JASC 5320
Service difficulty reports · 216,415
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2019022129899Nut Plate · brokenPASSENGER CABIN FLOOR 222DF GIRT BAR FITTING, MOUNTING NUT PLATES BROKEN. REPAIRED NUTS PLATES IAW SRM.SDR SWAA2019022129888Support · corrodedAFT CARGO BAY WALL SUPPORT CORRODED BETWEEN BS 727 TO BS 767, RBL 22. R&R SUPPORT IAW SRM & DWG.SDR SWAA2019022129885Support Angle · crackedFORWARD CARGO BAY INTERCOSTAL SUPPORT ANGLE CRACKED AT BS 400, LBL 23. R&R SUPPORT ANGLE IAW SRM.SDR SWAA2019022129884Support Angle · crackedFORWARD CARGO BAY INTERCOSTAL SUPPORT ANGLE CRACKED AT BS 500B, LBL 23. R&R ANGLE IAW DWG AND SRM.SDR SWAA2019022129883Shield · corrodedAFT CARGO BAY FLOOR TO SIDEWALL SHIELD CORRODED BETWEEN BS 847 TO BS 867, RBL 22. R&R SHIELD IAW SRM & DWG.SDR SWIA2019022145562Door Sill · corrodedRT FLOOR SILL FS409+73.2 - FS409+128 HAS MULTIPLE AREAS OF CORROSION. (C-CHECK) RO: 02/20/2019 REPAIRED RIGHT FLOOR SILL FS 409+73 TO 409+128 IAW REO.SDR SWAA2019021929746Support · corrodedFLOOR TO SIDEWALL SUPPORT CORRODED BETWEEN BS 767 TO BS 794, RBL 17. R&R SUPPORT IAW SRM AND DWG.SDR SWAA2019021929745Support · corrodedFLOOR TO SIDEWALL SUPPORT CORRODED BETWEEN BS 867 TO BS 887, RBL 17. R&R SUPPORT IAW SRM AND DWG.SDR SWAA2019021929744Support · corrodedFORWARD CARGO RT SIDE FLOOR TO SIDEWALL SUPPORT CORRODED BETWEEN BS 500A TO BS 500D, RBL 25. R&R SUPPORT IAW SRM AND DWG.SDR SWAA2019021929743Support · corrodedFORWARD CARGO, FLOOR TO AFT BULKHEAD SUPPORT CORRODED AT BS 500D, BETWEEN RBL 25 TO LBL 25. R&R SUPPORT IAW SRM AND DWG.SDR SWAA2019021929742Support · corrodedFORWARD CARGO LT SIDE FLOOR TO SIDEWALL SUPPORT CORRODED BETWEEN BS 400 TO BS 500D, LBL 25. REPAIRED SUPPORT IAW SRM AND DWG.SDR R61A201902130172Shear Panel · corroded***WHILE A/C WAS OUT OF SERVICE FOR HEAVY CHECK*** CENTER FUSELAGE III PASSENGER CABIN FLOOR STRUCTURE, CORROSION FOUND AT RH SHEAR PANEL BTW FR87-88. CENTER FUSELAGE III PASSENGER CABIN FLOOR STRUCURE BTW FR87-88, RH SHEAR PANEL REPLACED IAW E-170 SRM 51-42-0SDR SWAA2019021129427Gusset · crackedFORWARD CARGO COMPARTMENT GUSSET CRACKED AT BS 500I, STR 21L. R&R GUSSET IAW SRM & DWG.SDR RAIA201902010003Gusset · corrodedLT LAV FLOOR GUSSET AT FRAME 61 HAS SURFACE CORROSION. REMOVED AND REPLACED LT LAV FLOOR GUSSET AT FRAME 61.SDR RAIA201902010002Gusset · corrodedMID LAV FLOOR GUSSET AT FRAME 61 HAS SURFACE CORROSION. REMOVED AND REPLACED MID LAV FLOOR GUSSET AT FRAME 61.SDR SWAA2019020729341Angle · corrodedFORWARD CARGO COMPARTMENT RT Z ANGLE CORRODED BETWEEN BS 500C+7 TO BS 500I. R&R ANGLE IAW SRM.SDR DALA2019020200789Support · crackedDURING INSPECTION FOUND CRACKED CHANNEL SUPPORT BTW BS 500 TO BS 500A AND STR 26R AT FWD CARGO COMPARTMENT. REPLACED CHANNEL SUPPORT BTW BS500 TO BS 500A AND STR 26R AT FWD CARGO COMPARTMENT AS PER SRM 51-10-02 AND 51-40-02, DWG 143A0080.SDR DALA201902052761Strap · broken(AIRCRAFT 681, L/P 0928354) FWD. CARGO CEILING AREA RH SIDE OUTBD. OF SIDEWALL STANCHION STA. 720, CEILING STRAP BROKEN. CUTOUT DAMAGED SECTION ON FWD CARGO CEILING STRAP STA 720 DIM 2" X 1" IAW B757 SRM 53-00-51 