SDR FDEA201905051004Support Channel · crackedWHILE TROUBLESHOOTING THE FWD CARGO LOAD SHUTTLE BEAM PROBLEM, DISCOVERED A CRACK 13" LONG IN LATERAL FLOORBEAM WEB WHERE PDU ACTUATOR MOTOR SUPPORT CHANNEL ATTACHES. ALSO BOTH LEFT AND RIGHT PDU SUPPORT CHANNEL SIDES ARE BROKEN COMPLETELY REPAIRED FLOORBEAM PSDR SWAA2019052933028Scuff Plate · crackedAFT CARGO DOOR AFT CORNER SCUFF PLATE CRACKED IN UPPER SURFACE APPROX. 1" AND LOWER SURFACE APPROX. 1.5". REPAIRED SCUFF PLATE PER EA.SDR REXA2019050500632Intercostal · corrodedINITIAL INSPECTION: CORROSION ON INTERCOSTAL 6 LBL / 6RBL 2LBL AND 2RBL BTW FS 364 TO 349. AT E/E COMPARTMENT.(TCI:53-20-313).
CORROSION LEVEL 2: DUE TO SEVERE DAMAGE INTERCOSTAL 6 LBL / 6RBL 2LBL AND 2RBL BTW FS 364 TO 349. AT E/E COMPARTMENT WERE REPLACED PSDR CALA2019051300769Shear Plate · not reportedRT AFT SHEAR PLATE @FR 68-69 A3NB-53-3-6222 PER NR 92 90327 REMOVED AND REPLACED SHEAR PLATE @FR 68-69 IAW A320 51-42-11 PER NR 9290327 WORK ACCOMPLISHED.SDR SWIA2019050845842Intercostal · corrodedCORROSION ON RT LATCH PIN INTERCOSTAL @ STR 27 BETWEEN FS 349 - FS 364. (C-CHECK) RO: 05/07/2019 REMOVED & INSTALLED NEW SERVICEABLE LATCH PIN INTERCOSTAL STR 27R BETWEEN FS349.00-FS364.00 IAW SRM. LEAK CHECK GOOD.SDR SWIA2019050845837Intercostal · corrodedCORROSION ON LT LATCH PIN INTERCOSTAL @ STR 27, BETWEEN FS 349 - FS 364. (C-CHECK) RO: 05/07/2019 REMOVED AND INSTALLED NEW SERVICEABLE LATCH PIN INTERCOSTAL STR 27L BETWEEN FS349.00-FS364.00 IAW SRM. LEAK CHECK GOOD.SDR DALA2019050502876Support · corroded(LOG 1060380) DURING INSPECTION FOUND CORROSION CHANNEL SUPPORT Z LOCATED BETWEEN BS500A TO BS500I AND STR26R AT FWD CARGO COMPARTMENT. REPLACED CHANNEL SUPPORT Z LOCATED BETWEEN BS500A TO BS600I AND STR 26R AT FWD CARGO COMPARTMENT AS PER SRM 51-10-02 AND DWGSDR DALA2019050502875Intercostal · corroded(LOG 1060371) DURING INSPECTION FOUND CORROSION WEB - INTERCOSTAL LOCATED BETWEEN BS492 TO BS500A AT LEVEL STR 26R AT FWD CARGO COMPARTMENT. REPLACED WEB INTERCOSTAL LOCATED BTW BS492 TO BS 500A AT LEVEL STR 26R FWD CARGO COMPARTMENT AS PER SRM 51-10-02 AND DWSDR CALA2019050700706Door Sill · corrodedEVIDENCE OF CORROSION L-2 DOOR SILL I/B OF AFT GIRT PLATE A3NB-5 3-3-6222 PER NR 9290355. REPAIRED AREA ON L2 DOOR SILL I/B OF AFT GIRT PLATE IAW SRM 51-42-11 AND 53-41-14-300-001 THIS IS A CATEGORY A REPAIR NO REINSPECT REQUIRED PER NR 9290355.SDR CALA2019050700702Pressure Panel · crackedLT BETWEEN FR35 & 36 HAS 60 HOLES. HOLE NUMBER 16 IS CRACKED IN THE 7 ''CLOCK POSITION. ALL OTHER HOLES I/B OF CUT OUT HAVE NO REJECTABLE INDICATIONS. HOLES O/B & ALL HOLES IN CROSSBEAM ATTACHMENT HAVE OUT OF