JASC 5321
Service difficulty reports · 49,350
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA202301109754Floor Support · elongatedAIRCRAFT IN BASE MAINTENANCE: ELONGATED FASTENER HOLES IN MAIN CABIN FLOOR SUPPORT LOCATED AT BS 967 AND RBL 16. REPLACED FLOOR SUPPORT PER SRM 51-40-05 AND DWG 140A9870.SDR AALA202301104882Floor Support · elongatedAIRCRAFT IN BASE MAINTENANCE: ELONGATED FASTENER HOLES IN MAIN CABIN FLOOR SUPPORT LOCATED AT BS 986 AND BL 0. REPLACED FLOOR SUPPORT PER SRM 51-40-05 AND DWG 1475700.SDR ASAA2022122841320Floor Panel · damagedFLOOR PNL 221BF DAMAGED IN AFT CORNER. GROUNDED - YES. COMPLETED REPAIR ON FLOOR PNL 221BF DAMAGED ON AFT CORNER IAW B737-900ER SRM 53-00-50-2R-0.SDR FDEA202212283030Floor Panel · dentedMAIN CABIN - FLOOR PANEL 252MTF HAS DAMAGED INSERTS REMOVED AND REPLACED 25 INSERTS AND EVALUATED AND REPAIRED ADDITIONAL DAMAGE TO FLOOR PANEL 252MTF IAW B757 SRM 53-00-50-2R, FIG. 201, REPAIR 2, SHEET 1.SDR SWAA2023013085367Floor Panel · brokenBROKEN FLOOR PANEL 221BF AT FWD GALLEY AREA (1 EA) 2022-691934<[01] REPLACED FLOOR PANEL 221BF AT FWD GALLEY AREA (1 EA) IAW B737-700 AMM-53-21-00-400-801 3.A THRU 3.F (14);[02] CORRECTED STEP 1. REPLACED FLOOR PANEL 221BF AT FWD GALLEY AREA (1 EA) IAW B737-70SDR AALA202301181433Floor Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: AFT CARGO FLOOR PANEL AT STA 727D+5 TO 727I+5 HAS SURFACE CORROSION. FABRICATED AFT PIT FLOOR PANEL AND REPLACED CORRODED PANEL.SDR FDEA202212232999Floorboard · damagedZONE 220 FLOORBOARD 221MBF IS DAMAGED. FABRICATED NEW BOARD 11861182-16, 221MBF FROM TRAVELER T22/1651611 IAW DWG SRZ-25- 005 REV R. MAJOR REPAIRSDR FDEA202212222997Floor Panel · damagedMAIN CARGO DECK FLOORBOARD TAGGED AS 261FF HAS SEVERAL DAMAGED INSERTS. PANEL IS LOCATED IN THE L-3 DOORWAY. FABRICATED MAIN CARGO FLOOR PANEL 261FF IAW DWG SRZ-25-005SDR FDEA202212222989Floor Panel · delaminatedMAIN CABIN - FLOOR PANEL 252MUF HAS DAMAGED INSERT EVALUATED PANEL 252MUF AND REPAIRED DAMAGED AREA IAW B757 SRM 53-00-50-2R AND 53-00- 50-1ASDR FDEA202212222988Floor Panel · delaminatedMAIN CABIN - FLOOR PANEL 231MKF IS DAMAGED EVALUATED DAMAGE TO PANEL 231MKF AND FOUND 1EA PUNCTURE, REPAIRED PANEL IAW B757 SRM 53-00-50-1A AND SRM 53-00-50-2RSDR FDEA202212222987Floor Panel · delaminatedCOURIER AREA - FLOOR PANEL 221AF IS DELAMINATED FABRICATED NEW FLOOR PANEL 221AF IAW SRZ 25-005 REV: RSDR SWAA2023020784261Floor Panel · delaminatedDELAMINATED FLOOR PANEL 241CF AT