FABRICATED AND INSTALLED REPAIR PARTS IAW B757 SDR AALA201902051002Cusp Web · corrodedCORROSION FOUND ON THE CUSP WEB BETWEEN BS 787 AND 788. REPAIRED THE CUSP WEB IAW SRM 53-05-00.SDR ABXR020190201051Web · corrodedFLC DOOR ENCLOSURE WEB BETWEEN UPPER AND LOWER SILLS CORRODEDSDR ABXR020190201050Door Sill · corrodedFLC DOOR UPPER AND LOWER SILL IS CORRODEDSDR VNAA2019020199911Floor Support · corrodedFLOOR SUPPORT ANGLES AND CUPS AT PAX DOOR SILL ARE CORRODED FROM F.S. 310 TO F.S. 349. C/A: REMOVED AND REPLACED PAX DOOR FLOOR SUPPORT ANGLES AND CUPS REF CRJ 200 SRM 51-42-06, 51-42-13 & 51-42-21.SDR SWAA2022030224027Strip · corrodedFWD CARGO BAY L/H SIDE 3 EACH CAP STRIPS HAVE MULTIPLE AREA'S OF CORROSION AT FASTNER HOLES / IN FWD CARGO BAY REPLACED 3EA CAP STRIPS THAT ARE CORRODED IN MULTIPLE AREAS AROUND FASTNER HOLES. PART NUMBERS 453A1611-6; 453A1611-10 ANBD 453A1611-11 IAW AIPC 25-5SDR C77A2020031700005Panel · corrodedPANEL 192CR HAS CORRODED FLANGE WORK ORDER 2456860672SDR C77A2020031700003Floor Splice · corrodedDURING BASIC CHECK AT EAMS, CORROSION WAS DISCOVERED ON THE P/N 170-12114-001 FLOOR SPLICE IN THE FORWARD WET AREA FLOOR STRUCTURE. REFERENCE ETD2019-170-008053 FIGURE 1 FOR THE DAMAGE LOCATION AND DIMENSIONS. THE DAMAGE LOCATED OVER A FASTENER ROW, AND THEREFSDR C77A2020031700002Panel Support · corrodedDURING BASIC CHECK AT BNA, CORROSION WAS DISCOVERED ON THE P/N 170-92908-001 RH PANEL SUPPORT IN THE AFT WET AREA FLOOR STRUCTURE. REFERENCE FIGURES 1 AND 2 FOR DAMAGE LOCATION AND DETAILS. AFTER CORROSION REMOVAL, THE MATERIAL REDUCTION MEASURED APPROXIMATELYSDR C77A2020031710001Panel Support · corrodedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING FORWARD CABIN FLOOR STRUCTURE: FLOOR DOUBLER P/N 170-12118-001, RH FLOOR SILL P/N 170-05663-003, FR15 FLOOR PANEL SUPPORT P/SDR C77A2020031700039Door Sill · corrodedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING FORWARD CABIN FLOOR STRUCTURE: FLOOR DOUBLER P/N 170-12118-001, RH FLOOR SILL P/N 170-05663-003, FR15 FLOOR PANEL SUPPORT P/SDR C77A2020031700038Doubler · corrodedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING FORWARD CABIN FLOOR STRUCTURE: FLOOR DOUBLER P/N 170-12118-001, RH FLOOR SILL P/N 170-05663-003, FR15 FLOOR PANEL SUPPORT P/SDR REXA2019061831901Drag Angle · crackedLH MLG W/W DRAG ANGLE CRACKED. REMOVED AND REPLACED L/H MLG W/W DRAG ANGLE. IAW CRJ-200 SRM 51-42-21. AAR SM 33SDR REXA201906183900Drag Angle · crackedRH MLG W/W DRAG ANGLE CRACKED. REMOVED AND REPALCED R/H MLG W/W DRAG ANGLE. IAW CRJ-200 SRM 51-42-21. AAR SM 33SDR SWAA2019022830118Support · corrodedFORWARD CARGO BAY LT FLOOR TO SIDEWALL SUPPORT CORRODED BETWEEN BS 500 TO BS 500D, LBL 23. R&R SUPPORT IAW SRM AND DWG.SDR ASAA2019013128181Transition Panel · corrodedAFT CARGO COMPT LT FLOOR TRANSITION PANEL HAS MISSING CLICK BOND NUTPLATES AND CORROSION BETWEEN STA 727L-747. GROUNDED - YES. REMOVED CORROSION IN AFT CARGO COMPT LT FLOOR TRANSITION PANEL FROM STA 727K- STA 747. ORIGINAL THICKNESS IS .040, REMOVED .010, REMASDR AALA201902152001Web · corrodedCORROSION FOUND ON THE AFT CARGO DOOR CUTOUT, LOWER WEB