JASC 5320
Service difficulty reports · 216,159
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2024113054665Support · crackedAFT CARGO FRAME SUPPORT CRACKED STA 727I RBL 27. GROUNDED - YES. REMOVED AND REPLACED FRAME SUPPORT AT STA 727I RBL 27 IAW B737-800 SRM 51-40-02-0G-0 AND 51-40-05-0G-0.SDR ASAA2024113054664Baffle · crackedFWD CARGO CRACKED BAFFLE STA 500G-500H LH SIDE. GROUNDED - YES. REMOVED AND REPLACED FWD CARGO CRACKED BAFFLE STA 500G-500H LH SIDE IAW B737-800 SRM 51-40-02-0G-0.SDR ASAA2024113054663Angle · crackedFWD CARGO BAFFLE CLIP CRACKED RH STA 500F FWD SIDE. GROUNDED - YES. FWD CARGO BAFFLE CLIP R/H STA 500F FWD SIDE REMOVED AND REPLACED IAW B737-800 SRM 51-40-02-0G-0.SDR DALA2024121711782Channel · corroded(LOG 0713586) CORROSION ON FWD CARGO COMPARTMENT R/H ZEE CHANNEL FROM STA-500A TO STA-500L. REMOVED, FABRICATED 02 EA ZEE CHANNEL SIDE PLATE, 01 EA SPLICE SIDE PLATE AND INSTALLED FROM STA 500A TO STA 500L PER B737 SRM 53-00-53-2R PROCEDURE 5 AND DWG BOEING 14SDR ASAA2024113054521Sill Drain · corrodedAFT WET AREA R2 DOOR MOPSILL HAS CORROSION. GROUNDED - YES. REMOVED DAMAGE, FOUND TO BE OUT OF LIMITS IAW B737-800 SRM 53-70-15-1A-1, REPLACED MOPSILL IAW B737-800 SRM 51-40-02-OG-O W:=2 O:=.080 R:=.070 L:=3 D:=.010.SDR FDEA202411301802Floor Support · crackedM/D FLOOR STRUCTURE FOUND 1EA PROFILE-Z CRACK AT FR80/82, Y300. REINSTALLED THE 1EA PROFILE-Z WITH NEW ONE AT M/D FLOOR SRTUCTURE FR80/82, Y300 I.A.W A300-600F SRM 51-72-10-001, PAGE.2. REPIAR CLASSIFIED AS MINOR PER GMM 6-2-100.SDR FDEA202411301801Support · crackedM/D OVHD COMPT FOUND A HARNESS SUPPORT CRACK AT FR80/82 POSITION. REPLACED THE DAMAGE HARNESS SUPPORT WITH NEW AT M/D OVHD COMPT FR80/82 POSITION. I.A.W A300-600F SRM 51-72-10-001,PAGE 2,REPAIR CLASSIFIED AS MINOR PER GMM 06-2-100.SDR FDEA202411301796Support Bracket · crackedAFT CGO COMPT BILGE AREA 1EA ELECTRICAL WIRE SUPPORT BRACKET CRACK AT FR59 CENTER LINE POSITION. REPLACED THE DAMGE 1EA ELECTRICAL WIRE SUPPORT BRACKET WITH NEW ONE AT AFT CGO COMPT BILGE AREA FR59 CENTER LINE POSITION I.A.W A300-600F SRM 51-72-10-001, PAGSDR FDEA202411301795Support Bracket · crackedBULK CGO COMPT BILGE AREA 1EA ELECTRICAL WIRE SUPPORT BRACKET CRACK AT FR63, S-44R POSITION. REPLACED THE DAMAGE WIRE SUPPORT BRACKET WITH NEW ONE AT BULK CGO COMPT BILGE AREA FR63 S-44R POSITION I.A.W A300-600F SRM 51-72-10-001, PAGE 2 REPAIR CLASSIFIED ASDR DALA2024121311700Cusp Web · crackedCUSP WEB LOCATED BETWEEN Y=218 TO Y=237, BETWEEN X=-56 TO X=-44 WAS FOUND CRACKED. SUMMARY OF NRC 00647: DUE TO CRACKS, NEW CUSP WEB LOCATED AT BETWEEN Y=218 TO Y=237, BETWEEN X=-56 TO X=-44 WAS FABRICATED PER B717-200 SRM 53-00-55-2R