ROUND/REJECTABLE DAMAGE. REPAIR REQUIRED PRIOR TO NSDR CALA2019050700701Door Sill · corrodedEVIDENCE OF CORROSION AT FWD AND AFT I/B SIDE OF R-2 DOOR SILL A 3NB-53-3-6222 PER NR 9290351. REMOVED AND REPLACED R2 DOOR SILL IAW SRM 51-72-11-911-001 PER NR 9290351.SDR CALA2019050700700Angle · corrodedB757-49-3-8083 CORROSION BETWEEN APU AIR INLET DOOR HOUSING AND FUSELAGE SKIN CUTOUT. REF N/R 0058236 CORROSION REMOVAL OF FWD STRAP STA 1787.45 S3R TO S6R L=9.0, W=1 .0,D=.250, UPPER ANGLE STA 1790-1800 S3R L=10.0, W=1.0, D=.063, AND LWR ANGLE STA 1790-1820 SSDR AALA20190505002Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CARGO COMPARTMENT LEFT HAND TRANSITION PANEL BETWEEN BS 727A AND BS 847. REPLACED TRANSITION PANEL PER SRM 53-00-53-2R AND 51-00-05-1.SDR AALA20190505001Shield · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CARGO COMPARTMENT RIGHT HAND TRANSITION SHIELD BETWEEN BS 500 AND BS 500A, REPLACED SHIELD PER 51-00-05 AND SRM 51-40-02.SDR WVER2019050512Intercostal · corrodedLT AND RT STRINGER 27 INTERCOSTALS ARE CORRODED BETWEEN FS 349.00 AND 364.00.SDR SWAA2022030904315Support Bracket · corrodedE & E COMPARTMENT STA 380 STR 23L; P91 SUPPORT BRACKET IS CORRODED. / REMOVED CORRODED SUPPORT ANGLE AND REPLACED WITH NREW SUPPORT ANGLE P/N 143A9173-25 IAW B737-700 SRM 51-40-02-0G-0 AND BOEING DWG 143A9173 LEV.-SDR SWIA2019061445986Intercostal · corrodedINTERCOSTAL CORRODED AT STGR 27L BETWEEN FS 349 AND FS 364. REMOVED AND REPLACED INTERCOSTAL IAW SRM.SDR SWIA2019061445985Support Angle · corrodedSERVICE DOOR LOWER SEAL SUPPORT ANGLE IS CORRODED. (C-CHECK) RO: 06/14/2019 REPAIRED SERVICE DOOR IAW REO.SDR SWAA2019061233577Floor Support · crackedFORWARD CABIN FLOOR SUPPORT INTERCOSTAL CRACKED BETWEEN BS. 312 TO BS. 328, RBL 32. / R&R INTERCOSTAL IAW SRM AND DWG.SDR WVER20190604009Floor Support · corrodedR/H CABIN FLOOR BEAM UPPER SURFACE HAS MINOR CORROSION, RBL 9 F.S. 597, 621, & 637SDR SWAA2019060433269Floor Support · crackedFORWARD CABIN UNDER FLOOR PANEL INTERCOSTAL SUPPORT CRACKED BETWEEN BS. 277 TO BS. 294.5, BL 0. / R&R SUPPORT IAW SRM AND DWG.SDR SWAA2019052432996Scuff Plate · crackedFORWARD CARGO DOOR AFT CORNER SCUFF PLATE CRACKED. REPAIRED SCUFF PLATE IAW EA.SDR WVER2019050418Structure · corrodedFS280.0 CIRCUMFRENCIAL JOINT CORRODED BETWEEN STRINGER 25R AND 26L.SDR SWAA2019051532687Intercostal · crackedFORWARD CABIN FLOOR SUPPORT INTERCOSTAL CRACKED BETWEEN BS. 344 TO BS. 360, BL 0. R&R INTERCOSTAL PER SRM & DWG.SDR REXA2019050400622Doubler · corrodedINITIAL INSPECTION: CORROSION ON INTERNAL DOUBLER IN STA. FS= 295 TO FS= 310 BETWEEN STR 26L TO 26R AT MAIN AVIONICS