CENTER SECTION 2022-697281<[01] TOOL USED: CALIPER: P/N: 500-752-20 ; S/N: B21038255 ; DUE DATE: 14-SEP-23.;[02] TOOL USED: HOT BONDER P/N: HCS9000B S/N: 15092096 DUE DATE: 16-JAN-23.;[03] TOOL USED: SCALE P/N: SPX621 S/N: 8340SDR SWAA2023020784265Floor Panel · delaminatedDELAMINATED FLOOR PANEL 242VF AT AFT GALLEY AREA 2022-697308<[01] TOOL USED: CALIPER: P/N: 500-464 ; S/N: B17030933 ; DUE DATE: 17-OCT-23.;[02] TOOL USED: HOT BONDER P/N: HCS9000B S/N: 15092096 DUE DATE: 16-JAN-23.;[03] TOOL USED: SCALE P/N: SPX621 S/N: 834022SDR SWAA2023020784269Floor Panel · delaminatedDELAMINATED FLOOR PANEL 241ADF AT AFT GALLEY AND LAV 2022-697306<[01] TOOL USED: CALIPER: P/N: 500-752-20 ; S/N: B21038255 ; DUE DATE: 14-SEP-23;[02] CORRECTIVE STEP 1 TOOL USED: CALIPER: P/N: 500-197-30 ; S/N: A21043164; DUE DATE: 25-SEP-23.;[03] TOOL USED: HSDR SWAA2023020784272Floor Panel · delaminatedDELAMINATED FLOOR PANEL 241AAF AT AFT GALLEY AREA 2022-697303<[01] TOOL USED: CALIPER: P/N: 500-752-20 ; S/N: B21038255 ; DUE DATE: 14-SEP-23.;[02] TOOL USED: HOT BONDER P/N: HCS9000B S/N: 15092096 DUE DATE: 16-JAN-23.;[03] TOOL USED= SCALE P/N: 91847; S/N: AESDR SWAA2023020784274Floor Panel · brokenBROKEN FLOOR PANEL 241XF AT AFT GALLEY AREA 2022-697312<[01] TOOL USED: CALIPER: P/N: 500-752-20 ; S/N: B21038255 ; DUE DATE: 14-SEP-23.;[02] TOOL USED: HOT BONDER P/N: HCS9000B S/N: 15092096 DUE DATE: 16-JAN-23.;[03] TOOL USED: SCALE P/N: SPX621 S/N: 83402254SDR SWAA2023012384313Floor Panel · delaminatedFLOOR PANEL 231ZF HAS AREAS OF DELAMINATION. DUE TO THE EXTENT OF THE DAMAGE TO THE FLOOR PANEL; DECIDED TO FABRICATE A NEW FLOOR PANEL, WORK PERFORMED IAW SRM 53-00-50-2R-0 PARAGRAPH 4.A.(2), FIGURE 204 & DRAWING 144A5810 SHEET 160, BAC5085 SECTION 8.4.2.SDR SWAA2023012384309Floor Panel · delaminatedFLOOR PANEL 242AF HAS AREAS OF DELAMINATION. DUE TO THE EXTENT OF THE DAMAGE, DECIDED TO FABRICATE A NEW FLOOR PANEL. WORK WAS PERFORMED IAW SRM 53-00-50-2R-0 PARAGRAPH 4.A.(2) AND TABLE 204 AND DRAWING 144A5810 SHEET 189.SDR SWAA2023012384314Floor Panel · delaminatedFLOOR PANEL 241FF HAS AREAS OF DELAMINATION. DAMAGE EXCEEDS ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PAR.4 B. DUE TO EXTENT OF DAMAGE NEW FLOORBOARD WILL BE FABRICATED IAW SRM 53-00-50-2R-0 PAR.1 A FABRICATED NEW FLOORBOARD, LOCATED & DRILLED HOLES IAW DWG SDR SWAA2023012384288Floor Panel · brokenBROKEN FLOOR PANEL 221BF LATERAL EDGE AT FWD GALLEY AREA 2022-700903<[01] REPLACED FLOOR PANEL 221BF LATERAL EDGE AT FWD GALLEY AREA I.A.W B737-700 AMM 53-21-00-400-801 STEP 3.