JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2021081991437Angle · corrodedAFT CARGO COMPARTMENT; LH Z-ANGLE HAS CORROSION AT STA 727E+18'; LBL 21; WL 156; DOT#A-193-32 ; / [01] FABRICATED REPLACEMENT ZEE ANGLE BS 727-847 IAW SRM 53-00-52-2R-5 ON FAULT TTG8Q005PPNQ; [02] ALL WORK C/W<BR>AUDIT C/WSDR SWAA2021081991442Angle · corrodedAFT CARGO COMPARTMENT; LH Z-ANGLE HAS CORROSION AT STA 747+9'; LBL 21; WL 156; DOT#A-193-44 ; / [01] FABRICATED REPLACEMENT ZEE ANGLE BS 727-847 IAW SRM 53-00-52-2R-5 ON FAULT TTG8Q005PPNQ; [02] ALL WORK C/W<BR>AUDIT C/WSDR SWAA2021081991907Shield · corrodedA045-003; FORWARD PIT; RH SIDE SHIELD HAS CORROSION. BS:480+15 TO 500+11; RBL:25; WL:155. ; / [01] EVALUATED MATERIAL LOSS AND FOUND AREA TO HAVE 100% MATERIAL LOSS IAW SRM 53-00-53-1A-2; [02] RECIEVED AND VERIFIED NEW SHIELD P/N 143A8126U31ATSMRO ATAG BF3641 SDR SWAA2021081291716Floor Support · deterioratedDETERIORATED FLOOR STRUCTURE CIC STA 270 TO STA 380 AT FWD GALLEY AREA ; 2021-311651 / [01] OK TO APPLY CIC FLOOR STRUCTURE AREA ON STA 270 AT STA 380.; [02] APPLIED ON FLOOR STRUCTURE CIC STA 270 TO 380 AT FWD GALLEY AREA I.A.W. B737-700 AMM 51-21-91-620-802.SDR SWAA2021081291709Gusset · crackedCRACK GUSSET LOCATED BS500D AT LEVEL STR19R FWD CARGO COMPARTMENT (1 EA) ; 2021-311646 / [01] OK TO INSTALL GUSSET; [02] DRILLED NEW GUSSET AND APPLIED PROTECTIVE TREATMENT ON OPEN HOLE LOCATED BS 500D AT LEVEL STR 19R IAW B737-700 SRM 51-40-02 AND SRM 51-20-0SDR SWAA2021081291710Gusset · crackedCRACK GUSSET LOCATED BS500D AT LEVEL STR19L FWD CARGO COMPARTMENT (1 EA) ; 2021-311645 / [01] OK TO INSTAL GUSSET.; [02] DRILLED NEW GUSSET AND APPLIED PROTECTIVE TREATMENT ON HOLES LOCATED ON BS 500D AND S-19L IAW B737-700 SRM 51-40-02;51-20-01. OK TO INSTALLSDR SWAA2021081191718Support Angle · crackedCRACK ANGLE - SUPPORT LOCATED BTW BSTA 907 TO BSTA 927 AND STR 25R TO STR 27R AT AFT CARGO COMPARTMENT ; 2021-311659 / [01] TOOL USED:SOLAR POWER CALIPER P/N:500-464;S/N:11572544;DUE DATE:15/JAN/22; [02] REPLACED ANGLE - SUPPORT LOCATED BTW BSTA 907 TO BSTA 92SDR SWAA2021081191813Bracket · crackedCRACK NOTED IN BOTTOM LAYER OF HOLE AT RBL 45.5 SEAT TRACK AT BS-727B. ; / [01] REMOVED FASTNERS IN H BRACKET BS 727B RBL 45.5 PER SRM 51-40-02-OG-0; [02] ET INSPECTED HOLE IAW 737 NDTM PART 6 51-00-00 PROCEDURE 16; NO CRACKS NOTED.<BR><BR>CAL ID ATS1645 N600;SDR FDEA202107061942Support · corrodedMAIN CABIN AFT LAV SUPPORT AGA7544-1 STATION 1891-2007 LBL 24 EXFOLIATION CORROSION EXISTS ON FOWARD END BEYOND LIMITS INSTALLED NEW/FABRICATED AFT LAV SUPPORT ON MAIN CABIN AT STATION 1891-2007 LBL 24 REF, DOUGLAS DWG NO. AGA7087 AND MD10-30 SRM 51-31-01 SDR SWAA2021080491820Support Angle · crackedCRACK ANGLE - SUPPORT LOCATED ON BS807 AND RBL 19 APPROX. AFT CARGO COMPARTMENT ; 2021-319750 / [01] REPLACED