JASC 5321
Service difficulty reports · 49,350
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2022032301912None · noneSHIP 3270 BROKEN FLOOR BEAM -Y1292 TEFLON BUSHING AT LEVEL OF FR35 IN PASSENGER CABIN. CORRECTIVE ACTION: REPLACED TEFLON BUSHING LOCATED FLOOR BEAM -Y1292 AT LEVEL AT LEVEL OF FR35 IN PASSENGER CABIN (1EA) AS PER A320 SRM 51-42-11. (2162062)SDR DALA2022032301903None · noneSHIP 3270 CORROSION SHEAR PLATE STR 23L FR69 TO FR70 AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED SHEAR PLATE PER A320 SRM 51-42-11 AND 51-72-11. (2162104)SDR DALA2022032301902None · noneSHIP 3270 CORROSION FLOOR STRUCTURE WEB LOCATED BETWEEN FR12 TO FR16 AND STR 23R AT FWD GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR STRUCTURE WEB PER A320 SRM 51-42-11 AND 51-72-11. (2162095)SDR DALA2022032301901None · noneSHIP 3270 CORROSION WEB LOCATED BETWEEN FR20 TO FR21 AND STR 23R FWD GALLEY AREA. CORRECTIVE ACTION: REPLACED WEB PER A320 SRM 51-72-11. (2162094)SDR DALA2022032301892None · noneSHIP 3234 CORROSION FLOOR STRUCTURE LOC -Y765 BTW FR16 TO FR20 IN PASSENGER CABIN. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A320 SRM 51-42-11 AND 51-72-11. (2161932)SDR SWAA2022042085159Floorbeam · corrodedCORROSION ON FLOOR BEAM UPPER SURFACE AT B.S. 986.5; L.B.L. 35 - L.B.L.45; W.L. 208.1. / [01] SRM 53-70-51-1A-1 ALLOWABLE DAMAGE 1 IS APPLICABLE TO THIS A/C;[02] REMOVED SEVERAL AREAS OF CORROSION ON FLOOR BEAM UPPER SURFACE AT BS 986.5 FROM LBL35-LBL45; WL 20SDR SWAA2022041985196Floor Panel · pulledFLOOR PANEL 242AF UPPER SURFACE HAS MULTIPLE COMPOSITE STRANDS PULLED IN MULTIPLE AREAS. / [01] IDENTIFIED PANEL 242 AF IAW DRAWING 144A5810 SHEET 132. DUE TO THE EXTENT OF THE DAMAGE; DECIDED TO FABRICATE A NEW PANEL USING BMS4-17 TYPE VI LOT NUMBER 1482614-1SDR R61A2022040500239Seat Track · corrodedFWD FUSELAGE FLOOR CORRODED AT I/B R/H SEAT TRACK FR 18-19. R&R IAW EMB 175 SRM 51-41-01, 51-41-02, 51-43-04 AND 51-43-02.SDR DALA2022031801803None · noneSHIP 3270 CORROSION FLOOR BEAM +Y765 AT FR67 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM AND FASTENERS PER A320 SRM 51-72-11 AND 51-42-11. (2160981)SDR DALA2022031801802None · noneSHIP 3269 CORROSION SHEAR TIE LOCATED FR31 BTW STR 39R TO STR 40R IN FWD CARGO COMPARTMENT. CORRECTIVE ACTION: REPLACED SHEAR TIE PER A320 SRM 51-72-11. (2160960)SDR DALA2022031801801None · noneSHIP 3269 CORROSION SHEAR TIE LOCATED FR29 BTW STR 43R TO STR 43L IN FWD CARGO COMPARTMENT. CORRECTIVE ACTION: REPLACED SHEAR TIE PER A320 SRM 51-72-11 AND 51-42-11. (2160957)SDR DALA2022031801800None · noneSHIP 3269 CORROSION LOWER SILL CENTER FITTING LOC BTW FR16 TO FR20 LH SIDE IN PASSENGER CABIN. CORRECTIVE ACTION: REPLACED LOWER SILL CENTER FITTING PER A320 SRM 51-72-11. (2160947)SDR DALA2022031801799None · noneSHIP 3269 CORROSION LOWER SILL LOC FR16 TO FR20 RH SIDE IN PASSENGER CABIN. CORRECTIVE ACTION: REPLACED LOWER SILL AND FASTENERS PER A320 SRM 51-72-11. (2160760)SDR DALA2022031801798None · noneSHIP 3269 CORROSION LOWER SILL CORNER FR20 LH SIDE IN PASSENGER CABIN. CORRECTIVE ACTION: REPLACED CORNER FITTING PER A320 SRM 51-72-11. (2160747)SDR DALA2022031801797None · noneSHIP 3225 CORROSION FLOOR BEAM -Y1292 LOC. BTW FR12 AND FR24 IN PASSENGER CABIN. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A320 SRM 51-42-11. (2160738)SDR SWAA2022040784644Floor Panel · corrodedDOT#43-186 AFT CARGO COMPARTMENT FLOOR PANEL 140DF CORRODED AROUND EDGES / [01] EVALUATED ALLOWABLE LIMITS: TOTAL ACCUMULATED DAMAGE LENGTH IS 20 INCHES MORE FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-1;[02] VERIFIED MATERIAL ID FOR NEW FLOOR PANEL IS 2024 T3 .07SDR SWAA2022040784639Floor Panel · corrodedDOT#44-186 AFT CARGO COMPARTMENT FLOOR PANEL 140CF CORRODED AROUND EDGES / [01] EVALUATED CORROSION ON AFT CARGO FLOOR PANEL 140CF CORROSION WAS FOUND TO BE OUT LIMITS EXCEEDS 20' IAW B737 SRM 53-00-53-1A-1;[02] MATERIAL ID FOR FLOOR PANEL 140CF IS 2024 T-3 .0SDR SWAA2022040784640Floor Panel · corrodedDOT#45-186 AFT CARGO COMPARTMENT FLOOR PANEL 140BF CORRODED AROUND EDGES / [01] EVALUATED PANEL 140BF FOUND THE TOTAL ACCUMULATED CORROSION EXCEEDS THE MAXIMUM 20'. