JASC 5321
Service difficulty reports · 49,350
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2023120646978Floor Panel · delaminatedLESSOR ITEM: FLOOR PANEL 23CBF - MINIMUM 4 AREAS OF DELAMINATION GROUNDED - YES. PANEL FOUND TO BE OUT OF LIMITS IAW A320 SRM 53-02-00-283-001. PANEL RECEIVED- P/N= E5367191800000. PO# 1077193.1. PANEL WILL BE INSTALLED ON N/R # 35077SDR ASAA2023120646977Floor Panel · delaminatedLESSOR ITEM: FLOOR PANEL 232DF -MINIMUM 5 AREAS OF DELAMINATION GROUNDED - YES. PANEL FOUND TO BE OUT OF LIMITS IAW A320 SRM 53-02-00-283-001. PANEL RECEIVED- P/N= E5367191900000. PO # 1077204.1. PANEL WILL BE INSTALLED ON N/R # 35077SDR ASAA2023120646976Floor Panel · delaminatedLESSOR ITEM: FLOOR PANEL 231XF - MINIMUM 2 AREAS OF DELAMINATION GROUNDED - YES. FOUND DELAMINATION TO BE OUT OF LIMITS IAW A320 SRM 53-02-00-283-001. RECEIVED NEW PANEL ALT P/N # E5367150500000 IAW A320 ASA 53-12-01-32V PO # 1077189.1. NEW PANEL TO BE INSTALLSDR ASAA2023120646975Floor Panel · delaminatedLESSOR ITEM: FLOOR PANEL 231EF-MINIMUM 3 AREAS OF DELAMINATION GROUNDED - YES. FOUND DELAMINATION TO BE OUT OF LIMITS IAW A320 SRM 53-02-00-283-001. RECEIVED NEW PANEL ALT P/N # E5367191000000 OF P/N # E5367162400000 IAW A320 ASA 53-12-01-32V PO # 1077190.1. NSDR ASAA2023120646974Floor Panel · delaminatedLESSOR ITEM: FLOOR PANEL 231BF -MINIMUM 4 AREAS OF DELAMINATION GROUNDED - YES. FOUND DELAMINATION TO BE OUT OF LIMITS IAW A320 SRM 53-02-00-283-001. RECEIVED NEW PANEL ALT P/N # E5367190100000 OF P/N # E5367147700000 P/O # 967910.1 IAW A320 ASA 53-12-01-32V. SDR SWAA2023122827970Floor Panel · delaminatedFOLLOWING FWD WET AREA FLOOR BOARDS HAVE DENTS/DELAMINATION; 231CF; 231BF; 231AF; 222DF; 222CF; 221GF; 221FF; 221EF; 221CF; AND 221DF.<[01] REPLACED FLOOR PANEL 231AF ON TTG8Q00P6GLG.<BR>REPLACED FLOOR PANEL 231BF ON TTG8Q00P6GLE.<BR>REPLACED FLOOR PANEL 231CFSDR SWAA2023122827972Floor Panel · delaminated221BF AND 221AF FWD WET AREA FLOOR BOARDS HAVE DENTS/DELAMINATION.<[01] NEW FLOOR PANEL 221BF INSTALLED ON TTG8Q00P6GMR<BR>NEW FLOOR PANEL 221AF INSTALLED ON TTG8Q00P6GM4;[02] NEW FLOOR PANEL 221BF INSTALLED ON TTG8Q00P6GM2<BR>NEW FLOOR PANEL 221AF INSTALLED OSDR SWAA2023122028068Floor Panel · delaminatedPASSENGER CABIN FLOOR PANEL 241AF HAS DELAMINATION DAMAGE ON TOP.<[01] UPDATED STEPS 4;5.;[02] UPDATED STEP 4 AND 5;[03] IDENTIFIED FLOOR PANEL 241AF IAW SRM 53-00-50-0I-1 FIG. SHEET 1 TABLE 4 AND FOUND DAMAGE TO BE OUT OF ECONOMICAL REPAIR. NEW PANEL TO BE FASDR FDEA202312051917Floorboard · damagedZONE 220 COURIER FLOORBOARD 221BF DAMAGED FABRICATED ZONE 220 COURIER FLOORBOARD 221BF ON VTMAE TRAVELER #T23/1718651 IAW DWG SRZ-25-005 REVISION R MAJOR REPAIRSDR FDEA202312051915Floorboard · damagedZONE 220 COURIER FLOORBOARD 221MBF DAMAGED FABRICATED ZONE 220 FLOORBOARD 221MBF ON VTMAE TRAVELER # T23/1718650 IAW DWG SRZ- 25-005 REVISION R MAJOR REPAIRSDR FDEA202312051914Floorboard · damagedZONE 220 FLOORBOARD 221AF DAMAGED FABRICATED ZONE 220 FLOORBOARD 221AF ON VTMAE TRAVELER # T23/1718653 IAW DWG SRZ- 25-005 REVISION R MAJOR REPAIRSDR FDEA202312051913Floorboard · damagedZONE 220 COURIER FLOORBOARD 222AF DAMAGED FABRICATED ZONE 220 COURIER FLOORBOARD 222AF ON VTMAE TRAVELER # T23/1718647 IAW DWG SRZ-25-005 REVISION R MAJOR REPAIRSDR FDEA202312051912Floorboard · damagedZONE 220 FLOORBOARD 222MAF DAMAGED FABRICATED ZONE 220 FLOORBOARD 222MAF ON VTMAE TRAVELER # T23/1718633 IAW DWG SRZ- 25-005 REVISION R MAJOR REPAIRSDR FDEA202312051911Floorboard · damagedZONE 220 COURIER FLOORBOARD 222BF DAMAGED FABRICATED ZONE 220 COURIER FLOORBOARD 222BF ON VTMAE TRAVELER # T23/1718643 IAW DWG SRZ-25-005 REVISION R MAJOR REPAIRSDR FDEA202312051908Floorboard · damagedZONE 220 COURIER FLOORBOARD 222MAF DAMGED FABRICATED ZONE 220 COUREIR FLOORBOARD 222MAF ON VTMAE TRAVELER # T23/1717925 IAW DWG SRZ-25-005 REVISION R MAJOR REPAIRSDR FDEA202312051906Floorboard · damagedZONE 220 FLOORBOARD 222AF DAMAGED FABRICATED ZONE 220 FLOORBOARD 222AF ON VTMAE TRAVELR # T23/1717922 IAW DWG SRZ-25- 005 REVISION R, MAJOR REPAIRSDR FDEA202312051905Floorboard · damagedZONE 220 COURIER FLOORBOARD 221BF DAMAGED FABRICATED ZONE 220 FLOORBOARD 221BF ON VTMAE TRAVELER # T23/1717928 IAW DWG SRZ- 25-005 REVISION R, MAJOR REPAIRSDR SWAA2024011627852Floor Panel · delaminatedPASSENGER CABIN FLOOR PANEL 241DF HAS DELAMINATION<[01] IDENTIFIED FLOORBOARD 241DF IAW SRM 53-00-50-0I-1 FIG. 4 SHEET 1 TABLE 4 AND FOUND DAMAGE TO BE OUT OF ECONOMICAL REPAIR. NEW PANEL TO BE FABRICATED IAW SRM 53-00-50-2R-0 PARA 1.A NOTE. <BR>CUT NEW PANEL SDR SWAA2024011627860Floor Panel · delaminatedPASSENGER CABIN FLOOR PANEL 241AF HAS DELAMINATION<[01] IDENTIFIED FLOORBOARD 241AF IAW SRM 53-00-50-0I-1 FIG. 4 SHEET 1 TABLE 4 AND FOUND DAMAGE TO BE OUT OF ECONOMICAL REPAIR. NEW PANEL TO BE FABRICATED IAW SRM 53-00-50-2R-0 PARA 1.A NOTE. <BR>CUT NEW PANEL SDR SWAA2024011627865Floor Panel · delaminatedPASSENGER CABIN FLOOR PANEL 231XF HAS DELAMINATION<[01] IDENTIFIED FLOORBOARD 231XF IAW SRM 53-00-50-0I-1 FIG. 4 SHEET 1 TABLE 4 AND FOUND DAMAGE TO BE OUT OF ECONOMICAL REPAIR. NEW PANEL TO BE FABRICATED IAW SRM 53-00-50-2R-0 PARA 1.A NOTE. <BR>CUT NEW PANEL SDR ASAA2023120446894Floor Panel · delaminatedFLOOR PANEL 141A5810-235 REQ EVAULATION AND REPAIR. GROUNDED - YES. ACCOMPLISHED A PERMANENT REPAIR TO FLOOR PANEL 141A5810-235 IAW B737-900ER SRM 53-00-50-2R-7.SDR ASAA2023120446893Floor Panel · delaminatedFLOOR PANEL 141A5810-236 REQ EVAULATION AND REPAIR. GROUNDED - YES. REPAIRED FLOOR PANEL 141A5810-236 IAW B737-900ER SRM 53-00-50-2R-7.SDR REXA2022122601057Floor Panel · crackedFWD EQUIPMENT COMPARTMENT LH FLOOR CRACKED AT FS 193.00. REPAIRED IAW CRJ900 SRM 53-11-43-201-001-A01.SDR SWAA2024011627381Floor Panel · crackedCRACK FLOOR PANEL 140BF AT AFT CARGO COMPARTMENT 2023-751551 CRACK FLOOR PANEL 140EF AT AFT CARGO COMPARTMENT<[01] REPLACED FLOOR PANEL 140BF AT AFT CARGO COMPARTMENT IAW AMM B737-800 25-52-01-201-801 AND DWG 453A2610 SHEET 38 REV C MATERIAL USED ALUMINIUM SHESDR SWAA2023122926839Floor Panel · delaminatedDELAMINATED FLOOR PANEL 241AEF AT AFT GALLEY AND LAV 2023-748293<[01] CALIPER: 500-197-30 S/N:15120589 DUE DATE: 13-FEB-24.;[02] TOOL USED: HOT