ANGLE-SUPPORT LOCATED ON BS807 AND RBL19 AFT CARGO COMPARTMENT IAW B737-700 SRM 51-40-02 ;51-10-02 AND DWG # 146A8120 REV A ;146A0081 REV C; [02] REPLSDR SWAA2021073091643Scuff Plate · crackedFWD CARGO DOOR CUTOUT AFT CORNER SCUFF PLATE CRACKED ; / [01] RECIEVED REPAIRD SCUFF PLATE FROM BACKSHOP ON WORKORDER 42436-1400-0001; [02] VERIFIED STEP 1. AUDIT COMPLETESDR ASAA2021070635481Door Sill · corrodedL/H FWD ENTRY DOOR CUT OUT AFT LOWER CORNER CORRODED AT FASTENER HOLE DOT:P776 GROUNDED - YES. ACCOMPLISHED REPAIR ON FWD ENTRY DOOR LOWER SILL IAW AIRBUS A320 SRM 53-11-14. THIS IS A CATEGORY "B" REPAIR WITH AN INSPECTION THRESHOLD OF 60,000 FC REF A32SDR ASAA2021070635480Door Sill · corrodedR/H FWD SERVICE DOOR CUT OUT LOWER AFT CORNER HAS CORRODED AT FASTENER HOLE DOT P772 GROUNDED - YES. ACCOMPLISHED REPAIR AS PER A320 SRM 53-11-14, R/H FWD LOWER DOOR SEAL. THIS IS A CATEGORY "B" REPAIR WITH AN INSPECTION THRESHOLD OF 60,000 FC REF A320 SRM 5SDR ASAA2021070635435Transition Panel · corrodedAFT CARGO PIT R/H TRANS PNL STA 727C TO 767 UPPER AND LOWER CORRODED. GROUNDED - YES. REMOVED CORROSION AREA FOUND TO BE OUT OF LIMITS IAW B737-900ER SRM 53-00-53-1A-2, REPAIRED IAW B737-900ER SRM 53-00-53-2R-5. W=.5 O=.040 R=.026 L=1.5 D=.014SDR ASAA2021070635434Transition Panel · corrodedAFT CARGO PIT L/H TRANS PNL STA 727C TO STA 847 UPPER AND LOWER CORRODED. GROUNDED - YES. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW B737-900 ER SRM 53-00-53-1A-2 FIG 103, FABRICATED REPAIR PARTS IAW B737-900ER SRN 53-00-53-2R-5 PARA 4L AND INSTALLED REPASDR ASAA2021070635395Angle · corrodedAFT CARGO DOOR SURROUND STRUCTURE STA 747-767 STR 25-R FWD SHIELD SUPPORT ANGLE CORRODED. GROUNDED - YES. REMOVED CORROSION AREA FOUND TO BE OUT OF LIMITS IAW B737-900ER SRM 53-60-15-1A-1 REMOVED AND REPLACED SHIELD SUPPORT ANGLE IAW B737-900ER SRM 51-40-02-0GSDR ASAA2021070635443Shield · corrodedAFT CARGO DOOR SURROUND STRUCTURE FWD SHIELD UPPER AND LOWER SURFACES CORRODED. GROUNDED - YES. REMOVED CORROSION AND CHECKED LIMITS FOUND TO BE OUT OF LIMITS IAW B737-900ER SRM 535-60-15-1A-1 DETAIL D. REMOVED AND REPLACED SHIELD IAW B737-900ER SRM 51-40-02-0SDR REXA2021072200516Stringer · corrodedSTGR 25R HAS CORROSION AROUND FASTENERS BETWEEN FS 333.00 AND FS 349.00. RECEIVED & C/W ENDEAVOR AIR EA# CRJ953-11793 REV.IR DATED 6/23/2021 ON STR 25R BETWEEN FS 333.00 AND FS 349.00 CORROSION.SDR REXA2021072100505Frame · corrodedFS 319 FRAME IS CORRODED AT STGR 26L-26R. CW CRJ-900 SRM 53-00-06-201-006-A01 REPAIR OF FS 319 FRAME AT STR 26L-26R. FS 319 FRAME FOUND TO BE OUT OF LIMITS IAW CRJ-900 SRM 53-00-06-201-005-A01.SDR REXA2021072100502Stringer · corrodedSTGR 26R IS CORRODED IN A COUPLE SPOTS BETWEEN FS 280.00 AND FS 310.00. BLENDED & FOUND TO BE OUT OF LIMITS IAW CRJ 900 SRM 53-21-03-101-002- A01. LOCATED & DRILLED NEW SERVICEABLE SDR26R & INSTALLED SERVICEABLE STR26R IAW CRJ 900 SRM 51-40-11-001-001-A01, 51SDR ASAA2021070635436Floor Support · corrodedAFT WET AREA INTERCOSTAL STA 907-927 RBL 45 CORRODED. GROUNDED - YES. REMOVED CORROSION AND CHECKED LIMITS. FOUND TO BE OUT OF LIMITS IAW B737-900ER SRM 53-70-51-1A-1. REMOVED AND REPLACED INTERCOSTAL IAW B737-900ER SRM 51-40-02-0G-0. W=1.0 O=.177 R=.114 L=1.0SDR ASAA2021070635225Web · gougedDAMAGED WEB R/H SIDE OF E&E DOOR SURROUND STRUCTURE GROUNDED - YES. REPLACED WEB SECTIONSDR FDEA202107061691Floor Support · corrodedAFT LOWER CARGO FLOOR PANEL #183KF SUPPORT FOUND CORROSION AT STATION 1841, X = 47" AFT LOWER CARGO FLOOR PANEL #183KF CORRODED SUPPORT AT STATION 1841 X=47" REMOVED AND REPLACED WITH REWORKED SUPPORT AS PER SRM 51-31-01 VOLUME 2. SUPPORT REWORKED AS PSDR FDEA202107061690Web · crackedAFT LOWER CARGO COMPARTMENT FLOOR WEB FOUND CRACKED AT STATION 1841 X = 5". WEB REMOVED AND REPLACED AS PER SRM 51-31-01 VOLUME 2. WEB FABRICATED AS PER DOUGLAS DRAWING AGA 7170 REVISION: T. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.SDR SWAA2021081991420Shield · corrodedA45-001; FORWARD CARGO COMPARTMENT; RIGHT HAND SIDE SHIELD HAS CORROSION; BS:420+9 TO 420+13; RBL:25; WL: 155. ; / [01] REMOVED CORROSION IAW SRM 51-10-02-0G-0 SECTION 15; VERIFIED WITH 10X MAGNIFICATION. VERIFIED LIMITS ORIGINAL THICKNESS .032' LOSS .007' REMSDR SWAA2021081991419Web · corrodedAFT CARGO DOOR CUT OUT BOTTOM WEB CORRODED STA 797 WL 156 RBL20' ; / [01] REMOVED CORROSION FROM LOWER SILL WEB ORIGINAL T= .045' LOSS OF .011' REMAINING T= .034' FOUND TO BE OUT OF LIMITS IAW SRM 53-60-15-1A-1 FIG 103 DETAIL D TOOLING # 21461 CAL DUE 04AUG21;SDR SWIA2021081860356Stiffener · corrodedLOWER FS250.00 STIFFENER CORRODED AT MULTIPLE AREAS (MARKED) BETWEEN STGR 23R TO STGR 23L. (C-CHECK RO 8/16/2021) LOWER FS250.00 STIFFENER CORROSION EVALUATED AS OUT-O-LIMITS WITH 100% MATERIAL LOSS. REMOVED STIFFENER AT FS250.00 BETWEEN STGR23R - STGR2SDR ASAA2021070535546Floor Support · corrodedFLOOR BEAM HAS AREA OF CORROSION ON TOP SURFACE JUST AFT OF R2 DOORDOT:A440 GROUNDED - YES. CORROSION FOUND TO BE OUT OF LIMITS. ORIGINAL THICKNESS IS .160, REMOVED .160, .000 REMAINING REF A320 SRM 53-00-14.REMOVED AND REPLACED BEAM REF A320 SRM D53472458SDR ASAA2021070535415Floor Support · corrodedFLOOR BEAM HAS AREA OF CORROSION ON TOP SURFACE, JUST AFT OF R2 DOOR AND TOWARDS CENTER OF A/C TWO FRAMES GROUNDED - YES. REMOVED AND REPLACED FLOOR BEAM P/N D5347219520400 PO# 1004824.2 IAW AIRBUS A320 SRM 51-42-11 AND AIRBUS DWG # D53472040 ISSUE A.REMOVED SDR DALA2021070703782Strap · crackedSHIP 652 CRACKED STABILIZER STRAP STA. 365 AND RBL 24.75 AT ABOVE NLG W/W. CORRECTIVE ACTION: SUMMARY OF NRC 00746: STABILIZER STRAP STA. 365 AND RBL 24.75 AT WAS REPAIRED PER