JASC 5320
Service difficulty reports · 216,415
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2019032601968Angle · cracked(LOG 1001496) DURING INSPECTION FOUND CRACK ANGLE BETWEEN BS380 TO BS400 AND RBL10 AT FWD GALLEY AREA. REPLACED ANGLE BETWEEN BS 380 TO BS 400 AND RBL10 AT FWD GALLEY AREA AS PER SRM 51-40-02 AND DRAWING 143A5400 SHEET 38 REV A.SDR DALA2019032601914Cusp Web · canningINITIAL INSPECTION: OIL CANNING ON CABIN FLOOR CUSP WEB BTW STA 665/674 LT. WEB WAS REPAIRED PER SRM 53-00-55-2R-4. (LP1002124)SDR IPXA2019032540444Floor Support · crackedINSPECTION TYPE:N/A BULK PIT FLOOR PANEL SUPPORT STRINGER STA 1440 LBL 36.91 HAS .5" CRACK TOP SECTION OF CHANNEL. REPAIRED IAW EO EO B767-5310-72036-A.SDR SWAA2022030492393Strip · brokenAFT CARGO PIT CAP STRIP FWD OF DOOR R/H SIDE BROKE IN HALF / REMOVED + REPLACED AFT CARGO PIT CAP STRIP FWD OF DOOR IAW SRM 51-40-02; PN: 433A2611-11SDR SWAA2022022576243Baffle · crackedFWD CARGO INTERCOSTAL ATTACH CLIP CRACKED AT BS 400 LBL25' / REMOVED BAFFLE CLIP AT STA 400 LBL25 IAW SRM 51-40-02-0G-0. VERIFIED NEW BAFFLE P/N - 143A7502U5 ON ATAG#A17245 IAW BOEING DWG # 143A7505 REV B. LOCATED AND DRILLED NEW BAFFLE CLIP IAW BOEING DWG #14SDR K11A20200105323Tee Fitting · crackedAT STATION 277-360 STR 20L OUTER "T" CHORD IS CRACKEDSDR SWAA2019051532689Angle · corrodedFORWARD CARGO Z ANGLE CORRODED BETWEEN BS. 400 TO BS. 480, LBL 22. R&R Z-ANGLE PER SRM.SDR SWAA2019051532688Shield · corrodedFORWARD CARGO SHIELD CORRODED BETWEEN BS. 500 TO BS. 500A, RBL 22. R&R SHIELD PER DWG AND SRM.SDR SWIA2019050145806Strap · corrodedRT SIDE FUSELAGE STRAP AT 559.0 HAS CORROSION.AT APPROX RBL 36. (C-CHECK) RO: 04/28/2019 REMOVED AND REPLACED THE RT STRAP AT FS559 RBL 27 - RBL 42 IAW SRM. ALL CHECKS GOOD.SDR SWIA2019050145805Door Sill · corrodedLEFT SIDE INTERNAL FUSELAGE FLOOR SILL AT APPROX LBL 42 HAS CORROSION IN VARIOUS AREAS FROM FS 559.0 TO 559.0+ 80. (C-CHECK) RO: 04/28/2019 BLENDED OUT CORROSION AT VARIOUS LOCATIONS ON FLOOR SILL AT LBL 42 BETWEEN FS 559.0 TO FS 559.0 + 80 IAW SRM AND REO.SDR SWIA2019050145804Strap · corrodedAT FS 559.0 INTERNAL FUSELAGE LEFT SIDE UPPER STRAP (FLOOR LEVEL) HAS CORROSION. (C-CHECK) RO: 04/28/2019 REMOVED AND INSTALLED NEW LT FLOOR STRAP AT FS559 LBL 27 - LBL 42 IAW SRM. PRESSURE CHECK GOOD.SDR SWAA2019041531686Shield · corrodedFORWARD CARGO COMPARTMENT SHIELD CORRODED BETWEEN BS. 492 TO BS. 500A, RBL 19. R&R SHIELD IAW SRM & DWG.SDR SWAA2019040931523Sidewall Support · corrodedFORWARD