JASC 5320
Service difficulty reports · 216,095
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2025112626183Support Angle · crackedCRACK ON CARGO LINER SUPPORT ANGLE LOCATED BS 727B LBL49 AT AFT CARGO COMPARTMENT. PERFORMED PERMANENT REPAIR LOCATED ON CARGO LINER SUPPORT ANGLE LOCATED BS 727B LBL49 AT AFT CARGO COMPARTMENT IAW SRM 51-70-11-2R-0.SDR ASAA2025102062318Shield · corrodedAFT CARGO FWD SHIELD CORRODED STA 787 TO 767. GROUNDED - YES. REMOVED DAMAGE WITH SURFACE BLEND FOUND TO BE OUT OF LIMITS REMOVED AND REPLACED AFT CARGO FWD SHIELD I.A.W. B737-900 SRM 51-40-02-0G-0. W= 1 O= .050 R= .035 L= 1 D=.015.SDR ASAA2025102062317Transition Panel · corrodedAFT CARGO LT TRANSITION CORRODED STA 827 TO 727A. GROUNDED - YES. REMOVED DAMAGE FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 FROM STA 827 TO 727A FABRICATED, LOCATED AND INSTALLED DRILLED NEW TRANSITION PANEL IAW SRM 53-00-53-2R-5 FROM STA 827 TO 727A. W=SDR ASAA2025102062316Transition Panel · corrodedAFT CARGO LT TRANSITION CORRODED STA 827 TO 727A. GROUNDED - YES. REMOVED DAMAGE FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 FROM STA 827 TO 727A FABRICATED, LOCATED AND INSTALLED DRILLED NEW TRANSITION PANEL IAW SRM 53-00-53-2R-5 FROM STA 827 TO 727A. W=SDR ASAA2025102062220Transition Panel · corrodedAFT CARGO R/H TRANSITION CORRODED STA 767 TO 727A GROUNDED - YES. REMOVED DAMAGE FOUND TO BE OUT OF LIMITS IAW B737-900ER SRM 53-00-53-1A-2 FROM STA 827 TO 727A FABRICATED, LOCATED AND INSTALLED DRILLED NEW TRANSITION PANEL IAW B737-900ER SRM 53-00-53-2R-5 FROSDR ASAA2025102062222Transition Panel · corrodedAFT CARGO RT TRANSITION PANEL CORRODED BS 767 TO 727A. GROUNDED - YES. REMOVED CORROSION ON THE TRANSITION PANEL AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2, FABRICATED LOCATED, DRILLED AND INSTALLED A NEW TRANSITION PANEL IAW SRM 53-00-53-2R-5. W= 3SDR ASAA2025102062221Transition Panel · corrodedAFT CARGO RT TRANSITION PANEL CORRODED BS 767 - 727A. GROUNDED - YES. REMOVED CORROSION ON AFT CARGO RT TRANSITION PANEL AT STA 727A - 767. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 FABRICATED LOCATED, DRILLED & INSTALLED A NEW RT TRANSITION PANEL IAW SSDR JJBA20251107009Support · corrodedCENTER FUSELAGE, RT SILL FOUND CORRODED AT FRAME 19, BLENDED AND FOUND OUT OF LIMITS, CENTER FUSELAGE RH SILL CORROSION REMOVED, CUTOUT PERFORMED. CENTER FUSELAGE & RT SILL DOUBLE WAS MADE, DRILLED, PROTECTED AND INSTALLED. CENTER FUSELAGE RT SILL, ANGLE WAS SDR AALA202510318875Floor Support · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN PASSENGER CABIN FLOOR STRUCTURE INTERCOSTAL AT STA 324, RBL 31. REPLACED INTERCOSTAL PER AARD 51-00-05-1.SDR JJBA20251024061Gusset · corrodedFRAME 59-61 CORROSION ON GUSSET BLBL 19. REMOVED