SDR DALA2019012000389Cusp Web · corrodedCORROSION ON LT CUSP WEB STA 874-883 AT PAX CABIN IN REF NRC 00238 IS OUT OF LIMITS. NRC 00476: CORROSION LEVEL 2, CUSP WEB STA 874-883 AT PAX CABIN WAS REPAIRED PER SRM 53-00-55-2R-4. (LP #0910970)SDR DALA2019012000388Cusp Web · corrodedCORROSION OUT OF LIMITS ON CUSP-MEMBRANE RT SIDE BETWEEN STA 385-389 IN REF NRC 00240. NRC 00479: CORROSION LEVEL 2, CUSP-MEMBRANE RT SIDE BETWEEN STA 385-389 WAS REPAIRED PER SRM 53-00-55-2R-4 FIG 224. (LP #0910963)SDR DALA2019012000387Cusp Web · corrodedCORROSION ON LT CUSP WEB STA 864-870 AT PAX CABIN IN REF NRC 00238 IS OUT OF LIMITS. NRC 00475: CORROSION LEVEL 2, CUSP WEB STA 864-870 WAS REPAIRED PER SRM 53-00-55-2R. (LP #0910951)SDR FDEA201901200185Mount Fitting · corrodedAFT. CARGO COMPT. UPON REMOVAL OF TRANSITION PANEL SECTION FOR REPAIR. FOUND AT BS. 1440, AND STR.27R. CARGO TIEDOWN, MOUNT STRUCTURE FOR TIEDOWN WITH EXFOLIATED CORROSION. FOUND AFT CARGO TIEDOWN MOUNT STRUCTURE CORR. TO BE 100% MAT LOSS OUT OF LIMITS IAW SRMSDR A6WA2019012146314Support Angle · crackedLT WINDSHIELD SUPPORT ANGLE IS CRACKED BETWEEN FS 220.00 AND FS 235.00 BETWEEN STGR 11L TO 14L.SDR SWIA2019022645571Gusset · corrodedGUSSET ON FS310.00 FRAME STGR13L IS CORRODED. (C-CHECK) RO: 02/23/2019 REMOVED AND INSTALLED NEW GUSSET P/N 600-31109-57 IAW SRM.SDR WVER2019020217Channel · corrodedFWD WATER DRAIN MAST U CHANNEL IS CORRODED BEYOND LIMITS.SDR SIMA20190119007Cleat · corrodedFRAME FS319.70 HAS A CORRODED SHEAR CLEAT AT 21L. EVALUATED FRAME FS319.70 AT STRINGER 21L, FOUND ONLY LIGHT SURFACE CORROSION. REPAIRED IAW SRM 51-21-06.SDR V0XD2019013009Angle · crackedQUARTER TURN ANGLE, ATTACHED TO FS 280 BEAM, CRACKED. REMOVED AND REPLACED CRACKED 1/4 TURN ANGLE ATTACHED TO FS 280 BEAM IAW SRM 51-42-06.SDR DALA2019011900469Door Sill · corroded(LOG 0909738) DURING INSPECTION FOUND CORROSION LOWER SILL BTW STA 787+4 TO STA847 AND AT LEVEL OF STRG 25R AT AFT CARGO COMPARTMENT. REPLACED LOWER SILL BTW STA 787+4" TO STA.847 AND AT LEVEL OF STRG.25R AT AFT CARGO COMPARTMENT ASPER SRM 51-40-02 AND DRAWINGSDR DALA2019011900468Intercostal · corroded(LOG 0909609) DURING INSPECTION FOUND CORROSION WEB - INTERCOSTAL AT AFT CARGO COMPARTMENT BS 767 TO BS 787 STRINGER 25R. REPLACED WEB -INTERCOSTAL AT AFT CARGO COMPARTMENT BS 767 TO BS 787 STRINGER 25R AS PER SRM 51-10-02 AND DRAWING #146A0081.SDR AALA2019012319001Floor Support · corrodedCORROSION FOUND ON THE FLOOR SUPPORT BETWEEN BS 947.5 AND 967, LBL 24 AND LBL 27. REPAIRED THE FLOOR SUPPORT IAW EA 288928.SDR DALA2019012000457Support · crackedSHIP 6709 CRACKED CEILING SUPPORT AT FWD CARGO COMPARTMENT, STA 560, Z-5, S-18L, LBL 50, IN REFERENCE TO NRC 493. CORRECTIVE ACTION: NR 0620 PERMANT REPAIR WAS PERFORMED ON CEILING SUPPORT AT FWD CARGO COMPARTMENT, STA 560, Z-5, S-18L, LBL 50 PER ER/A 574704-1SDR