CARGO COMPARTMENT FLOOR SIDEWALL SUPPORT CORRODED BETWEEN BS. 396 TO BS. 500D, LBL 19. / R&R ANGLE IAW SRM AND DWG.SDR SWAA2019040931522Sidewall Support · corrodedFORWARD CARGO COMPARTMENT FLOOR SIDEWALL SUPPORT CORRODED BETWEEN BS. 500A TO BS. 500D, RBL 19. / R&R SUPPORT IAW SRM & DWG.SDR SWAA2019040931521Sidewall Support · corrodedFORWARD CARGO COMPARTMENT FLOOR SIDEWALL SUPPORT CORRODED BETWEEN BS. 396 TO BS. 420, RBL 19. / R&R ANGLE IAW SRM AND DWG.SDR REXA2019040824407Support Angle · corrodedAWR; [ TASK R53520 STEP 7 ]; INITIAL INSPECTION: CORROSION ON PROTECTION PLATE SUPPORT IN STA. FS= 329 BETWEEN 41RBL TO 44RBL AT GALLEY SERVICE DOOR LOWER SILL, FWD WET AREA. (W1) (CPAX)
SUMMARY: LEVEL CORROSION 2; PROTECTION PLATE SUPSDR REXA2019040824406Support Angle · corrodedAWR; [ TASK R53520 STEP 7 ]; INITIAL INSPECTION: CORROSION ON PROTECTION PLATE SUPPORT IN STA. FS= 322 BETWEEN 41RBL TO 44RBL AT GALLEY SERVICE DOOR LOWER SILL, FWD WET AREA. (W1) (CPAXSUMMARY: LEVEL CORROSION 2; PROTECTION PLATE SUPPORT IN STA. FS= 322 BETWEESDR REXA2019040834366Gutter · crackedPASSENGER DOOR RAIN GUTTER CRACKED AT CTR LINE OF DOOR OPENING. FWD CROWN SKIN BUTT SPLICE.
REMOVED AND REPLACED RAIN GUTTER. I.A.W. CRJ-200 SRM 51-42-06 AAR SM 139SDR REXA2019040800357Floor Support · corrodedAFT CARGO FLOOR SUPPORT LBL27.0 HAS CORROSION FROM FS 574.00 TO FS605.00
REMOVED AND RE-PLACED LBL-27 FS 574.0 TO FS605 FLOOR SUPPORT I.A.W. VRJ-200 SRM 51-42-21 AAR R SM 17SDR SWAA2019040331303Support Angle · corrodedFORWARD CARGO COMPARTMENT AFT BULKHEAD SUPPORT ANGLE CORRODED AT BS 500D, BETWEEN LBL 19 TO RBL 19. R&R ANGLE IAW SRM AND DWG.SDR SWAA2019040331302Shield · corrodedFORWARD CARGO COMPARTMENT SHIELD FORWARD OF CARGO DOOR CORRODED BETWEEN BS 420 TO BS 440, RBL 19. R&R SHIELD PER SRM AND DWG.SDR DALA2019032501908Structure · corrodedCORROSION LEVEL: 2 CORROSION INTERNAL STRUCTURE BELOW CABIN FLOOR PANELS LOC APROX +Y1 732 IN PASSENGER CABIN AND FRAME 42+18. PERFORMED REPAIR INSTRUCTIONS ON INTERNAL STRUCTURE SIDE BOX LOC +Y1732 AND FRAME 42 TO FR 43 IN PASSENGER CABIN AS PER PRI #576371-1SDR AALA2019032540006Expansion Joint · crackedCABIN FLOOR EXPANSION JOINT CRACKED BETWEEN BS 540 AND 541, BETWEEN LBL 2 AND LBL 23. REPLACED THE EXPANSION JOINT IAW RD 51-00-05.SDR AALA2019032540005Floor Support · crackedFORWARD WET AREA FLOOR SUPPORT WAS CRACKED AT BS 333, LBL 46. REPLACED THE FLOOR SUPPORT IAW RD 51-00-05-1.SDR AALA2019032540004Floor Support · crackedFORWARD WET AREA FLOOR