SDR SWIA202157479Fitting · damagedDISCREANCY TRANSFERED FROM PARENT CAMP 22281732, PN: 601R35289-1 REQUIRES REPLACEMENT AT LBL 27 BETWEEN F.S 605.0 - 621.0. (C-CHECK RO 4/12/2021) REMOVED AND REPLACED FITTING P/N 601R35289-1 AT LBL 27 BETWEEN FS 605.0 TO FS 621.00 IAW CRJ 200 SRM 51-42-SDR SWAA2021031755539Seat Track · worn#1 SEAT TRACK CROWN LUGS UPPER SURFACE ARE WORN FROM PASSENGER SEAT AT STA 520. / INSTALLED NEW #1 SEAT TRACK SECTION STA 500C+10-STA 520 PER SRM 51-40-02.SDR SWAA2021031755525Seat Track · corrodedCABIN SEAT TRACK #4 HAS LIGHT CORROSION AT STA 649 / REMOVED DAMAGE PER SRM 51-10-02. FOUND TO BE OUT OF LIMITS PER SRM 53-00-52-1A1. P/N 144A5350-3 AT STA 649 0.050 MATERIAL REMOVED. REMOVED AND REPLACE #4 SEAT TRACK FROM STA 538 TO STA 727B PER SOPM 20-50-01SDR SWAA2021031550869Floor Panel · damagedPASSENGER CABIN FLOOR BOARD 242NF HAS DAMAGE ON THE UNDER SIDE INBOARD EDGE AFT OF THE 5TH INSERT. / DUE TO THE EXTENT OF DAMAGE; FABRICATED NEW PASSENGER CABIN FLOOR BOARD 242NF USING BMS 4-17 TY6 LOT# 1420733-1; INSTALLED INSERTS USING BMS 5-107 LOT# AK0HP57SDR SWAA2021031149992Spacer · crackedCRACK AFT BULKHEAD SPACER LOC ON BS 500D AT LEVEL STR 26L AT FWD CARGO COMPARTMENT / REPLACED BULKHEAD SPACER LOC ON BS 500D AT LEVEL STR 26L AT FWD CARGO COMPARTMENT IAW B737-700 SRM 51-40-02 (1EA)SDR AALA202103059023Support Frame · corrodedAIRCRAFT IN BASE MAINTENANCE: AFT CABIN SUPPORT FRAME CORRODED, AT S23R BETWEEN FR69 AND FR70. REPLACED SUPPORT FRAME PER SRM 51-72-11-911-001 AND DWG# D53474180.SDR IPXA2021021765780Support · corrodedINSPECTION TYPE:A300CEILING LINER SUPPORTS 3 EA ATTACHED TO THE LOWER AFT SECTION OF FLOOR BEAM 54.2 CORRODED IN SEVERAL PLACES2 EA CEILING LINER SUPPORTS CORRODED OUT OF LIMITS REMOVED FABRICATED NEW SUPPORTS AND REPLACED IAW SRM ONE EACH FOUND TO BE IN LIMITSDR IPXA2021030266322Fitting · crackedINSPECTION TYPE:C3BLADDER TANK RH SIDE FITTING CRACK AT STA. Y 1278.REMOVED,FABRICATED AND REPLACED CRACKED FITTING IAW SRM 51-33-01 AND 51-31-01 (MINOR).SDR IPXA2021030166222Splice · crackedINSPECTION TYPE:C3MAIN CABIN SPLICE(WEB SUPPORT) CRACK AT STA.1841 LON 19R.REMOVED,FABRICATED AND REPLACED CRACKED SPLICE IAW SRM 51-35-01 AND DWG AFA7798 (MINOR).SDR IPXA2021030166219Support · crackedINSPECTION TYPE:C3MAIN CABIN WEB SUPPORT CRACK AT STA.1841 LON 19L.REMOVED,FABRICATED AND REPLACED CRACKED WEB SUPPORT IAW SRM 51-36-01 AND 51-35-01 (MINOR).SDR DALA2021021600843Intercostal · corrodedDURING INSPECTION MAINTENANCE FOUND CORROSION LEVE 2 ON INTERCOSTAL BTW STA 1400/1420 AND STR 30/29RH AT AFT CARGO COMPARTMENT. INTERCOSTAL