AND REPLACED GUSSET FROM FRAME 59-61 LBL 19SDR JJBA20251024060Floor Support · corrodedOMEGA BEAM CORRODED AT FRAME 59. REPAIRED OMEGA BEAM.SDR JJBA20251024054Gusset · corrodedFRAME 59-61 CORROSION ON GUSSET BL 0 FOUND OUT OF LIMITS. REMOVED AND REPLACED GUSSET BL 0 AT FRAME 59-61.SDR JJBA20251024053Floor Support · corrodedCORROSION ON FLOORSILL RBL 16 FRAME 39-40 FOUND OUT OF LIMITS. REMOVED AND REPLACED FLOORSILL.SDR JJBA20251024052Floor Support · crackedFRAME 65-69 FLOOR SILL CRACKED AT RBL 29 EVALUATED SILL AT FRAME 65-69 FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED FLOOR SILL FRAME 65-69.SDR JJBA20251024051Floor Support · corroded#1 FLOOR SILL HAS CORROSION FROM FRAME 28-30. REMOVED AND REPLACED #1 FLOOR SILL FROM FRAME 28-30.SDR CALA2025102410493Web · corrodedAFT CARGO COMPT. CARGO DOOR THRESHOLD WEB HAS MULTIPLE SPOTS OF CORROSION. REMOVED AND REPLACED AFT CARGO DOOR THRESHOLD WEB REF B-737 SRM 51-40-02-0G-0 AND DWG 146A8120.SDR DALA2025102307763Drain · corroded(LOG 1262745) CABIN FLOOR SUPPORT DRAIN TUBE INTERCOSTAL BETWEEN STA 947 AND 967 CORRODED AT RBL50. REMOVED AND REPLACED CABIN FLOOR SUPPORT DRAIN TUBE INTERCOASTAL BETWEEN STA 947 AND 967 RBL 50 AS PER REF B737-900 SRM 51-40-02-0G.SDR CALA2025102310432Support Angle · crackedLEFT VAPOR BARRIER SUPPORT SIDE ANGLE CRACKED AT BS 663, LBL 5. REMOVED AND REPLACED STIFFENER AT LT VAPOR BARRIER AT BS 663, LBL 5 IAW SRM 51-40-02-0G-0 AND DWG 144A7100.SDR CALA2025102110348Floor Support · corrodedCABIN FLOOR SUPPORT Y-1732 CORRODED FR 66 FWD LOWER CORNER R-2 DOOR. REMOVED AND REPLACED FLOOR SUPPORT Y-1732 R/H FR66 IAW SRM 51-42-11/001.SDR CALA2025102110347Floor Support · corrodedFLOOR SUPPORT Y-765 FR 64-70 HAS 2EA OUT OF LIMITS CORROSION SPOTS AT FR 66 AND 67. REMOVED AND REPLACED DISCREPANT Y-765 FR64-70 FLOOR SUPPORTIAW SRM 51-42-11-001.SDR CALA2025102010260Ceiling Panel · leakingWATER COMING FROM CEILING PANELS IN AFT CARGO PIT ADDING PIC. MOST AFT WALL IN AFT PIT CEILING PANEL ABOVE IT HAS WAYER DRIPPING FROM IT PARTIALLY REMOVED AFFECTED CEILING PANEL REF AMM 25-52-09, HARDWEAR IN PARTS BAG IN AFT PIT CLEANED ANY AND ALL RESIDUAL MOSDR CALA2025102010259Ceiling Panel · leakingMORE WATER DRIPPING FROM CEILING PANEL AT STA 849 IN AFT CARGO PIT PARTIALLY REMOVED PANEL REF AMM 25-52-09, HARDWEAR IN PARTS BAG IN AFT PIT CLEANED ANY AND ALL RESIDUAL MOISTURE AND SECURED AND TAPED PANEL AFTER ENSURING NO STANDING WATER, STAINS OR ANY SMELSDR CALA2025102010258Ceiling Panel · leakingFOUND MORE WATER DRIPPING FROM SECOND TO LAST CEILING PANEL IN AFT CARGO PIT PARTIALLY REMOVED PANEL REF AMM 25-52-09, CLEANED ANY AND ALL RESIDUAL MOISTURE AND SECURED AND TAPED PANEL AFTER ENSURING NO STANDING WATER, STAINS OR ANY SMELLS. THERE IS NO EVIDESDR