REXA2019011900054Fitting · corrodedFLOOR FITTING LBL 27 FS 605-621 IS CORRODED ON PANEL LANDING. REPAIRED FLOOR FITTING AT LBL27 IAW EA 253-08237 REV IR.SDR DALA2019011900442Door Sill · corrodedCORROSION. CONFIRM DT EVALUATION FOR POSSIBLE FCS REPAIR LOWER SILL AT FR66 LEVEL OF STRG 23L AT AFT GALLEY AREA. REPLACED LOWER SILL AT FR66 TO FR68 AT LEVEL STR. 23L AFT GALLEY AREA AS PER SRM 51-72-11, SRM 51-42-11 AND DWG NO. D53480505.SDR DALA2019011900413Stiffener · crackedMFEC INSPECTION FOUND 01 EA CRACK APPROX 0.350" IN LENGTH ON LT NOSE WHEEL WEEL VERTICAL STIFFENER. CRACK REPAIRED. (LP 0909635)SDR DALA2019011900412Stiffener · crackedMFEC INSPECTION FOUND 01 EA CRACK APPROX 0.350" IN LENGTH ON RT NOSE WHEEL WEEL VERTICAL STIFFENER AND THE CRACK IS FOUND FROM WL159.00 TO WL 185.00. REPAIRED. (LP 0909624)SDR CALA2019012100131Door Sill · corrodedA3NB-53-3-6105 (A33-015) FWD CARGO BAY ENTRY SILL IS CORRODED. NONROUTINE 9021032 COMPLIED WITH ECRA 5341-01150. REPAIR CONSIDERED PERMENANT. NO F URTHER ACTION REQUIRED FWD CARGO BAY ENTRY SILL.SDR CALA2019012100129Fastener · shearedMAIN CABIN FLOOR FR68 R2 DOOR SILL AFT GIRT BAR SUPPORT HAS SHEARED FASTNER A3NB-53-3-6222 ON LCQ NR 9298248 REMOVED AND REPLACED R2 DOOR SILL BETWEEN FR66-FR68 IAW SRM 51-72-11-911-001.SDR CALA2019012100128Support Angle · corrodedMAIN CABIN FR68 L2 DOOR SILL SUPPORT ANGLE HAS CORROSION SPOTS ON UPPER SURFACE A3NB-53-3-6222 ON LCQ NR 9298263 INSTALLED REPAIR ANGLE AND FILLER IAW SRM 53-41-14. ALODINE AND PRIMED IAW SRM 51-21-11-001. INSTALLED GIRT BAY ASSY IAW IPC 53-46-04-81 AND AMM 52SDR DALA2019012000386Cusp Web · corrodedCORROSION OUT OF LIMITS ON CUSP-MEMBRANE RT SIDE BETWEEN STA 496-500 IN REF NRC 00240. NRC 00480: CORROSION LEVEL 2, CUSP-MEMBRANE RT SIDE BETWEEN STA 496-500 WAS REPAIRED PER SRM 53-00-55-2R-4 AND 51-41-02-0G. (LP #0910461)SDR FDEA201901190180Adapter · damagedMCD ADAPTER FR 57.3 LT DAMAGED. REMOVED AND REPLACED MDCC ADAPTER FR 57.3 LT IAW SRM 51-40-21, CAT A AND MAJOR REPAIR.SDR A6WA2019012146313Door Sill · corrodedRIGHT FLOOR SILL CORRODED FROM FS 559.00+48 TO 559.00+80. REPAIRED RIGHT FLOOR SILL IAW REO601R-53-00-526 REV-- AND EA 253-01141.SDR A6WA2019012146317Angle · corrodedPAX DOOR LOWER SILL ANGLE CORRODED. REPLACED PAX DOOR LOWER SILL ANGLE IAW SRM 51-42-02.SDR SWAA2022030145007Angle · crackedAFT CARGO; STA 867; LBL9; JUST BELOW CARGO FLOOR; ATTACH ANGLE CRACKED; COMMON TO VERTICAL BULKHEAD SUPPORT. / REMOVED AND REPLACED CRACKED ATTACH ANGLE; AFT CARGO; STA 867 LBL 8 WITH NEW PART P/N 149A8109U114 IAW SRM 51-40-02 AND DWG 149A8102 REV - ATAG ZP007SDR SWAA2022022445005Splice Plate · corrodedAFT CARGO FLOOR PANEL SPLICE PLATE CORRODED STA 767+5; RBL 18 TO LBL 18 / REMOVED AND INSTALLED AFT CARGO FLOOR PANEL SLICE PLATE AT STA 767 +5 RBL 18 TO LBL 18 P/N 146A9401-4 TAG # WN8493 IAW B737 DWG 146A7500 REV. - SRM 