JASC 5320
Service difficulty reports · 216,415
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RAIA2001903060004Angle · corrodedPAX DOOR LOWER THRESHOLD 2EA NUTPLATES "Z" ANGLE HAS CORROSION AROUND NUTPLATE HOLES. R&R PASSENGER DOOR LOWER THRREHOLD "Z" ANGLES. NUTPLATE HOLES NEED TO BE PICKED UP. LOCATED AND INSTALLED NUTPLATES ON PASSENGER DOOR LOWER THRESHOLD "Z" ANGLES.SDR ASAA2019030628534Stiffener · crackedLT WW ATTACHED ANGLE O/B SIDE OF ACM EXHAUST RING IS CRACKED. GROUNDED - YES. REMOVED AND REPLACED ANGLE STIFFENERS IAW SRM 51 40 02 0G 0 PARA 4 AND 7.D.SDR DALA2019030701585Support · corrodedSHIP 6707 INITIAL INSPECTION: CORROSION ON SCUFF PLATE L2/R2 SUPPORTS (LWR SILL) FROM FS 680 TO 720 (FUS). CORRECTIVE ACTION: SUMMARY OF NRC 00248. LEVEL CORROSION 1. CORROSION ON SCUFF PLATE L2 SUPPORTS (LWR SILL) FROM FS 680 TO 720 WAS ATTENDED PER ERA 57612SDR RAIA201903060003Structure · corrodedRT OMEGA BEAM STOP SIGN HAS CORROSION AT FR 22. REMOVED OMEGA BEAM STOP SIGN AT FRAME 22 RT. LOCATED AND DRILLED NEW PART. OMEGA BEAM STOP SIGN READY FOR INSTALL. INSTALLED RT OMEGA BEAM STOP SIGN AT FRAME 22.SDR RAIA201903060002Structure · corrodedRT OMEGA BEAM UPPER STOP SIGN HAS CORROSION AT FR20. REMOVED RT OMEGA BEAM STOP SIGN AT FRAME 20. LOCATED AND DRILLED STOP SIGN. READY TO INSTALL NEW PART. INSTALLED RT OMEGA BEAM UPPER STOP SIGN AT FRAME 20.SDR CALA2019030800363Door Sill · corrodedR2 SILL BEAM CORRODED AT FR66. REF. N/R:99830115 REMOVED AND REPLACED R2 DOOR SILL BEAM PIN 31-2098-3-2394 PO #1590766 IAW SRM 53-41-14, 51-44-11 AND 51-42-11. R2 DOOR GIRT BAR FITTING ADJUSTMENT WILL ACCOMPLISH ON N/R 99833908. REF.99830115.SDR A6WA2019030846458Intercostal · crackedAEB STR 13L INTERCOSTAL CRACKED. REPLACED.SDR AALA201903076006Transition Panel · corrodedCORROSION FOUND ON THE FORWARD CARGO BAY RIGHT TRANSITION PANEL, BS 500E - 500I, STRINGER 25R. REPLACED THE TRANSITION PANEL IAW SRM 53-00-53-2R-5.SDR AALA201903076005Transition Panel · corrodedCORROSION FOUND ON THE FORWARD CARGO BAY RIGHT TRANSITION PANEL, BS 500A - 500E, STRINGER 25R. REPLACED THE TRANSITION PANEL IAW SRM 53-00-53-2R-5.SDR AALA201903076003Floor Support · corrodedCORROSION FOUND ON THE AFT GALLEY FLOOR SUPPORT BETWEEN BS 947 & 957, LBL 51. REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02.SDR DALA2019030701520Spacer · corrodedCORROSION ON PREVIOUS REPAIR (SPACER) AT AFT CARGO DOOR CUT OUT LWR AREA. CORROSION LEVEL 2. SPACER AT AFT CARGO DOOR CUT OUT LWR AREA WAS REPLACED PER SRM VOL. I 53-60-02 FIG 9. (LP# 0973285)SDR DALA2019030701515Angle · corrodedCORROSION ON ANGLE CUSP ON R1 LOWER DOOR JAMB FROM Y=160 TO Y=200 AT CABIN PAX (5300-2010). (W1). NRC 0318: CORROSION LEVEL 2, ANGLE CUSP ON R1 LOWER DOOR JAMB FROM Y=160 TO Y=200 AT CABIN PAX WAS REPAIRED PER REPAIR PER ETI-17-19-020 REV.1. AND SRM 