SUPPORT WAS CRACKED AT BS 327, LBL 46. REPLACED THE FLOOR SUPPORT IAW RD 51-00-05-1.SDR DALA2019032501887Spacer · corrodedINITIAL INSPECTION: CORROSION AT SPACER OF THE CENTER LOWER CARGO DOOR JAMB BEAM. (CORROSION LEVEL 2): SPACER WAS REPLACED PER SRM 53-05 FIG 123A (SHEET1). (LP1000032)SDR A6WA2019032546517Intercostal · crackedAEB STR 14L INTERCOSTAL CRACKED. REPLACE INTERCOSTAL IAW SRM 51-42-06, 51-42-21.SDR ASOA201903247033Structure · gougedTYS A/C IS IN C-CHECK WHEN INSPECTION FOUND A SMALL GAUGED ON FACE OF THE FLANGE AT FR. 35 AND STRINGER 16L. MAINTENANCE REPAIRED THE AREA AT FR.35 AND STR. 16L IAW SRM 53-00-04 FIG. 206. ALL WORK ACCOMPLISHED AND WILL BE RELEASED AT THE END OF THE CHECK.SDR VNAA2019032499909Angle · crackedFS409+128 VERT POST @ BLO HAS A CRACK INDICATION NOTED ON BOTH LT & RT SIDES IN THE AFT RADIUS @ WL69 (MARKED ON A/C) BOTH FAILED NDT INSP. CORRECTIVE ACTION: DRILLED UP NEW SERVICEABLE ANGLES P/N 601R32208-131/132 IAW SRM 51-40-11 TR51-42.SDR VNAA2019032499905Doubler · corrodedGALLEY FLOOR MOUNT FITTING IS CORRODED AT RBL 5 AT FS 316. CORRECTIVE ACTION: REPLACED GALLEY FLOOR SUPPORT DOUBLER PN: 601R387781-1 IAW SRM 51-42-06, 51-42-13.SDR WVER2019032401Angle · corrodedFWD "J" ANGLE AT FS 280.00 FOUND TO BE CORRODED.SDR SWIA2019050145803Intercostal · corrodedAVIONICS BAY, BELOW FLOOR BOARD BETWEEN FS 394.0 TO FS FS 409.0 THERE IS EVIDENCE OF CORROSION AT INTERCOSTAL AT STR 27L. (C-CHECK) RO: 04/28/2019 REMOVED AND REPLACED THE LT INTERCOSTAL BETWEEN FS 394.0 AND 409 AT STR 27L IAW SRM. PRESSURE LEAK CHECK GOOD.SDR SWIA2019050145802Intercostal · corrodedAVIONIC BAY BELOW FLOOR BOARD IN BETWEEN FS 349 AND FS 364 INTERCOSTAL HAS EVIDENCE OF CORROSION.AT STR 27R (C-CHECK) RO: 04/28/2019 BLENDED OUT CORROSION FROM INTERCOSTAL AT AVIONIC BAY BELOW FLOOR BOARD IN BETWEEN FS 349 AND FS 364, STR 27R IAW SRM. PRESSURESDR SWIA2019050145801Intercostal · corrodedAVIONICS BAY BELOW FLOOR BOARD INTERCOSTAL BETWEEN FS 349 AND FS 364 HAS EVIDENCE OF CORROSION AT STR27L. (C-CHECK) RO: 04/28/2019 REMOVED AND REPLACED INTERCOSTAL BETWEEN FS 349.0 AND FS364.0 AT STR27L IAW SRM. ALL CHECKS GOODSDR SWAA2019041631760Intercostal · corrodedINTERCOSTAL SPLICE CORRODED AT BS. 967, STR. 21R. / R&R INTERCOSTAL SPLICE PER SRM AND DWG.SDR SWAA2019040931520Channel · corrodedAFT CARGO COMPARTMENT Z-CHANNEL CORRODED BETWEEN BS. 727 TO BS. 807, LBL 19. / R&R ANGLE IAW SRM AND DWG.SDR REXA2019040833360Seat Track · corrodedLH SEAT TRACK #2 GOUGED AND HAS CORROSION.
