JASC 5320
Service difficulty reports · 216,415
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2019031430645Shield · corrodedFORWARD CARGO FOUND SHIELD CORRODED AT BS 432, RBL 21. R&R SHIELD IAW SRM AND DWG.SDR SWAA2019030830454Intercostal · crackedFORWARD GALLEY AREA INTERCOSTAL CRACKED BETWEEN BS 294.5 TO BS 312, RBL 15. R&R INTERCOSTAL PER SRM & DWG.SDR SWAA2019030830453Intercostal · crackedINTERCOSTAL CRACKED BETWEEN BS 312 TO BS 328, RBL 30. R&R INTERCOSTAL IAW SRM & DWG.SDR SIMA20190227005Floor Support · corrodedLT OMEGA BEAM HAS POSSIBLE CORROSION ABOVE THE CROSSBEAM AT FRAME 44. C/A-REPAIRED THE LT OMEGA BEAM CORROSION ABOVE THE CROSSBEAM AT FRAME 44 IAW ERS-EM-53MR-3679.SDR SWAA2019030730435Support · corrodedAFT CARGO BAY ON LT FLOOR TO SIDEWALL SUPPORT CORRODED BETWEEN BS 727C+8 TO BS 847, LBL 22. R&R SUPPORT IAW SRM AND DWG.SDR SWAA2019030630373Intercostal · crackedFORWARD CARGO INTERCOSTAL CRACKED BETWEEN BS 500B TO BS 500C, RBL 24. R&R INTERCOSTAL PER SRM & DWG.SDR RAIA201902270002Door Sill · corrodedLT FLOOR SIDEWALL SILL FROM FRAMES 29-35 HAS SIGNS OF CORROSION. REMOVED AND REPLACED LT FLOOR SILL FROM FRAMES 29-35.SDR AALA201903068005Transition Panel · corrodedCORROSION ON THE AFT CARGO LEFT TRANSITION PANEL BETWEEN BS 727 AND 847. REPLACED THE TRANSITION PANEL IAW SRM 53-00-53-2R, AND SRM 51-10-02.SDR RAIA201902270001Door Sill · corrodedRT FLOOR SILL FROM FRAMES 29-35 HAS SIGNS OF CORROSION. REMOVED AND REPLAXCED RT FLOOR SILL FROM FRAMES 29-35.SDR SWAA2019030530225Channel · corrodedAFT PIT LOWER LT ZEE CHANNEL CORRODED BETWEEN BS 727D TO BS 847. R&R ZEE CHANNEL IAW SRM.SDR CALA2019030100321Door Sill · corroded(A3NB-53-4-6179) AFT CARGO DOOR SILL AREAS OF CORROSION FR58. REFER TO N/R: 9022350. REPAIRED AFT CARGO DOOR SILL IAW EC/RA 5341-01156. REPAIR CONCID ERED PERMANENT WITH NO FURTHER ACTION REQUIRED. REFER TO N/R : 9032179. THIS LOGPAGE IS AN SDR REPORTABLE LOGPSDR CALA2019030100320Floor Support · corrodedB737-53-3-0734 FWD CABIN FLOOR PANEL BREAK HAS CORROSION BETWEEN FLOORBEAMS 312 AND 328 RBL 12 MKD 126-041 REMOVED AND REPLACED FLOOR PANEL BREAK AT FWD CABIN BETWEEN FLOORBEAMS 312 AND 328 RBL 12 AS PER SRM 51-40-02 REF NR 9583863.SDR CALA2019030100319Floor Support · corrodedB737-53-3-0734 FWD CABIN FLOOR PANEL BREAK HAS CORROSION BTW FLOORBEAMS 312 AND 294.3 RBL 12 MKD 126-040. REMOVED AND REPLACED FLOOR BREAK AT RBL 12 FLOORBEAMS 312 AND 294.3 AS PER SRM 51-40-02 REF NR 9583862.SDR CALA2019030100318Web · crackedUPON REMOVAL OF FWD CARGO RH FLOOR STRUCTURE ZEE CHANNEL IT WAS FOUND THAT SEVERAL WEBS WERE CRACKED BETWEEN BS 