ER/A 384483-14MA REV. D. (1864494)SDR DALA2021070703779Strap · corrodedSHIP 651 CORROSION ON LH SIDE PANEL STRAP ON STA 1530 AT AFT CARGO COMPARTMENT. (IN REF. NRC 00354)(C2). CORRECTIVE ACTION: SUMMARY OF NRC 00750-SPLICE OF SIDE PANEL WAS REPLACED PER. B757-200 S.R.M. (1864655)SDR DALA2021070703778Floor Support · corrodedSHIP 651 CORROSION ON STRINGER FLOOR SUPPORT RBL 10.45 FROM STA 1206 TO 1217, STA 1235 TO 1254 AND STA 1290 AT AFT CARGO COMPARTMENT. (IN REF. NRC 00350) CORRECTIVE ACTION: SUMMARY ON NRC#00859, THICKNESS MEASUREMENT WAS ACCOMPLISHED ON STRINGER FLOOR SUPPORT SDR DALA2021070703777Floor Support · corrodedSHIP 651 CORROSION ON STRINGER FLOOR SUPPORT LBL 2.90 STA 1353, AT AFT CARGO COMPARTMENT, IN REF WITH NRC 0345. CORRECTIVE ACTION: SUMMARY OF NRC: 00383. STRINGER FLOOR SUPPORT LBL 2.90 STA 1353, AT AFT CARGO COMPARTMENT WAS REPAIRED PER. B-757-200 SRM. (18639SDR DALA2021070703776Floor Support · corrodedSHIP 651 CORROSION ON STRINGER FLOOR SUPPORT RBL 7.55 FROM STA 1380 TO 1410 AT AFT CARGO COMPARTMENT.(IN REF. NRC 00348). CORRECTIVE ACTION: SUMMARY OF NRC: 00848. STRINGER FLOOR SUPPORT RBL 7.55 FROM STA 1380 TO 1410 AT AFT CARGO COMPARTMENT WAS REPLACED PER.SDR SWAA2021081291047Support Angle · crackedCRACK SUPPORT ANGLE LOCATED BTW BS 685 TO BS 706 AND LBL 24.82 AT PASSENGER CABIN ; 2021-311604 / [01] TOOL USED: PRECISION RADIUS P/N:2204A3;S/N:AE-408655;DUE DATE:24/NOV/21.; [02] TOOLS USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811020; DUE DASDR SWAA2021081291048Support Angle · crackedCRACK SUPPORT ANGLE LOCATED BS 685 TO BS 706 AND RBL 24.82 AT PASSENGER CABIN ; 2021-311606 / [01] TOOL USED: PRECISION RADIUS P/N:2204A3;S/N:AE-408655;DUE DATE:24/NOV/21.; [02] TOOLS USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811020; DUE DATE: SDR SWAA2021081291049Support Angle · crackedCRACK SUPPORT ANGLE LOCATED BTW BS 685 TO BS 706 AND LBL 0.07 AT PASSENGER CABIN ; 2021-311607 / [01] REPLACED SUPPORT ANGLE LOC BS 685 AT BS 706 LBL 0.07 AT PASSENGER CABIN IAW B737-700 SRM 51-40-02; 51-10-02 AND DRAWING 273A9110 REV -; [02] CERTIFIED RII WORSDR SWAA2021081291050Stiffener · brokenBROKEN FLOOR STRUCTURE STIFFENER ASSY LOCATED AT BS 540 AND BTW LBL 0 TO LBL 45.57 AT PASSENGER CABIN (2 EA) ; 2021-311602 / [01] INSTALLED STIFFENER ASSY 2 E/A LOCATED AT BS 540 AND BTW LBL 0 TO LBL 45.57 AT PASSENGER CABIN I.A.W B737-700 SRM 51-40-02 AND 51-SDR DALA2021070603730Floor Support · corrodedSHIP 652 CORROSION ON ANGLE FLOOR SUPPORT BTW STA 907 TO 909, LBL 65 AT WING BOX AREA. CORRECTIVE ACTION: SUMMARY OF NRC 01036: ANGLE FLOOR SUPPORT BTW STA 907 TO 909, LBL 65 AT WING BOX AREA WAS REPAIRED PER B757-200 SRM. INSPECTION WAS ACCOMPLISHED AFTER TRISDR DALA2021070603729Floor Support · corrodedSHIP 652 CORROSION ON ANGLE FLOOR SUPPORT RBL 65, BTW STA 