JASC 5320
Service difficulty reports · 216,095
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2025081186545Gusset · crackedCRACK GUSSET STA 500D STR 19L FWD CARGO COMPARTMENT. REPLACED GUSSET LOC. STA 500D STR 19L FWD CARGO COMPARTMENT IAW B737-700 SRM 51-10-02-0G STEP 9; SRM 51-40-02-0G-0 AND DWG 143A7902 SHEET 209 REV -.SDR CALA2025070806331Angle · corrodedAPU COMPARTMENT LEFT SIDE LOWER TORQUEBOX BEAM ANGLE CORROED ON OUTBOARD SIDE NEAR 2ND FROM AFT NUT PLATE (9"FWD OF AFT BULKHEAD ). REMOVED AND REPLACED APU COMPARTMENT LEF SIDE LOWER TORQUE BOX B EAM ANGLE IAW SRM 51-10-02-0G-0,51-40-02-0G-0, 51-40-05 -0G-0SDR VNAA20250629004Floor Support · corrodedFLOOR SUPPORT ANGLES CORRODED AT PAX DOOR BETWEEN FS 310.00 AND 349.00. REMOVED AND REPLACED IAW CRJ 900 SRMS 51-40-11-001-001-A01 AND 51-42-06-001-001-A01SDR VNAA20250629003Intercostal · corrodedAVI DOOR INTERCOSTAL IS CORRODED BETWEEN STGR 25R TO STGR 26R. ADDITION CORROSION (PITTING) WAS DISCOVERED ON STRINGER 26R. REMOVED CORROSION IAW CRJ 900 SRM 51-21-06-001-001-A01. REPAIRED BLENDED AREA IAW REO 690-53-21-1944 REV – DATED 5-10-2025. REPAIR DOCSDR VNAA20250629002Intercostal · corrodedAVI DOOR INTERCOSTAL IS CORRODED BETWEEN STGR 27 TO STGR 26R. REMOVED FASTENERS FROM BRACKETS, SKIN, AND INTERCOSTAL STRING 27. REMOVED INTERCOSTAL STRING 27 FROM AVI DOOR INTERCOSTAL. IAW CRJ900 SRM 51-42-06-001-001-A01 AND 51-42-06-001-001-A01. MATCH DRILLSDR AALA202508015973Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK SHEAR PLATE STR 23 R LOC. BTW FR69 AND FR70 AT AFT GALLEY AREA MEASURES OF CRACK IS L=0.812. MAINTENANCE REPLACED SHEAR PLATE LOC. STR 23 R BTW FR69 AND FR70 AT AFT GALLEY AREA I.A.W A319 SRM 51-42-11-801 AND DWG D53474180.SDR AALA202507301363Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION FLOOR BEAM -Y765 BTW FR64 AND FR65 AT AFT GALLEY AREA MEASURES OF CORROSION ARE L= 1.62 IN, W= 0.621 IN, D= 0.0405 IN. MAINTENANCE REPLACED FLOOR BEAM AND FASTENERS LOC. AT LEVEL FR64 TO FR 66 -Y765 AT AFT GALLEY AREA ISDR SWAA2025072986452Web · crackedCRACK WEB LOCATED BTW BS927 TO BS947.5 AND RBL21 AT AFT CARGO COMPARTMENT INSTALLED WEB-INTERCOSTAL AND FASTENERS LOCATED BTW BS927 TO BS947.5 AND RBL21 AT AFT CARGO COMPARTMENT IAW SRM 51-40-02 AND DWG 147A7500 SHEET 27 REV-.SDR SWAA2025072986450Support Angle · crackedCRACK ANGLE LOCATED BTW BS 907 TO BS 927 AND BTW S25R TO S27R AT AFT CARGO COMPARTMENT. REPLACED SUPPORT ANGLE