SDR SWIA2019052245911Intercostal · corrodedIN AVIONICS BAY, CORROSION ACROSS INTERCOSTAL BETWEEN FS349.00 AND FS364.00 RIGHT OF STR 27. (C-CHECK) RO: 05/21/2019 REMOVED AND REPLACED INTERCOSTAL AT FS349.00 TO FS364.00 RIGHT OF STR 27 IAW SRM.SDR SWIA2019052245910Intercostal · corrodedIN AVIONICS BAY, CORROSION ON AFT SIDE OF INTERCOSTAL BETWEEN FS349.00 AND FS364.00 LEFT OF STR 27. (C-CHECK) RO: 05/21/2019 REMOVED AND REPLACED INTERCOSTAL AT FS349.00 TO FS364.00 LEFT OF STR 27 IAW SRM.SDR SWIA2019051745901Door Sill · corrodedLEFT HAND FLOOR SILL IN AFT CARGO COMPARTMENT HAS CORROSION AROUND SCREW HOLE FROM APPROX FS 559+80 TO FS 621. (C-CHECK) RO: 05/16/2019 REPLACED LT FLOOR SILL IAW SRM.SDR SWIA2019051745900Door Sill · corrodedRIGHT HAND FLOOR SILL IN AFT CARGO COMPARTMENT HAS CORROSION AROUND SCREW HOLE FROM APPROX FS 589 TO FS 621. (C-CHECK) RO: 05/16/2019 REMOVED AND REPLACED THE RT CARGO FLOOR SILL IAW REO. ALL CHECKS GOODSDR REXA2019043010539Floor Support · corrodedFLOOR SUPPORT LBL 27, INBD AND OTBD PANEL LANDINGS HAD CORRODED SPOTS BETWEEN FS 574 THRU FS 621, IN THE THE CARGO BAY. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-42-21 AND 51-42-22.SDR ASAA20190429149Transition Panel · corrodedFWD CARGO PIT L/H TRANSITION PANEL HAS MULTIPLE AREAS OF CORR FROM STA 500C+14 TO 500L. GROUNDED - YES. BLENDED MULTIPLE AREAS OF CORR ON FWD CARGO PIT L/H TRANSITION PANEL AND WAS FOUND TO BE OUT OF LIMITS IAW B737 900 ER SRM 53 00 53 1A 2 FIG 103 DETAIL D, FSDR ASAA2019041329127Channel · corrodedFWD CARGO PIT R/H TRANSITION PANEL HAS MULTIPLE AREAS OF CORR FROM STA 500A TO 500L. GROUNDED - YES. REMOVED CORR FROM FWD CARGO PIT R/H TRANSITION PANEL FROM STA 500A TO 500L FOUND TO BE OUT OF LIMITS IAW B737 900 ER SRM 53 00 53 1A 2, REPAIRED IAW B737 900 ESDR ASAA2019042329105Web · corrodedAFT CARGO COMPARTMENT LWR DOOR SILL WEB HAS CORR. GROUNDED - YES. REMOVED CORR AND CHECKED LIMITS FOUND TO BE OUT OF LIMITS IAW B737 900 ER SRM 53 60 15 1A 1 REMOVED AND REPLACED AFT PIT LWR SILL WEB IAW B737 900 ER SRM 51 40 02 0G 0 W 1 O .050 R .044 L 30 D .SDR DALA2019041752488Drain · crackedCRACKED DRAIN THRESHOLD AT L1 DOOR ENTRY. DRAIN THRESHOLD AT L1 DOOR ENTRY, WAS REPAIRED (WELDED) PER ER/A 577069-14 REV. ORIG SECTION I, PERMANENT REPAIR ASSOCIATED ER/A 00-577069 ADDED FOR AC 6710.SDR DALA2019041742487Strap · corrodedCORROSION ON STRAP STA 1681 LB 0 FROM STA AT PASSENGER CABIN FLOOR STRUCTURE. W4. CORROSION LEVEL 2. PASSENGER CABIN FLOOR STRUCTURE W4 WAS REPLACED PER B757-200 S.R.M. 51-40-02 PAR. 4 AND 7 AND DWG. 146N5216. (LP# 1029185)SDR DALA2019041642471Web · cracked(LOG 