SWAA2025112025843Angle · crackedCRACKED ANGLE, BS 420, RBL 24 IN THE FWD CARGO BAY. REPLACED THE ANGLE AND FASTENERS IAW SRM 51-40-02-OG-0, SRM 51-10-02-0G-0, ITEM 9, AND DWG 143A7505, SHEET 81, REV -.SDR SWAA2025112025842Angle · crackedCRACK ANGLE, LOCATED BS 440, LBL 24 AT FWD CARGO COMPARTMENT. REPLACED THE ANGLE AND FASTENERS LOCATED BS 440 LBL 24 AT FWD CARGO BAY IAW SRM 51-40-02-0G-0, SRM 51-10-02-0G-0, ITEM 9, & DWG 143A7505 SHEET 82, REV.SDR HNAA2025112000769Floor Support · corrodedFWD GALLEY RT CENTER FLOOR SUPPORT HAS CORROSION AROUND NUTPLATE HOLES. PERFORMED PERMANENT REPAIR ON FWD GALLEY RT CENTER FLOOR SUPPORT IAW EO1-53-25-0387 AND SRM 53-21-02, ITEM 2, FIG 201.SDR HNAA2025112000766Floor Support · corrodedLEFT FLOOR SUPPORT NR 2 IS CORRODED. R & R LT FLOOR SUPPORT IAW SRM 51-40-02.SDR SWAA2025111925841Web · corrodedCRACK WEB - INTERCOSTAL LOCATED BTW BS 460 - 480, LBL 24 IN THE FWD CARGO BAY. REPLACED WEB - INTERCOSTAL IAW SRM 51-40-02-0G, DWG 143A7510, SHEET 3, REV B, AND DWG 143A7505, SHEET 81, REV -.SDR SWAA2025111925840Web · corrodedCORROSION WEB SHIELD LOCATED BTW BS 492 - 500A, RBL 24, WL156 IN THE FWD CARGO BAY. REPLACED WEB SHIELD AND FASTENERS IAW SRM 51-40-02-0G-0, 51-10-02, ITEM 9, DWG 143A0080, SHEET 23, REV -.SDR SWAA2025111925844Web · corrodedCORROSION WEB SHIELD LOCATED BTW BS420 - 440, RBL 24 AND WL 156 IN THE FWD CARGO BAY. REPLACED WEB SHIELD AND FASTENERS LOCATED IAW SRM 51-40-02-0G-0, 51-10-02, ITEM 9, & DWG 143A0080, SHEET 23, REV -.SDR SWAA2025111025706Scuff Plate · crackedCRACK FWD CORNER SCUFF PLATE AT AFT CARGO COMPARTMENT. REPAIRED FWD CORNER SCUFF PLATE AT AFT CARGO COMPARTMENT IAW BOEING 737-700 SRM 53-60-15-2R-1 REPAIR 1 PARAGRAPH 4.B. AND BAC 5975.SDR AALA202511056272Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON RIGHT AFT PASSENGER / CREW DOOR CUT OUT LOWER SILL CENTER SHAPE FITTING BETWEEN FR 66 AND FR 68 AT S23R. REPLACED CENTER SHAPE FITTING PER SRM 51-42-11.SDR AALA202601159193Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON PASSENGER CABIN FLOOR STRUCTURE INTERCOSTAL FROM BS 967 TO BS 986.5 AT RBL 17. REPLACED INTERCOSTAL IAW AARD 51-00-05-1.SDR AALA202601147590Floor Support · corrodedAIRCRAFT WAS GROUNDED: CORROSION ON PASSENGER CABIN FLOOR STRUCTURE INTERCOSTAL AT BS 947, RBL 16. REPLACED INTERCOSTAL PER AARD 51-00-05-1.SDR AALA202601140515Floor Support · corrodedAIRCRAFT WAS GROUNDED: CORROSION ON PASSENGER CABIN FLOOR STRUCTURE INTERCOSTAL BETWEEN BS 947 AND BS 967 AT RBL 54. REPLACED INTERCOSTAL PER AARD 51-00-05-1.SDR SWAA2025112025574Support Bracket · crackedCRACK ON SUPPORT BRACKET LOCATED BS 867 BTW STR 2R TO STR 3R AT PASSENGER CABIN. REPLACED SUPPORT BRACKET LOCATED BS 867 BTW STR 2R TO STR 3R AT PASSENGER CABIN AND FASTENERS