BETWEEN BS 907 TO BS 927 STR 25R AND STR 27R AT AFT CARGO COMPARTMENT IAW SRM 51-10-02-0G, PARAGRAPH 9, SRM 51-40-02-0G, AND DWG 147A7221, SHEET 24,SDR SWAA2025072986451Support Bracket · crackedCRACK SUPPORT BRACKET LOCATED BS947.5 AND LBL11 AT AFT CARGO COMPARTMENT. REPLACED SUPPORT BRACKET AND FASTENERS LOCATED BS947.5 AND LBL11 AT AFT CARGO COMPARTMENT IAW SRM 51-40-02, SRM 51-10-02, AND DWG 149A8103, SHEET 7, REV A.SDR AALA202507285101Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION FLOOR SUPPORT -Y765 LOC AT LEVEL FR70 AT AFT GALLEY AREA CORRODED AREA IS L=1.66 IN, W=1.33 IN, D=0.0298 IN MAINTENANCE REPLACED FLOOR SUPPORT -Y765 LOC ON FR66 TO FR70 AT AFT GALLEY AREA IAW A319 SRM 51-42-11-801 AND DWSDR AALA202507289662Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION FLOOR BEAM -Y160 LOC AT LEVEL FR68 TO FR70 AT AFT GALLEY AREA CORRODED AREA L=1.209 IN W=0.945 IN D=0.029 IN. MAINTENANCE REPLACED FLOOR BEAM -Y160 LOC. FROM FR68 TO FR70 ON AFT GALLEY AREA IAW A319 SRM 51-42-11-801 ANDSDR AALA202507219632Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION FLOOR BEAM -Y1162.5 BTW FR68 AND FR69 AT AFT GALLEY AREA , MEASURES ARE: L= 1.08 IN, W= 0.972 IN, D= 0.0215 IN. MAINTENANCE REPLACED FLOOR BEAM -Y1162.5 BTW FR68 AND FR69 AT AFT GALLEY AREA IAW A319 SRM 51-72-11-911-00SDR AALA202507210865Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: AIRCRAFT IN BASE MAINTENANCE: CORROSION FLOOR BEAM -Y1292 BTW FR65 AND FR66 AT AFT GALLEY AREA MEASURES ARE: L= 1.141 IN, W= 0.884 IN, D= 0.0245 IN. MAINTENANCE REPLACED FLOOR BEAM -Y1292 BTW FR64 AND FR66 AT AFT GALLEY AREA IAWSDR AALA202507141660Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOOR BEAM +Y1292 BTW FR65 AND FR66 AT AFT GALLEY AREA L= 3.43 IN, W= 2.00 IN, D= 0.0230 IN. MAINTENANCE REPLACED FLOOR BEAM Y1292 LOC BTW FR64 AND FR66 AT AFT GALLEY AREA IAW A319 SRM 51-42-11-801 A319 SRM 51-72-11SDR JJBA20250711028Floor Support · corrodedBETWEEN LH OB FLOOR SUPPORT AND IB FLOOR SUPPORT AT FRAME 44 IS CORRODED. REMOVED CORROSION BETWEEN LH OB FLOOR SUPPORT AND IB FLOOR SUPPORT AT FRAME 44. RECEIVED, LOCATED, DRILLED AND INSTALLED NEW PARTSDR SIMA20250628002Floor Support · corrodedFWD GALLEY STRUCTURE FR 12-14 RH FLOOR SILL HAS 3 AREAS OF CORROSION SSI 53-10-027 (LEVEL 2 CORROSION) RAR THE FWD GALLEY RH FLOOR SILL IAW ERJ 170 SRM 51-40-08SDR AALA202507080347Floor Support · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN PASSENGER CABIN FLOOR STRUCTURE INTERCOSTAL FROM BS 277 TO BS 294, AR BL 0. REPLACED INTERCOSTAL PER AARD 51-00-05-1.SDR AALA202506305958Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED AFT CABIN FLOOR SHEAR PLATE BETWEEN FR 69 AND FR 70 AT S23L. REPLACED SHEAR PLATE PER SRM 51-72-11.SDR AALA202506304238Stiffener · crackedAIRCRAFT IN BASE MAINTENANCE: FORWARD CARGO AFT BULKHEAD LEFT HAND CENTER VERTICAL STIFFENER CRACKED. AT FR 35.6 AND LBL 41. REPLACED VERTICAL STIFFENER PER SRM 53-24-14.SDR R61A2025062800271Bracket · corrodedDURING HEAVY CHECK FWD. CARGO DOOR LOWER CUT OUT FOUND CORRODED TRIM BRACKET. REPLACED BRACKET IAW SRM 51-41-01SDR R61A2025062800267Web · corrodedDURING HEAVY CHECK FWD. WET AREA RH WEB FOUND CORRODED. REPLACED WEB IAW SRM 51-40-08SDR R61A2025062800266Floor Support · corrodedDURING HEAVY CHECK FWD WET AREA LH SIDE FR16 AND IBL44 SUPPORT FLOOR FOUND CORRODED. REPLACED SUPPORT IAW SRM 51-43-03SDR JJBA20250806001Gusset · corrodedMIDDLE GUSSET BTW FR 18-23 FOUND CORRODED. AT CF1 MIDDLE GUSSET BTW FR 18-23 GUSSET FOUND CORRODED OUT OF LIMIT. GUSSET REMOVED. MIDDLE GUSSET BTW FR 18-23 REPLACED.SDR SWAA2025071686107Bracket · crackedG1 BRACKET ASSY IS CRACKED.SDR SWAA2025071586199Web · corrodedCORROSION ON UPPER WEB LOCATED BTW BS460 TO BS480 RBL70 WL197 AT FWD CARGO COMPARTMENT. REPLACED UPPER SILL WEB LOCATED BTW BS440 TO BS494 AT LEVEL STR18R RBL70 WL197 AT FWD CARGO COMPARTMENT I.A.W B737-700 SRM 41-40-02 AND DWG 143A8111 SHEET 12 REV-A. 143A00SDR REXA2025071500737Bracket · corrodedINITIAL INSPECTION': CORROSION ON HYDRAULIC LINES SUPPORT PLATES 3EA (IN BK, LG EXT, LG RET), TWO LOCATED ON 45RBL/45LBL AND THE OTHER LOCATED ON 35LBL AT RH/LH WHEEL WELL AREA CORROSION ON SUPPORT PLATE LBL35 WAS REMOVED AND EVALUATED WITHIN LIMITS, PER CRJSDR REXA2025071500730Bracket · corrodedINITIAL INSPECTION': CORROSION ON HYDRAULIC LINES SUPPORT PLATES 3EA (IN BK, LG EXT, LG RET), TWO LOCATED ON 45RBL/45LBL AND THE OTHER LOCATED ON 35LBL AT RH/LH WHEEL WELL AREA CORROSION ON SUPPORT PLATE LBL35 WAS REMOVED AND EVALUATED WITHIN LIMITS, PER CRJSDR JJBA20250711014Floor Support · corrodedRH RBL 48 FRAME 52 FLOORSILL CORRODED. REMOVED CORROSION RH RBL 48 FRAME 52 FLOORSILL FOUND TO BE OUT OF LIMITS. LOCATED, DRILLED AND INSTALLED NEW SILL.SDR DALA2025070104882Web · corroded(LOG 1050329) CORROSION ON WEB FLOOR SUPPORT STA 986 TO 992 AND 34 TO 35 LBL, AT W2. WEB FLOOR SUPPORT STA 