JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2024012936605Plate · corrodedFWD. CARGO; R/H SIDEPLATE HAS CORROSION AT HOLES FROM BS 500G-BS 500H.<[01] THIS SECTION TO BE REPLACED ON TASK CARD TTG8Q00QLSX7;[02] BLENDED AREAS; REMOVED .007' MATERIAL. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2. THIS SECTION TO BE REPLACED ON TASK CSDR SWAA2024012936607Plate · corrodedFWD. CARGO; R/H SIDEPLATE HAS CORROSION AT HOLES FROM BS 500H-BS 500I.<[01] THIS SECTION TO BE REPLACED ON TASK CARD TTG8Q00QLSX7;[02] BLENDED AREAS; REMOVED .007' MATERIAL. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2. THIS SECTION TO BE REPLACED ON TASK CSDR SWAA2024012636594Plate · corrodedFWD. CARGO; L/H SIDEPLATE HAS CORROSION AT HOLES FROM BS 500B+16.<[01] BLENDED AREAS. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2;[02] BLENDED AREAS; REMOVED 0.008' MATERIAL. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2;[03] FABRICATED REPLACEMENT SECTISDR SWAA2024012636601Plate · corrodedFWD. CARGO; L/H SIDEPLATE HAS CORROSION AT HOLES FROM BS 500E-BS 500F.<[01] REMOVE DAMAGE(0.008' MATERIAL) FOUND TO BE OUT OF LIMIT PER SRM 53-00-53-1A-2.<BR>THIS SECTION TO BE REPLACED ON TTG8Q00QLSX2;[02] REMOVE DAMAGE(0.008' MATERIAL) FOUND TO BE OUT OF LIMSDR SWAA2024012636603Plate · corrodedFWD. CARGO; L/H SIDEPLATE HAS CORROSION AT HOLES FROM BS 500F-BS 500G.<[01] REMOVE DAMAGE(0.008' MATERIAL) FOUND TO BE OUT OF LIMIT PER SRM 53-00-53-1A-2.<BR>THIS SECTION TO BE REPLACED ON TTG8Q00QLSX2;[02] REMOVE DAMAGE(0.008' MATERIAL) FOUND TO BE OUT OF LIMSDR SWAA2024012636486Strap · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; MULTIPLE AREAS OF CORROSION ON FLOOR SUPPORT STRAP AT STA767+5<[01] FLOOR SUPPORT STRAP TO BE REPLACED NEW REF SRM 53-00-53;[02] VERIFIED CORRECTIVE ACTION #1SDR SWAA2024012536512Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION AT STA 727C+16<[01] REMOVED CORROSION FROM AFT CARGO LEFT SIDE PLATE FROM STA 727C+16?. ORIGINALS MATERIAL THICKNESS IS 0.040?; MAX MATERIAL LOSS IS 0.007?; MAX ALLOWED IS 0.004?; FOUSDR SWAA2024012536467Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS AREAS OF SURFACE CORROSION FROM STA 727D+3- STA727D+6<[01] REMOVED CORROSION FROM AFT CARGO LEFT SIDE PLATE FROM STA 727D+3 TO STA 727D+6. ORIGINALS MATERIAL THICKNESS IS 0.040?; MAX MATERIAL LOSS IS 0SDR SWAA2024012536468Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS AREAS OF SURFACE CORROSION FROM STA 727J+6 - STA727J+14<[01] REMOVED CORROSION FROM AFT CARGO LEFT SIDE PLATE FROM STA 727J +6 - STA 727J+14. ORIGINAL MATERIAL THICKNESS IS 0.040?; MAX MATERIAL LOSS ISSDR SWAA2024012536516Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS AREAS OF SURFACE CORROSION FROM STA 727I+10- STA727I+18<[01] REMOVED CORROSION FROM AFT CARGO LEFT SIDE PLATE FROM STA 727I +10- STA 727+18. ORIGINAL MATERIAL THICKNESS IS 0.040?; MAX MATERIAL LOSS IS SDR SWAA2024012536470Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS AREAS OF SURFACE CORROSION FROM STA 747+6- STA747+14<[01] REMOVED CORROSION FROM AFT CARGO LEFT SIDE PLATE FROM STA 747 +6 - STA 747+14. ORIGINAL MATERIAL THICKNESS IS 0.040?; MAX MATERIAL LOSS IS 0.00SDR SWAA2024012536471Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS AREAS OF SURFACE CORROSION FROM STA 767+10- STA767+15<[01] REMOVED CORROSION FROM AFT CARGO LEFT SIDE PLATE FROM STA 767 +10- STA767+15. ORIGINALS MATERIAL THICKNESS IS 0.040?; MAX MATERIAL LOSS IS 0.0SDR SWAA2024012536517Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION AT STA807<[01] REMOVED CORROSION FROM AFT CARGO LEFT SIDE PLATE FROM STA 807. ORIGINAL MATERIAL THICKNESS IS 0.040?; MAX MATERIAL LOSS IS 0.008?; MAX ALLOWED IS 0.004?; FOUND TO BE OUSDR SWAA2024012536518Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION AT STA727E+13<[01] REMOVED CORROSION FROM AFT CARGO LEFT SIDE PLATE FROM STA 727E+13. ORIGINAL MATERIAL THICKNESS IS 0.040?; MAX MATERIAL LOSS IS 0.008?; MAX ALLOWED IS 0.004?; FOUND SDR SWAA2024012536475Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION AT STA727E+16<[01] REMOVED CORROSION FROM AFT CARGO LEFT SIDE PLATE FROM STA 727E+16. ORIGINAL MATERIAL THICKNESS IS 0.040?; MAX MATERIAL LOSS IS 0.008?; MAX ALLOWED IS 0.004?; FOUND SDR SWAA2024012536477Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION AT STA727F+9<[01] REMOVED CORROSION FROM AFT CARGO LEFT SIDE PLATE FROM STA 727F +9. ORIGINAL MATERIAL THICKNESS IS 0.040?; MAX MATERIAL LOSS IS 0.008?; MAX ALLOWED IS 0.004?; FOUND TSDR SWAA2024012536520Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION AT STA727G+6<[01] REMOVED CORROSION FROM AFT CARGO LEFT SIDE PLATE FROM STA 727+6. ORIGINAL MATERIAL THICKNESS IS 0.040?; MAX MATERIAL LOSS IS 0.008?; MAX ALLOWED IS 0.004?; FOUND TO SDR SWAA2024012536478Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS SURFACE CORROSION AT STA727+15<[01] REMOVED CORROSION FROM AFT CARGO R/H SIDE PLATE FROM STA 727+15. ORIGINAL MATERIAL THICKNESS IS 0.040?; MAX MATERIAL LOSS IS 0.008?; MAX ALLOWED IS 0.004?; FOUND TOSDR SWAA2024012536523Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS SURFACE CORROSION AT STA727A+12<[01] REMOVED CORROSION FROM AFT CARGO R/H SIDE PLATE FROM STA 727+12. ORIGINAL MATERIAL THICKNESS IS 0.040?; MAX MATERIAL LOSS IS 0.006?; MAX ALLOWED IS 0.004?; FOUND TSDR SWAA2024012536525Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS SURFACE CORROSION AT STA727E+12.5<[01] REMOVED CORROSION FROM AFT CARGO R/H SIDE PLATE FROM STA 727E+12.5. ORIGINAL MATERIAL THICKNESS IS 0.040?; MAX MATERIAL LOSS IS 0.005?; MAX ALLOWED IS 0.004?; FOSDR SWAA2024012536479Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS SURFACE CORROSION AT STA727F<[01] REMOVED CORROSION FROM AFT CARGO R/H SIDE PLATE FROM STA 727F ORIGINAL MATERIAL THICKNESS IS 0.040?; MAX MATERIAL LOSS IS 0.006?; MAX ALLOWED IS 0.004?; FOUND TO BE OSDR SWAA2024012536526Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS SURFACE CORROSION AT STA727G<[01] REMOVED CORROSION FROM AFT CARGO R/H SIDE PLATE FROM STA 727G. ORIGINAL MATERIAL THICKNESS IS 0.040?; MAX MATERIAL LOSS IS 0.008?; MAX ALLOWED IS 0.004?; FOUND TO BE SDR SWAA2024012536480Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS SURFACE CORROSION AT STA727F+9<[01] REMOVED CORROSION FROM AFT CARGO R/H SIDE PLATE FROM STA 727F+9. ORIGINAL MATERIAL THICKNESS IS 0.040?; MAX MATERIAL LOSS IS 0.008?; MAX ALLOWED IS 0.004?; FOUND TOSDR