JASC 5320
Service difficulty reports · 216,415
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2019011437862Seal Depressor · gougedINSPECTION TYPE:12YR FWD CARGO DOOR OPENING FWD UPPER SEAL DEPRESSOR GOUGED. REMOVED AND REPLACED IAW SRM 51-40-21.SDR ASOA201901097005Floor Support · corrodedCORROSION ON GALLEY CENTER OMEGA BEAM TOP CAP. REMOVED CENTER OMEGA BEAM TOP CAP. REPAIRED CENTER OMEGA BEAM BY CUTTING OUT THE CORRODED AREA, INSTALLED EXTERNAL DOUBLER AND NEW TOP CAP.SDR AALA201901099028Shear Panel · corrodedCORROSION FOUND ON THE AFT CABIN SHEAR PANEL BETWEEN FRAMES 87 AND 88, RBL 508. REPLACED THE SHEAR PANEL IAW RD 53-00-00-3, REPAIR 3.SDR DALA2019010700118Door Sill · corrodedSHIP 5636 LOWER FLOOR BOARD OUTBD FRAME AT LT DOOR SILL IS CORRODED. CORRECTIVE ACTION: REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS, FABRICATED REPAIR AND INSTALLED REF SRM AND DWG REV K. (0893090)SDR JJBA20190105016Support · crackedCRACK IN RT OMEGA BEAM I/B SUPPORT AFT SECTION BETWEEN FR 47-48. REMOVED AND REPLACED RT OMEGA BEAM I/B SUPPORT AFT SECTION BETWEEN FR 47-48.SDR JJBA20190105015Fitting · crackedCRACK IN SHEAR CLIP FR 80 BETWEEN STR 6-7L. INSTALLED NEW SHEAR CLIP FR 8 BETWEEN STR 6-7L.SDR JJBA20190105014Fitting · crackedCRACK IN SHEAR CLIP FR 73 BETWEEN STR 8-9R. REMOVED AND REPLACED SHEAR CLIP FOR FR 73 STR 8-9R.SDR JJBA20190105013Fitting · crackedCRACK IN SHEAR CLIP FR 65 BETWEEN STR 7-9L. REMOVED AND REPLACED SHEAR CLIP FR65 BETWEEN STR 7-9L AND RESTORED FINISH.SDR JJBA20190105012Fitting · crackedCRACK IN SHEAR CLIP FR 65 BETWEEN STR 18-19L. REMOVED AND REPLACED SHEAR CLIP AT FR 65 BETWEEN STR 18L - STR 19L.SDR JJBA20190105008Support · crackedCRACK IN RT OMEGA BEAM O/B SUPPORT AFT SECTION BETWEEN FR 47-48. REMOVED AND REPLACED RT OMEGA BEAM O/B SUPPORT AFT SECTION BETWEEN FR 47-50.SDR JJBA20190105006Fitting · crackedCRACK IN SHEAR CLIP FR 72 BETWEEN STR 17L - 18L. REMOVED AND REPLACED THE SHEAR CLIP BETWEEN STRINGER 17L - 18L ON FRAME 72.SDR DALA2019010600094Gusset · crackedCRACK INDICATION ON GUSSET PLATE, RIGHT SIDE STA 68 STR 12R 4TH HOLE FROM TOP INCREASED HOLE SIZE TO .191 AND REPLACED FASTENER IAW SRM 51-42-44M 53-44-23 AND 51-43-00.SDR DALA2019010600090Gusset · crackedCRACK INDICATION ON GUSSET PLATE RIGHT SIDE STA 68 STR 16R. INCREASED HOLE SIZE TO .191 AND REPLACED FASTENERS IAW SR< 51-42-11, 43-44-23 AND 51-43-00.SDR DALA2019010600089Gusset · crackedCRACK INDICATION ON GUSSET PLATE RIGHT SIDE STA 68 STR 14R 4TH HOLE FROM TOP. INCREASED HOLE SIZE TO .191 AND REPLACED FASTENER IAW SR 51-42-11, 53-44-23 AND 51-43-00.SDR AALA201901075003Floor Support · crackedCRACKED FORWARD GALLEY FLOOR SUPPORT BETWEEN BS 328 AND 344, LBL 45.6. REPLACED THE FLOOR SUPPORT IAW RD 51-00-05-01.SDR CALA2019010600041Fitting · damagedKEEL BEAM, RT AFT REINFORCEMENT