JASC 5321
Service difficulty reports · 49,350
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2024022102371Floor Panel · puncturedSHIP 3128 PUNCTURE ON FLOOR PANEL IN AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED PER ER/A 615794-14. (0211105)SDR AALA202403081294Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: CABIN FLOOR PANEL 222EF HAS DELAMINATION. REPLACED FLOOR PANEL PER SRM 53-02-00-300-011 AND IRM 9701.SDR AALA202402261982Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: DELAMINATED FLOOR PANEL (222EF) AT FORWARD GALLEY AREA. REPLACED FLOOR PANEL 222EF WITH NEW REPLACEMENT MATERIAL PER SRM 53-12-00-300-006.SDR SWAA2024031553528Floor Panel · delaminatedDELAMINATED FLOOR PANEL 241AEF AT PASSENGER CABIN 2024-124216<[01] TOOL USED: CALIPER P/N: 500-197-30 S/N: B20189520 DUE DATE: 17-JAN-25.;[02] TOOL USED: HOT BONDER P/N: HCS9200B-AV; S/N:18196126; DUE DATE:26/MAR/24;[03] TOOL USED: SCALE P/N: SCA-301; S/N: AE-SDR SWAA2024031253591Floor Panel · tornAFT FLOOR PANEL 242VF AFT R/H CORNER TORN<[01] AFT FLOOR PANEL 242VF WITH AFT R/H CORNER TORN WAS REPAIRED IAW SRM 53-00-50-2R-6.;[02] VERIFIED CORRECTIVE ACTION 1SDR IPXA2024021835530Floor Panel · damaged*MAJOR REPAIR* ( SHEET -METAL EVAL ) - POSITION 7C - MCD FLOOR BOARD ( DAMAGED UPON REMOVAL REMOVAL. AFT LH FASTENER INSERT ( MARKED WITH TAPE. UNDERSIDE FWD PANEL LAYER PEELING-SEPARATED ( MARKED WITH TAPE.) INSTALLED POS 7 MCD FABRICATED FLOOR PNL PER AMMSDR SWAA2024022053491Floor Panel · crackedRAMP REPORTS THEY FOUND A CRACK IN THE FORWARD CARGO HOLD FLOOR.<[01] OK TO CONTINUE PER MEL 25-6-01 SP1B. FWD CARGO BIN BLOCKED OFF.;[02] OK TO CONTINUE PER MEL 25-16-01 SP1B. FWD CARGO BIN BLOCKED OFF.<BR>RE-ENTER CORRECTIVE ACTION FOR CORRECT MEL REFERENCE.SDR ASAA2024021648540Floor Panel · delaminatedFLOOR PANEL 141A5810-767 IS DELAMNIATED. GROUNDED - YES. REPAIRED DELAMINATION ON FLOORPANEL 141A5810-767 AND INSTALLED INSERTS IAW B737-900ER SRM 53-00-50-2R-1, BOEING DWG 141A5810 REV. C.SDR ASAA2024021648539Floor Panel · delaminatedFLOOR PANEL 141A5810-728 HAS CORRODED INSERTS. GROUNDED - YES. REPAIRED DELAMINATION AND INSTALLED NEW INSERTS IN FLOOR PANEL # 141A5810-728 IAW B737-900ER SRM 53-00-50-2R-1, BOEING DWG 141A5810 REV.C.SDR SWAA2024031453126Floor Panel · crackedMULTIPLES CRACKS ON PANEL 211A (MARKED)<[01] UPON INVESTIGATION FOUND COCKPIT PANEL 211A IS ACTUALLY 212B. FOUND ONE CRACK ON PANEL 212B; REPAIRED PANEL 212B PER CMM 25-00-66 REPAIR 3-1 PARAGRAPH 4 APPLIED FIBERGLASS AT 10:30 AM;[02] VERIFIED 24HR CURE OF FIBESDR SWAA2024031352838Floor Panel · pulledAFT FLOOR PANEL 241AAF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FABRICATED NEW AFT FLOOR PANEL 241AAF IAW SRM 53-00-50-2R-0 AND BOEING DWG 147A5810 ID:0008;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2024031352840Floor Panel · pulledAFT FLOOR PANEL 242WF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO THE EXTENT OF DAMAGE; REPLACED AFT FLOOR PANEL 242WF IAW SRM 51-10-02-0G-0 PARA 9 AND AIPC 53-21-00-26 ITEM 195.;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2024031352826Floor Panel · pulledFLOOR PANEL 