1029164) DURING INSPECTION FOUND CRACK WEB BS 294.5 TO BS 312 AND RBL 31 AT FWD GALLEY AREA. REPLACED WEB BS 294.5 TO BS 312 AND RBL 31 AT FWD GALLEY AREA AS PER SRM B737-800 51-40-02 AND DRAWING #141A5400.SDR AALA2019041659011Splice · elongatedAIRCRAFT IN BASE MAINTENANCE: OUTBOARD LOWER SPLICE LOCATED AT FR 64 AND -Y1292 HAS ELONGATED HOLE. REPLACED SPLICE PER SRM 51-72-11.SDR P5CA2019041600057Support Bracket · crackedAPU COMPARTMENT R/H STA 2696 CONDUIT SUPPORT BRACKET MOUNTED FRAME CRACKED.(<P>APU COMPARTMENT R/H STA 2696 WL 292, LOWER SUPPORT FRAME CRACK AREA REPAIRED IAW RI-53-82-13469 REV. A. </P>)SDR DALA2019041642464Floor Support · corrodedCORROSION LOWER SILL LOCATED FR66 TO FR68 RH SIDE AT AFT GALLEY AREA (1 EA). PERFORMED PERMANENT REPAIR ON LOWER SILL LOCATED FR66 TO FR68 RH SIDE AT AFT GALLEY AREA ASPER A319 SRM 53-41-14-300-001 REPAIR PRINCIPLE 5 PAGE 7 JOB COMPLETE.SDR DALA2019041632463Floor Support · corrodedCORROSION CENTER FITTING LOC FROM FRAME 66 TO FRAME 68 AT LEVEL STR 23 R AT AFT GALLEY AREA (1 EA). REPLACED CENTER FITTING LOC FROM FR 66 TO FR 68 AT LEVEL STR 23K AT AFT GALLEY AREA ASPER A319 SRM 51-72-11 AND DRAWING #D53480508.SDR SWAA2022030805823Strip · corrodedFWD CARGO LH AFT MOST CAPSTRIP BETWEEN SIDEWALL AND FLOOR PANEL HAS CORROSION ON BOTTOM SURFACE. / REMOVED AND REPLACED CORRODED CAPSTRIP WITH NEW CAPSTRIP PART # 453A1611-10.CAPSTRIP TO BE INSTALLED ON FWD CARGO COMPARTMENT LINERS TASK #725-052-00-01.SDR SWAA2022030705832Angle · corrodedCORROSION FOUND ON AFT CARGO R/H TRANSITION ANGLE AT STA 747-767. / REMOVED AND REPLACED AFT CARGO R/H TRANSITION ANGLE AT STA 727-767. PER SRM 51-40-02.SDR SWAA2019050732360Fitting · crackedAFT CARGO BAY BULKHEAD FITTING CRACKED AT BS. 947, LBL 10. R&R FITTING PER SRM AND DWG.SDR SWIA2019050345820Cleat · corrodedPAX DOOR FWD AND AFT CLEATS CORRODED AROUND NUTPLATES. (C-CHECK) RO: 05/02/2019 REMOVED AND INSTALLED NEW CLEATS P/N 601R31527-137 AND 601R31527-217, IAW SRM.SDR REXA2019043020540Seat Track · corrodedR/H SEAT RAIL #5 HAS CORROSION IN SEVERAL AREAS. REMOVED AND REPLACED R/H #5 SEAT RAIL. I.A.W. CRJ-200 AMM 53-01-11 AAR SM 33SDR SWAA2019042932063Scuff Plate · crackedAFT CARGO DOOR CUT OUT AFT CORNER SCUFF PLATE CRACKED. / R&R SCUFF PLATE IAW EA AND AMM.SDR SWAA2019042932062Scuff Plate · crackedAFT CARGO DOOR CUTOUT FORWARD CORNER SCUFF PLATE CRACKED. / R&R SCUFF PLATE IAW AMM AND EA.SDR RAIA201904120032Angle · crackedR/H OVERWING ANGLE AT FR 41 CRACKED.... R&R R/H OVERWING ANGLE AT FR 41.SDR R61A201904280434Bracket · corrodedAFT CARGO , INTERNAL STRUCTURE (BRACKET P/N 170-85667-001) CORRODED. REMOVED