PROCEDURE 4 REPAIR 4 FIG SDR ASAA2024113054453Transition Panel · corrodedAFT CARGO RH TRANSITION HAS CORROSION STA 727A TO 767. GROUNDED - YES. REMOVED DAMAGE FOUND TO BE OUT OF LIMITS IAW B737-800 SRM 53-00-53-1A-2, REM,OVED AND REPLACED TRANSITION PANEL IAW B737-800 SRM 51-40-02-0G-0 AND 51-40-05-0G-0 W: 2" O: 0.040" R: .033" L: SDR ASAA2024113054452Floor Support · corrodedAFT WET AREA FLOOR SUPPORT HAS CORROSION STA 950 LBL 20. GROUNDED - YES. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW B737-800 SRM 53-70-51-1A-1 REMOVED AND REPLACED FLOOR SUPPORT IAW B737-800 51-40-02-0G-0 & 51-40-05-0G-0 P/N 147A5676-1 TAG# A277158 W: 2" SDR ASAA2024113054451Floor Support · corrodedAFT WET AREA FLOOR SUPPORT HAS CORROSION STA 950 LBL 20 TO LBL 45. GROUNDED - YES. REMOVED CORROSION FOUND TO BE OUT OF LIMTIS IAW B737-800 SRM 53-70-51-1A-1, REMOVED AND REPLACED FLOOR SUPPORT IAW B737-800 SRM 51-40-02-0G-0 & 51-40-05-0G-0 P/N 147A5676Y5 TAG SDR ASAA2024113054450Floor Support · corrodedAFT WET AREA FLOOR SUPPORT HAS CORROSION STA 947 TO 967 RBL 20. GROUNDED - YES. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW B737-800 SRM 53-70-51-1A-1, REMOVED AND REPLACED FLOOR SUPPORT IAW B737-800 SRM 51-40-02-0G-0 & 51-40-05-0G-0 P/N 147A5676-8 TAG# A2SDR ASAA2024113054449Floor Support · corrodedAFT WET AREA FLOOR SUPPORT HAS CORROSION STA 947 TO 967 LBL 55. GROUNDED - YES. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW B737-800 SRM 53-70-51-1A-1, REMOVED AND REPLACED FLOOR SUPPORT IAW B737-800 SRM 51-40-02-0G-0 & 51-40-05-0G-0 P/N 147A5660Y21 TAG# ASDR ASAA2024113054448Floor Support · corrodedAFT WET AREA FLOOR SUPPORT HAS CORROSION STA 967 TO 986 RBL 20. GROUNDED - YES. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW B737-800 SRM 53-70-51-1A-1, REMOVED AND REPLACED FLOOR SUPPORT IAW B737-800 SRM 51-40-02-0G-0 & 51-40-05-0G-0 P/N 140A9872U10; TAG #SDR ASAA2024113054328Plate · corrodedAFT CARGO R/H TRANSITION HAS CORROSION STA 867-887. GROUNDED - YES. REMOVED DAMAGE ON R/H TRANSITION, FOUND TO BE OUT OF LIMITS IAW B737-800 SRM 53-00-53-1A-2. REMOVED AND REPLACED R/H TRANSITION IAW B737-800 SRM 51-40-02-0G-0. W= 1 O= 0.0040 R= .032 L= 2 D= .SDR ASAA2024113054327Floor Support · crackedFWD WET AREA INTERCOSTAL CRACKED STA 328 TO 344 LBL 48. GROUNDED - YES. REMOVED CRACKED INTERCOSTAL AND INSTALLED NEW INTERCOSTAL IAW B737-800 SRM 51-40-02-0G-0.SDR FDEA202411301782Floor Support · crackedM/D FLOOR STRUCTURE FOUND 1EA SHEAR PLATE CRACK AT FR79 5", Y1600 REPLACED THE DAMAGE SHEAR PLATE WITH NEW ONE AT M/D FLOOR STRUCTURE FR79 5",Y1600 I.A.W A300-600F SRM 51-72-10-001,PAGE 2,REPAIR CLASSIFIED AS MINOR PER GMM 06-2-100SDR FDEA202411301781Floor