51-41-02-0SDR SWAA2022030463389Angle · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE LEFT TRANSITION ANGLE HAS CORROSION AT FASTENER HOLES FROM STA- 807 THROUGH 827. FASTENER HOLES MARKED. / LOCATED AND REPLACED L/H TRANSITION ANGLE FR. 727-847 PART # 146A7502-27 PER SRM 51-40-02SDR SWAA2022030463386Angle · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE LEFT TRANSITION ANGLE HAS CORROSION AT FASTENER HOLES FROM STA 747 TO STA 767 LBL21. / REMOVED AND REPLACED L/H TRANSITION ANGLE FR. 727-847 PART # 146A7502-27 PER SRM 51-40-02SDR SWAA2022030463387Angle · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE LEFT TRANSITION ANGLE HAS CORROSION AT FASTENER HOLES FROM STA 767 TO STA 787 LBL21. / REMOVED AND REPLACED L/H TRANSITION ANGLE FR. 727-847 PART # 146A7502-27 PER SRM 51-40-02SDR SWAA2022030463384Angle · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE RIGHT TRANSITION ANGLE HAS CORROSION AT FASTENER HOLES FROM STA 767 TO STA 787 RBL 21. / REMOVED AND REPLACED RIGHT TRANSITION ANGLE STA 767-STA787 RBL 21 IAW SRM 51-10-02. INSTALLED RIGHT HAND TRANSITION ANGLE IAW SRM 51-SDR SWAA2022030463382Angle · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE RIGHT TRANSITION ANGLE HAS CORROSION AT FASTENER HOLES FROM 727D+10 TO STA 747 RBL 21. / REMOVED AND REPLACED R/H TRANSIYION ANGLE FR. 727-767 ;PART # 146A7505-12 PER SRM 51-40-02SDR SWAA2022030463381Angle · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE LEFT TRANSITION ANGLE HAS CORROSION AT FASTENER HOLES FROM 727D+10 TO STA 727D+15 LBL 21. / REMOVED AND REPLACED L/H TRANSITION ANGLE FR. 727-847 PART # 146A7502-27 PER SRM 51-40-02SDR SWAA2022030492199Vapor Barrier · crackedVAPOR BARRIOR CRACK ON R/H GEAR '5' IN LENGTH / APPLIED INTERIM REPAIR PER SRM 57-10-10-1A-2 REPETITIVE ACTION REQUIREDSDR SWAA2022030492200Vapor Barrier · crackedL/H VAPOR BARRIER CRACKED APPX. '5' IN LENGTH / APPLIED INTERIM REPAIR PER SRM 57-10-10-1A-2SDR SWAA2022030403774Stiffener · crackedFOUND CRACKED L/H VERTICAL STIFFENER BS 663 LBL 26 WL145 / LOCATED + DRILLED NEW L/H VERTICAL STIFFENER BS 663 LBL 26 WL 145 IAW SRM 51-40-05 + DWG 111A1001. PO# 737827. ISNTALLED NEW VERTICAL STIFFENER IAW SRM 51-40-02-0G-0 + DWG 111A1000. 56379U 03APR19SDR SWAA2022030403775Stiffener · crackedFOUND CRACK R/H HORIZONTAL STIFFENER BS 663 RBL 20 WL152. / LOCATED AND DRILLED NEW STIFFNER ITEM 7530305 PO# 737827 PER SRM 51-10-02-0G-0; SRM 51-40-05-0G-0 AND BOEING DWG 111A1001 REV B 57335U 8/25/19 TO BE INSTALLED ON DEFECT# N187951 AT R/H BS663 RBL 20 WLSDR SWAA2022030445666Tie Down · corrodedAFT CARGO COMPARTMENT FWD TIE DOWN PLATE LOWER SURFACE CORRODED / RECIEVED NEW TIE DOWN PLATE FOR AFT CARGO INSTALLED IN AFT CARGO IAW SRM 51-40-02 FILLET SEALED IAW AMM 51-31-00-390-804SDR SWAA2022030445667Tie Down · corrodedAFT CARGO COMPARTMENT AFT TIE DOWN PLATE LOWER SURFACE CORRODED / RECIEVED NEW TIE DOWN PLATE FOR AFT CARGO INSTALLED IN AFT CARGO IAW SRM 51-40-02 FILET SEALED IAW AMM 51-31-00-390-804SDR AALA201906039029Floor Support · corrodedAIRCRAFT IN BASE VISIT: SEVERAL (APPROX. 