241UF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FLOOR PANEL 241UF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024031352841Floor Panel · pulledFWD FLOOR PANEL 221BF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 221BF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024031352828Floor Panel · pulledFWD FLOOR PANEL 221DF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 221DF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024031352831Floor Panel · pulledFWD FLOOR PANEL 222BF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 222BF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024031352834Floor Panel · pulledFWD FLOOR PANEL 231AF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 231AF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024031352835Floor Panel · pulledFWD FLOOR PANEL 231BF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO EXTENT OF DAMAGE FLOOR PANEL 231BF WAS REPLACED IAW SRM 51-10-02-0G-0 PAR 9.A (1).;[02] VERIFIED CORRECTIVE ACTION 1SDR SWAA2024031252836Floor Panel · pulledAFT FLOOR PANEL 241XF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] PULLED STRANDS ON AFT FLOOR PANEL 241XF UPPER SKIN HAVE BEEN REPAIRED IAW SRM 53-00-50-2R-1.;[02] FINAL INSPECTION. JOB COMPLETE.SDR SWAA2024031252837Floor Panel · pulledAFT FLOOR PANEL 241ZF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] AFT FLOOR PANEL 241ZF UPPER SKIN DAMAGE HAS BEEN REPAIRED IAW SRM 53-00-50-2R-1.<BR><BR>ATTACHED CURE SHEETS TO THIS FAULT.;[02] VERIFIED REPAIR OF FLOOR PANEL 241ZF UPPER SKIN IAW SRM 53-00-50SDR SWAA2024031252821Floor Panel · pulledAFT FLOOR PANEL 241ABFF UPPER SKIN HAS AREAS OF PULLED STRANDS. PANEL SHOULD BE 241ABF<[01] AREAS OF PULLED STRANDS ON FLOOR PANEL 241ABF WERE REPAIRED IAW SRM 53-00-50-2R-1.<BR><BR>DOWNLOADED CURE SHEETS AND TAPE.;[02] VERIFIED FLOOR PANEL 241ABF WAS REPAIREDSDR SWAA2024031252839Floor Panel · pulledAFT FLOOR PANEL 241ACF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] AFT FLOOR PANEL 241ACF UPPER AND LOWER SKIN DAMAGED AREAS HAVE BEEN REPAIRED IAW SRM 53-00-50-2R-1.<BR><BR>ATTACHED CURE SHEETS TO THIS FAULT.;[02] VERIFIED REPAIR OF FLOOR PANEL 241ACF PER SRSDR SWAA2024031252822Floor Panel · pulledAFT FLOOR PANEL 241ADF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] AREAS OF PULLED STRANDS ON AFT FLOOR PANEL 241ADF UPPER SKIN WAS REPAIRED IAW SRM 53-00-50-2R-1.;[02] FINAL INSPECTION. JOB COMPLETE.SDR SWAA2024031252823Floor Panel · pulledAFT FLOOR PANEL 242TF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] AFT FLOOR PANEL 242TF UPPER SKIN AREAS OF PULLED STRANDS WERE REPAIRED IAW SRM 53-00-50-2R-1.;[02] VERIFIED REPAIR OF FLOOR PANEL 242TF UPPER SKIN IAW SRM 53-00-50-2R-1.;[03] WORKSCOPE IS COMPLSDR SWAA2024031252825Floor Panel · pulledAFT FLOOR PANEL 242VF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] AFT FLOOR PANEL 242VF WITH UPPER SKIN HAS AREAS OF PULLED STRANDS WAS REPAIRED IAW SRM 53-00-50-2R-1.;[02] VERIFIED CORRECTIVE ACTION 1SDR SWAA2024031252842Floor Panel · pulledFWD FLOOR PANEL 221CF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] REPAIRED AREAS OF PULLED STRANDS ON UPPER SKIN OF FWD FLOOR PANEL 