(11) TO (14);[02] CORRECTED STEP 1<BR>REPLACED FLOOR PANEL 221BF AT FWD GALLEY AREA SDR SWAA2023012084281Floor Panel · crackedCRACKED FLOOR PANEL 221EF AT AT FWD GALLEY AREA. REPAIRED FLOOR PANEL 221EF AT AT FWD GALLEY AREA IAW SRM 53-00-50-2R-1 REPAIR 1.SDR SWAA2023011984322Floor Panel · delaminatedFLOOR PANEL 221DF HAS AREAS OF DELAMINATION. REMOVED DAMAGE AND CLEANED REPAIR AREA. FABRICATED REPAIR PLIES. INSTALLED REPAIR PLIES IAW SRM 53-00-50-2R-1; PARA'S 3.K.(1) AND 3.L.(1). REPLACED ALL REMOVED INSERTS IAW DRAWING 141A5810, SHEET 59, AND SRM 5SDR FDEA202212212981Floor Panel · delaminatedMAIN DECK FLOOR PANEL 291DF HAS DAMAGED/CORRODED INSERTS AFTER CLEANING FOUND PANEL DELAMINATED. FABRICATED NEW PANEL REF FEDEX DWG SRZ- 25-005SDR FDEA202212212983Floor Panel · delaminatedCOURIER AREA - FLOOR PANEL 222AF IS DELAMINATED FABRICATED NEW FLOOR PANEL 222AF IAW FEDEX SRZ 25-005 REV: R AND GMM 07-0-1001.SDR FDEA202212212982Floor Panel · delaminatedCOURIER AREA - FLOOR PANEL 222BF IS DELAMINATED FABRICATED NEW FLOOR PANEL 222BF IAW FEDEX SRZ 25-005 REV: R AND GMM: 07-0-1001SDR DALA2022122108269Floor Support · corrodedCORROSION ON FLOOR SUPPORT STA Y=218 - X=0 (CPAX)(W1). SUMMARY OF NRC 00363: CORROSION LEVEL 2. FLOOR SUPPORT STA Y=218 - X=0 WAS REPLACED PER B717-200 SRM 51-41-02-0G. (LP #2547442)SDR DALA2022122108268Floor Support · corrodedCORROSION ON FLOOR SUPPORT STA Y=200 BTW X=5 AND X=-5 (CPAX)(W1). SUMMARY OF NRC 00335: CORROSION LEVEL 2. FLOOR SUPPORT STA Y=200 BTW X=5 AND X=-5 WAS FABRICATED AND REPLACED PER DWNG 936534 REV BW AND B717-200 SRM 51-41-02-0G. (LP #2547431)SDR DALA2022122108267Support · corrodedCORROSION ON GALLEY SUPPORT STA Y=210 & STA Y=217 - X=-11 (CPAX)(W1). SUMMARY OF NRC 00361: CORROSION LEVEL 2. GALLEY SUPPORT STA Y=210 & STA Y=217 - X=-11 WERE REPLACED PER B717-200 SRM 51-41-02- 0G. (LP #2547311)SDR SWAA2023020783722Floor Panel · brokenBROKEN FLOOR PANEL 232SF AT CENTER SECTION 2022-697231<[01] TOOL USED: CALIPER P/N: 500-197-30 S/N: A21043164 DUE DATE: 25/SEP/23.;[02] TOOL USED: HOT BONDER P/N: HCS9000B S/N: 15092096 DUE DATE: 16-JAN-23.;[03] TOOL USED: SCALE P/N: SPX621 S/N: 8340225441 DUESDR SWAA2023011983817Floor Panel · brokenFLOOR PANEL 221BF HAS A BROKEN FLANGE OUTBD AFT EDGE. REMOVED AN APPROX. 