JASC 5320
Service difficulty reports · 216,095
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR JJBA20251008034Floor Support · crackedCFII, LH OMEGA BEAM INBD VERTICAL FLANGE FOUND CRACKED AT FR 26. REPAIR DOUBLER ON CFII, LH OMEGA BEAM, ON INBD VERTICAL FLANGE AT FR26SDR JJBA20251008033Floor Support · crackedCFII, LH OMEGA BEAM INBD VERTICAL FLANGE FOUND CRACKED AT FR31. REPAIR DOUBLER ON CFII, LH OMEGA BEAM, ON INBD VERTICAL FLANGE AT FR31SDR JJBA20251008032Floor Support · crackedCFI, LH OMEGA BEAM INBD VERTICAL FLANGE FOUND CRACKED AT FR21. REPAIR DOUBLER ON CFI, LH OMEGA BEAM, ON INBD VERICAL FLANGE AT FR 21.SDR JJBA20251008031Floor Support · crackedCFII, LH OMEGA BEAM INBD VERTICAL FLANGE FOUND CRACKED AT FR34. REPAIR DOUBLER ON CFII, LH OMEGA BEAM, ON INBD VERTICAL FLANGE AT FR34SDR JJBA20251008029Floor Support · crackedLH OMEGA BEAM INBD VERTICAL FLANGE FOUND CRACKED AT FR25. REPAIR DOUBLER ON CFII, LT OMEGA BEAM, ON INBD VERTICAL FLANGE AT FR 25SDR JJBA20251008026Floor Support · crackedCFI, LH OMEGA BEAM INBD VERTICAL FLANGE FOUND CRACKED AT FR22. REPAIR DOUBLER ON CFI, LH OMEGA BEAM, ON INBD VERICAL FLANGE AT FR 22SDR AALA202510074803Floor Support · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN PASSENGER CABIN FLOOR STRUCTURE INTERCOSTAL AT BS 354, S17L, LBL 11. REPLACED INTERCOSTAL PER AARD 51-00-05-1.SDR CALA2025100609640Intercostal · crackedWHILE PERFORMI ING REPAIR FOR NRTN 1333882 DISCOVERED CRACK COMMON TO MATING 14 6N5425-37 INTER COSTAL WEB. REMOVE WEB, REMOVE STIFFENERS COMMON TO WEB, FABRICATE WEB LOCATE DRILL TREAT PRIME REINSTALL ESDR REPORTING REMOVED 02 STIFFENERS AND 02 CLIPS FROM INSDR CALA2025100609639Intercostal · gougedMAIN E&E ACCESS DOOR CUTOUT BETWEEN FR460- FR480/S29R INTERCOSTAL I/B SURFACE GOUGED. DIT 95-15. REMOVED AND REPLACED INTERCOSTAL AT MAIN E&E ACCESS DOOR CUT OUT BETWEEN FR460-FR480 S21R.SDR DALA2025100207172Floor Support · corrodedSHIP 5801 CORROSION ON FLOOR STRINGER (UPPER AND LOWER SIDES) RBL. 7.55 BTW STA 1365 TO 1395 AT AFTER CARGO COMPARTMENT (C2). CORRECTIVE ACTION: SUMMARY OF NRC 00519. CORROSION LEVEL 2. FLOOR STRINGER (UPPER AND LOWER SIDES) RBL. 7.55 BTW STA 1365 TO 1395 AT ASDR DALA2025100107130Bracket · damagedTOOLING DAMAGE ON BRKT FWD SIDE OF FRAME 62 BTWN STR P'2 AND P'3. REPLACED BRACKET IAW AIRBUS DRAWING F5347982002400 AND SRM 53-11. (1228062)SDR SWIA2025121900930Intercostal · corrodedINTERCOSTALS FOUND TO BE SEVERELY CORRODED ON MORE THAN ONE ELEMENT REQUIRING REPLACEMENT. REMOVED AND REPLACED THE INTERCOSTALS IAW SRM 51-42-06, AND 51-42-21 06. COMPLETED TASK CARD 51-900-1003-SKY. REFERENCE CONTINUATION CARD FOR WORK PERFORMED.SDR SWIA2025120100930Floor Support · corrodedUPON REMOVAL OF SEAT TRACK FOUND CORROSION