BETWEEN BS 800 AND 840. REPLACED THE WEB IAW RD 51-00-05.SDR SIMA20190212004Angle · crackedR/H HAT BEAM ANGLE IS CRACKED BETWEEN FRS 47 AND 48. -C/A-INSTALLED NEW RH HAT BEAM ANGLE IAW SRM 51-40-02.SDR RAIA201902123101Floor Support · corrodedL/H FLOOR SILL FR 61-65 HAS CORROSION AROUND NUTPLATES- FLOOR SILL FOUND TO BE OUT OF LIMITS. STARTED REMOVING FLOOR SILL. REMOVED THE CARBON RING LOWER TO FOM. REMOVED FLOOR SILL, PROCURED NEW FLOOR SILL. REQUIRE LOCATING HOLES AND INSTALLATION. INSTSDR AALA201902099004Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON SUPPORT AT FR 84, -Y990. REPLACED SUPPORT PER SRM 51-43-06, 51-40-02, 51-75-16.SDR ASAA2019013128091Floor Support · corrodedMAIN CABIN RT FRAME STA 277 THRU 332.1 - FLOOR BOARD SUPPORT STRUCTURE COMMON TO R1 SERVICE DOOR SILL AREA, UPPER SURFACE HAS BARE METAL AREAS AND AREAS OF CORROSION. GROUNDED - YES. BLENDED INNER CHORD AT R-1 DOOR, ORIGINAL MATERIAL .080 MATERIAL REMOVED .012SDR SWAA2019020729378Bracket · crackedFORWARD CARGO COMPARTMENT LT TRANS ANGLE SUPPORT INTERCOSTAL AFT BRACKET CRACKED AT BS 500C. R&R BRACKET PER SRM.SDR AALA201902049031Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON CABIN FLOOR PANEL SUPPORT AT FR 84 BETWEEN +Y304 AND +Y939. REPLACED CABIN FLOOR PANEL SUPPORT PER SRM 51-41-02, 51-41-01 AND 51-42-01.SDR SWAA2019020629274Support · crackedAFT CARGO BAY RT FLOOR TO SIDEWALL SPLICE CRACKED AT BS 887, RBL 21. R&R SUPPORT IAW DWG AND SRM.SDR A6WA2019020646366Angle · crackedFS280, STR 3L I/B AND O/B CLIPS CRACKED. REPLACED CLIPS IAW CRJ 200 SRM 51-42-06, 51-42-21.SDR SWAA2019020529258Shield · crackedAFT CARGO BAY AFT SHIELD CRACKED BETWEEN BS 847 TO BS 867, RBL 21. R&R SHIELD PER SRM AND DWG.SDR CALA2019020100203Floor Support · corrodedREF NR LP 9131321 B767-53-3-6223 CABIN - BS 842-852 LBL 55 FLR BEAM FOUND CORRODED CABIN FLOOR BEAM UPPER CHORD REPAIRED AT BS790 TO BS901 LBL 55 AS PER SRM 53-00-51 REPAIR 3 FIG 201 ATTACHED FORM 44-0008 ITEM 1 TO ITEM 21 ACCOMPLISHED ADD EMP:V897532 INSPECTESDR CALA2019020100202Structure · cracked02MAR HKG CF -L :LH STA 1809 HORIZ INNER CHORD 1 EA FAST FN D CRK AT 8 O''CLK POS RUNNING TO EDGE.AREA REPAIRED PER EA 5312-0 1059 REV B OP9 STEP 1 AND SRM 53-80-08 REP 10 FIG 201 DET II.REP EAT INSPECTION AS PER SRM 53-80-08 REP 10 TBL 202, INSP THRESHOL D ISSDR DALA2019020100658Threshold · corrodedFORWARD CARGO COMPARTMENT: CORROSION AT FWD CARGO DOOR CUT OUT THRESHOLD. (MKD). NRC 001-0229:0593-2007/002 00031 REPLACED DOOR JAMB SECTION REF B717 SRM 53-20-15-2R REPAIR 6. (LP #0926097)SDR DALA2019020100655Cusp Web · crackedCRACKS ON CUSP-MEMBRANE RH SIDE BETWEEN STA 579-589. (CPAX). NRC 00241: CUSP-MEMBRANE RH SIDE BETWEEN STA 579-589 WAS REPLACED PER B717-200 SRM 51-41-02-0G. (LP #0926077)SDR KCSA201901311021Intercostal · crackedOVERWING INTERCOSTAL WEB IS CRACKED (1 1/4") AT STATION 1180 RBL 112 WL 186.SDR KCSA201901311020Intercostal · crackedOVERWING INTERCOSTAL WEB IS CRACKED (1 1/2") AT STATION 1180 LBL 112 WL 186.SDR KCSA201901311019Intercostal · crackedOVERWING INTERCOSTAL WEB IS CRACKED (2") AT STATION 1220 RBL 112 WL 186.
Back to JASC 5320