FITTING IS DAMAGED. LOCATED AND DRILLED NEW R/H AFT REINFORCEMENT FITTING IAW SRM 51-72-11-911-001. FITTING INSTALLED ON ROUTINE CARD 4250290, 18-0553-8-0008 SEQ NR 1944.SDR SWAA2022030164061Angle · corrodedCORROSION ON UPPER SURFACE OF TRANSITION ANGLE IN FORWARD CARG BIN STATION 502-500B +2 LBL 25. / REMOVED AND REPLACED TRANSITION ANGLE SECTION FROM B/S 490 TO 520 LBL 25. PER SRM 53-00-53-2R-5. CORRODED ELEMENT SRM 53-30-53-01-2; FIGURE 2; ITEM1; P/N 143A7501.SDR SIMA20190104016Retainer · damaged312AR DOOR FRAME SURROUND HAS RECEPTACLE PULLED THROUGH. C/A-REPAIRED DAMAGE IAW ERS-EM-T3MR-3590.SDR AALA201902119040Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: WINDSHIELD CENTER POST LEFT HAND CONTINUITY FITTING CRACKED. REPLACED CONTINUITY FITTING PER EA 288632.SDR AALA201902089012Intercostal · crackedCRACKED INTERCOSTAL FITTING AT FRAME 16M, STRINGER 15R AND 16R AT THE NR 7 DOOR STOP FITTING AREA. REPLACED THE INTERCOSTAL FITTING IAW SRM 51-72-11.SDR SIMA20190104006Floor Support · corrodedCABIN CENTER OMEGA BEAM AT FR38 IS CORRODED.SDR SIMA20190104012Floor Support · corrodedCABIN LT OMEGA BEAM AT FR.38 IS CORRODED. REPAIRED CABIN LT OMEGA BEAM AT FR 38 IAW SRM 53-00-10RE ITEM 3 FIGURE 202 SHEET 2.SDR SWAA2019020529204Fitting · crackedFORWARD CARGO BAY INTERCOSTAL CLIP CRACKED AT BS 400, LBL 24. R&R CLIP IAW SRM AND DWG.SDR SWAA2019020529203Gusset · crackedFORWARD CARGO BAY GUSSET CRACKED AT BS 500D, STR 19L. R&R GUSSET PER SRM AND DWG.SDR SWAA2019013129087Gusset · crackedFORWARD CARGO BAY GUSSET CRACKED AT BS 500D, STR 19R. R&R GUSSET PER SRM & DWG.SDR SWAA2019013129062Door Sill · corrodedL2 DOOR MOP SILL CORRODED BETWEEN BS 960 T BS 992, LBL 52. R&R MOPSILL IAW SRM AND DWG.SDR V0XD2019013003Web · crackedLT FWD EQUIPMENT FLOOR WEB AT FS 193 IS CRACKED. REPAIRED LT FWD EQUIPMENT FLOOR WEB AT FS 193 IAW REO 670-53-11-509 REV E, DATED 2018-02-08 AND REO 670-53-1-1494, DATED 2019-01-26.SDR V0XD2019013002Striker · crackedRT FWD EQUIPMENT COMPARTMENT LATCH STRIKER CRACKED. REMOVED AND REPLACED RT FWD EQUIPMENT COMPARTMENT DOOR LATCH STRIKER IAW SRM 51-42-06 AND 51-42-13.SDR SWAA2019012828949Shield · corrodedFORWARD CARGO BAY FLOOR TO SIDEWALL SHIELD CORRODED BETWEEN BS 500 TO BS 500A, RBL 22. R&R SHIELD IAW SRM & DWG.SDR SWAA2019012828920Shield · corrodedAFT CARGO BAY AFT SHIELD BETWEEN BS 847 TO BS 867, RBL 20. R&R SHIELD IAW SRM AND DWG.SDR SWAA2019012828919Support · corrodedAFT CARGO FLOOR TO SIDE WALL SUPPORT CORRODED BETWEEN BS 727C TO BS 798, LBL 21. R&R SUPPORT PER SRM & DWG.SDR SWAA2019012828918Support · corrodedAT AFT CARGO FLOOR TO SIDE WALL SUPPORT CORRODED BETWEEN BS 727 TO BS 767, RBL 21. R&R SUPPORT IAW SRM AND DWG.SDR ASOA201901043007Gusset · corrodedDURING C CHECK INSPECTION GUSSET FOR RIGHT CENTER HAT BEAM ASSEMBLY IN LAV WAS CORRODED