SWAA2024012536527Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS SURFACE CORROSION AT STA727F+19<[01] REMOVED CORROSION FROM AFT CARGO R/H SIDE PLATE FROM STA 727F+19. ORIGINAL MATERIAL THICKNESS IS 0.040?; MAX MATERIAL LOSS IS 0.006?; MAX ALLOWED IS 0.004?; FOUND SDR SWAA2024012536481Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS AREAS OF SURFACE CORROSION FROM STA727H+6 - STA727H+16<[01] REMOVED CORROSION FROM AFT CARGO R/H SIDE PLATE FROM STA 727H+6 TO STA 727H+16. ORIGINAL MATERIAL THICKNESS IS 0.040?; MAX MATERIAL LOSS IS SDR SWAA2024012536482Plate · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS AREAS OF SURFACE CORROSION FROM STA727I+7 - STA727I+16<[01] REMOVED CORROSION FROM AFT CARGO R/H SIDE PLATE FROM STA 727I+7 TO STA 727I+16 ORIGINAL MATERIAL THICKNESS IS 0.040?; MAX MATERIAL LOSS IS 0SDR SWAA2024012436595Plate · corrodedFWD. CARGO; R/H SIDEPLATE HAS CORROSION AT HOLES FROM BS 500C-BS 500D.<[01] BLENDED CORROSION PER SRM 51-10-02. DAMAGE REMOVAL FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2.;[02] REMOVED AND REPLACED R/H TRANSITION ANGLE FROM 727 A TO 727 I PER SRM 51-10-02;SDR IPXA2024010314319Angle · crackedCRACK - ANGLE AFT CARGO COMPARTMENT FWD SIDE AT STA 1087 RBL 18" (REPLACE) OK TO WORK. REMOVED DAMAGE PART I.A.W SRM 51-40-02-0G REV. 88. INSTALLED NEW PART I.A.W SRM 51-40-02-0G REV. 88 AND BOEING DWG NO. 140T0130 SH. 50 REV. A. JOB COMPLETED.SDR IPXA2024010314307Angle · crackedAFT CARGO COMPARTMENT FWD SIDE AT STA 1087 LBL 18" ANGLE (REPLACE) OK TO WORK REMOVED DAMAGE PART I.A.W SRM 51-40-02-0G REV. 88. INSTALLED NEW PART I.A.W SRM 51-40-02-0G REV. 88 AND BOEING DWG NO. 140T0130 SH. 50 REV. A. JOB COMPLETED.SDR DALA2024010210776Unknown · unknownSHIP 6817 CORROSION ON FLOOR STRINGERS BTW STA1440 TO 1460, RBL 2.90, 7.55, AND LBL 2.90, 7.55, 16.10, AT AFT CARGO. CORRECTIVE ACTION: SUMMARY OF NRC 00707: FLOOR STRINGERS BTW STA1440 TO 1500, RBL 2.90, 7.55, AND LBL 2.90, 7.55, 16.10, AT AFT CARGO WERE REPLSDR DALA2024010210775Unknown · unknownSHIP 6817 CORROSION ON FLOOR SUPPORT BTW STA 1320 TO 1340 LBL 16.10 AT AFT CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00204: FLOOR SUPPORT BTW STA 1320 TO 1340 LBL 16.10 WAS REPAIRED PER B757-200 SRM 53-00. (0132036)SDR DALA2024010210753Unknown · unknownTOOL MARK ON CUSP MEMBRANE (INTERNAL SIDE) ON STA Y=916 AND X=-56 AT PAX CABIN. SUMMARY OF NRC 00448: CUSP MEMBRANE (INTERNAL SIDE) ON STA Y=916 AND X=-56 AT PAX CABIN WAS REPAIRED PER B717-200 SRM 53-00-55-2R-4 FIG 208. (LP #0132552)SDR CALA2024010200015Bracket · corrodedCORROSION ALC FS 1540 SHEAR TIE BETW EEN STR 38R & 39R AFT SIDE. BLENDED CORROSION ON SHEAR TIE AT STA 1540 STR 38R-39R MATERIAL LOSS .025" ALLOWABLE DAMAGE .006" FOUND TO BE OUT OF LIMITS REMO VED AND REPLACE SHEAR TIE WITH PN: 140T21-02U585 IAW B767-300 SR SDR JR2R20231230130Gusset · corrodedRH LONG BEAM BETWEEN FR86 AND FR88 RBL11 CORRODED. REPAIREDSDR JR2R20231230128Gusset · corrodedGUSSET (TEXAS DOUBLER) AT FR90 RBL24 CORRODED. REMOVED AND REPLACEDSDR JR2R20231230129Floor Support · corrodedRH FLOOR SILL CORRODED BETWEEN FR88 AND FR90. REMOVED AND REPLACEDSDR BAGA2024021200003Floor Support · corrodedDURING THE LEASE RETURN INSPECTION OF