BONDER P/N: HCS9200B-AV S/N: 18185733 DUE DATE: 23-JAN-24.;[03] TOOL USED: SCALE P/N: CR5200 S/N: 8343150722 DUE DATSDR SWAA2023122926840Floor Panel · crackedCRACK FLOOR PANEL 241AEF AT AFT GALLEY AND LAV 2023-748294<[01] TOOL USED CALIPER: 500-197-30 S/N:15120589 DUE DATE: 13-FEB-24.;[02] TOOL USED: HOT BONDER P/N: HCS9200B-AV S/N: 18185733 DUE DATE: 23-JAN-24.;[03] TOOL USED: SCALE P/N: CR5200 S/N: 8343150722 DUESDR SWAA2024011226053Floor Panel · peelingCABIN CENTER SECTION FLOOR PANEL 241FF UPPER SURFACE LAYER HAS PEELED FIBERS. 124-003<[01] RECEIVED AND REPLACED PANEL 241FF AS PER SRM 53-00-51-1A-1.;[02] VERIFIED NEW PANNEL. NOTE: INSTALLATION WILL BE ACCOMPLISHED ON ROUTINE CLOSING CARD.SDR SWAA2024010326154Floor Panel · pulledAFT FLOOR PANEL 241AAF UPPER SKIN HAS PULLED STRANDS.<[01] AFT FLOOR PANEL 241AAF UPPER SKIN WITH PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] PANEL REPLACED. JOB COMPLETE.SDR SWAA2024010326151Floor Panel · pulledAFT FLOOR PANEL 241ACF UPPER SKIN HAS PULLED STRANDS.<[01] AFT FLOOR PANEL 241ACF UPPER SKIN HAD PULLED STRANDS REPAIRED IAW SRM 53-00-50-2R-1;[02] VERIFIED FLOOR PANEL 241ACF IS REPAIRED SRM 53-00-50-2R-1;[03] WORKSCOPE IS COMPLETE.SDR SWAA2024010326152Floor Panel · pulledAFT FLOOR PANEL 241ADF UPPER SKIN HAS PULLED STRANDS.<[01] AFT FLOOR PANEL 241ADF UPPER SKIN WITH PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] PANEL REPLACED. JOB COMPLETE.SDR SWAA2024010326156Floor Panel · pulledAFT FLOOR PANEL 242VF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] REPAIRED AREAS OF PULLED STRANDS ON UPPER SKIN OF AFT FLOOR PANEL 242VF IAW SRM 53-00-50-2R-1.;[02] VERIFIED REPAIR OF UPPER SKIN OF FLOOR PANEL 242VF PER SRM 53-00-50-2R-1;[03] WORKSCOPE COMPLSDR SWAA2024010326157Floor Panel · deformedAFT FLOOR PANEL 242WF FWD I/B CORNER IS SOFT.<[01] REPAIRED FWD I/B CORNER ON AFT FLOOR PANEL 242WF IAW SRM 53-00-50-2R-6.;[02] VERIFIED REPAIR OF FLOOR PANEL 242WF IAW SRM 53-00-50-2R-6.;[03] WORKSCOPE COMPLETE.SDR SWAA2024010326168Floor Panel · pulledFWD FLOOR PANEL 221FF UPPER SKIN HAS AN AREA OF PULLED STRANDS.<[01] REPAIRED DAMAGED UPPER SKIN ON FWD FLOOR PANEL 221FF IAW SRM 53-00-50-2R-1.;[02] VERIFIED UPPER SKIN OF FLOOR PANEL 221FF REPAIRED PER SRM 53-00-50-2R-1;[03] WORKSCOPE COMPLETE.SDR SWAA2024010326161Floor Panel · pulledFWD FLOOR PANEL 221GF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 221GF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] PANEL REPLACED. JOB SDR SWAA2024010326169Floor Panel · pulledFWD FLOOR PANEL 222A UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 222A UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] PANEL REPLACED. JOB COSDR SWAA2024010326170Floor Panel · pulledFWD FLOOR PANEL 222B UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 222B UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] PANEL REPLACED. JOB COSDR SWAA2024010326163Floor Panel · pulledFWD FLOOR PANEL 222CF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 222CF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] PANEL REPLACED. JOB SDR SWAA2024010326173Floor