COMPARTMENT. (E/E)(TCI:53-20-304). INTERNAL DOUBLER IN STA. FS= 295 TO FS= 310 BETWEEN STR 26L TO 26R WAS REPLACED PER SRM 51-42-06-001-001-A01SDR SWAA2019050832456Intercostal · crackedEQUIPMENT AND ELECTRONIC COMPARTMENT CABIN FLOOR SUPPORT INTERCOSTAL CRACKED BETWEEN BS. 312 TO BS. 328, LBL 47. R&R INTERCOSTAL IAW SRM AND DWG.SDR CALA2019050700698Support Fitting · corrodedSUBTASK ZONE 200 OPEN, LAV A SUPPORT FITTING AT STA 340 B/L 0 IS CORRODED. REF N/R 0053993 REMOVED AND REPLACED NEW FITTING P/N 65N57839U2, BATCH 000347007 6, PO NO:SAG7990580 AT MAIN CABIN FWD LAVATORY FLOOR AT STA 340, PER SRM 51-40-02. WORK WAS ACCOMPLISHEDSDR CALA2019050700697Fitting · corrodedSECONDARY FINDING ZONE 200 OPEN, FWD GALLEY FLOOR FITTING AT STA 365 IS CORRODED AND PITTED. REF N/R 0053994 REMOVED AND REPLACED NEW FITTING P/N 415N4007-11, BATCH 00034697 25, PO NO:SAG1900502 AT MAIN CABIN FWD GALLEY FLOOR AT STA 365 PER SRM 51-40-02 AND AMSDR CALA2019050700696Crossbeam · corrodedSECONDARY FINDING ZONE 200 OPEN, FLOOR CROSSBEAM AT STA 395 HAS SEVERAL AREAS OF CORROSION, 22-87. REF NR 0053995. REMOVED DAMAGED CROSSBEAM IAW SRM 51-40-02, FABRICATED NEW SUPPORT FLOOR CROSSBEAM IAW DWG 141N5162, INSTALLED NEW SUPPORT CROSSBEAM, P/N 141N516SDR WVER2019050401Intercostal · corroded2 EACH INTERCOSTALS, FS 349.00 - FS 364.00, STGR27L + STGR27R, FWD OF AVIONICS BAY DOOR, CORRODED BEYOND REPAIRABLE LIMITS. REPLACED BOTH INTERCOSTALS WITH NEW SERVICEABLE INTERCOSTALS IAW APPLICABLE SRM'S.SDR SWAA2022030804878Door Frame · brokenEXTERNAL POWER ACCESS PANEL MISSING BROKEN PIECE OF ALUMINUM ON LEFT SIDE OF FRAME (NOW HINGE SIDE). / REPAIRE EXTERNAL POWER RECEPTACLE PER SRM 53-10-15-2R-4 REPAIR4 CL DMA 0046082 CL# 58427 REPAIRED EXTERNAL POWER RECEPTACLE PER SRM 53-10-15-2R-4 REPAIR 4SDR SWAA2022030846788Stiffener · crackedBS 663 LOWER VAPOR BARRIER LBL 25 WL 148 STIFFENER CRACKED / REMOVED DAMAGED STIFFNER AT BS 663 LOWER VAPOR BARRIER LBL 25 WL 148 IAW SRM 51-40-02-0G-0. INSTALLED NEW STIFFNER PART #753120C IAW DRG #111A1000 IAW SRM 51-40-02-0G-0. 57309U 5/3/19SDR SWAA2022030967950Attach Angle · crackedBS 663 LOWER COMPOSITE WEB VERTICAL ATTACH ANGLE CRACKED LBL 26 WL 150 / REMOVED & REPLACED VERTICAL ANGLE BS 663 LBL. 26 WL 150 IAW SRM 51-40-02-0G-0 & DWG 111A1000 REV. A.SDR CA190503024Angle · cracked(CAN) DURING HMV INSPECTION, A CRACK WAS LOCATED ON THE AFT HOLE OF THE R/H PICK UP ANGLE. P/N S57114282201. INSPECTION TASK CARD W/O 33421433 TASK CARD 425-535141-SDI-10000-1. W/O 33421433 NR 113. PART TO BE REPLACED WITH MADE PART. PN S57114282201 (TC# 20190SDR SWAA2019060433286Gusset · crackedAFT CARGO BAY LAV BULKHEAD LOWER GUSSET CRACKED AT BS. 