986 TO 992 AND 34 TO 35 LBL, AT W2 WAS REPLACED PER B737-800 SRM 51-40-02-0G.SDR FDEA202506271068Strap · corrodedDOT 86-117 AFT CARGO STA 1420, STABILIZER STRAP IN CEILING AT RBL 45, CORRODED. REMOVED STABILIZER STRAP IN CEILING AT RBL 45 AND PEFORMED REPAIR IAW SRM 53-00-51-2R, FABRICATED STRAP ON VTMAE TRAVELER # T25/1820128 IAW SRM 53-00-51-2R, MAJOR REPAIR.SDR CALA2025063006071Panel · corrodedAFT CARGO FR 58 LSTR 38-RSTR 41 PROFILE PANEL IS CORRODED AND LO OSE. GENERATED BY V798788 ON HAECO LCQ NR 9296674 / 20674 ESFR INFORMATION UPDATE REMOVED AND REPLACED PROFILE FROM AFT CARTGO FR58 STR38-STR41 IA W A319 SRM 51-42-11-001 ACMP BY MECH V932196 INSSDR CALA2025063006067Floor Support · corrodedFWD CARGO LH PROFILE FR 25-28 CORRODED. REMOVED AND REPLACED PROFILE PANEL AT FWD CARGO FR25-28 LH IAW A 319 SRM 51-42-11-001.SDR CALA2025063006064Bracket · crackedFWD CARGO, BETWEEN STA.845 TO STA.879, RH SIDE AIR FILTER, STRUCTURE, FWD/LOWER BRACKET SUPPORT IS DEFORMED. SDR REPROTING PURPOSE ONLY STRAIGHTENED RH SIDE AIR FILTER STRUCTURE IAW BAC 5300-2 AND PERF ORMED HFEC ON AREA, CRACK FOUND, CRACKED BRACKET WAS REMOVSDR CALA2025063006063Intercostal · crackedRT FWD EMERGENCY EXIT DOOR INTERCOSTAL CRACKED. R & R WITH NEW INTERCOSTAL D522790620451, ON RT FWD EMERGENCY EXIT DOOR IAW A320 SRM 51-42-11/001 AND 51- 72-11-911-001.SDR FDEA202506271067Support · corrodedAFT CARGO COMPARTMENT CEILING SUPPORT HAS CORROSION BETWEEN BS 1400.0 TO BS 1420.0 RBL 24.75.SDR FDEA202506271066Support · corrodedAFT CARGO COMPARTMENT CEILING PANEL SUPPORT HAS CORROSION BETWEEN BS 1400.0 TO BS 1420 RBL 45.50.SDR DALA2026031101702Scuff Plate · corrodedAFT CARGO DOOR, LOWER SCUFF PLATE FASTENER HOLES 11OL, 10OL, 9OL, 8OL, 7OL, 6OL, 5OL, 4OL, 3OL, 2OL, AND 1OL HAVE CORROSION. REMOVED CORROSION, EVALUATED AREA ON AFT CARGO DOOR LOWER SCUFF PLATE, FOUND OUT OF LIMITS IAW A220 ASRP J51-21-06, J53-61-01. RESTOREDSDR DALA2026031101701Scuff Plate · corrodedFWD CARGO DOOR, LOWER SCUFF PLATE FASTENER HOLES 11OU AND 10OU HAVE CORROSION. REMOVED CORROSION, EVALUATED AREA ON FWD CARGO DOOR UPPER SCUFF PLATE, FOUND OUT OF LIMITS IAW A220 ASRP J51-21-06, J53-21-01. RESTORED FINISH AND ACCOMPLISHED ALL WORK IAW DELTA ERSDR DALA2026031101699Scuff Plate · corrodedR1 DOOR SCUFF PLATE FASTENER HOLES 15OL, 14OL, 13OL, 12OL, 11OL, 5OL, 3OL, AND 1OL HAVE CORROSION. REMOVED CORROSION, EVALUATED AREA ON R1 DOOR SCUFF PLATE, FOUND OUT OF LIMITS