SDR SWAA2019020629355Intercostal · crackedINTERCOSTAL CRACKED BETWEEN BS 380 TO BS 400, RBL 0. R&R INTERCOSTAL PER SRM.SDR SWAA2019020629352Intercostal · crackedINTERCOSTAL CRACKED AT BS 540, BETWEEN RBL 24.5 TO RBL 45.5. R&R INTERCOSTAL PER SRM.SDR AALA201902019020Door Sill · corrodedCORROSION FOUND ON THE FORWARD LOWER DOOR SILL, AT THE GIRT FITTING, FRAME 20, STRINGER 23L. REPAIRED THE DOOR SILL IAW SRM 53-11-14-283-005, FIGURE 10108.SDR AALA201902019019Door Sill · corrodedCORROSION FOUND ON THE FORWARD LOWER DOOR SILL AT THE GIRT FITTING, FRAME 16, STRINGER 23L. REPAIRED THE DOOR SILL IAW SRM 53-11-14-283-005, FIGURE 10108.SDR AALA20190130003Web · corrodedAFT CARGO DOOR THRESHOLD WEB HAD CORROSION. REPLACED THE THRESHOLD WEB IAW RD 51-00-05-1, AND SRM 51-10-02-0G.SDR AALA201901309017Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED PLATE IN AFT CARGO COMPARTMENT AT FR 48 BETWEEN S32R AND S35R. REPLACED PLATE PER SRM 51-72-11.SDR DALA2019013000623Doubler · corrodedSEVERAL CORRODED AREAS ON PREVIOUS DOUBLER REPAIR SPLICE ON STA Y=954 AND Y=994 AT AFT CARGO COMPARTMENT. (C2). NRC 00254: CORROSION LEVEL 2, DOUBLERS REPAIR SPLICE ON STA Y=954 AND Y=994 AT AFT CARGO COMPARTMENT WERE REPLACED PER SRM 53-20-15-2R-7. (LP #09240SDR KCSA201901291012Structure · crackedCRACK INDICATION NOTED ON LT FWD INNER CHORD TOP HOLE AS MARKED.SDR SWAA2022030223610Scuff Plate · crackedAFT CARGO BAY FWD SCUFF PLATE IS CRACKED / REPAIRED AFT CARGO BAY FWD SCUFF PLATE IAW SWA EA 1-A53-2076 REV 11SDR SWAA2022030223611Scuff Plate · crackedAFT CARGO BAY AFT SCUFF PLATE IS CRACKED / REPAIRED AFT CARGO BAY AFT SCUFF PLATE IAW SWA EA 1-A53-2076 REV 11SDR SWAA2022030223966Shield · corrodedFWD CARGO RH AFT SHIELD CORRODED SEVERAL AREAS BS 500 TO BS 500A RBL 22. MARKED. / REMOVED AND REPLACED FWD CARGO R/H AFT SHIELD BS 500 TO BS 500A RBL 22 MATERIAL LOSS 100% IAW B737-700 SRM 53-30-15-1A-1; DWG 143A8126 REV:A P/N 143A8126-31 ATAG# SH1089SDR A6WA2019012946346Stiffener · cracked*SUPPLEMENTAL INFORMATION* (DIFFICULTY DATE YEAR ENTERED IN ERROR, CHANGED FROM 2018 TO 2019) PAX DOOR ASSIST MOTOR OB MOUNT IS CRACKED AT LOWER RADIUS REMOVE AND REPLACED STIFFENER UAW SRM 51-52-06 AND 51-42-13.SDR SWAA2019022229974Support · corrodedAFT CARGO FLOOR STRUCTURE SUPPORT RAIL CORRODED AROUND FASTENER HOLES AT BS 945, RBL 8. R&R SUPPORT RAIL PER SRM AND DWG.SDR SWAA2019022129913Angle · corrodedAFT CARGO FLOOR STRUCTURE SUPPORT RAIL CORRODED AROUND FASTENER HOLE 2.5" FORWARD OF BS 294.5, RBL 3. R&R ANGLE PER SRM & DWG.SDR SWAA2019022129880Intercostal · crackedINTERCOSTAL CRACKED BETWEEN BS 344 TO BS 360, LBL 1. R&R INTERCOSTAL PER SRM & DWG.SDR SWAA2019022029847Intercostal · crackedINTERCOSTAL CRACKED BETWEEN BS 344 TO BS 360, LBL 12. R&R INTERCOSTAL IAW SRM & DWG.SDR SWAA2019022029846Intercostal · crackedINTERCOSTAL CRACKED BETWEEN BS 328 TO BS 344, LBL 47. R&R INTERCOSTAL PER SRM & DWG.SDR SWAA2019022029845Intercostal · crackedINTERCOSTAL CRACKED BETWEEN BS 312 TO BS 328, LBL 47. R&R INTERCOSTAL PER SRM & DWG.SDR SWAA2019022029844Intercostal · crackedINTERCOSTAL CRACKED BETWEEN BS 277 TO BS 294.5, RBL 1. R&R INTERCOSTAL PER SRM.SDR SWAA2019021929787Angle · crackedLT REAR SPAR VERTICAL PRESSURE DECK AT LOWER ANGLE CRACKED AT LBL 35. REPAIRED ANGLE IAW EA.SDR SWAA2019021829707Strap · corrodedAFT CARGO FLOOR STRUCTURE STRAP CORRODED 7" AFT OF BS 767 TO 6" FORWARD OF BS 867, RBL 19. R&R STRAP PER SRM.SDR SWAA2019021429610Intercostal · crackedINTERCOSTAL CRACKED BETWEEN BS 312 TO BS 328, RBL 35. R&R INTERCOSTAL PER SRM.SDR SWAA2019021329569Web · corrodedAFT CARGO DOOR STRUCTURE WEB UNDER THRESHOLD CORRODED ON UPPER SURFACE BETWEEN BS 847 TO BS 867. R&R WEB PER SRM.SDR SWAA2019021329515Baffle · corrodedAFT CARGO COMPARTMENT INTERCOSTAL BAFFLE CORRODED BETWEEN BS 747 TO BS 767, RBL 21. R&R BAFFLE IAW SRM AND DWG.SDR SWAA2019021129439Strap · brokenAFT CARGO BAY SUB THRESHOLD TIE STRAP BROKEN BETWEEN BS 774 TO BS 862, RBL 21. R&R STRAP PER SRM & DWG.SDR SWAA2019021129444Gusset · crackedFORWARD CARGO GUSSET CRACKED AT BS 500D, STR 19L. R&R GUSSET IAW SRM AND DWG.SDR AALA201902079015Intercostal · corrodedAIRCRAFT WAS GROUNDED: CORROSION ON INTERCOSTAL BETWEEN BS 905 AND BS 927 AND BETWEEN S22L AND S23L. REPLACED INTERCOSTAL PER SRM 51-40-02.SDR AALA201902059010Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON RIGHT HAND AFT DOOR CUTOUT LOWER RIGHT HAND CORNER SHAPE FITTING AT FR 68 AND S23R. REPLACED CORNER SHAPE FITTING PER SRM 51-72-11.SDR AALA201902059003Door Sill · corrodedAIRCRAFT IN BASE MAINTENANCE. CORROSION ON R4 DOOR SILL AT FR 68 AND -Y1292. REPAIRED R4 DOOR SILL PER SRM 53-41-14-300-001.SDR AALA201902049037Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON RIGHT HAND AFT DOOR CUTOUT, RIGHT AFT CORNER SHAPE FITTING AT FR 68 AND S23R. REPLACED AFT CORNER SHAPE FITTING PER SRM 51-72-11.SDR AALA201902049036Door Sill · corrodedAIRCRAFT IN BASE MAINTENANCE. CORROSION ON L4 DOOR SILL AT FR 68 AND +Y1292. REPAIRED L4 DOOR SILL PER SRM 53-41-14-300-001 REPAIR PRINCIPLE 5.SDR AALA201902049035Shear Plate · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON RIGHT HAND SHEAR PLATE BETWEEN FR 69 AND FR 70 AT S23R. REPLACED SHEAR PLATE PER SRM 51-72-11.SDR JJBA201902068048Floor Support · corrodedCORROSION - LH OMEGA BEAM LOWER FLANGE FR 23-29. REMOVED CORROSION FROM LH OMEGA BEAM LOWER FLANGE FR 23-29 VIA BLEND OUT. AFTER BLEND OUT 0.017 MATERIAL WAS REMOVED AT DEEPEST POINT AND ONLY 0.015 IS ALLOWED. FABRICATED, LOCATED, INSTALLED, DOUBLER. RESTORED SDR JJBA201902068046Floor Support · corrodedCORROSION FOUND ON LEFT OMEGA BEAM JUST AFT OF FR 59 UPON POST REMOVAL INSPECTION OF LH FLOOR BEAM GUSSET BETWEEN FRAMES 59-61. PERFORMED CUT OUT, FABRICATED AND INSTALLED REPAIR DOUBLER FOR LH OMEGA BEAM BETWEEN FRAMES 59-61.SDR