Support · crackedM/D FLOOR STRUCTURE FOUND 1EA SHEAR PLATE CRACK AT FR79 5", -Y1600 REPLACED THE DAMAGE SHEAR PLATE AT M/D FLOOR STRUCTURE FR79 5", -Y1600 I.A.W A300- 600F SRM 51-72-10-001,PAGE 2,REPAIR CLASSIFIED AS MINOR PER GMM 06-2-100SDR CALA2024120503022Flange · corrodedLAV SERVICE PANEL FLANGE CORRODED AT STA 710 AND S-22L MARKED 13067. REF AMES NR 172653-0100-0207 SRM 57-40-02 PARA H AND 7. SEE PARTIAL WORK ACCOMPLISHED AND PAR BLENDED AND CHECKED LIMITS ON LAV SERVICE PANEL FLANGE FOUND OUT TIAL WORKSHEET # 67 PAGES 1-6 OFSDR AALA202412015370Support Bracket · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN BULKHEAD SUPPORT BRACKET LOCATED AT STA 2268.25 LEFT HAND SIDE. REPLACED SUPPORT BRACKET PER SRM 51-40-02-0G AND DWG 148W3271.SDR AALA202502266193Fitting · burredAIRCRAFT IN BASE MAINTENANCE: BURRED MATERIAL (OVALIZATION) 80 VU RACK LOWER LATERAL FITTING RH SIDE. MEASURE W: 0.335 INCH. MAINTENANCE PERFORMED INTERIM REPAIR LOCATED ON LOWER LATERAL FITTING 80VU RACK AT LEVEL FR 23 TO FR 24, STGR 32 RH SIDE IAW EA 360316 SDR SWIA202401071129Floor Support · corrodedRH CABIN FLOOR SILL AT RBL 41.75 AND BETWEEN FS559.00 +16 TO FS559.00 +48 HAS SURFACE CORROSION ON TOP SURFACE. (FILED CLOSED) REPAIRED THE RH CABIN FLOOR SILL AT RBL 41.75 AND BETWEEN FS559.00 +16 TO FS559.00 +48 IN REFERENCE WITH REO 601R-53-51-696 RSDR SWAA2025010772528Shield · corrodedACB; SHIELD BS 847+8 RBL 23 HAS CORROSION (MARKED).<[01] REMOVED AND REPLACED ACB; SHIELD BS 847 TO BS867 RBL 23 I.A.W SRM 51-40-02-0G-0 AND DWG 146A0081.;[02] VERIFIED ACTION 1.<BR>JOB COMPLETE.SDR VNAA20250102010Plate · corrodedCORROSION ON DRAIN PLATE OF FLOOR PANEL 232BRF. DRAIN PLATE OF FLOOR PANEL 232BRF WAS REPLACED PER CRJ/900 AMM 53-00-47.SDR VNAA20250102009Angle · corrodedCORROSION ON ANGLE MOUNTING AND ANGLES (4EAS) BTW FS310 TO FS319 AT GALLEY SERVICE DOOR SURROUND STRUCTURE. CORROSION ON ANGLES (4EAS) BTW FS310 TO FS319 AT GALLEY SERVICE DOOR SURROUND STRUCTURE WAS REMOVED PER CRJ-900 SRM 51-21-06-001-001-A01 AND EVALUATESDR VNAA20250102008Cap · corrodedCORROSION ON KICKPLATE AND MID CAP BTW FS 310.00 TO FS 349.00 AT SURROUND STRUCTURE PASSENGER DOOR. CORROSION ON KICKPLATE BTW FS 310.00 TO FS 349.00 AT SURROUND STRUCTURE PASSENGER DOOR WAS REMOVED PER CRJ-900 SRM 51-21-06-001-001-A01,EVALUATED ON KICKPLATE,SDR VNAA20250102006Door Sill · corrodedCORROSION ON AFT CARGO COMPARTMENT DOOR SILL BTW FS 1000.00 TO FS 1047.00, BTW STGR 17LH AND STGR 18LH. CORROSION ON AFT CARGO COMPARTMENT DOOR SILL BTW FS 1000.00 TO FS 1047.00, BTW STGR 17LH AND STGR 18LH WAS EVALUATED OUT OF LIMITS PER CRJ900 SRM 53-61-23-SDR SWAA2025010272748Web · corrodedCORROSION WEB - INTERCOSTAL LOCATED BTW BS492.4 TO BS500A WL156 AND RBL21 FWD CARGO COMPARTMENT 2024-728531<[01] REPLACED WEB INTERCOSTAL AND FASTENERS LOCATED BS 492.4 AND BS 500A WL156 AND RBL21 I.A.W B737-800 SRM 51-40-02; DWG: 143A0080; SHEET: 39; REV: - SSDR SWAA2024123172752Angle · crackedCRACK ANGLE - CLIP LOCATED BS400 AND LBL25 AFT POSITION FWD CARGO COMPARTMENT 2024-728547<[01] REPLACED ANGLE-CLIP AND FASTENERS LOCATED ON BS400 AND LBL25 AFT POSITION FWD CARGO COMPARTMENT IAW B737-800 SRM 51-40-02 AND 143A7505 SHEET 108 REV-.SDR SWAA2024123172749Support · corrodedCORROSION SUPPORT ZEE LOCATED BTW BS500D TO BS500F WL156 AND LBL21 AT FWD CARGO COMPARTMENT 2024-728539<[01] STEP 3. ULTRASONIC EQUIPMENT USED P/N: 45MG; S/N: 130063701 AND DUE DATE: 08-OCT-25.;[02] REPLACED SUPPORT ZEE LOCATED BTW BS500D TO BS500F WL156 AND LSDR SWAA2024123172750Support · corrodedCORROSION ON SUPPORT ZEE LOCATED BTW BS500E TO BS500G WL156 AND RBL21 AT FWD CARGO COMPARTMENT 2024-728541<[01] REPLACED SUPPORT ZEE LOCATED BTW BS 500A TO BS 500I WL156 AND RBL21 AT FWD CARGO COMPARTMENT WORKING WAS DOCUMENTED ON NRC TTG8Q00XBYQG SEE<BR>INDIVSDR SWAA2024123172751Support · corrodedCORROSION ON SUPPORT ZEE LOCATED BTW BS500G TO BS500I WL156 AND RBL21 AT FWD CARGO COMPARTMENT 2024-728542<[01] REPLACED SUPPORT ZEE LOCATED BTW BS 500A TO BS 500I WL156 AND RBL21 AT FWD CARGO COMPARTMENT WORKING WAS DOCUMENTED ON NRC TTG8Q00XBYQG SEE INDIVIDUSDR SWAA2024123172757Support · corrodedCORROSION ON SUPPORT ZEE LOCATED BTW BS500C TO BS500E WL156 AND RBL21 AT FWD CARGO COMPARTMENT 2024-728540<[01] REPLACED [1] ZEE CHANNEL SIDEPLATE 2(EA); [2] SPLICE (1EA) SIDEPLATE; NUTPLATE AND FASTENERS IAW B737-800 SRM 53-00-53-2R-6 REPAIR 6 FIGURE 202 AND SDR SWAA2024123172745Support · corrodedCORROSION SUPPORT ZEE LOCATED BTW BS727J TO BS767 WL156 AND RBL21 AFT CARGO COMPARTMENT 2024-728522<[01] REPAIRED AND REPLACED SUPPORT ZEE SECTION; SPLICE REPAIR (1 E/A). SPLICE (1 E/A) AND FASTENERS LOCATED BTW BS727G PLUS 11? TO BS767 WL156 AND RBL21 AFT CARSDR SWAA2024123172744Support · crackedCRACK SUPPORT ZEE LOCATED BS747 AND LBL21 AFT CARGO COMPARTMENT 2024-728520<[01] REPAIRED AND REPLACED SUPPORT ZEE SECTION ; SPLICE SIDEPLATE REPAIR; SPLICE AND FASTENERS LOCATED BETWEEN BS 727J TO BS 847 AND LBL21 AFT CARGO COMPARTMENT IAW B737-800 SRM 53-00-SDR DALA2024121911837Baffle · cracked(LOG 0715223) FWD CARGO LH SIDE BS 500E - 500F BAFFLE CRACKED LBL 23. REMOVED AND REPLACED FWD CARGO L/H SIDE BS 500E - 500F BAFFLE LBL 23 PER B737 SRM 51-40-02-0G.SDR JJBA20241219044Floor Support · crackedCF4, RH OMEGA BEAM FOUND CORRODED BTW FR60-61. REPAIR DOUBLER ON CENTER FUSE IV RH OMEGA BEAM ON UPPER SURFACE