IAW A220 ASRP J51-21-06, J53-21-01. RESTORED FINISH AND ACCOMPLISHED ALL WORK IAW DSDR K11A2025080800338Stiffener · corrodedEVIDENCE OF CORROSION ON BOTTOM SECTION OF VERTICAL STIFFENER ON FWD SIDE OF STA 227 BULKHEAD BL0SDR SIMA20250626014Support · corrodedFRAME 76 SHEAR CLIP BETWEEN STRINGERS 29R-29L IS CORRODED. REMOVED AND REPLACED SHEAR CLIP AT FR 76 BTW STGR 29R-29L IAW SRM 51- 40-08.SDR SWAA2025072985850Intercostal · crackedCRACKED ON INTERCOSTAL AT BS 393; RBL 10; WL 208. REMOVED AND REPLACED INTERCOSTAL BS380-BS400 RBL8.2 WL208 I.A.W SRM 51-10-02-0G-0 PAR 9.C; SRM 51-40-02-0G-0 AND DWG 143A5400 REV:A.SDR SWAA2025072985837Scuff Plate · crackedFWD ENTRY DOOR FWD LOWER SCUFF PLATE IS CRACKED ON AFT EDGE. REPAIRED CRACKED FED FWD SCUFF PLATE PER EA 25-153-01771-WIP1; ACCOMPLISHED ON TASK ID TTG8Q013H6V.SDR SWAA2025072985834Scuff Plate · crackedAFT CARGO BAY AFT CORNER SCUFF PLATE IS CRACKED. REPAIRED IAW SRM 53-60-15-2R-1. SCUFF PLATE WILL BE INSTALLED ON CUSTOMER CARD TTG8Q013BV69.SDR SIMA20250626008Shear Beam · corrodedAFT GALLEY FLOOR STRUCTURE, THE LH SHEAR PANEL HAS CORROSION AT MULTIPLE LOCATIONS. FR 87-88. PREVIOUSLY BLUE PAINTED AREA. SSI 53-23-005. (LEVEL 2 CORROSION). BLENDED TO REMOVE CORROSION ON AFT GALLEY FLOOR STRUCTURE LH SHEAR PANEL AT FR 87-88 IAW ERJ 175 SRMSDR SIMA20250626010Gusset · corrodedAFT GALLEY FLOOR STRUCTURE, THE RH CROSS-BEAM GUSSET HAS CORROSION AT FR90. PREVIOUSLY BLUE PAINTED AREA. SSI 53-23-005. (LEVEL 2 CORROSION). BLENDED TO REMOVE CORROSION ON AFT GALLEY FLOOR STRUCTURE RH CROSS-BEAM GUSSET AT FR90 IAW ERJ 175 SRM 51-10-03. THE CSDR SIMA20250626009Shear Panel · corrodedAFT GALLEY FLOOR STRUCTURE, THE CENTER SHEAR PANEL HAS CORROSION AT MULTIPLE LOCATIONS. FR 87-88. PREVIOUSLY BLUE PAINTED AREA. SSI 53-23-005. (LEVEL 2 CORROSION). BLENDED TO REMOVE CORROSION ON AFT GALLEY FLOOR STRUCTURE CENTER SHEAR PANEL AT FR 87-88 IAW ERJSDR SIMA20250626007Floor Support · corrodedAFT GALLEY FLOOR STRUCTURE, THE RH FLOOR SILL HAS CORROSION AT MULTIPLE LOCATIONS. FR 88-90. PREVIOUSLY BLUE PAINTED AREA. SSI 53-23-005. (LEVEL 2 CORROSION). BLENDED TO REMOVE CORROSION ON AFT GALLEY FLOOR STRUCTURE RH FLOOR SILL AT FR 88-90 IAW ERJ 175 SRM 5SDR SWAA2025072285901Strap · crackedCRACK STRAP DOOR CUTOUT LOCATED STA847 AND STR22 AT AFT CARGO COMPARTMENT (2 EA). REPLACED STRAPS IAW SRM 51-40-02-0G, SRM 51-10-02-0G ITEM 9, & DRAWING 146A8201 SHEET 36 REV -.
Back to JASC 5320