REPLACED SEAT TRACK I.A.W. CRJ-200 AMM 53-01-11 AAR SM 109SDR SWAA2019040431359Splice · corrodedAFT CARGO BAY 1016 Y CHORD SPLICE CORRODED AT BS. 1016, BETWEEN STR. 26L TO STR. 26R. / R&R Y CHORD IAW SRM AND DWG.SDR REXA2019032300320Striker · wornINITIAL INSPECTION: WEAR AFT SEAL STRIKER ON CUTOUT AT PASSENGER DOOR (FUS) (SM) SUMMARY OF NRC 00244:SEAL STRIKER WAS REPAIRED PER SRM 53-21-23-201-003-A01.SDR REXA2019032300319Striker · wornINITIAL INSPECTION: WEAR FWD SEAL STRIKER ON CUTOUT AT PASSENGER DOOR (FUS) (SM). SUMMARY OF NRC 00243:DOUBLER WAS REPLACED PER SRM 51-42-06-001-001-A01 AND 53-21-23-201-003-A01.SDR AALA201903289022Floor Support · corrodedCORROSION FOUND ON THE FLOOR SUPPORT, FRAME 30, STRINGER 23L. REPLACED THE FLOOR SUPPORT IAW SRM 51-75-12.SDR JJBA20190323012Floor Support · corrodedCORROSION FOUND ON THE OMEGA BEAM FR 59/60 AFTER OMEGA BEAM GUSSET REMOVAL. REPAIRED CENTER OMEGA BEAM FR 59-60, JUST FWD OF FRAME 60.SDR DALA2019032401919Web · cracked(LOG 0998608) DURING INSPECTION FOUND CRACK WEB BTW BS 274 TO BS 294 AT LEVEL BL 0 AT FWD GALLEY AREA. REPLACED WEB BTW BS274 TO BS294 AT LEVEL BL 0 AT FWD GALLEY AREA ASPER SRM 51-10-02 PARAGRAPH 9 AND DWG 141A5400.SDR A6WA2019032546516Door Sill · crackedFS589.00, LBL43 CLIP UNDER CARGO DOOR SILL IS CRACKED. REPLACED CLIP IAW SRM 51-42-06, 51-42-21.SDR SWAA2022030437039Plate · corroded**CORROSION**AFT CARGO COMPT STA 878 FROM LBL 9 TO RBL 20 WL 162 SPLICE PLATE HAS MULTIPLE CORRODED AREAS. (LOCATED ON PARTS RACK) / RECEIVED NEW SPLICE PLATE TO REPLACE OUT OF LIMITS CORROSION PN #146A9401-39 SI #750863 LOT #5079348. REPLACED ON PARTS RACK.SDR SWAA2022030437037Shield · corroded**CORROSION** AFT CARGO COMPT. BETWEEN STA 767 AND STA 794 RBL 19 STR 25 WL 162 SHIELD CORRODED AT SEVERAL FASTENER HOLES. / REMOVED AND REPLACED NEW REPLACEMENT SHIELD; PART #146A8127U12; PER SRM 51-40-02-0G-0; DWG. 146A0081 REV A. PART #7531132 PO #735615; SSDR SWAA2022030471302Angle · corroded***CORROSION*** AFT CARGO AFT BULKHEAD SUPPORT ANGLE STA 947.5 RBL3 WL156 / AFT CARGO BULKHEAD B.S 947.5 SUPPORT ANGLE RBL 3 WL 156 FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE LIMITS IN SRM LOCATED AND DRILL NEW ANGLE PER SRM 51-40-05 AND DWG 149A8118 INSTALSDR SWAA2022030445873Angle · corrodedFWD CARGO AT BS 500I AFT BLKD LOWER SUPPORT ANGLE CORRODED LBL22. / REMOVED AND REPLACED FWD CARGO BULKLHEAD LOWER SUPPORT ANGLE BS 500I LBL22. FOUND TO BE OUT OF LIMITS NO WRITTEN LIMITS. IAW B737 SRM 51-40-02-0G-0 PARA 4;DWG 143A9481 ID 0017 REV-.SDR SWIA2019050145797Support · crackedAFT CARGO DOOR SUPPORT STRUCTURE FWD TRACK SUPPORT AT FS 578.0 HAS CRACKED ANGLE. (C-CHECK) RO: 04/28/2019 NEW AFT CARGO DOOR FWD TRACK SUPPORT ANGLE INSTALLED IAW SRM.SDR SWIA2019050145796Track · damagedAFT CARGO DOOR FWD SUPPORT TRACK STRUCTURE. U CHANNEL IS DAMAGED. APPROX FS 574.0. (C-CHECK) RO: 04/28/2019 REPAIRED AFT CARGO DOOR FWD SUPPORT TRACK STRUCTURE U CHANNEL IAW REO.