REPLACED PER SRM. (LP 1728779)SDR FDEA202102120343Support Angle · crackedAS SEEN FROM BULK PIT AREA, SEAT TRACK SUPPORT ANGLE @ STA 1576, INSIDE R/H SIDEWALL AREA IS CRACKED REMOVED AND REPLACED SEAT TRACK SUPPORT ANGLE PER BAC DWG146T5650 REV C.SDR SWIA202157485Floor Mat · corrodedSTUB RAIL PN: 601R35289-4 AT RBL 27.0 FROM F.S. 605.0 TO F.S. 621.0 REQUIRES REPLACEMENT DUE TO CORROSION OUT OF LIMITS, REF: PARENT CAMP: 22280534. (C-CHECK RO 4/12/2021) INSTALLED NEW STUB RAIL FITTING PN: 601R35289-4 AT RBL 27 FROM F.S 605 TO F.S 621SDR SWIA202156587Bracket · corrodedPAX DOOR SILL FWD BRACKETS AND CHANNEL HAS CORROSION AROUND NUTPLATES AS MARKED. (C-CHECK) RO 3/2/2021 REPLACED PAX DOOR SILL FWD CORRODED BRACKET WITH NEW BRACKET P/N 601R31527-217 REF CRJ200 SRM 51-42-06. SEE CONTINUE CARD FOR FURTHER DETAILS.SDR SWIA202156582Strap · corrodedFS559 STRAPS OUTBOARD LBL 27 HAS CORROSION (C-CHECK) RO 3/2/2021 REMOVED AND INSTALLED NEW STRAP AT FS559 OUTBOARD OF LBL 27 P/N 601R31025-29 CRJ200 SRM 51-42-06 & CRJ 200 SRM 51-42-06 AND DWG 601R31025 REV N. COMPLIED WITH TASK CARD 51-900-1003-SKY SEE CSDR SWIA202156580Door Sill · corrodedSERVICE DOOR SILL HAS CORROSION AROUND LOWER STOP FITTINGS. (C-CHECK) RO 3/2/2021 REMOVED AND RE-INSTALLED 2EA LOWER STOP FITTINGS AT SERVICE DOOR SILL. REPLACED SERVICE DOOR LOWER SILL REF CRJ200 SRM 51-42-06 AND DWG 601R38303 REV AN. COMPLIED WITH TASK CSDR DALA2021021600841Intercostal · corrodedDURING INSPECTION MAITNENANCE FOUND CORROSION LEVEL 2 ON INTERCOSTAL BTW STA 1420/1440 STR 29/28 RH AT AFT CARGO COMPARTMENT. INTERCOSTAL REPAIRED PER SRM 51-70-11. (LP 1728144)SDR DALA2021021600840Deck Plate · corrodedDURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON DECK PLATE STA 1680 BTW LBL 0 TO LBL 21.5 PAX CABIN FLOOR STRUCTURE. FLOOR REPAIRD PER SRM. (LP 1728023)SDR SWAA2021021548424Plate · crackedAFT CARGO COMPARTMENT SILL AFT CORNER PLATE CRACKED. (REF SA-M 326 # A1102331 FROM NRC D406118).PERFORMED W.O. INSTRUCTION# 21-153-00322 TIME LIMITED SCUFF PLATE CRACK REPAIR SPEED TAPE APPLIED- REQUIRES RE INSPECTION EVERY 8 DAYS MUST BE PERMANENTLY REPAIRED SDR DALA2021021200819Web · corrodedSHIP 3240 CORROSION FLOOR STRUCTURE WEB AT FR56 TO FR57 AND STR38L IN AFT CARGO COMPARTMENT. CORRECTIVE ACTION: REPLACED FLOOR STRUCTURE WEB PER A320 SRM 51-42-11 AND 51-72-11. (1728112)SDR DALA2021021200818Web · corrodedSHIP 3240 CORROSION WEB LOCATED FROM FR20 TO FR21 AT LEVEL -Y1732 AT FWD GALLEY AREA. CORRECTIVE ACTION: REPLACED WEB PER A320 SRM 51-72-11. (1728087)SDR CALA2021021200168Intercostal · crackedR1 DOOR FRAME 16 STOP #7 INBOARD UPPER AND LOWER HOLES ARE CRACK ED IN THE INTERCOSTAL FITTING AT 4:00. REPAIR BEFORE NEXT FLIGHT CONTACT ENGINEERING FOR REPAIR INSTRUCTIONS PER NR 9296144 HAEC O NR 38144 GEN BY V061633SDR CALA2021021200167Intercostal · crackedL1 DOOR FRAME 16 STOP #1 INBOARD LOWER HOLE IS CFRACKED IN THE W EB AND IN THE INTERCOSTAL FITTING AT 6:00. REPAIR BEFORE NEXT FL IGHT CONTACT ENGINEERING FOR REPAIR INSTRUCTIONS PER NR 9296143 HAECO OPS 38143 AD 2019-20-10 GEN BY V061633 RMVD AND RPLD INTERCOSDR DALA2021021100798Floor Support · corrodedDURING INITIAL INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON FLOOR SUPPORT STA 1661-1681 LBL 55 AT PAXCABIN FLOOR STRUCTURE . FLOOR SUPPORT REPLACED. (LP 1727722)SDR SWIA202157548Strap · corrodedFLOOR SUPPORT STRAP AT F.S. 559.00 BETWEEN RBL27 AND RBL45 HAS MULTIPLE SPOTS OF CORROSION. (C-CHECK RO 4/12/2021) REMOVED AND REPLACED FLOOR SUPPORT STRAP AT FS559 BETWEEN RBL27 AND RBL45 WITH SERVICEABLE UNIT IAW CRJ-200 SRM 51-42-06.SDR SWIA202157547Strap · corrodedFLOOR SUPPORT STRAP AT F.S. 559.00 BETWEEN LBL27 AND LBL45 HAS MULTIPLE SPOTS OF CORROSION, (C-CHECK RO 4/12/2021) REMOVED AND REPLACED THE L/H FLOOR SUPPORT STRAP AT FS559 BETWEEN LBL27 AND LBL45 WITH SERVICEABLE UNIT IAW CRJ-200 SRM 51-42-06.SDR SWIA202157503Floor Support · corrodedRH PRESSURE FLOOR SILL HAS MULTIPLE SPOTS OF CORROSION FROM F.S. 409.00+128 TO F.S. 559.00 (C-CHECK RO 4/12/2021) REPAIRED RH PRESSURE SILL FROM FS409+128 TO FS559 IAW REO 601R-53-41-666 REV-C DATED 2012-11-06. COMPLETED TASK CARD 51-900-1003-SKY AND ATSDR SWIA202157502Floor Support · corrodedLH PRESSURE FLOOR SILL HAS MULTIPLE SPOTS OF CORROSION FROM F.S. 409.00+128 TO F.S. 559.00 (C-CHECK RO 4/12/2021) REPAIRED LH PRESSURE SILL FROM FS409+128 TO FS559 IAW REO 601R-53-41-666 REV-C DATED 2012-11-06. COMPLETED TASK CARD 51-900-1003-SKY AND ATSDR SWIA202156912Floor Support · corroded* FLOOR SILL FWD OF THE SERVICE DOOR CORRODED AT APROX. F.S.331.00. (C-CHECK) RO 3/10/2021 FLOOR SILL FWD OF SERVICE DOOR REMOVED AND REPLACED IAW CRJ200 SRM 51-42-06, 51-42-13, 51-45-00SDR SWAA2021030949988Web · crackedCRACK WEB - INTERCOSTAL LOC BS 827 TO BS 847 AT LEVEL S- 25L AT AFT CARGO COMPARTMENT / REPLACED WEB-INTERCOSTAL LOC BS 827 TO BS 847 AT LEVEL STR-25L AFT CARGO COMPARTMENT IAW SRM B737-700 51-40-02 AND DRAWING 146A7502 PART USED 146A7505-9SDR SWIA202156548Angle · corrodedAFTER REMOVAL OF PAX DOOR LOWER SILL AREA, MID CAP ANGLE, FOUND THE KICKPLATE ANGLE TO BE EXFOLIATED (C-CHECK) RO 3/2/2021 REMOVED CORROSION FOUND TO BE OUT OF LIMITS, REMOVED AND REPLACED PAX DOOR SURROUND