1020 TO STA 1021, STA 1027 AND STA 1031 AT WING BOX AREA. CORRECTIVE ACTION: SUMMARY OF NRC 01037: ANGLE FLOOR SUPPORT RBL 65, BTW STA 1020 TO STA 1021, STA 1027 AND STA 1031 AT WING BOX AREA WAS REPAIRSDR REXA2021072100510Stringer Splice · corrodedSTRINGER SPLICE AT FS 333 AND STR 26R IS CORRODED. REMOVED CORROSION FROM STRINGER SPLICE FOUND TO BE OUT OF LIMITS IAW SRM 53-00-00-101-001-A01 REMOVED & REPLACED STRINGER SPLICE AT FS 333.00 & STR 26R IAW CRJ 900 SRM 51-40-11-001-001-A01, 51-42-06-001-001-A0SDR REXA2021072100509Diaphragm · corrodedDIAPHRAGM AT STR 26R BETWEEN FS 349 AND FS 364 IS CORRODED. REMOVED CORROSION FROM DIAPHRAGM AND FOUND OUT OF LIMITS IAW SRM 53-21-23-101-003-A02. REMOVED & REPLACED DIAPHRAGM AT STR 26R BETWEEN FS 349 & FS 364 IAW SRM 51-40-11-001-001-A01, 51-42-06-001-001-ASDR REXA2021072100506Angle · corrodedSERVICE DOOR UPPER SILL ANGLE IS CORRODED. REMOVED & REPLACED SERVICE DOOR UPPER SILL ANGLE. IAW CRJ900 AMM 53-21-27-000/400-802-A02. REINSTALLED SERVICE DOOR STOP FITTINGS, IAW
CRJ900 SRM 51-40-11-001-001-A01.SDR IPXA2021071871799Floor Panel · damagedINSPECTION TYPE:SEGPANEL #242BN HAS COMPOSITE DAMAGECOMPLIED WITH SREO A300-5320-42722-FSDR SWAA2021070790908Panel · crackedFORWARD CARGO PANEL 120ZAC HAS A 6' LONG CRACK 25' FROM LEFT EDGE. PERFORMED INTERIM REPAIR ON PANEL 120ZAC PER EA 1-A25-3722 REV 5 EVERY 8 DAYS PERFORM A DETAILED VISUAL INSPECTION OF THE REPAIRED AREA FOR ADDITIONAL DAMAGE ADN REPAIR INTEGRITY. IF FURTHER DESDR AALA202107062218Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION MEASURING L= 0.381 INCHES, W= 0.366 INCHES, D= 0.036 INCHES ON AFT GALLEY AREA FLOOR BEAM LOCATED BETWEEN FR 64 AND FR 66 AT -Y1292. REPLACED FLOOR BEAM PER SRM 51-72-11-911-001, SRM 51-42-11-801 AND DWG D53472816.SDR DALA2021070603727Floor Support · corrodedSHIP 651 CORROSION ON STRINGER FLOOR SUPPORT LBL 7.55 STA 1323, AT AFT CARGO COMPARTMENT. CORREDTIVE ACTION: SUMMARY OF N.R.C: 00854. STRINGER FLOOR SUPPORT LBL 7.55 STA 1323, AT AFT CARGO COMPARTMENT WERE REPAIRED. PER B757/200 S.R.M.(1862327)SDR DALA2021070603726Floor Support · corrodedSHIP 651 CORROSION ON FLOOR STRINGERS LBL 10.45 AND 16.10 BTW STA 1460 TO 1480 AT AFT CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF N.R.C: 00371. FLOOR STRINGERS LBL 10.45 AND 16.10 BTW STA 1460 TO 1480 AT AFT CARGO COMPARTMENT WERE REPAIRED. PER B757/200 SSDR DALA2021070603724Door Sill · corrodedSHIP 651 CORROSION ON LWR SILL OF THE AFT CARGO DOOR (UNDER TRACK FITTING) STA. 1420, RBL 20. CORRECTIVE ACTION: SUMMARY OF NRC:00301. LWR SILL OF THE AFT CARGO DOOR (UNDER TRACK FITTING) STA. 1420, RBL 20.WAS REPAIR PER B757-200 SRM. (1861814)SDR CALA2021070501021Door Sill · corrodedCORROSION ON R2 SOOR SILL FWD INBD CORNER. PER HAECO LCQ NR 9292 459/32459 GENERATED BY V892443
Back to JASC 5320