JASC 5320
Service difficulty reports · 216,095
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2025121809218Web · corrodedSHIP 3161 CORROSION WEB LOCATED BETWEEN FR20 AND STR23R FWD GALLEY AREA. CORRECTIVE ACTION: REPLACED WEB LOCATED BETWEEN FR20 TO FR24 AND AT LEVEL STR23R FWD GALLEY AREA AS PER A319 SRM 51-72-11. (1356222).SDR REXA2026052600674Fitting · corrodedCORROSION FLOOR FITTING ACCESS 305 (1EA) AISLE SIDE ON GALLEY 3 FLOOR FITTING ON ACCESS 305 (1 EA) AISLE SIDE AT GALLEY 3 WAS REPLACED PER C&D ZODIAC AEROSPACE CMM 25-33-18SDR REXA2026052600673Fitting · corrodedCORROSION FLOOR FITTING ACCESS 109 (1EA) ON GALLEY 1 FLOOR FITTING ON ACCESS 109 (1 EA) AT GALLEY 1 WAS REPLACED PER SAFRAN CMM 25-33-67SDR SWIA2026031875547Floor Support · corrodedCORROSION NOTED ON FLOOR SUPPORT LBL 9 FROM BS 409 TO 409+128 IN MULTIPLE LOCATIONS. REPAIRED THE FLOOR SUPPORT BY REPLACING IAW REO 601R-53-31-1362, REV -, AND SRM 53-00-43.SDR SWAA2026012853009Angle · crackedCRACKED ANGLE, BS 400, LBL 21, IN THE FWD CARGO BAY. REPLACED THE ANGLE IAW SRM 51-10-02, ITEM 9, SRM 51-40-02, & DWG 143A7505,SHEET 137, REV-.SDR SWAA2026012853010Angle · crackedCRACKED ANGLE, BS 500H, LBL 21 IN THE FWD CARGO BAY. REPLACED THE ANGLE & FASTENERS IAW SRM 51-40-02, DWG 143A7505, SHEET 138, REV -.SDR SWAA2026012853011Angle · crackedCRACKED ANGLE, BS 440, LBL 21. IN THE CARGO BAY. REPLACED THE ANGLE IAW SRM 51-40-02-0G-0, & DWG 143A7505, SHEET 138, REV -.SDR SWAA2026012853013Angle · crackedCRACKED ANGLE, BS 500G, RBL 21, IN THE CARGO BAY. REPLACED THE ANGLE & FASTENERS IAW SRM 51-40-02-0G-0, & DWG 143A7505, SHEET 137, REV-.SDR SWAA2026012853016Angle · crackedCRACKED ANGLE, BS 500G, RBL 21 AFT SIDE FWD CARGO BAY. REPLACED THE ANGLE IAW SRM 51-10-02-0G-0, ITEM 9, & DWG 143A7505, SHEET 137, 138, & 139, REV-.SDR SWAA2026012853014Gusset Angle · crackedCRACKED GUSSET ANGLE, BS 500I, S19R. REPLACED THE GUSSET & FASTENERS IAW SRM 51-40-02-0G-0, SRM 51-10-02-0G-0, ITEM 9, & DWG 143A7902, SHEET 256, REV B.SDR SWAA2026012753015Angle · crackedCRACKED ANGLE, BS 500H, RBL 21 FWD SIDE IN THE FWD CARGO BAY. REPLACED THE ANGLE & FASTENERS IAW SRM 51-40-02-0G-0, & DWG 143A7505, SHEET 137, REV-.SDR SWAA2026012753012Angle · crackedCRACKED ANGLE, BS 500H, RBL 21 AFT SIDE IN THEFWD CARGO BAY. REPLACED THE ANGLE AND FASTENERS IAW SRM 51-10-02-0G, SRM 51-40-02-0G-0, & DWG 143A7505, SHEET 137, REV-.SDR SWAA2026012652972Angle · crackedCRACK INNER ANGLE LOCATED BS 303.9, LBL 55 FWD GALLEY AND LAVATORY. REPLACED THE ANGLE BTWN BS 270 - 360, LBL 55, WL 208.1 IAW SRM 51-40-02-0G-0, DWG 142A0050, SHEET 15, REV-.SDR SWAA2026012652955Floor Support · corrodedCORRODED