51-40-02-0G-0 AND APPLIED CIC IN PANELSDR FDEA201901180164Floor Support · crackedBULK CARGO COMPARTMENT STATION 1937, RIGHT BUTTOCK LINE 41 FLOOR PANEL STRINGER FOUND WITH CRACK. BULK CARGO COMPARTMENT STATION 1937 RIGHT BUTTOCK LINE 41 FLOOR PANEL STRINGER CRACKED REPAIRED AS PER SRM 53-70-53-2R FIGURE 202 REPAIR 2 AT STATION 1926 - STATISDR AALA201901231004Transition Panel · corrodedCORROSION FOUND ON THE FORWARD CARGO BAY LEFT TRANSITION PANEL BETWEEN BS 400 AND 420. REPLACED THE TRANSITION PANEL IAW SRM 53-00-53, AND 51-10-2.SDR AALA201901231003Transition Panel · corrodedCORROSION ON FORWARD CARGO COMPARTMENT RIGHT HAND TRANSITION PANEL BETWEEN BS 500A AND BS 500B. REPLACED THE TRANSITION PANEL IAW SRM 53-00-53-2R.SDR AALA201901231002Baffle · crackedTHE FORWARD CARGO BAY LEFT BAFFLE WAS CRACKED BETWEEN BS 400 AND 420. REPLACED THE BAFFLE IAW RD 51-00-05.SDR AALA201901238003Support Angle · corrodedCORROSION FOUND ON THE AFT CARGO BAY AFT BULKHEAD LOWER SUPPORT ANGLE AT BS 947, LBL 8.1. REPLACED THE SUPPORT ANGLE IAW RD 51-00-05, AND SRM 51-10-02.SDR DALA2019012200451Nut · damaged(AIRCRAFT 7001, L/P 0908454) AD EM-EO TASK - BULK CARGO FLOOR STRUCTURE AT STRUCTURE AT STA 1916 LBL FOUND 01EA ANCHORNUT DAMAGE. BULK CARGO FLOOR STRUCTURE AT STA 1916 LBL 01EA ANCHORNUT REMOVED AND REPLACED AS PER SRM 51-40-02.SDR DALA2019012200450Nut · damaged(AIRCRAFT 7001, L/P 0908446) AD EM-EO TASK - BULK CARGO FLOOR STRUCTURE AT STA 2050 LBL FOUND 01EA ANCHORNUT DAMAGE. BULK CARGO FLOOR STRUCTURE AT STA 2050 LBL 01EA ANCHORNUT. REMOVED AND REPLACED AS PER SRM 51-40-02.SDR DALA2019012000409Angle · cracked(LOG 0909466) DURING INSPECTION FOUND CRACK ANGLE - CLIP LOCATED STATION 500F AND STR 26R AT FWD CARGO COMPARTMENT. REPLACED ANGLE-CLIP LOC. STATION 500F AND STR 26R AT FWD CARGO COMPARTMENT AS PER SRM 51-10-02, 51-40-02 AND DRAWING #143A7505 REV.B.SDR DALA2019011900405Support Bracket · cracked(LOG 0909481) DURING INSPECTION FOUND CRACK SUPPORT BRACKET CHANNEL AT S-15L AT LEVEL BS.360 AT FWD GALLEY AREA. REPLACED SUPPORT BRACKET CHANNEL ST STR 15L AT LEVEL BS360 FWD GALLEY AREA AS PER SRM 51-10-02 ITEM 9 AND DRAWING #141A8194 REVISION B AND 141A8190SDR DALA2019011900404Angle · cracked(LOG 0909475) DURING INSPECTION FOUND CRACK ANGLE - CLIP LOCATED STA 500G AND STR 26R AT FWD CARGO COMPARTMENT. REPLACED ANGLE-CLIP LOCATED STA 500G AND STR 26R AT FWD CARGO COMPARTMENT AS PER SRM 51-10-02, 51-40-02 AND DWG 143A7505 REV.B.SDR DALA2019011900403Gusset · cracked(LOG 0909469) DURING INSPECTION FOUND CRACK GUSSET LOCATED STA 500H AND STR 19R AT FWD CARGO COMPARTMENT. REMOVED AND REPLACED GUSSET LOCATED STA 500H AND STR 19R AT FWD CARGO COMPARTMENT AS PER SRM 51-40-02 AND DRAWING 143A7902 REV.E.SDR SWAA2019012228799Attach Angle · crackedAFT CARGO ATTACH ANGLE CRACKED AT BS 867, LBL 9. R&R ANGLE IAW SRM & DWG.SDR SWAA2019012228783Attach