AND REPLACED PER SRM 51-41-02SDR RAIA201904260031Angle · crackedLEFT OVERWING ANGLE AT FR 46 CRACKED- REMOVED AND FAB NEW ANGLE. INSTALLED ANGLE, STILL REQUIRES 2 HI-LOK TO BE INSTALLED AND NUTPLATE HOLES TO BE PICKED UP FROM FAIRING. INSTALLED HI-LOKS, APPLIED SEALANT AND PICKED UP NUT PLATE HOLES.SDR REXA2019042600515Angle · corrodedCORROSION AND MISSING SCREWS ON LOWER SURROUND STRUCTURE AT GALLEY SERVICE DOOR. AREAS OUT OF LIMITS, DUE TO EXCESSIVE CORROSION ON ANGLE MOUNTING LOWER SURROUND STRUCTURE AT GALLEY SERVICE DOOR, MUST BE REPLACED PER CRJ-900 SRM 53-00-00-101-001-A01, ANGLE MSDR R61A201904260421Angle · corrodedWHILE IN HEAVY CHECK, MAINTENANCE FOUND HEATED DRAIN MAST ANGLES ARE CORRODED AFT OF FR87 BETWEEN STRG.27R AND 28R. MAINTENANCE REMOVED AND REPLACED 2EA HEATED DRAIN MAST INTERCOSTAL CLIPS (ANGLES) AFT OF FR87 BETWEEN STGR 27R-28R REF. EMB SRM 51-40-08. PNS RSDR R61A201904260420Shear Panel · corrodedWHILE IN HEAVY CHECK, MAINTENANCE FOUND LEVEL 2 CORROSION CENTER FUSELAGE III WET AREA 53-23 CENTER SHEAR PANEL. MAINTENANCE REMOVED AND REPLACED NEW CENTER FUSELAGE III WET AREA 53-23 CENTER SHEAR PANEL REF EMB SRM 51-40-08.SDR RAIA201904250030Angle · crackedRH OVERWING ANGLE AT FR 46 CRACKED. REPAIRED RH OVERWING ANGLE AT FR 46.SDR RAIA201904250029Floor Support · corrodedRH FL SILL AFT OF THE SVC DOOR IS CORRODED. REMOVED CORRODED SERVICE DOOR AFT FLOOR SILL. BACK DRILLED ALL FASTENERS HOLES ON NEW R/H FLOOR SILL AFT OF SVC DOOR. INSTALLED SERVICEABLE SVC DOOR AFT SILL.SDR R61A201904120418Upper Sheet · corrodedIN HEAVY CHECK, MAINTENANCE FOUND LEVEL 2 CORROSION STRUCTURAL CENTER FUSELAGE III DRY AREA 53-23 RH UPPER SHEET. MAINTENANCE REMOVED AND REPLACED RH UPPER SHEET. REF EMB SRM 51-40-08.SDR RAIA201904240027Angle · crackedLH OVERWING ANGLE AT FR 48 CRACKED. REMOVED LH OVERWING ANGLE AT FR 48, DRILLED NEW ANGLE.SDR RAIA2019042420025Floor Support · corrodedL/H SILL BT FR 24-27 IS CORRODE....R&R L/H FLOOR SIL AT FR 24-27SDR RAIA2019042320021Bracket · crackedCENTER OMEGA BEAM GUSSET BT FR 16-17 ANGLE BRACKET IS CRACKED....R&R CENTER OMEGA BEAM ANGLE BRACKET AT FR 16-17SDR RAIA2019042800020Floor Support · corrodedLEFT FLOOR SILL BT FR 30-35 IS CORRODED....R&R L/H FL SILL BT 30-35.SDR RAIA2019042300018Gusset · crackedL/H OMEGA BEAM GUSSET AT FR 16 HAS CRACKED BRACKET. REMOVED AND RAPLACED L/H OMEGA BEAM GUSSET AT FR 16.SDR RAIA201904201014Floor Support · corrodedRH FL SILL BT FR 23-29 IS CORRODED. REMOVED SILL, MATCH DRILLED. INSTALLED FLOOR SILL.SDR RAIA2019042000013Floor Support · corrodedRH FL SILL AT FR 46 IS CORRODED. REMOVED RH FLOOR SILL. PICKED UP HOLES AND PARTIALLY INSTALLED RH FL SILL. INSTALLED FLOOR SILL.SDR R61A2019041920390Gusset · corrodedDURING HEAVY CHECK MAINTENANCE FOUND CORROSION STRUCTURAL CENTER FUSELAGE III WET AREA 53-23 RH CENTER GUSSET