500A - 500B, 500D - 500E, 500E - 500F, 500F - 500G, 500G -500H AND 500H -500I TOTAL OF 6 WEBS NEED TO BE REPLACED. REMOVED AND REPLACED NEW BAFFLE ASDR CALA2019030100317Intercostal · crackedB737-53-3-0734 FWD CABIN FLOOR SUPPORT INTERCOSTAL CRACKED TWO PLACES BETWEEN BS 360 AND 344 RBL 5 MKD 126-045 REMOVED AND REPLACED FWD CABIN FLOOR SUPPORT INTERCOSTAL AT BS360 AND 344RBL5 IAW SRM 51-40-02 AND SRM 51-40-05. PO # 1591023 INTERCOSTAL REF NR 9588SDR CALA2019030100315Intercostal · crackedRT FR 16 DOOR STOP FITTING NUMBER ONE BOTTOM FITTING, LOWER I/B FASTNER HOLE HAS CRACK INDICATION. N/R 9022068. REMOVED AND REPLACED INTERCOSTAL ON R/H FR 16 DOOR STOP FITTING NUMBER ONE LOCATION BETWEEN FR 15-FR16 IAW SRM 51-72-11-911 -001.SDR CALA2019030100311Floor Support · crackedB737-53-3-0734 FWD CABIN FLOOR SUPPORT INTERCOSTAL CRACKED BTW FLOOR BEAMS 312 AND 328 RBL 31 MKD 126-039 REMOVED AND REPLACED FLOOR SUPPORT INTERCOSTAL 312 & 328 RBL 31 MKD 126-039 IAW SRM 51-40-02 REF NR 9583861.SDR CALA2019030100307Gusset · damagedRT INNER CAP JOINT-GUSSETS FRAME 68 STRINGER 12 2ND HOLE FROM TO P, #2, HAS REJECTABLE INDICATIONS A3NB-53-4-6355 AD 2015-05-02 P ER LCQ NR 9298204 UPON FURTHER EVALUATION OF GUSSET HOLES 1EA HOLE @FR68 STR 12R G OUND TO BE DAMAGED REAMED HOLE TO @ DIA OF 0.21SDR AALA201903018007Transition Panel · corrodedCORROSION FOUND ON THE AFT CARGO, RIGHT TRANSITION PANEL, BS 727 - 787. REPLACED THE TRANSITION PANEL IAW RD 51-00-05, AND SRM 53-00-53-1A.SDR DALA2019022801299Support Angle · corroded(LOG 0962711) DURING INSPECTION FOUND CORROSION SUPPORT ZEE BTW BS 727G TO BS 807 AND STR 25L AT AFT CARGO COMPARTMENT. REPLACED SUPPORT ZEE BTW BS 727G TO BS 847 AT LEVEL STR 25L AND REPAIR BTW. 787 TO BS 807 ASPER SRM 51-10-02 SRM 53-00-53 REPAIR 6 FIG.203 ASDR DALA2019022801298Angle · cracked(LOG 0962615) DURING INSPECTION FOUND CRACK ANGLE-CLIP BS 400 AND STR 26R AT FWD CARGO COMPARTMENT. REPLACED ANGLE-CLIP BS400 AND STR 26R AT FWD CARGO COMPARTMENT AS PER SRM 51-10-02 ITEM 9 AND SRM 51-40-02 AND DWG 143A7505 REV B.SDR DALA2019022801297Intercostal · corroded(LOG 0962609) DURING INPSECTION FOUND CORROSION WEB - INTERCOSTAL BTW BS 767 TO BS 787 AND STR 25R AT AFT CARGO COMPARTMENT. REPLACED WEB-INTERCOSTAL LOC BTW BS767 TO BS787 AND STR 25R AT AFT CARGO COMPARTMENT ASPER DWG 146A0081 REV A. AND SRM 51-10-02.SDR DALA2019022801295Tie Clip · cracked(LOG 0962540) DURING INSPECTION FOUND CRACK TIE CLIP BS 500I AND STR 26L AT FWD CARGO COMPARTMENT. REPLACED TIE CLIP LOCATED BS 500I AND STR 26L AT FWD CARGO COMPARTMENT ASPER SRM 51-10-02 ITEM 9 DWG #143A-1234 REV