221CF IAW SRM 53-00-50-2R-1.;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2024031252830Floor Panel · pulledFWD FLOOR PANEL 222AF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] AREAS OF PULLED STRANDS ON UPPER SKIN OF FWD FLOOR PANEL 222AF WAS REPAIRED IAW SRM 53-00-50-2R-1.;[02] FINAL INSPECTION. JOB COMPLETE.SDR SWAA2024031252832Floor Panel · pulledFWD FLOOR PANEL 222CF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 222CF UPPER SKIN WAS REPAIRED IAW SRM 53-00-50-2R-1 AND BAC DWG 141A5810 ID: 245.;[02] INFORMATION ENTERED ON ITEM 1 WAS ENTERED IN ERROR. THIS IS AN INSPECTOR BLOCK.;[03] FWD FSDR SWAA2024031252833Floor Panel · pulledFWD FLOOR PANEL 222DF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 222DF WITH UPPER SKIN PULLED STRANDS WAS REPAIRED IAW SRM 53-00-50-2R-1 AND BAC DWG 141A5810 ID:185.;[02] VERIFIED CORRECTIVE ACTION 1.SDR ASAA2024021648256Floorboard · corrodedFLOOR PANEL 141A5810-763 HAS MISSING AND CORODED INSERTS. GROUNDED - YES. REPAIRED FLOOR PANEL 141A5810-763 DAMAGED FLOOR PANEL BY PREFORMING WET LAY UP PERMANENT REPAIR AND REPLACED DAMAGE INSERTS IAW B737-900ER SRM 53-00-50-2R-6, 53-00-50-2R-0.SDR ASAA2024021648255Floor Panel · corrodedFLOOR PANEL 141A5810-236 HAS CORRODED INSERTS. GROUNDED - YES. EVALUATED AND REPAIRED 10EA INSERTS IAW ASA B737-900ER SRM 53-0-50-2R-0. APPLIED SKYFLEX TAPE IAW ASA B737-900ER DWG 141A5810 REV C.SDR ASAA2024021648094Floor Panel · delaminatedFLOOR PANEL 141A5810-768 IS DELAMNIATED. GROUNDED - YES. EVALUATED AND REPAIRED DELAMINATED AREA IAW ASA B737-900ER SRM 53-00-50-2R-1. REMOVED AND REPLACED 19EA INSERTS IAW ASA B737-900ER SRM 53-00-50-2R-0. APPLIED TAPE IAW ASA B737-900ER DWG 141A581 REV C.SDR SWAA2024031552656Floor Panel · crackedCRACK FLOOR PANEL 241AEF AT PASSENGER CABIN 2024-124097<[01] TOOL USED: CALIPER P/N: 500-197-30 S/N: B20189520 DUE DATE: 17-JAN-25;[02] TOOL USED: HOT BONDER P/N:HCS9200B-AV; S/N:18196126 DUE DATE:26/MAR/24;[03] TOOL USED: SCALE P/N: SCA-301; S/N: AE-412135; DSDR ASAA2024021548259Floor Panel · delaminatedFLOOR PANEL 147A5810-439 HAS CORRODED INSERTS AND IS DELAMINATED. GROUNDED - YES. REPAIRED FLOOR PANEL 147A5810-439 NOTED DAMAGE BY PERFORMING WET LAY UP REPAIR TO ONE FACESHEET & REPLACED INSERTS IAW B737-900ER SRM 53-00-50-2R-0.SDR ASAA2024021548244Floorboard · corrodedFLOOR PANEL 147A5810-443 HAS CORRODED INSERTS. GROUNDED - YES. REPAIRED FLOOR PANEL 147A5810-443 OF CORRODED INSERTS,REMOVED AND REPLACED CORRODED INSERTS IAW B737-900ER SRM 53-00-50-2R-0.SDR ASAA2024021548243Floor Panel · corrodedFLOOR PANEL 147A5810-398 HAS CORRODED INSERTS. GROUNDED - YES. REMOVED AND REPLACED CORRODED INSERTS ON FLOOR PANEL 147A5810-398 IAW B737-900ER SRM 53-00-50-2R-0.SDR ASAA2024021548241Floor Panel · corrodedFLOOR PANEL 147A5810-440 HAS MISSING AND CORRODED INSERTS. GROUNDED - YES. REPAIRED FLOOR PANEL 147A5810-440 BY PREFORMING PERMANENT WET LAY UP REPAIR TO ONE FACESHEET + REMOVED/ REPLACED INSERTS IAW B737-900ER SRM 53-00-50-2R-0.SDR ASAA2024021548091Floor Panel · delaminatedFLOOR PANEL 147A5810-445 IS DELAMINATED. GROUNDED - YES. REPAIRED FLOOR PANEL 147A5810-445 NOTED DAMAGE BY PREFORMING