FRAME 90.REMOVED AND REPLACED CENTER FUSELAGE III WET AREA 53-23 RH GUSSET PLATE FRAME 90. REF EMB SRM 51-40-08. A/C REMAINS IN CHECK.SDR R61A2019041920389Support · corrodedDURING HEAVY CHECK MAINTENANCE FOUND CORROSION STRUCTURAL CENTER FUSELAGE III WET AREA 53-23 RH AFT PANEL SUPPORT. REMOVED AND REPLACED STRUCTURAL CENTER
FUSELAGE III WET AREA 53-23 R/H AFT PANEL SUPPORT. REF: SRM 51-40-08. A/C REMAINS IN CHECK.SDR RAIA2019041920011Floor Support · corrodedLH FL SILL BT FR 55-60 IS CORRODED- R&R THE L/H FLOOR SILL FROM FR 55-60.SDR R61A2019041920388Shear Plate · corrodedDURING HEAVY CHECK MAINTENANCE FOUND CORROSION STRUCTURAL CENTER FUSELAGE III WET AREA 53-23 RH SHEAR PLATE. REMOVED AND REPLACED STRUCTURAL CENTER FUSELAGE III WET AREA 53-23 RH SHEAR PLATE REF. EMB SRM 51-40-08. A/C REMAINS IN CHECK.SDR RAIA2019041920010Floor Support · corrodedRH CARGO BAY FL SILL BT 65-68 IS CORRODED- REMOVED RH CARGO BAY FL SILL AND PICKED UP THE HOLES ON NEW PART, NEEDS INSTALLED ON A/C. INSTALLED RH CARGO BAY FL SILL.SDR ASAA2019041829016Floor Support · crackedCRACK FOUND ON CABIN FLOOR SUPPORT, APPROXIMATELY 2.5 INCHES LONG AT FLOOR 221EF, (STREAMER ATTACHED AND CIRCLED IN RED). GROUNDED - YES. REMOVED INTERCOSTAL IAW B737-900 SRM 51-40-02. LOCATED, DRILLED AND INSTALLED NEW INTERCOSTAL IAW BOEING DWG 141A5400 REV-SDR RAIA2019041820009Floor Support · corrodedRH FL SILL BT FR 36-41 IS CORRODED, R&R RH FL SILL BT FR 36-41.SDR RAIA2019041852004Floor Support · corrodedLH FL SILL BT FR 36-41 IS CORRODED. REMOVED & REPLACED LH FL SILL BT FRAME 36-41.SDR RAIA2019041520003Floor Support · corrodedFL SILL ON CENTER & LH OMEGA BEAM BT FR 60-58 IS CORRODED. R&R THE CENTER OMEGA BEAM GUSSET FROM FR 58-60. R&R THE L/H OMEGA BEAM GUSSET FROM FR 58-60.SDR SWAA2019041631765Support Fitting · crackedAFT CARGO BAY AFT BULKHEAD SUPPORT FITTING CRACKED AT BS. 949, LBL 6. R&R FITTING PER DWG AND SRM.SDR AALA2019041659019Door Sill · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON DOOR SILL AT FR 68 AND Y1500. REPAIRED DOOR SILL PER SRM 53-41-14-300-001 REPAIR PRINCIPAL 7.SDR DALA2019041302461Floor Support · corrodedCORROSION FLOOR BEAM +Y254 LOC.FR12 TO FR24 FWD GALLEY AREA (1 EA). REPLACED FLOOR BEAM +Y254 LOC. FR 12 TO FR 24 FWD GALLEY AREA AS PER A319 SRM 51-72-11 AND DRAWINGS D53112816 RELEASE DATE 08-JAN-97, D53110920 RELEASE DATE 07-DEC-99 AND D53110984.