6'X0.9' AREA OF DAMGED FULL DEPTH PANEL LOCATED AT THE OUTBOARD AFT CORNER WITH NO DISBOND OR CONTAMINATION NOTED IAW SRM 53-00-50-2R-6, PARAGRAPH 3.A, & C-E. REMOVED INSERTS IAW SRM 53SDR SWAA2023011883752Floor Panel · corrodedCORROSION FLOOR PANEL 140CF AT AFT CARGO COMPARTMENT. REPLACED FLOOR PANEL 140CF AT AFT CARGO COMPARTMENT IAW DWG 453A2610 REV. E. AND SRM 51-10-02; SRM 51-40-02.SDR SWAA2023011883753Floor Panel · corrodedCORROSION FLOOR PANEL 120BF AT FWD CARGO COMPARTMENT. REPLACED THE FLOOR PANEL 120BF AT FWD CARGO COMPARTMENT IAW DWG 453A1610 REV. C. AND SRM 51-10-02; SRM 51-40-02.SDR SWAA2023011183973Floor Panel · delaminatedPASSENGER CABIN FLOOR PANEL 241AF IS DELAMINATED ON UPPER SURFACE.<[01] DUE TO THE EXTENT OF DAMAGE; FABRICATED NEW PASSENGER CABIN FLOOR PANEL 241AF USING BMS 4-17TY6 LOT#1496139-1; INSTALLED INSERTS USING BMS 5-107 LOT#1507022-1; CURED USING THERMOMETER ID:ASDR SWAA2023011183974Floor Panel · delaminatedPASSENGER CABIN FLOOR PANEL 231XF WAS DELAMINATED ON UPPER SURFACE. REMOVED THE FLOOR PANEL IAW AMM 53-21-00-000-801. DAMAGE EXCEEDS ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PAR.4 F. A NEW FLOOR PANEL FABRICATED IAW SRM 53-00-50-2R-0 PAR.1 A. INSTALSDR DALA2022122008237Floor Support · corrodedSECONDARY NRC, IN REF NRC 00364: AFTER REMOVAL PARTS TO ATTEND DISCREPANCY, CORROSION ON FLOOR SUPPORT STA Y=200 AND X=-55 WAS FOUND AT PASSENGER CABIN FLOOR AREA. SUMMARY OF NRC 00462: CORROSION LEVEL 2. FLOOR SUPPORT STA Y=200 AND X=-55 WAS REPLACED PER B717SDR SWAA2023011983393Floor Panel · delaminatedFLOOR PANEL 241ABF HAD AREAS OF DELAMINATION. DELAMINATION IS OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1, PAR 4 F. DAMAGE WAS REPAIRABLE IAW SRM 53-00-50-2R-1. REMOVED LOSE PIECES OF CORE & CLEANED THE REPAIR AREA IAW SRM 53-00-50-2R-1, PARA 3,C-3. E. SDR SWAA2023011984305Floor Panel · delaminatedINSPECTED FLOOR PANEL 222BF FOUND AREAS OF DELAMINATION. REMOVED ALL DAMAGE NOTED AND CLEANED REPAIR AREAS. APPLIED POTTING TO EXPOSED CORE IAW SRM 53-00-50-2R-1, PARA 3G. SANDED POTTING FLUSH WITH INITIAL SURFACE, CLEANED REPAIR AREA AND FABRICATED REPAISDR SWAA2023011884179Floor Panel · delaminatedINSPECTED PANEL 222DF FOUND AREAS OF DELAMINATION. AREA OF DELAMINATION NEAR AFT LT TOOLSIDE CORNER IS OUT OF LIMITS IAW SRM 53-00-50-1A-1 PAR. 4. F. DELAMINATION IS REPAIRABLE IAW SRM 53-00-50-2R-1. REMOVED INSERTS. REMOVED DAMAGED PLIES AND CLEANED REPASDR DALA2022122008232Floor Support · corroded(LOG 2545343) DURING INSPECTION FOUND CORROSION ON FLOOR SUPPORTS 2(EAS) BTW B STA 947.5 TO BSTA 967 LBL 25 AND LBL 50. FLOOR