Panel · pulledFWD FLOOR PANEL 231CF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 231CF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] PANEL REPLACED. JOB SDR SWAA2024010326164Floor Panel · pulledFWD FLOOR PANEL 232AF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 232AF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] PANEL REPLACED. JOB SDR SWI2024F00005Floorbeam · corrodedL/H OTBD FLOOR BEAM @ FS1031.0 HAS CORROSION (TOP SIDE) (C-CHECK RO 1/19/2024) REPAIRED FLOOR BEAM WITH NEW SECTION AT (LH IB) LBL 27.0 BETWEEN FS1026.00 TO FS1038.00 REF: CRJ700 SRM 53-00-41-201-001-A01 AND REO 670-53-61-2218 REV-- DATED 2023-12-18 . COSDR SWAA2024011225943Intercostal · crackedFWD CABIN WET AREA FLOOR SUPPORT INTERCOSTAL CRACKED @ BL-0 BETWEEN STA 277 AND STA 294.5 MKD DOT<[01] REMOVED AND REPLACED FWD CABIN WET AREA FLOOR SUPPORT INTERCOSTAL AT BL-0 BETWEEN STA 277 AND STA 294.5 AS PER SRM 51-40-02-0G-0 AND DRAWING NUMBER 141A5400.SDR SWAA2024011226052Floor Panel · peelingCABIN CENTER SECTION FLOOR PANEL 231XF UPPER LAYER HAS PEELED FIBERS. 124-001<[01] RECEIVED AND REPLACED PANEL 231XF AS PER SRM 53-00-50-1A-1.;[02] VERIFIED NEW PANEL. NOTE: PANEL INSTALLATION WILL BE DONE ON ROUTINE CARDSDR SWAA2024011226054Floor Panel · peelingCABIN CENTER SECTION FLOOR PANEL 241AF UPPER SURFACE LAYER HAS PEELED FIBERS. 124-002<[01] RECEIVED AND REPLACED PANEL 241AF AS PER SRM 53-00-50-1A-1.;[02] VERIFIED NEW PANEL NOTE: INSTALLATION WILL BE ACCOMPLISHED ON ROUTINE CARD.SDR SWAA2023122125969Floor Panel · pulledAFT FLOOR PANEL 241ACF HAS PULLED THROUGH INSERT<[01] FLOORBOARD 241ACF THROUGH INSERT REPAIR HAS BEEN FINISHED IAW SRM 53-00-50-2R-6.<BR><BR>ATTACHED CURE SHEETS TO THIS FAULT.;[02] VERIFIED FLOOR PANEL 241ACF REPAIR HAS BEEN PERFORMED SRM 53-00-50-2R-6.SDR IPXA2025022601370Floor Panel · damagedFOUND DAMAGE ON PANEL 194FR. 26 HOURS SHEETMETAL TO REPAIR PER SRM. UPDATED FAULT T3F18E003E27G TO EDIT THE FAULT DEADLINE FROM 60 DAYS TO 120 DAYS. PER EO 88831-REQ3. THIS CLEARS DEFER IAW EO-88831-REQ4 STEP 2.SDR IPXA2025022601346Floor Panel · damagedFOUND DAMAGE ON PANEL 194BR. INST€™D NEW PANEL, AMM 20 11 00.SDR IPXA2025022601354Floor Panel · damagedFOUND DAMAGE ON PANEL 194DR. INSTALLED NEW PANEL 194D, REF SRM 51-40-02. THIS CLEARS DEFERRAL.SDR SWAA2023122125362Floor Panel · pulledFWD FLOOR PANEL 222BF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FLOORBOARD 222BF UPPER SKIN HAS BEEN REPAIRED IAW SRM 53-00-50-2R-1.<BR><BR>ATTACHED CURE SHEETS TO THIS FAULT.;[02] VERIFIED FLOOR PANEL 222BF HAS BEEN REPAIRED IAW SRM 53-00-50-2R-1.;[03] WORSDR SWAA2023122125365Floor Panel · pulledFWD FLOOR PANEL 222DF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 222DF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] PANEL REPLACED. JOB SDR SWAA2023122125366Floor Panel · pulledFWD FLOOR PANEL 232BF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO EXCESSIVE DAMAGE FWD FLOOR PANEL 232BF WAS REPLACED WITH A NEW SERVICEABLE PART IAW SRM 51-10-02-0G-0 PAR 9.A (1).;[02] VERIFIED CORRECTIVE ACTION 1 AND THE MEASUREMENT TABLE.
Back to JASC 5321