FLOOR SUPPORT, BTW BS 328 - 344, LBL 45.5, WL 208.1 IN FWD GALLEY AREA. REPLACED FLOOR SUPPORT IAW SRM 51-40-02 AND SRM 51-10-02-0G-0, ITEM 9, DWG 141A5730, SHEET 30, REV A.SDR SWAA2026012652971Floor Support · corrodedCORRODED FLOOR SUPPORT BTW BS 328 - 344, LBL 24.75, WL 208.1. REPLACED FLOOR SUPPORT IAW SRM 51-40-02 AND DWG 141A5730, SHEET 30, REV A.SDR SWAA2026012352973Web · crackedCRACKED WEB - INTERCOSTAL FLOOR STRUCTURE BTW BS 312 TO 328, LBL 46. REPLACED THE WEB - INTERCOSTAL AND FASTENERS IAW SRM 51-40-02, AND DWG 141A5400, SHEET 26, REV -.SDR SWAA2026012252974Angle · crackedCRACKED ANGLE, BTW BS 291 & 294, RBL 53, IN THE FWD GALLEY. REPLACED THE ANGLE IAW SRM 51-10-02, ITEM 9, SRM 51-40-02, & DWG 141A8310, SHEET 33, REV-.SDR SWAA2026012252946Floor Support · corrodedCORRODED INTERCOSTAL, BTW BS 947.5 - 967, RBL 43, WL 208.1 IN THE AFT GALLEY. REPLACED THE INTERCOSTAL IAW SRM 51-40-02-0G, SRM-51-10-02-0G-0, ITEM 9, & DWG 147A5650, SHEET 71, REV A.SDR AALA202601153652Intercostal · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CARGO FLOOR SUPPORT AT BS 867 AT S25L. REPLACED THE FLOOR SUPPORT IAW AARD 51-00-05-1 AND EA 370720.SDR SWAA2026011453063Floor Support · crackedCRACKED FLOOR SUPPORT, FWD CABIN BS 391, RBL 41, WL 208. REMOVED DAMAGED FLOOR SUPPORT AND INSTALLED A NEW FLOOR SUPPORT IAW SRM 51-40-02, AND DWG 143A5400 REV-.SDR SIMA2026010516003Support · crackedSSI Z700-001 IN NOSE WHEEL WELL, NOSE STEERING MANIFOLD SUPPORT BRACKET CRACKED. REMOVED AND REPLACED NOSE STEERING MANIFOLD SUPPORT BRACKET REF EMB 175 SRM 51-40-08. RESTORED FINISH TO FASTENERS REF EMB 175 SRM 51-23-06, CPM 51-25-00, AND ENVOY ETN-EJ-51-015.SDR SWAA2025123052676Threshold · crackedFORWARD CARGO BAY FORWARD CORNER THRESHOLD IS CRACKED. REPAIRED FORWARD CARGO BAY FORWARD CORNER THRESHOLD IAW SRM 53-30-15-2R-1.SDR VNAA20251216021Rivet · corrodedCORROSION ON SEVERAL SHOP FORMED HEAD OF RIVETS INSTALLED ON OUTER CHORD AT INTERIOR SIDE OF FS1098.20 BTW STGR 24LH-24RH. RIVETS ON OUTER CHORD AT INTERIOR SIDE OF FS1098.20 BTW STGR 24LH-24RH WERE REPLACED PER CRJ-900 SRM 51-42-06-001-001-A01SDR VNAA20251216020Strap · corrodedCORROSION AT SUPPORT STRUCTURE STRAP BTW FAIRING ACCESS PANEL 193AR TO FAIRING ACCESS PANEL 193AB. EVALUATED PER EXCESSIVE DAMAGE PER CRJ-900 SRM 53-00-00-101-001-A01 AND REPLACED PER CRJ-900 SRM 51-42-10-001-001-A01 AND SRM 51-42-06-001-001-A01SDR VNAA20251216008Plate · corrodedCORROSION ON KICKPLATE ON INTERNAL SURROUND STRUCTURE BTW FS 310 TO FS349. EVALUATED, DUE TO EXCESSIVE DAMAGE PER CRJ/900 SRM 53-00-00-101-001-A01 AND REPLACED PER SRM 51-42-06-001-001-A01SDR VNAA202512186004Floor Support · crackedCRACKED FLOOR SUPPORT, RBL 12, BTW BS 221.73 - 229. THE FLOOR SUPPORT WAS REPAIRED IAW REO 690-53-11-2087, REV -.SDR VNAA202512186003Web · crackedCRACK ON ELECTRICAL BAY FLOOR WEB, RT SIDE. BELOW ADG SUPPORT DOUBLER, BS 193. THE FLOOR WEB WAS REPAIRED IAW REO 670-53-11-509, REV E, & REO 690-53-11-2093, REV -.SDR CALA2025121812210Shear Web · damagedMAIN CABIN SHEAR WEB AFT OF L2 DOORWAY AT BS 986 - 1016, LBL 32 HAD MULTIPLE ELONGATED FASTENER HOLES. THE SHEAR WEB TO BE INSTALLED ON GSO NRC 9288447 LOCATED AND DRILLED IAW SRM 51-40-05-0G-0.SDR CALA2025121812204Floor Support · corrodedMAIN CABIN FLOOR SUPPORT, LBL 44 BETWEEN BS 328 - 344 WAS CORRODED ON UPPER SURFACE JUST IN FRONT OF SEAT TRACK. R & R THE FLOOR SUPPORT IAW DWG 141A5730, REV A.SDR DALA2025121709189Bracket · damagedTOOLING DAMAGE ON BRACKET - LT AFT SIDE FR 62 STRINGER P4. REPAIRED PER ERA 628320-14 REV. ORIG. (1354549)SDR DALA2025121709188Support Bracket · damagedBS 40.1RT I/B LOWER RIVET ON SUPPORT BRACKET HEAD HAS TOOLING DAMAGE. REPAIRED PER ERA 628320-14 REV. ORIG. (1354896)SDR SWIA2025121577771Floor Support · damagedDAMAGE TO PRESSURE FLOOR SUPPORT AT BS 461.5, LBL 41, COMPLIED WITH A PERMANENT REPAIR ON LT PRESSURE FLOOR SUPPORT IAW REO 601R-53-41-3468, REV-. COMPLIED WITH ALL STEPS OF TASK CARD 51-90-1003-SKY.SDR REXA2026052600657Support Angle · crackedOUT OF SCOPE: CRACKED INTERNAL ANGLE OF EXTERNAL POWER RECEPTACLE SUPPORT STRUCTURE. INTERNAL ANGLE OF EXTERNAL POWER RECEPTACLE SUPPORT STRUCTURE WAS REPLACED PER CRJ-900 SRM 51-42-10-001-001-A01 AND CRJ900 SRM 51-42-06-001-001-A01.SDR SWAA2026012752633Scuff Plate · crackedCRACKED SCUFF PLATE AFT CORNER IN THE FWD CARGO BAY. REPAIRED THE SCUFF PLATE IAW SRM 53-30-15-2R-1, REPAIR 1, PARAGRAPH 4. B, STEPS 2 & 4 - 7.SDR SWAA2026012752637Strap · corrodedCORRODED FLOOR STRAP, AFT POSITION BULKHEAD IN THE FWD CARGO BAY. REPLACED THE FLOOR STRAP IAW SRM 51-40-02-0G-0.SDR HNAA2026012300080Gusset · corrodedCENTER GUSSET CORRODED AT BTW FR 59-61. R & R THE GUSSET IAW SRM 51-40-02SDR SWAA2026012252745Support Angle · crackedCRACKED SUPPORT ANGLE, BS 695, BL 0, WL 208.1. REPLACED THE SUPPORT ANGLE IAW SRM 51-10-02, ITEM 9, SRM 51-40-02, AND DWG 273A9110, SHEET 6, REV A. .SDR SWAA2026012252757Scuff Plate · crackedCRACK ON FWD CORNER SCUFF PLATE IN THE AFT CARGO BAY. REPAIRED THE SCUFF PLATE IAW SRM 53-60-15-2R-1, REPAIR 1, PARAGRAPH 4. B, STEPS 2 TO 7, FIGURE 203.SDR SWAA2026011452583Stiffener · crackedWHILE ACCESSING FOR VAPOR BARRIER FOUND STIFFENER AT BS 663, LBL 27, WL 146 CRACKED. REMOVED AND REPLACED THE STIFFENER IAW SRM 51-40-02, DWG 111A1000, REV A, & DWG 149A7210, REV-.SDR