BTW FR60-61SDR DALA2024121711781Baffle · cracked(LOG 0713388) FWD CARGO RH SIDE BS 500A - 500B BAFFLE CRACKED RBL 23. REMOVED AND REPLACED FWD CARGO R/H SIDE BS 500A - 500B BAFFLE IAW B737 SRM 51-40-02-0G AND DWG 143A7505.SDR DALA2024121711780Sill Drain · corroded(LOG 0713380) CORROSION ALONG MOP SILL BETWEEN STA 962 / RBL 56 / WL 208 AND STA 986.5 / RBL 48.5 / WL 208. REMOVED AND REPLACED FWD CARGO R/H SIDE BS 500E-500F BAFFLE IAW B737 SRM 51-40-02-0G AND DWG 143A7505.SDR DALA2024121211675Web · corroded(LOG 0705102) CORROSION ON FWD CARGO COMPARTMENT DOOR THRESHOLD WEB. REMOVED AND REPLACED NEW WEB ON FWD CARGO COMPARTMENT DOOR THRESHOLD IAW B-737 SRM 51-40-02-0G AND DWG 143A8122.SDR JJBA20241209015Support · corrodedCF2, LH SILL BTW FR 29-36 FOUND CORRODED. CF2, LH SILL BTW FR 24-36 BLENDED CORROSION AND FOUND OUT OF LIMIT. CF2, LH SILL BTW FR 29-36 REMOVED AND REPLACED.SDR JJBA20241209014Support · corrodedCF2, RH SILL BTW FR 29-36 FOUND CORRODED. RH SILL BTW FR 29-36 BLENDED OUT OF LIMITS. CF2 RH SILL BTW FR 29-36 REMOVED AND REPLACEDSDR AALA202412023894Web · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED AFT CABIN FLOOR WEB BETWEEN FR 68 AND FR 69 AT S23L. REPLACED WEB PER SRM 51-42-11-801.SDR CALA2024120202991Channel · corrodedB757-53-3-0526 STR-Z154 AFT CARGO COMPT STA 1460 BTWN STR 29R/30 HAS SHEAR TIE WITH CORROSION. REMOVED AND REPLACED SHEAR TIE AT AFT CARGO COMPT. STA 1460 BETW AND INSTALLED PARTS FOR ACCESS BY EVALUATION FRAME. EEN STR 29RH TO 30 IAW B757-300 SRM 51-40-02-0G-SDR CALA2024120202989Intercostal · corrodedB757-53-3-0526 STR-Z154 AFT CARGO COMPARTMENT STA1420/1440 BTWN STR 28R/29R HAS INTERCOSTAL WITH CORROSION. REMOVED AND REPLACED INTERCOSTAL AFT CARGO COMPT. STA 1420 TO ST A 1440 AND BETWEEN STR 28RH TO STR 29RH IAW B757-300 SRM 51-40-0 2-0G-0.SDR DALA2024113011279String · corrodedSHIP 3145 CORROSION INTERNAL STRUCTURE ON STRINGER 34L BTW FR 12 TO FR 13 IN LATERAL AVIONIC COMP LH. CORRECTIVE ACTION: REPLACED STRINGER 34L AND FASTENERS PER A319 SRM 51-42-11 AND SRM 51-72-11. (0684580)SDR REXA2025012300077Floor Support · corrodedCORROSION ON BEAM BTW FS 985.00/ FS 1088.00 AND RBL 27 AT AFT CARGO FLOOR STRUCTURE BEAM BTW FS 985.00/FS1056.25 & BTW FS 1070/ FS 1088.00 WAS RE-INSPECTED, NO DAMAGE WAS FOUND PER CRJ700 SRM 51-26-00-001-001-A01 AND BEAM BTW FS1056.25/FS1074.75 WAS REPAIRED PSDR SWIA202501061128Intercostal · not reportedREMOVED INTERCOSTAL RUNNING BETWEEN LBL 36.00 AND LBL 47.00 AT FS 471.00 TO FOM. FOR ITEM ID REFERENCE SRM 53-41-45 FIGURE 1 (SHEET 4) FIGURE J, ITEM 5 ON PAGE 5. (FILED CLOSED) INSTALLED INTERCOSTAL RUNNING BETWEEN LBL 36.00 AND LBL 47.00 AT FS 471.00
Back to JASC 5320