SUPPORTS 2(EAS) BTW BSTA 947.5 TO BSTA 967 LBL 25 AND LBL 50 WERE REPLACED PER B737-900ER SRM 51-40-02-0G.SDR SWAA2023020682921Floor Panel · corrodedCORROSION FLOOR PANEL 221BF ON SLEEVES AT FWD GALLEY AREA 2022-697092<[01] FLOOR PANEL 221BF WAS REPLACED AS PER JOB CARD TTG8Q00GQW39AND DWG 141A5810 REV. J;[02] FLOOR PANEL 221BF WAS REPLACED AS PER JOB CARD TTG8Q00GQW39AND DWG 141A5810 REV. JSDR SWAA2023020682923Floor Panel · crackedCRACK FLOOR PANEL 221BF AT AT FWD GALLEY AREA 2022-697093<[01] REPLACED FLOOR PANEL 221BF AT FWD GALLEY AREA IAW AMM 53-21-00-400-801 AND DWG 141A5810 REV. J<BR>AND INSTALATION WILL BE ACORDING WITH ACO TTG8Q0038RHE.;[02] REPLACED FLOOR PANEL 221BF AT FWD GALLSDR SWAA2023020682905Floor Panel · elongatedELONGATED HOLE FLOOR PANEL 120AF AT FWD CARGO COMPARTMENT 2022-697108<[01] FABRICATED NEW FLOOR PANEL 120AF AT FWD CARGO COMPARTMENT IAW B737-700 AMM 25-52-01-201-801 AND DRAWING 453A1610 SHEET 9 REV F. MATERIAL USED: ALUMINUM SHEET P/N: 2024T3 0.071? P.O: 202SDR FDEA202212172940Floor Panel · delaminatedCOURIER AREA - FLOOR PANEL 221MBF IS DELAMINATED FABRICATED NEW FLOOR PANEL 221MBF IAW FEDEX DWG SRZ-25-005 REV R.SDR FDEA202212172939Floor Panel · delaminatedCOURIER AREA - FLOOR PANEL 222MDF IS DELAMINATED FABRICATED NEW FLOOR PANEL 222MDF IAW FEDEX DWG SRZ-25-005 REV RSDR FDEA202212172938Floor Panel · delaminatedCOURIER AREA - FLOOR PANEL 222MBF IS DELAMINATED FABRICATED NEW FLOOR PANEL 222MBF IAW FEDEX DWG SRZ-25-005 REV R.SDR FDEA202212172937Floor Panel · delaminatedCOURIER AREA - FLOOR PANEL 221MAF IS DELAMINATED FABRICATED NEW FLOOR PANEL 221MAF IAW DWG SRZ-25-005 REV R.SDR FDEA202212172936Floor Panel · delaminatedCOURIER AREA - FLOOR PANEL 222MAF IS DELAMINATED FABRICATED NEW FLOOR PANEL 222MAF IAW FEDEX DWG SRZ-25-005 REV RSDR FDEA202212172935Floor Panel · delaminatedCOURIER AREA - FLOOR PANEL 222MEF DELAMINATED. FABRICATED NEW FLOOR PANEL 222MEF IAW FEDEX DWG SRZ-25-005 REV R.SDR SWAA2023013082418Floor Panel · corrodedCORROSION FLOOR PANEL 140BF AT AFT CARGO COMPARTMENT 2022-691872<[01] TOOL USED: ULTRASONIC GAGE: P/N: 45MG; S/N: 221861811; DUE DATE: 08-NOV-23;[02] EVALUATED REWORK AREA LOCATED ON FLOOR PANEL 140BF AT AFT CARGO COMPARTMENT AND FOUND WITHIN LIMITS IAW B737-7SDR AALA202212279158Floor Skin · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION AT AFT WET AREA FLOOR STRUCTURE UPPER SKIN STA 990 AND RIGHT BUTT LINE 33. REMOVED AND REPLACED FLOOR STRUCTURE UPPER SKIN
Back to JASC 5321