ON FLOOR SUPPORT LBL9, FS549. REPAIRED THE FLOOR SUPPORT BS 533 - 581 IAW SRM 53-00-41-201-001-A01, SRM 51-42-06-001-001-A01, SRM 51-42-21-001-001-A01, & DWG: SH670-33415 REV E.SDR ASAA2025093061977Shear Web · corrodedAFT WET SHEAR WEB AT STA 907 HAS CORROSION AT RBL 60. GROUNDED - YES. UPPON FURTHER EVALUATION FOUND TO HAVE NO ALLOWABLE LIMITS FABRICATED AND REPLACED AFT WET SHEAR WEB ON STA 907 TO STA 927 AND RBL 60 IAW B737-700 SRM 51-40-02-09-0W= 125 O= .071 R= .065 L= SDR SWAA2025110319909Intercostal · crackedCRACK WEB INTERCOSTAL LOCATED BETWEEN BS 294.5 - 303.9, S16L. PERFORMED A MAJOR REPAIR ON WEB INTERCOSTAL IAW EA 25-153-02714-WIP1, TTG8Q015JTW1 AND EA 25-153-02714, TTG8Q015TCU5.SDR SWAA2025110319906Strap · corrodedCORRODED STRAP, FLOOR STRUCTURE LOCATED BETWEEN BS 1016 TO 1040, LBL 4, WL 208.1. REPLACED THE STRAP IAW SRM 51-40-02, SRM 51-10-02, ITEM 9, AND DWG 147A5600, SHEET 32, REV B.SDR SWAA2025103019746Floor Support · crackedCRACKED FLOOR SUPPORT BS 328 - 344, LBL 46 REPLACED THE FLOOR SUPPORT IAW SRM 51-10-02, ITEM 9, AND SRM 51-40-02, DRAWING 141A5400, SHEET 44, REV-.SDR SWAA2025103019745Floor Support · crackedCRACKED FLOOR SUPPORT LOCATED BETWEEN BS 312 - 328, LBL 46. REPLACED FLOOR SUPPORT IAW SRM 51-40-02, SRM 51-10-02, AND DWG 141A5400, SHEET 26, REV-.SDR SWAA2025103019912Strap · corrodedCORROSION STRAP FLOOR STRUCTURE LOCATED BETWEEN STA1016 TO STA1040 AND RBL18 WL208.1. REPLACED STRAP FLOOR STRUCTURE IAW SRM 51-40-02; SRM 51-10-02 ITEM 9 AND DWG 147A5730 SHEET 23 REV C.SDR SWAA2025103019891Support Angle · elongatedAFT CARGO COMPARTMENT BULKHEAD; SUPPORT ANGLE HAS SEVERAL FASTENERS HOLES ELONGATED; BTW STA 867 AND STA 947. REPLACED SUPPORT ANGLE LOC. AFT CARGO COMPARTMENT BULKHEAD; ON BTW STA 867 AND STA 947 IAW SRM 51-40-02.SDR SWAA2025102719390Threshold · crackedFORWARD CARGO BAY AFT CORNER THRESHOLD IS CRACKED. REPAIRED FORWARD CARGO BAY AFT CORNER THRESHOLD IAW SRM 53-30-15-2R-1.SDR AALA202510266232Shield · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CARGO COMPARTMENT SHIELD ASSEMBLY LOCATED FROM BS 767 TO BS 787 AT RBL 20. REPLACED SHIELD PER AARD 51-00-05-1.SDR ASAA2025093061673Strap · corrodedAFT WET INTERCOSTAL STRAP AT STA 1016 TO 1026 HAS CORROSION AT LBL 3. GROUNDED - YES. REMOVED DAMAGE FOUND TO BE OUT OF LIMITS, REMOVED AND REPLACED AFT WET TINERCOSTAL STRAP AT STA 1016 TO 1026 IAW B737-700 SRM 51-40-02-OG-O.W= 1.25 O= .080 R= .069 L= 2.25 D=SDR ASAA2025093061662Shear Web · corrodedAFT WET IN/BD SHEAR WEB AT STA 847 TO 905 HS CORROSION AT RBL 45. GROUNDED - YES. AFT WET IN/BD SHEAR WEB AT STR 847 TO 905 HAS NO ALLOWABLE LIMITS. REMOVED AND REPLACED IAW B737-700 SRM 51-40-02-0G-0W= 1.25 O= .071 R= .00 L= 2.25 D= .071.SDR ASAA2025093061661Floor