N193BZ, ZONAL INSPECTION CARDS FOUND CORROSION IN THE CENTER FUSELAGE LH INBD FLOOR BEAM BETWEEN FR 84 AND FR 87 AT Y - 10. THE REPAIR WAS SIGNED OFF ON 12/29/23 AS A MAJOR REPAIR. THE AIRCRAFT WAS RETURNED TO SERVICE ONSDR SWAA2024020936173Gusset · crackedFWD CARGO COMPARTMENT STA 500D STR 19R GUSSET CRACK<[01] REMOVED AND REPLACED NEW GUSSET AT FWD CARGO COMPT FROM STA 500D STR 19R PER REF SRM 51-40-02-0G-0;[02] CORRECTION TO STEP 1:REMOVED AND REPLACED NEW GUSSET AT FWD CARGO COMPT FROM STA 500D STR 19R PER RSDR SWAA2024020936166Angle · crackedMAIN CABIN STA 540 RBL 2' FLOOR PANEL BREAK ANGLE CRACK<[01] THIS FAULT WAS RESOLVED ON CARD: TTG8Q00QKQGH.;[02] VERIFIED STEP 1SDR SWAA2024020936167Angle · crackedMAIN CABIN STA 540 LBL 2' FLOOR PANEL BREAK ANGLE CRACK<[01] THE PANEL BREAK WAS REPLACED ON CARD: TTG8Q00QKQZ5.;[02] VERIFIED STEP 1SDR SWAA2024020936170Strap · corrodedORROSION ** AT AFT CARGO COMPARTMENT FLOOR SUPPORT ANGLE LOWER NUTS STRAP AFT OF STA 787 S-25R MKD DOT<[01] REMOVED AND REPLACED STRAP AT AFT CARGO COMPARTMENT FLOOR SUPPORT ANGLE LOWER AREA AFT OF STA 787 S-25R PER REF SRM 51-40-02-0G-0AND DWG#146A0081.;[02] SDR SWAA2024020936171Channel · corrodedORROSION ** AT AFT CARGO COMPARTMENT FLOOR Z CHANNEL INTERCOSTAL SUPPORT UNDER AROUND NUT PLATES S-25R STA 767+6' MKD DOT<[01] REMOVED CORROSION AT AFT CARGO COMPARTMENT FLOOR Z CHANNEL INTERCOSTAL SUPPORT S-25R STA 767 PER SRM 51-10-02-0-0.EVALUATED REWORKED SDR IPXA2024011201605Filler · crackedFAULT - CRACK - FLOOR STRUCTURE BULK CARGO COMPARTMENT RIGHT AREA STA 1600 RBL 60(REPLACE) I.A.W AMM 25-59-01-404-019 REV.140 INSTALL SLOPING SIDEWALL , SIDEWALL AND BULKHEAD.SDR IPXA2024011201574Filler · crackedCRACK - FLOOR STRUCTURE BULK CARGO COMPARTMENT LEFT AERA STA 1590 LBL60(REPLACE) I.A.W AMM 25-59-01-404-019 REV.140 INSTALL SLOPING SIDEWALL , SIDEWALL AND BULKHEAD.SDR AALA202401194631Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CARGO COMPARTMENT TRANSITION PANEL FROM STA 727 TO STA 787, LBL 25. REPLACED TRANSITION PANEL PER AARD 51-00-05-01.SDR AALA202401191777Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CARGO COMPARTMENT TRANSITION PANEL FROM BS 727D TO BS 767, RBL 30. REPLACED TRANSITION PANEL PER AARD 51-00-05-01.SDR 2024FA0000041Bracket · crackedFLAP HANDLE FORWARD SUPPORT BRACKET FOUND CRACKED. NOTED AREA OF STRESS/CRACK A LACK OF
RADIUS. REPLACED WITH FACTORY NEW BRACKET.SDR IPXA2024010301605Unknown · unknown*SDR FILED OPEN* FAULT - CORROSION - FLOOR STRUCTURE BULK CARGO COMPARTMENT RIGHT AREA STA 1600 RBL 60(REPLACE) 1. REMOVED DAMAGE PARTS I.A.W SRM 51-40-02-0G REV. 88<BR>2. INSTALLED NEW PARTS I.A.W SRM 51-40-02-0G REV. 88 AND BOEING DWG NO:146T5650 SHEET 5 REVSDR IPXA2024010301574Unknown · unknown*SDR FILED OPEN* FAULT- CORROSION - FLOOR STRUCTURE BULK CARGO COMPARTMENT LEFT AERA STA 1590 LBL60(REPLACE) 1. REMOVED DAMAGE PARTS I.A.W SRM 51-40-02-0G REV. 88<BR>2. INSTALLED NEW PARTS I.A.W SRM 51-40-02-0G REV. 88 AND BOEING DWG NO:146T5650 SHEET 5 REV.CSDR DALA2024010200039Unknown · unknownSHIP 3120 CRACK AFT LOAD TRANSMITTING PROFIL LOC INTERNAL AREA EMERGENCY EXIT DOOR 844 PASSENGER CABIN. CORRECTIVE ACTION: REPAIRED PER ER/A 613632-14AD. (0131598)
Back to JASC 5320