19 1035C 15MAY19 INSP 317 15MAY19 SEALEDSDR CA190531002Floor Support · corroded(CAN) DURING SCHEDULED MAINTENANCE A CARGO FLOOR STRUCTURAL I-BEAM ON THE LH SIDE, AT FS1000-FS1031 WAS FOUND TO HAVE LEVEL TWO CORROSION, WITH A HOLE CORRODED COMPLETELY THROUGH THE BEAM AT ONE LOCATION. THE BEAM SECTION TO BE REPLACED IAW APPROVED REPAIR DATSDR SWIA2019070346031Cap · corrodedCROSS BEAM CAP AT FS 589.00 BETWEEN LBL 9 AND LBL 27 CORRODED. (C-CHECK) RO: 07/02/2019 REPLACED OUT OF LIMITS CAP STRIP WITH NEW P/N: 601R35031-165 IAW SRM.SDR SWAA2019061833895Angle · corrodedFORWARD CARGO COMPARTMENT L/H FLOOR TO SIDEWALL ZEE CHANNEL CORRODED ON FASTENER HOLES BETWEEN BS. 460 TO BS. 500D, LBL 21. R&R Z ANGLE IAW SRM & DWG.SDR SWAA2019061833845Web · corrodedEQUIPMENT AND ELECTRONIC BAY INTERCOSTAL CORRODED BETWEEN BS. 354 TO BS. 360, LBL 7. / R&R WEB IAW SRM AND DWG.SDR SWAA2019061833844Web · corrodedAFT CARGO BAY VERTICAL WEB CORRODED BETWEEN BS. 847 TO BS. 855, RBL 21. REPAIRED WEB PER SRM & DWG.SDR SWAA2019061833843Floor Support · corrodedFORWARD CARGO BAY INTERCOSTAL CORRODED BETWEEN BS. 500C TO BS. 500D, RBL 24. R&R INTERCOSTAL IAW SRM & DWG.SDR REXA201906175877Door Sill · corrodedINITIAL INSPECTION: CORROSION ON LOWER SILL AT GALLEY SERVICE DOOR FS=319.70 TO FS=349 (CPAX)
SUMMARY OF NRC S/N 00176: LOWER SILL WAS REPLACED PER CRJ-900 SRM 51-42-06-001-001-A01 AND SRM 51-42-21-001-001-A01.SDR SWAA2019061433731Support · corrodedAFT CARGO BAY FLOOR TO SIDEWALL SUPPORT CORRODED BETWEEN BS. 867 TO BS. 887, RBL 22. / R&R SUPPORT PER SRM & DWG.
Back to JASC 5320