1" X .5" X 0.035") CORRODED AREAS ON FLOOR BEAM BTW FR 66 AND FR 69, Y 1250. REMOVED AND REPLACED FLOOR BEAM P/N D5347218820400 IAW SRM 51-72-11-911-001, PAR2; SRM 51-42-11.SDR SIMA20190305012Floor Support · corrodedLT OMEGA BEAM IS CORRODED BETWEEN FRS 58 AND 59. C/A-COMPLETE:REPAIRED LT OMEGA BEAM BETWEEN FR.58-59 IAW SRM 53-24-10. C/W D.T CHECKLIST 15-27.SDR SIMA20190305016Floor Support · corrodedRT OMEGA BEAM IS CORRODED BETWEEN FRS 58 AND 59. C/A-COMPLETE:REPAIRED RT OMEGA BEAM BETWEEN FR.58-59 IAW SRM 53-24-10. C/W D.T CHECKLIST 15-27.SDR REXA2019030500333Angle · crackedANGLE CLIP ON THE I/B SIDE OF LBL 36 AT FS 484 IS CRACKED, IN THE CABIN BELOW THE FLOOR. REMOVED CRACKED ANGLE CLIP IN I/B SIDE OF LBL36 FS 484 AND INSTALLED NEW ANGLE CLIP IAW SRM 51-42-06, 51-42-21, 53-41-43 51-24-36 TR-51-42 AND 601R-53-41-059.SDR IPXA2019032740523Support · crackedINSPECTION TYPE:12Y AVIONICS COMPARTMENT UNDER FLOOR PANEL 121TF WIRE BUNDLE SUPPORT CRACKED FR18-FR19. REMOVED AND REPLACED WIRE BUNDLE SUPPORT IAW 51-40-21.SDR IPXA2019032140338Cap · crackedINSPECTION TYPE:2C RT SIDE UNDERWING BARREL CANTED PANEL CAP IS CRACKED AT STA. 1236.8 AND Z=-100. REPAIRED CRACKED RT SIDE UNDERWING BARREL CANTED PANEL CAP AT STA. 1236.8 AND Z=-100 IAW EA 011-5310-01-A7651 AND EO MD11-5340-71848-A. (MAJOR)SDR R61A201903090302Closeout Panel · corrodedWHILE IN HEAVY CHECK - FORWARD CARGO DOOR TRIM THRESHOLD (CLOSEOUT PANEL) IS CORRODED AND CHAFED AS MARKED. REPLACED THRESHOLD (CLOSEOUT PANEL) WITH NEW AND TOP COATED.SDR R61A201903050297Plate · corrodedWHILE AC WAS IN FOR HVY CK FOUND CORROSION LOCATED ON FWD CARGO DOOR LOWER SILL CLOSING PLATE. MX REPLACED FWD CARGO DOOR LOWER SILL CLOSING PLATE PN 170-67451-001. IAW AMM 20-10-01. AC REMAINS IN YRQ FOR COMPLETION.SDR SWAA2019032030859Baffle · corrodedFORWARD CARGO COMPARTMENT INTERCOSTAL BAFFLE CORRODED BETWEEN BS 500C TO BS 500D, LBL 21. R&R BAFFLE PER DWG & SRM.SDR SWAA2019032030858Support · crackedFORWARD CARGO COMPARTMENT L/H BULKHEAD SUPPORT CRACKED AT BS 500D, LBL 21. R&R SUPPORT IAW SRM & DWG.SDR R61A201903050278Angle · crackedWHILE AC WAS IN FOR HEAVY CHECK FOUND COCKPIT FLOOR STRUCTURE AR FR 12 AND LBL 36 CRACK FOUND. MX REPLACED ANGLE AT FR 12 AND LBL 36 PN 170-13238-001 IAW SRM 51-41-01. AC REMAINS IN YRQ FOR COMPLETION.SDR R61A201903050277Angle · crackedWHILE AC WAS IN FOR HEAVY CHECK COCKPIT FLOOR STRUCTURE AT FR 12 AND BLO ANGLE FOUND CRACKED. MX REPLACED ANGLE PN 170-16131-001 IAW SRM 51-41-01, AC REMAINS IN YRQ FOR COMPLETION.SDR ASAA2019030528658Threshold · corrodedAFT CARGO DOOR THRESHOLD WEB