DALA2025121609166Support Bracket · damagedTOOLING DAMAGE ON SUPPORT BRACKET FRAME C26.2, LT. REPAIRED PER ERA 628320-14. (1352490)SDR SWAA2026010852211Angle · debondedAFT CARGO LT TRANSITION ANGLE FROM STA 727I TO 787 HAVE 4 DISBONDED NUTPLATES. REMOVED AND REPLACED THE 4 NUTPLATES ON AFT CARGO LT TRANSITION ANGLE FROM BS 727I - 787 IAW SRM 51-40-10. ACCOMPLISHED PUSH PULL TEST IAW SRM-51-40-10.SDR SWAA2026010852212Angle · debondedAFT CARGO RT FLOOR TRANSITION ANGLE FROM BS 727I - 787 HAD 9 DISBONDED NUTPLATES. REMOVED AND REPLACED AFT CARGO RT TRANSITION ANGLE FROM BS 727I - 787 NUTPLATES IAW SRM 51-40-10. ACCOMPLISHED PUSH PULL TEST IAW SRM-51-40-10.SDR AALA202601051422Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK SHEAR PLATE STR 23 R LOC. BTW FR69 AND FR70 AT AFT GALLEY AREA. L=1.250 INCH. MAINTENANCE REPLACED SHEAR PLATE STR 23 R LOC. BTW FR69 AND FR70 AT AFT GALLEY AREA IAW A319 SRM 51-42-11-801, A319 SRM 51-72-11-911-001 AND DWG DSDR AALA202601054084Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK SHEAR PLATE STR 23 L LOC. BTW FR69 AND FR70 AT AFT GALLEY AREA. L= 1.200 INCH. MAINTENANCE REPLACED SHEAR PLATE STR 23 L LOC. BTW FR69 AND FR70 AT AFT GALLEY AREA IAW A319 SRM 51-42-11-801, A319 SRM 51-72-11-911-001 AND DWGSDR JJBA20260211020Floorbeam · corrodedCORROSION FOUND ON FLOOR BEAM CROSS SUPPORT STRUCTURE AT FR 24, BETWEEN CENTER OMEGA BEAMS. REMOVED AND REPLACED THE FLOOR BEAM CROSS SUPPORT STRUCTURE AT FR24 BETWEEN CENTER OMEGA BEAMSSDR HNAA2026012200060Threshold · corrodedPAX DOOR THRESHOLD ATTACHMENT HAS CORROSION AROUND THE NUTPLATE HOLES. R & R THE PAX DOOR AFT AND FWD THRESHOLD ATTACHMENTS IAW SRM 51-40-02.SDR CALA2025122212292Fitting · crackedL2 DOOR CUTOUT, FWD FRAME, MECHANISM, SUPPORT STRUCTURE IS CRACKED. REMOVED AND REPLACED FITTING ON L2 DOOR FWD CUTOUT FRAME BS 684 -692.38. IAW SRM 51-40-02-0G, DWG 143N8375.SDR ASAA2025121363118Floor Panel · damagedAFT WET AREA CABIN FLOOR PANEL P/N 147A5810-28 (STA 986 SIDE) REQUIRES REPAIRED (PLUG OF DELETE HOLES) MARKED WITH TAPE. GROUNDED - YES. ACCOMPLISHED PERMANENT REPAIR TO AFT WET AREA CABIN FLOOR PANEL P/N 147A5810-28 IAW ASA B737-800 SRM 53-70-50-2R-0, 53-00-5SDR CALA2025121512121Angle · crackedRH AFT TI-ANGLE IS CRACKED. REMOVED AND REPLACED TI-ANGLE AT FR42 RH STG 42RH IAW A319 SRM 5 1-72-11-911-001.SDR REXA2026052700762Diaphragm · chafedSECONDARY NRC FROM NRC 00111: AFTER FASTENERS REMOVAL, HIDDEN DAMAGE (WEAR) AROUND HOLES WAS FOUND ON DIAPHRAMG STRINGER 14 ABOVE CATCH PIN SUPPORT BRACKET AT INTERNAL STRUCTURE OF GALLEY SERVICE DOOR. DIAPHRAMG STRINGER 14 ABOVE CATCH PIN SUPPORT BRACKET AT I
Back to JASC 5320