Support · corrodedAFT WET FLOOR SUPPORT AT STA 947.5 TO 967 RBL 60 HAS CORROSION. GROUNDED - YES. AFT WET FLOOR SUPPORT FOUND TO HAVE NO ALLOWABLE LIMITS. REMOVED AND REPLACED IAW BOEING 737-700 SRM 51-40-02-0G-0. W= 1.25 O= .080 R= .068 L= 2.75 D= .012.SDR AALA202510206309Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON PASSENGER CABIN FLOOR STRUCTURE INTERCOSTAL AT BS 947.5, RBL 54. REPLACED INTERCOSTAL PER SRM 53-70-51-2R-5.SDR AALA202510205659Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CARGO COMPARTMENT TRANSITION PANEL AT BS 737 PLUS 2 INCHES, AT LBL 24. REPAFIRED TRANSITION PANEL PER SRM 53-00-53-2R-5.SDR ASAA2025093061558Web · corrodedAFT WET O/B SHEAR WEB AT STA 847 TO 905 HAS CORROSION AT RBL 60. GROUNDED - YES. UPON FURTHER EVALUATION FOUND TO HAVE NO ALLOWABLE LIMITS, REPLACED AFT WET O/B SHEAR WEB AT STA 847 TO 905 AND RBL 60 IAW B737-700 SRM 51-40-02-0G-0W=1.25 O=.071 R=.058 L= 2.25 DSDR IPXA2025100313786Stiffener · crackedMDC FLOOR, R/H SIDE, BTW FR 38.1 AND FR 38.2, DOG BONE SUPPORT BROKEN. REMOVED AND REPLACED THE DOG BONE SUPPORT BTW FR 38.1 AND FR 38.2 R/H SIDE IAW SRM 51-40-21.SDR IPXA2025100313780Stiffener · crackedMDC FLOOR, R/H SIDE, BTW FR 37 AND FR 38, DOG BONE SUPPORT BROKEN. REMOVED AND REPLACED THE DOG BONE SUPPORT BTW FR 37 AND FR 38 R/H SIDE IAW A300-600 SRM 51-40-21.SDR CALA2025100309590Strap · corrodedDURING REMOVAL APU INLET DOOR, FOUND AFT CUTOUT STRAP WITH CORROSION (MARKED IN RED). DOT 34-024. REFERENCE N/R 134237 ESFR ENTRY REMOVED/REPLACED 2 EACH APU CUTOUT STRAPS FILLERS IAW SRM 53-80- 15-2R-1 PARTS FABRICATED IAW SRM 53-80-15-2R-1 TAB 201/202 DETAI SDR CALA2025100309586Gusset · crackedFOUND GUSSET CRACKED INNER RADIUS FWD CARGO COMPARTMENT AT S-21R STA 500I. REMOVED AND REPLACE GUSSET AT FWD CARGO COMPARMENT STR 21R STA 500I AS PER REF B737 SRM 51-40-02-0G-0 AND DWG # 143A7902.SDR N6WA2025100308Intercostal · corrodedCORROSION ON INTERCOSTAL BETWEEN FS310-FS333 AT STGR21L. REMOVED AND REPLACED INTERCOSTAL BETWEEN FS310-FS333 AT STGR21L IAW CRJ SRM 51-42-06SDR N6WA2025100307Intercostal · corrodedCORROSION ON INTERCOSTAL BETWEEN FS333-FS349 AT STGR21L. REMOVED AND REPLACED INTERCOSTAL BETWEEN FS333-FS349 AT STGR21L IAW CRJ SRM 51-42-06SDR N6WA2025100306Intercostal · corrodedCORROSION ON INTERCOSTAL BETWEEN FS333-FS349 AT STGR20R. REMOVED AND REPLACED INTERCOSTAL BETWEEN FS333-FS349 AT STGR20R IAW CRJ SRM 51-42-06SDR N6WA2025100304Intercostal · corrodedCORROSION ON INTERCOSTAL BETWEEN FS310-FS319 AT STGR20R. REMOVED AND REPLACED INTERCOSTAL BETWEEN FS310-FS319 AT STGR20R IAW CRJ SRM51-42-06SDR N6WA2025100303Strap · corrodedCORROSION ON PANEL 195AB FWD STRAP. REMOVED STRAP AND MANUFACTURED NEW STRAP AND INSTALLED ON PANEL 195AB IAW