HAS CORROSION IN PREVIOUS BLENDOUT. GROUNDED - YES. REMOVED CORROSION IAW SRM 53-60-15. ORIG THICKNESS 0.050 REMOVED 0.012 REMAINING MAT 0.038 FOUND TO BE OUT OF LIMITS IAW SRM 53-60-15. TOOL #T82250. REMOVED WEB IAW SRM 51-40-02. SDR RAIA201903050002Angle · corrodedCARGO DOOR LOWER THRESHOLD 'Z' ANGLE HAS CORROSION AROUND NUTPLATE HOLES AND FASTENERS. REMOVED CARGO DOOR LOWER "Z" ANGLE THRESHOLD ON FUSELAGE. DRILLED NEW "Z" ANGLE HOLES FOR LOWER CARGO DOOR FUSELAGE THRESHOLD. INSTALLED LOWER CARGO DOOR FUSELAGE THRESHOLDSDR RAIA201903050003Attach Angle · bentCARGO DOOR LOWER THRESHOLD 'T' PROFILE AT FR 66 BENT. REMOVED CARGO RAMP 'T' PROFILE, LOWER ATTACH ANGLE. R/R THE UPPER RAMP ANGLE ATTACH AT FR 66. REPLACED "T" PROFILE, LOWER ATTACH ANGLE & PLATE FOR CARGO RAMP ON FR66.SDR REXA2019030500279Receptacle · crackedINITIAL INSPECTION: CRACK IN BOX AT A/C EXTERNAL POWER RECEPTACLE SURROUND STRUCTURE. (FUS) SUMMARY: BOX AT A/C EXTERNAL POWER RECEPTACLE SURROUND STRUCTURE WAS REPLACED FOR A NEW ONE (P/N: CC670-33401-3) PER SRM 51-42-06-001-001-A01.SDR SWAA2019031530709Baffle · crackedFLOOR TO SIDEWALL SUPPORT BAFFLE CRACKED BETWEEN BS 727A TO BS 727B, LBL 21. R&R BAFFLE IAW SRM & DWG.SDR SWAA2019031530684Strap · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE CROSS BEAM STRAP CORRODED AT FASTENER HOLES AT BS 767D+5. R&R STRAP PER SRM.SDR SWAA2019031330627Intercostal · crackedINTERCOSTAL CRACKED BETWEEN BS 294.5 TO BS 312, LBL 11. R&R INTERCOSTAL PER SRM.SDR SWAA2019031230547Threshold · corrodedAFT CARGO LOWER MAIN THRESHOLD WEB CORRODED BETWEEN BS 807 TO BS 847. R&R WEB PER SRM.SDR DALA2019030601582Stiffener · crackedSHIP 6803 CRACK INDICATION NOTED ON 1 EA FASTENER HOLE STA 700 LBL 24 TOP FLOOR STIFFENER HOLE. CORRECTIVE ACTION: CUT OUT DAMAGED SECTION 1.2"X.9" AND REPAIRED STA 700 LBL 24 FLOOR STIFFENER HOLE IAW ER/A # 575613-14 REV ORIGINAL. (0970844)SDR SIMA20190305006Channel · corrodedSERVICE DOOR CENTER SILL CORRODED AT FORWARD AND AFT ENDS. C/A-REMOVED AND REPLACED SERVICE DOOR CENTER SILL IAW SRM 51-40-02.SDR A6WA2019030746454Door Sill · corrodedLT PRESSURE FLOOR SILL IS CORRODED AT F.S.449.85.SDR AALA201903065004Floor Support · corrodedCORROSION FOUND ON THE AFT GALLEY FLOOR SUPPORT, BS 947 - 967, LBL 25. REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02.SDR DALA2019030500064Floor Support · corrodedDURING M CHECK, BULK CARGO COMPARTMENT RIGHT FLOOR SUPPORT ASSEMBLY AT FR 67-69-45 FOUND CORRODED. REPLACED CORRODED SUPPORT PER SRM 51-42-11-001 AND DRAWING F53972225. LP 0970459SDR SWAA2022030497971Floorbeam · corroded***CORROSION*** ON 986.5 FLOOR BEAM UPPER SURFACE; AROUND FASTENER HOLES; R.B.L 40-43; W.L. 208.1. / REPAIRED BS 986.5 FLOOR BEAM UPPER SURFACE CORROSION RBL 40-43; WL 208-1 PER EA 1-A53-8241 REV 3 AND EA 1-753-34414 REV IR.
Back to JASC 5320