JJBA201902068045Floor Support · corrodedCORROSION ON CENTER OMEGA BEAM AT FR 20 UNDERNEATH SILL. REMOVED AND REPLACED CENTER OMEGA BEAM AT FR 20. RESTORED SURFACE PROTECTION.SDR SWAA2019020529220Support Angle · corrodedAFT CARGO BAY FORWARD DOOR SHIELD SUPPORT ANGLE CORRODED BETWEEN BS 767 TO BS 787, RBL 21. R&R ANGLE IAW SRM AND DWG.SDR AALA2019020549034Shear Plate · corrodedAIRCRAFT IN BASE MAINTENANCE. CORROSION ON LEFT HAND SHEAR PLATE BETWEEN FR 69 AND FR 70. REPLACED SHEAR PLATE PER SRM 51-42-11.SDR AALA2019020529004Floor Support · corrodedCORROSION FOUND ON THE CABIN FLOOR SUPPORT BETWEEN FRAMES 17 AND 18, RBL 43. REPLACED THE FLOOR SUPPORT IAW RD 53-00-00-3, REPAIR 3.SDR A6WA2019012946345Intercostal · crackedAEB STRINGER 15L INTERCOSTAL CRACKED REMOVED AND REPLACED AEB STRINGER 15L INTERCOSTAL IAW SRM 51-42-06 AND 51-42-21.SDR DALA2019012900611Spacer · corrodedAWR. INITIAL INSPECTION. CORROSION ON SPACER IN LWR BEAM PREVIOUS REPAIR AT AFT CARGO DOOR CUT OUT LWR AREA. CORROSION LEVEL 2. SPACER ON BEAM PREVIOUS REPAIR AT AFT CARGO DOOR WAS REPLACED PER SRM 53-05 FIG 123. (LP0922716)SDR DALA2019012900610Cusp Web · corrodedCORROSION OUT OF LIMITS ON CUSP-MEMBRANE RT SIDE BETWEEN STA 560-636 IN REF NRC 00240. NRC 00481: CORROSION LEVEL 2, WEB WAS REPLACED PER SRM 53-00-55-2R-4 FIG 226 AND 51-41-02-0G. (LP #0923003)SDR DALA2019012800597Support · corrodedDURING INSPECTION FOUND CORROSION CHANNEL SUPPORT BTW STA 767 TO STA 787+4 AT LEVEL STR 25R AT AFT CARGO COMPARTMENT. REPLACED CHANNEL SUPPORT PER SRM 51-40-02 AND DWG 146A0081.SDR IPXA2019030439661Structure · corrodedINSPECTION TYPE:D2 CORROSION ON UPPER CAP (P/N:65B38093-40) AT MAIN DECK CARGO COMPARTMENT AT STA 1860, LBL 16.69. REPAIR IAW SRM 53-00-51-1A-1 ALLOWABLE DAMAGE DETAIL II REV.85.00.SDR IPXA2019030439658Structure · corrodedINSPECTION TYPE:D2 CORROSION ON UPPER CHORD (P/N:146U5114-13) AT MAIN DECK CARGO COMPARTMENT AT STA 1960, RBL 3. REPAIR IAW SRM 53-00-51-1A-1 ALLOWABLE DAMAGE DETAIL REV .85.00.SDR SWAA2019021529648Intercostal · corrodedAFT CARGO BAY AREA INTERCOSTAL CORRODED BETWEEN BS 787 TO BS 807, RBL 6. R&R INTERCOSTAL IAW SRM AND DWG.SDR SWAA2019021429614Shield · corrodedAFT CARGO BAY RT FORWARD FLOOR SHIELD CORRODED BETWEEN BS 767 TO BS 787+5. R&R SHIELD IAW SRM & DWG.SDR SWAA2019021329585Angle · corrodedAFT CARGO BAY LT Z ANGLE CORRODED BETWEEN BS 727C TO BS 747+10. R&R Z ANGLE IAW SRM.SDR SWAA2019021329568Bracket · crackedFORWARD CARGO CORNER GUSSET BRACKET CRACKED AT BS 500D, STR 18L. R&R BRACKET PER SRM.SDR IPXA201902138893Stiffener · crackedINSPECTION TYPE:C11CRACK ON VERTICAL STIFFENER AT WHEEL WELL BULKHEAD AT STA 287,RBL 25, WL 159.REPAIR I.A.W UPS EO B767-5310-20118-F AND 767-300F SRM 51-70-12 GENERAL, FIGURE 1 , REV 73.01SDR SWAA2019021329533Angle · corrodedAFT CARGO BAY RT Z ANGLE CORRODED BETWEEN BS 727C TO BS 767. R&R Z ANGLE IAW SRM AND DWG.
Back to JASC 5320