CRJ SRM 51-42-13SDR N6WA2025100207Floor Support · corrodedCORROSION AT RH FLOOR SILL BETWEEN FS280-FS310. REMOVED AND REPLACED RH FLOOR SILL AT FS280-FS310 IAW CRJ SRM 51-42-06SDR CALA2025100109512Floor Support · corrodedCABIN FLOOR STRUCTURE FLOOR SUPPORT Y 765 CORRODED AT FR 66. REMOVED FLOOR SUPPORT Y765 FR66 - 70 IAW SRM 51-72-11-911-001 REV.154, REPLACED FLOOR SUPPORT IAW SRM 51-72-1 1-911-001 REV 154.SDR N6WA2025100108Bracket · corrodedCORROSION ON MACHINED BRACKETS BETWEEN FS565-FS597 IN FWD CARGO. REMOVED AND REPLACED BRACKET BETWEEN FS565-FS597 IAW CRJ SRM 51-42-20SDR N6WA2025100101Intercostal · corrodedINTERCOSTAL AT STRINGERS 27R & 27L CORRODED. REMOVED AND REPLACED THE INTERCOSTAL AT S27R-27L IAW SRM 51-42-06. REPAIRED IAW EO C550-53MR-O AND AWATS EO 25-CRJ5-53MR-098SDR SWIA2025112400929Angle · bentANGLE AT BS 1031, S18 FOUND BENT WITH A RIVET SHEARED. FOUND TO BE BENT AND CRACKED, REMOVED AND INSTALLED A NEW ANGLE IAW SRM 51-42-06-001-001-A01, SRM 51-42-21-001-001-A01 REVISION 38, AND DWG MM670-36023, REV B. COMPLIED WITH ALL STEPS OF TASK CARD 51-900-1SDR SWAA2025110519259Support Angle · corrodedCORROSION ANGLE - SUPPORT LOCATED STA 500I BTW STR 24L TO STR 26L AND WL 156 AT FWD CARGO. REMOVED DAMAGE AND EVALUATED REWORK AREA (3 EA) ON ANGLE - SUPPORT LOCATED STA 500I BTW STR 24L TO STR 26L AND WL 156 IAW SRM 53-30-08-1A-1 ALLOWABLE DAMAGE 1 PARAGRAPHSDR SWAA2025110519413Support Angle · crackedCRACK CARGO LINER SUPPORT ANGLE, CEILING AREA, BS 727J, LBL 50. REPAIRED THE SUPPORT ANGLE IAW SRM 51-70-11-2R-0.SDR SWAA2025110519256Gusset · crackedCRACK GUSSET ANGLE, BS 500I, STRINGER 21L. REPLACED THE GUSSET ANGLE IAW SRM 51-40-02-0G-0, SRM 51-10-02-0G-0, ITEM 9, AND DWG 143A7902, SHEET 256, REV B.SDR SWAA2025110519411Floor Support · corrodedCORROSION ON FLOOR SUPPORT BTW BS 947.5 - 967, RBL 48, WL 208.1. REPLACED THE FLOOR SUPPORT AND FASTENERS IAW SRM 51-40-02, SRM 51-40-02, ITEM 9, & DWG 147A5650, SHEET 71, REV A.SDR SWAA2025110519412Floor Support · corrodedCORROSION ON FLOOR SUPPORT BTW BS 947.5 - 967, LBL 49, WL 208.1. REPLACED THE FLOOR SUPPORT IAW SRM 51-10-02-0G-0, ITEM 9, AND DWG 147A5660, SHEET 55, REV A.SDR SWAA2025110319524Angle · crackedCRACKED ANGLE, BS 695, BL 0. REPLACED ANGLE AND FASTENERS IAW SRM 51-40-02-0G-0, SRM 51-10-02, ITEM 9, AND DWG 273A9110, SHEET 6, REV A.SDR SWAA2025110331274Angle · crackedCRACKED ANGLE, FLOOR STRUCTURE, BS 695, BL 0. REPLACED ANGLE AND FASTENERS IAW SRM 51-40-02-0G-0 SRM 51-10-02 ITEM 9 AND DWG 273A9110, SHEET 6, REV.A.SDR SWAA2025110319520Angle · crackedCRACKED ANGLE, FLOOR STRUCTURE. BS 695, RBL 24.75. REPLACED THE ANGLE IAW SRM 51-40-02, SRM 51-10-02, ITEM 9, DWG 273A9110, REV A, & DWG 111A6000, SHEET 302, REV-.
Back to JASC 5320