WET LAY UP REPAIR TO ONE FACE SHEET IAW B737-900ER SRM 53-00-50-2R-0.SDR ASAA2024021548067Floor Panel · delaminatedMAIN CABIN AFT WET AREA BOARD DELAME P/N 147A5810-108. GROUNDED - YES. COMPLETED WET LAY UP REPAIR, REMOVED AND REPLACED 17 INSERTS ON MAIN CABIN AFT WET AREA BOARD PN: 147A5810-108 IAW B737-900ER SRM 53-00-50-2R-7AND 53-00-50-2R-0.SDR ASAA2024021548066Floor Panel · delaminatedMAIN CABIN AFT WET AREA BOARD DELAME P/N 147A5810-445. GROUNDED - YES. COMPLETED WET LAY UP REPAIR AND REMOVE AND REPLLACE INSERTS ON MAIN CABIN AFT WET AREA FLOOR BOARD PN:147A5810-45 IAW B737-900ER SRM 53-00-50-2R-7 REPAIR 7 AND 53-00-50-2R-0.SDR AALA202402165537Floor Panel · delaminatedAIRCRAFT IN BASE MAINETNANCE: FORWARD CARGO COMPARTMENT FLOOR PANEL 131YF DELAMINATED. MAINTENANCE REPLACED FLOOR PANEL.SDR SWAA2024021552483Floor Panel · crackedAFT CARGO LINER 141DW MULTIPLE CRACKS ON BOTTOM EDGE. REMOVED AND REPLACED AFT CARGO LINER 141DW IAW AMM 50-10-02.SDR SWAA2024031352136Floor Panel · pulledFLOOR PANEL 241AF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO THE EXTENT OF DAMAGE; FABRICATED FLOOR PANEL 241AF IAW SRM 53-00-50-2R-0.;[02] ADDITION TO ITEM 1: IAW SRM 53-00-50-2R-0 AND BOEING DWG 144A5810 SHEET:8.;[03] VERIFIED CORRECTIVE ACTION ITEMSDR SWAA2024031352137Floor Panel · pulledFLOOR PANEL 241DF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO THE EXTENT OF DAMAGE; FABRICATED NEW FLOOR PANEL 241DF IAW SRM 53-00-50-2R-0.;[02] VERIFIED CORRECTIVE ACTION 1.SDR SWAA2024031352135Floor Panel · pulledFLOOR PANEL 241EF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO THE EXTENT OF DAMAGE; FABRICATED NEW FLOOR PANEL 241EF IAW SRM 53-00-50-2R-0.;[02] VERIFIED CORRECTIVE ACTION 1.SDR SWAA2024031352138Floor Panel · pulledFLOOR PANEL 241FF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FLOOR PANEL 241FF WITH PULLED STRANDS WAS REPLACED BY FABRICATING A NEW PANEL IAW SRM 53-00-50-2R-0 AND DWG 144A5810 ID:0013;[02] VERIFIED FLOOR PANEL 241FF WAS REPLACED BY FABRICATING A NEW PANEL SDR SWAA2024031352139Floor Panel · pulledFLOOR PANEL 242CF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FLOOR PANEL 242CF WITH PULLED STRANDS WAS REPLACED BY FABRICATING A NEW PANEL IAW SRM 53-00-50-2R-0 AND DWG 144A5810 ID:0006;[02] JOB COMPLETE.SDR SWAA2024031352423Floor Panel · deterioratedDETERIORATED SLEEVE FLOOR PANEL 241ABF AT AFT GALLEY AND LAV (5 EA) 2024-123230<[01] REPLACED SLEEVE FLOOR PANEL 241ABF AT AFT GALLEY AND LAV (5 EA) B737-700 SRM 53-00-50-2R-0 REPAIR GENERAL PARAGRAPH 5.B(2) S (1). TOOL USED: SCALE: P/N: CL5000 S/N: AE-39087 DSDR ASAA2024021448224Floor Panel · delaminatedMAIN CABIN FWD WET AREA FLOOR BOARD DELAME P/N 141A5810-763. GROUNDED - YES. REPAIRED MAIN CABIN FWD WET AREA FLOOR BOARD P/N 141A5810-763 BY PREFORMING PERMANENT WET LAYUP REPAIR IAW B737-900 SRM 53-00-50-2R-0, 53-00-50-2R-7.SDR ASAA2024021448223Floor Panel · delaminatedMAIN CABN FWD WET AREA FLOOR BOARD DELAME P/N 141A5810-766. GROUNDED - YES. REPAIRED MAIN CABIN FWD WET AREA FLOOR BOARD P/N 141A5810-766 BY PREFORMING PERMANENT WET LAYUP REPAIR IAW B737-900ER SRM 53-00-50-2R-7, 53-00-50-2R-0.
Back to JASC 5321