KICKPLATE ANGLE IAW CRJ700 SRM 51-42-06-001-001-SDR SWIA202156547Intercostal · corrodedWHILE ACCESSING FOR 320.00 FRAME DD0 INTERCOSTAL FOUND TO BE CORRODED. (C-CHECK) RO 3/2/2021 REMOVED CORROSION AND FOUND INTERCOSTAL TO BE OUT OF LIMITS. REPLACED INTERCOSTAL REF CRJ-700 SRM 51-42-06-001-001-A01 AND DWG 601R31702 REV -N. COMPLIED WITH TASKSDR AALA202103031805Door Sill · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT RIGHT HAND PASSENGER / CREW DOOR CUT OUT LOWER SILL AT FR 68 AND S23R. REPAIRED LOWER SILL PER SRM 53-41-14-300-001 FIG 001, SHEET 03.SDR A6WA202102177640Floor Support · corrodedCORROSION COMMON TO PRESSURE FLOOR ANGLE AT FUSELAGE STATION 529+9 TO FUSELAGE STATION 529+11, RBL 40 TO RBL 42. ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED CORROSION FS 529.00 + 9 TO FS 529.00 + 11 RBL 40 TO RBL 42. .7 INCH WIDE X 1.5 INCH LONG. PERFORMEDSDR A6WA202102177641Floor Support · corrodedCORROSION COMMON TO PRESSURE FLOOR ANGLE AT FUSELAGE STATION 513.00+10 TO FUSELAGE STATION 529 RBL 40 TO RBL 42. ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED CORROSION FS 513.00+10 TO FS 529. RBL 40 TO RBL 42, SPOT P1, .3 INCH WIDE X .6 INCH LONG. P2, .4 INCHSDR A6WA202102167636Strap · corrodedCORROSION COMMON TO FLOOR SUPPORT AT FUSELAGE STATION 559.00 LBL 37 TO LBL 42. ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED AND INSTALLED NEW FABRICATED FLOOR SUPPORT AT FUSELAGE STATION 559.00 LBL 37 TO LBL 42. REF CRJ200 SRM 53-41-43 REV 38.SDR A6WA202102167653Floorbeam · corrodedCORROSION COMMON TO PRESSURE FLOOR ANGLE AT FUSELAGE STATION 513.00 TO 513.00+5 LBL 36 TO LBL 42. ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED CORROSION FROM PRESSURE FLOOR ANGLE AT FS 513.00 TO FS 513.0+5 LBL 36 TO LBL 42. EVALUATED BLEND AREA FOUND TO BE WSDR A6WA202102167658Floor Support · corrodedCORROSION COMMON TO PRESSURE FLOOR ANGLE AT FUSELAGE STA 461.00+12 LBL362 TO LBL42 ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED CORROSION FROM PRESSURE FLOOR ANGLE AT FS461+12 LBL 36 TO LBL 42. EVALUATED BLEND AREA FOUND TO BE WITHIN ALLOWABLE LIMITS.HFEC INSSDR A6WA202102167656Floor Support · corrodedCORROSION COMMON TO PRESSURE FLOOR ANGLE AT FS 409.00+128+12 LBL 37. ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED CORROSION FROM PRESSURE FLOOR ANGLE AT FS 409.00+128+12 LBL 37.EVALUATED BLEND AREA FOUND TO BE WITHIN ALLOWABLE LIMITS. HFEC INSPECTION PERFORMESDR A6WA202102167655Floor Support · corrodedCORROSION COMMON TO PRESSURE FLOOR ANGLE AT FUSELAGE STATION 461 LBL 416 TO LBL 42. ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED CORROSION FROM PRESSURE FLOOR ANGLE AT FS 461.00 LBL 41 TO LBL TO LBL 42. EVALUATED BLEND AREA FOUND TO BE WITHIN ALLOWABLE LIMITSDR N6WA2021021001Door Sill · corrodedFOUND CORROSION ON SVC DOOR SILL ANGLE. REMOVED AND REPLACED SERVICE DOOR SILL ANGLE IAW CRJ 700 SRM 51-42-06 AND 51-42-21SDR DALA2021021100795Floor Support · corrodedDURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON FLOOR STRINGERS ON STA.640-660 AND LBL 16.10 IS 0.071". STRINGER REPAIRED PER SRM. (LP 1727189)SDR KCSA202102101008Stiffener · crackedWEB STIFFENER IS CRACKED AT BOTTOM FASTENER HOLE STA 340 RBL 10SDR DALA2021021000779Floor Support · corrodedSHIP 3303 CORROSION FLOOR BEAM -Y1456 BTW FR12 TO FR14 IN PASSENGER CABIN SSI 531172-01-2. CORRECTIVE ACTION: REPLACED FLOOR BEAM -Y1456 BTW FR11 TO FR18 AS PER SRM A330 51-42. (1726941)SDR REXA2021050500197Striker · corrodedSERVICE DOOR LOWER SEAL STRIKER HAS CORROSION AROUND FASTENER HOLES. - REMOVED/REPLACED SERVICE DOOR SEAL STRIKE IAW CRJ700 AMM 51-42-06-001-001-A01 AND INSTALLED SERVICE DOOR STOPS IAW CRJ700 AMM'S 53-21-27-400-802(A01) THEN PERFORMED LEAK/OPS CHECK IAW CRJ70SDR REXA2021050400136Floor Support · corrodedSERVICE DOOR UPPER FLOOR SILL ANGLE IS CORRODED ON O/B EDGE. - LOCATED, DRILLED AND INSTALLED NEW SERVICEABLE FLOOR SILL ANGLE P/N SH670-31986-1 AND MOUNTING ANGLE P/N SH670-31996-35 IAW CRJ 700 SRM 51-40-11-001-001-A01, AND 51-42-06-001-001-A01. WVAC EMP STASDR REXA2021050400130Angle · corrodedLEFT & RIGHT INTERNAL REAR SPAR (FS 693) AUX SECTION (BLOWOUT PANEL) HAS NUMEROUS CORRODED NUTPLATES IN ANGLES. L/R FWD LOWER ANGLE CORRODED. - REMOVED & REPLACED LEFT AND RIGHT TIRE BLOWOUT PANEL SUPPORT ANGLES IAW CRJ 700 SRM 51-42-21-001-001-A01.SDR SWIA202157433Angle · corroded* PASSENGER DOOR SILL MID CAP ANGLE CORRODED (C-CHECK RO 4/4/2021) CORRODED PASSENGER DOOR SILL MID CAP ANGLE REMOVED AND REPLACED WITH NEW ANGLE (P/N SH670-31825-7), REF CRJ700 SRM 51-41-02-001-001 A01. SEE CONTINUATION CARD FOR FURTHER DETAILS.SDR SWIA202156891Support · damaged* LH SILL AT FS 559.0+16 TO FS 559.0+32 HAS A MISDRILLED HOLE (C-CHECK) RO 3/10/2021 REPAIRED LH SILL AT FS 559.0+16 TO FS 559.0+32. REF REO 601R-53-51-560 REV. -- DATED 2021-02-12. COMPLIED WITH 51-900-1003-SKY AND SEE CONTINUATION CARD FOR DETAILSSDR SWIA202156890Strap · corroded* LH TOP STRAP @ FS 559.0 RBL 27 TO SILL HAS CORROSION (C-CHECK) RO 3/10/2021 REMOVED CORROSION ON L/H STOP STAP AT FS559 LBL27 TO FLOOR SILL REF CRJ 200 SRM 51-21-06, PART WAS OUT OF LIMITS PER 53-00-00, REMOVED AND REPLACED STRAP REF CRJ 200 SRM 51-42-0
Back to JASC 5320