A.SDR DALA2019022801294Intercostal · cracked(LOG 0962486) DURING INSPECTION FOUND CRACK WEB-INTERCOSTAL BTW BS 500C TO BS 500D AT LEVEL S-26R AT FWD CARGO COMPARTMENT. REPLACED WEB INTERCOSTAL BTW BS 500C TO BS 500D AT LEVEL STR 26R AT FWD CARGO COMPARTMENT ASPER SRM 51-10-02 ITEM 9 DWG # REV A.SDR DALA2019022801278Floor Support · crackedCRACK FLOOR SUPPORT BTW STA Y=636 AND BELOW TIE TRACK LH AT FWD CARGO COMPARTMENT (CCD). NRC 00336: CRACK FLOOR SUPPORT STA Y=636 AT FWD CARGO COMPARTMENT WAS REPLACED PER B717-200 SRM 51-41-02-0G. (LP #0962962)SDR DALA2019022801277Support · crackedCRACKED FWD SUPPORT BTW BEAM 5 AND PAN AT AFT CARGO COMPARTMENT DOOR. NRC 00195: FWD SUPPORT BTW BEAM 5 AND PAN AT AFT CARGO COMPARTMENT DOOR WAS REPLACED PER B717-200 SRM 51-41-01-0G AND 51-41-05-0G. (LP #0962888)SDR SWAA2022022572347Intercostal · crackedFOUND INTERCOSTAL CRACKED IN FWD. GALLEY AREA AT LOCATION 15 RBL BETWEEN STA 294.5 AND STA 312 / DEFECT TRANSFERRED TO NON ROUTINE CARD # T918557SDR SWAA2019042431954Floor Support · crackedINTERCOSTAL CRACKED FROM BS 344-360, LBL 11, WL 208. REMOVED AND REPLACED INTERCOSTAL IAW SRM-SDR SWAA2019042431953Floor Support · crackedINTERCOSTAL CRACKED FROM BS 344-360, BL 0, WL 208. REMOVED AND REPLACED INTERCOSTAL PER SRM.SDR COEA201904168913Channel · corrodedNR 12 POST HEAVY CHECK INSPECTION, R/H FORWARD LOWER SIDE BOX SPLICE CHANNEL HAS LEVEL 2 CORROSION AT MLG ACTUATOR FITTING LOWER FORWARD BOLT HOLE. REPLACED CHANNEL SPLICE WITH A NEW PART.SDR COEA201904166913Channel · corrodedWO 195308 NR 12 POST HEAVY CHECK INSPECTION COE/MAJOR REPAIR: R/H FORWARD LOWER SIDE BOX CHANNEL HAS LEVEL 2 CORROSION AT MLG ACTUATOR FITTING LOWER FORWARD BOLT HOLE. CORRECTIVE ACTION: REPAIRED PER SRAS ES-0094228-01...14279 ISSUE A, DATED APRIL 12, 2019.SDR SWIA201904125748Plate · corrodedCORROSION FOUND ON SERVICE DOOR FLOOR PROTECTOR PLATE. (C-CHECK) RO: 04/11/2019 REMOVED AND REPLACED SERVICE DOOR PROTECTOR PLATE, IAW SRM.SDR SWAA2019032831134Structure · corrodedL1 DOOR CUTOUT LOWER INNER CHORD CORRODED BETWEEN BS 312 TO BS 344, LBL 54. R&R CHORD IAW SRM AND DWG.SDR SWAA2019031430665Shear Web · crackedLT SHEAR WEB CRACKED UNDER L2 CREASE BEAM, BS 986. R&R SHEAR WEB IAW DWG.SDR SIMA20190226006Channel · crackedRT HAT BEAM INBD AND OTBD SUPPORTS ARE CRACKED FWD OF FR 48. C/A-REMOVED AND REPLACED RT HAT BEAM INBD AND OTBD SUPPORTS IAW SRM 53-23-02. ANGLE P/N 145-28364-005.SDR SWAA2019030830466Intercostal · crackedINTERCOSTAL CRACKED BETWEEN BS 328 TO BS 344, LBL 45. R&R INTERCOSTAL IAW SRM & DWG.SDR SWAA2019030830465Intercostal · crackedINTERCOSTAL