THROUGH AROUND LAV WATER LINES. MAINTENANCE REPLACED GUSSET.SDR ASOA201901043006Door Sill · corrodedDURING C CHECK INSPECTION FOUND FAR LEFT SILL IN LAV CORRODED THROUGH @ AFT NUTPLATE. MAINTNENACE REPLACED LEFT SILL. FRAME 59-60.SDR ASOA201901043005Buttstrap · corrodedDURING C CHECK INSPECTION FOUND BUTT STRAP FOR CENTER OMEGA BEAM IN LAV FRAME 59-60 CORRODED THROUGH @ AFT NUT PLATE. MAINTENANCE REPLACED BUTT STRAP FOR CENTER OMEGA BEAM AT FRAME 59-60.SDR SWAA2019012228806Support · corrodedFORWARD CARGO BAY FLOOR TO SIDEWALL SUPPORT CORRODED BETWEEN BS 500A TO BS 500D, RBL 22. R&R SUPPORT PER SRM AND DWG.SDR SWAA2019012228774Support Strap · damagedINTERCOSTAL SUPPORT STRAP HAD CHAFING DAMAGE AT BS 292, STR 5R. REPAIRED STRAP IAW SRM.SDR SWAA2019012228755Threshold · corrodedFORWARD CARGO BAY SUB THRESHOLD WEB CORRODED BETWEEN BS 440 TO BS 500, RBL 22. R&R WEB IAW SRM AND DWG.SDR SWAA2019012128720Door Sill · corrodedR2 DOOR MOPSILL CORRODED BETWEEN BS 960 TO BS 994, RBL 52. R&R MOPSILL IAW SRM & DWG.SDR ASAA2019010427832Floor Support · crackedCABIN FLOOR SUPPORT AT STA 540 FROM BL 0 TO RBL 25 IS CRACKED. GROUNDED - YES. REMOVED AND REPLACED FLOOR SUPPORT IAW SRM 51 40 02 0G 0.SDR RAIA201901040002Crossbeam · corrodedSURFACE CORROSION ON AFT CROSS PIECE AT AFT END OF FLOOR BOARD 231GF. REMOVED AND REPLACED CROSS BEAM AT AFT END OF FLOOR BOARD 231GF.SDR SWAA2019011628536Angle · corrodedANGLE CORRODED AT BS 663+4, RBL 69. R&R ANGLE PER DWG & SRM.SDR SWAA2019011628518Gusset · crackedFORWARD CARGO GUSSET PLATE CRACKED AT BS 500D, STR 19R. R&R GUSSET PLATE PER SRM & DWG.SDR SWAA2019011628517Gusset · crackedFORWARD CARGO GUSSET PLATE CRACKED AT BS 500D, STR 19L. R&R GUSSET PLATE PER SRM & DWG.SDR REXA2019010400025Angle · crackedANGLE CLIP IS CRACKED ON THE I/B SIDE OF LBL 36 AT FS 484, IN THE CABIN BELOW THE FLOOR. REMOVED/REPLACED ANGLE CLIP AT STATION 484 LBL36 IAW REO 601R-53-41-059.SDR AALA201901099024Fitting · crackedCRACK INDICATION ON THE L1 DOOR CUTOUT INTERCOSTAL FITTING AT FRAME 16 AT THE NR 1 DOOR STOP. REPLACED THE INTERCOSTAL FITTING IAW SRM 51-72-11.SDR AALA2019010759013Gusset · corrodedCORROSION ON THE GUSSET AT FRAME 90, RBL 58.4. REPLACED THE GUSSET IAW SRM 51-40-03.SDR JJBA20190104005Threshold · corrodedCORROSION IN CARGO DOOR THRESHOLD BEAM BETWEEN FR 65-68. REMOVED AND REPLACED AFT CARGO THRESHOLD BEAM FROM FR 65- FR 68. CORROSION FOUND TO BE LEVEL 2.SDR DALA2019010700092Gusset · crackedCRACK INDICATION ON GUSSET PLATE LEFT SIDE FR 68 STF 10L 1ST HOLE AND 3RD HOLE FROM TOP. INCREASED HOLE SIZE TO .191 AND REPLACED FASTENERS IAW SRM 51-43-00-001.SDR DALA2019010600088Gusset · crackedCRACK INDICATION ON GUSSET PLATE LEFT FR 68 STR12L, 4TH HOLE FROM TOP. INCREASED HOLE SIZE IAW SRM 51-42-144. REPLACED FASTENERS IAW SRM 51-43-00-01.
Back to JASC 5320