867, LBL 10. / R&R GUSSET IAW SRM & DWG.SDR SWAA2019053033186Support · corrodedAFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AREA CORRODED BETWEEN BS. 727 TO BS. 847, LBL 23. REPAIRED SUPPORT IAW SRM.SDR SWAA2019053033185Angle · corrodedAFT CARGO BAY ANGLE COMMON TO SHIELD FORWARD OF THE DOOR AREAS CORRODED BETWEEN BS. 767 TO BS. 792, RBL 21. R&R ANGLE PER SRM & DWG.SDR SWAA2019053033184Shield · corrodedAFT CARGO BAY SHIELD FORWARD OF CARGO DOOR CORRODED BETWEEN BS. 767 TO BS. 792, RBL 23. R&R SHIELD PER SRM & DWG.SDR SWAA2019053033183Web · corrodedAFT CARGO BAY VERTICAL WEB CORRODED BETWEEN BS. 767 TO BS. 787, RBL 6, ON FORWARD END. R&R WEB PER SRM & DWG.SDR SWAA2019053033182Shield · corrodedAFT CARGO BAY SHIELD AFT OF CARGO DOOR CORRODED BETWEEN BS. 847 TO BS. 867, RBL 21. R&R SHIELD PER SRM & DWG.SDR SWAA2019052933054Support · corrodedAFT CARGO BAY, RT FLOOR TO SIDEWALL SUPPORT CORRODED BETWEEN BS. 727 TO BS. 767, RBL 23. R&R SUPPORT IAW SRM & DWG.SDR SWAA2019052933042Support · corrodedFORWARD CARGO BAY LT FLOOR TO SIDEWALL SUPPORT CORRODED BETWEEN BS. 500 TO BS. 500D, LBL 23. REPAIRED SUPPORT IAW SRM.SDR SWAA2019052433002Fitting · crackedFORWARD CARGO BAY FLOOR TO SIDEWALL BAFFLE CLIP CRACKED AT BS. 500C, LBL 25. R&R BAFFLE CLIP IAW SRM & DWG.SDR SWAA2019052332936Intercostal · corrodedAFT PRESSURE WEB LOWER SECTION INTERCOSTAL CORRODED AT BS. 1016, BETWEEN LBL 0 TO LBL 28. REPAIRED INTERCOSTAL IAW SRM.SDR SWAA2019052232897Gusset · crackedFORWARD CARGO BAY BULKHEAD GUSSET CRACKED AT BS. 500D, STR. 19R. R&R GUSSET PER DWG & SRM.SDR SWAA2019052232896Gusset · crackedFORWARD CARGO BAY BULKHEAD GUSSET CRACKED AT BS. 500D, STR. 19L. R&R GUSSET PER DWG & SRM.SDR SWAA2019052232871Intercostal · corrodedAFT PRESSURE WEB AT FLOOR LEVEL INTERCOSTAL CORRODED AT BS. 1016. R&R INTERCOSTAL IAW SRM AND DWG.SDR ASAA2019050329368Angle · corrodedAFT CARGO COMPARTMENT LEFT AND RIGHT LOWER TRANSITION STRUCTURES, FROM STATION 807 TO 727A HAVE NUMEROUS AREAS WITH CORROSION. GROUNDED - YES. REMOVED AND REPLACED TRANSITION ANGLES IAW SRM 53-00-53 AND BAC DWG 146A7500, REV.-SDR ASAA2019050329364Support Angle · corrodedFWD CARGO COMPT. STA 500L, AFT FLOOR PANEL SUPPORT ANGLE HAS SPOTS OF CORROSION GROUNDED - YES. REMOVED SUPPORT ANGLE IAW (EXCEEDED LIMITS) SRM 51-40-02 LOCATED AND DRILLED NEW SUPPORT IAW SRM 51-40-05 AND INSTALLED IAW SRM 51-40-02 AND BAC DWG 143A9481.SDR ASAA2019050329356Transition Panel · corrodedFWD CARGO COMPT. LT STA 500F-500H, SIDEWALL TRANSITION PANEL HAS SPOTS OF CORROSION. GROUNDED - YES. FABRICATED TRANSITION PANEL IAW SRM 53-00-53, 51-40-05 AND INSTALLED IAW SRM 51-40-02 AND BAC DWG 143A7500.