IAW B737-700 SRM 51-10-02 ITEM 9 AND SRM 51-40-02 AND DWG: 146A7901 SHEET: 66 REV ASDR SWAA2025111925577Web · corrodedCORROSION WEB SHIELD LOCATED BTW BS 847 - 867, RBL 22, WL 156. REPLACED WEB SHIELD IAW SRM 51-10-02-0G-0, ITEM 9, DWG 146A0081, SHEET 37, REV-.SDR SWAA2025110725530Angle · crackedCRACK ANGLE FLOOR STRUCTURE LOCATED BS 695, BL0 . REPLACED THE ANGLE IAW SRM 51-40-02, AND DWG 273A9110, SHEET 6, REV A.SDR ASAA2025101861786Channel · corrodedFORWARD CARGO COMPARTMENT,R/H SIDEPLATE CHANNEL HAS MULTIPLE AREAS OF CORROSION (RBL22,STA 500E-500I). GROUNDED - YES. REMOVED & REPLACED R/H SIDEPLATE CHANNEL W/ NEWLY FABRICATED PIECE IAW BOEING DWG# 143A7501 REV.A B737NG S.R.M. 53-00-53-2R-5 DUE TO CORROSIOSDR LR7A2025101803791Stanchion · crackedAFTER SCHEDULED FLIGHT FOUND RH STANCHION AT FS 858 LOWER FITTING CRACKED / REPAIR BY REPLACEMENT, REPLACED RH STANCHION LOWER FITTING AT FS858 REF SMP 583 51-70. LP# 60690SDR DALA2025102007671Support Angle · damagedTOOLING DAMAGE ON SUPPORT ANGLE AFT SIDE OF FRAME 62 I/B OF STR 2 LT. REPAIRED PER ERA 628177-14. (1258085)SDR DALA2025102007670Angle · damagedTOOLING DAMAGE ON ANGLE FITTING AFT OF FRAME 62 JUST O/B OF STR 1LT. REPAIRED PER ERA 628177-14. (1258083)SDR DALA2025102007637Support Angle · crackedCRACK SUPPORT ANGLE ON FR 69 AND STR 24R IN AFT CARGO COMPARTMENT. REPLACED SUPPORT ANGLE AND FASTENERS LOC. ON FR 69 AND STR 24R IN AFT GALLEY AREA AS PER A319 SRM 51-42-11 AND SRM 51-72-11. (1259068).SDR AALA202510206400Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON LEFT AFT PASSENGER / CREW DOOR CUT OUT LOWER SILL AFT CORNER SHAPE FITTING AT FR 68 AND S23L. REPLACED CORNER SHAPE FITTING PER SRM 51-72-11.SDR DXTR2025101801Support · crackedLH FWD WHEEL WELL FAIRING SUPPORT FRAME P/N 6910269-49 CRACKED AT RIVET.... EDDY CURRENT NDT INSPECTION PERFORMED BY TOLEDO JET CENTER, CRS# 2TJR420B. CRACK TIP(S) IDENTIFIED ON ARTICLE, COMPLETED STEPS 1-18 OF RFTS-115292 REV. 0 (DRAFT). FABRICATED -001 DOUBSDR HNAA2024112000768Floor Support · corrodedRIGHT FLOOR SUPPORT NR 2 IS CORRODED. REMOVED AND REPLACED THE RT FLOOR SUPPORT IAW SRM 51-40-02.SDR HNAA2025112000767Floor Support · corrodedLEFT FLOOR SUPPORT NR 3 IS CORRODED. R & R THE FLOOR SUPPORT IAW SRM 51-40-02.SDR HNAA2025112000765Floor Support · corrodedCENTER OMEGA BEAM GUSSET NR 1 HAS CORROSION. R & R CENTER OMEGA BEAM GUSSET IAW SRM 51-40-02.SDR HNAA20252000764Floor Support · corrodedLEFT OMEGA BEAM GUSSET NR 3 IS CORRODED. R & R LT OMEGA BEAM GUSSET IAW SRM 51-40-02.SDR HNAA2025112000763Floor Support · corrodedCENTER FUSELAGE III INTERNAL CENTER LT FLOOR GUSSET BETWEEN FR 35 - 39 CORRODED. R & R CENTER FUSELAGE III INTERNAL CENTER LT FLOOR GUSSET BETWEEN FR 35 - 39 IAW SRM 51-40-02.
Back to JASC 5320