Angle · crackedAFT CARGO ATTACH ANGLE CRACKED AT BS 727+6, BETWEEN LBL 20 TO RBL 20. R&R ANGLE IAW SRM & DWG.SDR FDEA201901180170Fitting · crackedMAIN DECK FLOOR STRUCTURE Z220 PICKUP FITTING AFT UPPER STIFFENING FLANGE CRACKED AT FR18 Y-1959 Z-177 REMOVED FABRICATED NEW AND INSTALLED PICKUP FITTING IAW DWG A53612406 REV C AND TORQUED BOLTS IAW SRM 51-49-00.SDR SWAA2022030121785Scuff Plate · corrodedFWD CARGO DOOR AFT SIDE SCUFF PLATE PITTED IN NUMEROUS AREAS ON TOP SIDE / REMOVED SCUFF PLATE. LOCATED AND DRILLED NEW SCUFF PLATE AND INSTALLED PER SRM 51-40-02.FILLET SEAL TO BE ACCOMPLISHED ON ROUTINE CARD #753-646-63-01SDR SWAA2022030121786Scuff Plate · corrodedFWD CARGO DOOR FWD SIDE SCUFF PLATE PITTED IN NUMEROUS AREAS ON TOP SIDE / REMOVED SCUFF PLATE. LOCATED AND DRILLED NEW SCUFF PLATE AND INSTALLED PER SRM 51-40-02.FILLET SEAL TO BE ACCOMPLISHED ON ROUTINE CARD #753-646-63-01SDR SWAA2022030121787Scuff Plate · corrodedAFT CARGO DOOR FWD SIDE SCUFF PLATE PITTED IN NUMEROUS AREAS / REPLACED DAMAGED SCUFF PLATE WITH NEW SCUFF PLATE; PART #654A0004-97; REF. AMM 53-11-02. LOCATED; DRILLED; AND DEBURRED PER SRM 51-40-05. SCUFF PLATE WILL BE INSTALLED ON ROUTINE TASK CARDS: 753-72SDR SWAA2022030174331Strip · corrodedIN AFT CARGO PIT; 4 EA. CAP STRIPS CORRODED ON L/H SIDE OF FLOOR PNL'S / RECEIVIED 4EA NEW CAP STRIPS FOR AFT CARGO L/H SIDE; P/N -453A2611-8 ON ATAG# WN2510 P/N -453A2611-10 ON ATAG# A90113; P/N -453A2611-4 ON ATAG# WN2988; AND P/N- 453A2611-13 ON ATAG# A9019SDR SWIA2019022145557Panel · corrodedRT PRESSURE FLOOR SILL PANEL HAS MULTIPLE AREAS OF CORROSION. (C-CHECK) RO: 02/20/2019 COMPLIED WITH REPAIR TO THE RT PRESSURE FLOOR SILL PANEL MULTIPLE AREAS OF CORROSION IAW REO.SDR SWIA2019022145556Angle · corrodedLT PRESSURE FLOOR SILL ANGLE HAS MULTIPLE AREAS OF CORROSION. (C-CHECK) RO: 02/20/2019 BLENDED CORROSION FROM LT PRESSURE FLOOR SILL ANGLE IAW SRM.SDR SWIA2019022145555Panel · corrodedLT PRESSURE FLOOR SILL PANEL HAS MULTIPLE AREAS OF CORROSION. (C-CHECK) RO: 02/20/2019 BLENDED CORROSION ON LT PRESSURE FLOOR SILL PANEL IAW SRM AND REO.SDR SWIA2019022145540Floor Support · corrodedREPLACE RH FLOOR BEAM AT FS.589.00 TO FS.621.00 RBL27 WITH SERVICEABLE DUE TO OUT OF LIMITS CORROSION. (C-CHECK) RO: 02/20/2019 REMOVED AND REPLACED RH FLOOR BEAM AT FS.569.00 TO FS.621.00 RBL27 IAW REO.SDR SWIA2019022145539Floor Support · corrodedREPLACE THE RH FLOOR SILL FROM FS 559.0+16 TO 559.0+80 WITH SERVICEABLE DUE TO OUT OF LIMITS CORROSION. REMOVED AND INSTALLED NEW RH FLOOR SILL FROM FS 559+16 TO FS 559+84.9 IAW SRM.SDR SWIA2019022145538Floor Support · damagedREPLACE R/H FLOOR BEAM UPPER CAP AT RBL 9 FROM FS 559+12 TO FS 559+120 DUE TO DAMAGE. (C-CHECK) RO: 02/20/2019 REPLACED FLOOR BEAM CAP WITH NEW BEAM CAP LOCATED AT RBL9 BETWEEN FS559+12 TO FS559+120 IAW REO AND SRM.
Back to JASC 5320