CRACKED BETWEEN BS 312 TO BS 328, LBL 45. R&R INTERCOSTAL IAW SRM & DWG.SDR SWAA2019030830464Intercostal · crackedINTERCOSTAL CRACKED BETWEEN BS 312 TO BS 328, RBL 30. R&R INTERCOSTAL IAW SRM & DWG.SDR SWAA2019030830463Intercostal · crackedINTERCOSTAL CRACKED BETWEEN BS 277 TO BS 294.5, BL 0. R&R INTERCOSTAL IAW SRM & DWG.SDR SIMA20190226005Floor Support · corrodedLT OMEGA BEAM FLOOR SUPPORT CORRODED BETWEEN FR58 ? 59; LT OMEGA BEAM CORRODED ON LOWER FLANGE AND WEB UNDER CROSSBEAM AT FR 59. C/A-REPAIRED THE LT OMEGA BEAM FLOOR SUPPORT CORROSION BETWEEN FR58-59, AND LOWER FLANGE AND WEB UNDER CROSS BEAM AT FR 59 IAW ERS-SDR AALA2019030769024Shear Panel · corrodedCORROSION FOUND ON THE AFT CABIN WET AREA FLOOR CENTER SHEAR PANEL BETWEEN FRAMES 87 - 88, -Y380 & +Y380. REPLACED THE SHEAR PANEL IAW RD 53-00-00-3.SDR AALA2019030769021Web · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION FOUND ON THE FORWARD MAIN CABIN LEFT FLOOR WEB BETWEEN FRAMES 12 - 13, -Y373. REPLACED THE WEB IAW RD 53-10-00-2.SDR AALA2019030769020Floor Support · corrodedCORROSION FOUND ON THE AFT CABIN WET AREA FLOOR SUPPORT AT FRAME 87, -Y762. REPLACED THE FLOOR SUPPORT IAW SRM 51-43-01.SDR AALA2019030769017Shear Panel · corrodedCORROSION FOUND ON AFT CABIN WET AREA SHEAR PANEL, FRAMES 87 - 88, +Y584 - +Y914. REPLACED THE SHEAR PANEL IAW RD 53-00-00-3.SDR SWAA2019030630237Attach Angle · corrodedAFT CARGO BAY WEB ATTACH ANGLE CORRODED BETWEEN BS 767 TO BS 787, RBL 21. R&R ANGLE PER SRM & DWG.SDR SWAA2019030530313Gusset · crackedFORWARD CARGO BAY GUSSET CRACKED AT BS 500D, STR 19L. R&R GUSSET IAW SRM & DWG.SDR SWAA2019030530307Shield · crackedAFT CARGO BAY ANGLE UNDER THE SHIELD CRACKED BETWEEN AT BS 767 TO BS 787, RBL 22. R&R SHIELD IAW SRM AND DOCUMENT.SDR R61A201902260233Structure · corrodedDURING HEAVY CHECK MAINTENANCE FOUND AFTER REMOVAL OF COPILOT'S INBOARD SEAT TRACK RAIL FOR SN 0086, FOUND CORROSION ON UNDERLYING
FLOOR STRUCTURE FROM FR 9 TO FR 10. REPAIRED CO-PILOT'S INBOARD SEAT TRACK RAIL UNDERLYING FLOOR STRUCTURE FROM FR9 TO FR10 REF.SDR DALA2019022701356Intercostal · corrodedSHIP 6706 CORROSION ON LOWER SILL INTERCOSTAL STA 1663 AND LBL 52 AT AFT WET AREA. CORRECTIVE ACTION: SUMMARY OF NRC00301. SUPPORT WAS REPLACED PER SRM AND DWG REV.A. (0960667)SDR DALA2019022701293Intercostal · dented(LOG 0961296) DURING INSPECTION FOUND DENT WEB - INTERCOSTAL BTW BS 500B TO BS 500C AND STR 26L AT FWD CARGO COMPARTMENT. REPLACED WEB-INTERCOSTAL BTW BS 500B TO BS 500C AND STR 26L AT FWD CARGO COMPARTMENT ASPER SRM 51-10-02 ITEM 9 51-40-02 AND DWG #143A7505
Back to JASC 5320