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1. WORK PERFORMED BY BERNARD BEMKE 27266;[02] VERSDR SWAA2022040784645Floor Panel · corrodedDOT#46-186 AFT CARGO COMPARTMENT FLOOR PANEL 140AF CORRODED AROUND EDGES / [01] VERLFED MATERIAL LOSS CORROSION IS MORE THEN 20 INCHES MAXIMUM IS 20 INCHES IS OUT OF LIMITS I/A/W SRM 53-00-53-1A-1;[02] VERIFIED NEW MATERIAL FOR FLOOR PANEL 140AF FOR AFT CARGO SDR SWAA2022040784641Floor Panel · corrodedDOT#47-186 AFT CARGO COMPARTMENT FLOOR PANEL 140EF CORRODED AROUND EDGES / [01] EVALUATED PANEL 140EF FOUND THE TOTAL ACCUMULATED CORROSION EXCEEDS THE MAXIMUM 20'. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1. WORK PERFORMED BY BERNARD BEMKE 27266;[02] VERSDR SWAA2022041283724Floor Panel · corrodedDOT 050-023 FORWARD CARGO COMPARTMENT FLOOR PANEL 120AF IS CORRODED / [01] EVALUATED CORROSION; FOUND CORROSION EXCEEDS 20' FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-1;[02] VERIFIED PN: 2024-T3-071 A-TAG: A118124 IAW SRM 25-52-01-201-801;[03] VERIFIED STEPS 1 ANSDR SWAA2022041283726Floor Panel · corrodedDOT 050-024 FORWARD CARGO COMPARTMENT FLOOR PANEL 120CF IS CORRODED / [01] FOUND CARGO FLOOR PANEL 120CF TO BE OUT OF LIMITS; MORE THAN 20' IN LENGTH OF ACCUMULATED DAMAGE IAW SRM 53-00-53-1A-1 PARA 5A FIG 102.;[02] VERIFIED MATERIAL FOR NEW FLOOR PANEL 120CF SDR SWAA2022041283720Floor Panel · corrodedDOT 050-026 FORWARD CARGO COMPARTMENT FLOOR PANEL 120DF IS CORRODED / [01] DAMAGE EXCEEDED 20' MAX ALLOWABLE LIMITS AND FOUND TO BE OUT OF LIMITS IAW B-737 SRM 53-00-53-1A-1 STEP 5 A B FIG. 102;[02] MATERIAL VERIFIED AS 0.071' 2024-T3 IAW B-737 SRM 25-52-01-83SDR SWAA2022040783725Floor Panel · corrodedDOT 050-024 FORWARD CARGO COMPARTMENT FLOOR PANEL 120BF IS CORRODED / [01] CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1 PARA 5A AND FIG 102.;[02] VERIFIED MATERIAL FOR NEW FLOOR PANEL 120BF TO BE PN: 2024-T3-071 ATAG# A118124 IAW AMM 25-52-01-201-SDR FDEA202203150695Plate · crackedAVIONICS COMP'T DOOR AFT EDGE PANEL SUPPORT FRAME CRACK ABOUT0.2". REPLACED THE PLATE BENT WITH NEW ONE I.A.W A300-600F SRM 51-72-10-001, PAGE2SDR DALA2022031601722None · noneSHIP 3225 CRACK INTERNAL STRUCTURE BTW FR54/55, STR 38LH IN AFT CARGO COMPARTMENT. CORRECTIVE ACTION: REPLACED WEB PER A320 SRM 51-72-11. (2158125)SDR DALA2022031601721None · noneSHIP 3225 CRACKED PROFILE LOCATED FR54 TO FR59, STR 35LH IN AFT CARGO COMPARTMENT. CORRECTIVE ACTION: REPLACED PROFILE PER A320 SRM 51-72-11. (2158107)SDR DALA2022031601719None · noneSHIP 3270 CORROSION FLOOR BEAM +Y765 AT FR16 AT FWD GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A320 SRM 51-72-11. (2158086)SDR SWAA2022041883730Floor Support · looseMAIN CABIN CENTER WING FLOOR SUPPORT BREAK UPPER LAYER LOOSE AT STA 540 BL-0 TO LBL-24 / [01] REMOVED AND REPLACED UPPER LAYER AT MAIN CABIN CENTER WING FLOOR SUPPORT BRAKE PLATE STA 540 BL-0 TO LBL-24 AS REF. B737-700 SRM 51-40-02-0G-0;[02] VERIFIEDSDR SWAA2022032983903Floor Panel · pulledA22-08; PASSENGER CABIN FLOOR PANEL 241CF; UPPER SURFACE; PULLED FACE SHEET PLIES. / [01] EVALUATED AND FOUND DAMAGE TO BE REPAIRABLE IAW SRM 53-00-50-2R-0 REPAIR GENERAL TABLE 201 REPAIR 1<BR>CLEANED AND PREPPED FOR REPAIR IAW SRM 53-00-50-2R-1 PARAGRAPH 3A;CSDR SWAA2022032983892Floor Panel · pulledA22-07; PASSENGER CABIN FLOOR PANEL 241BF; UPPER SURFACE; PULLED FACE SHEET PLIES. / [01] EVALUATED AND FOUND DAMAGE TO UPPER SURFACE TO BE REPAIRABLE IAW SRM 53-00-50-2R-0 REPAIR GENERAL TABLE 201 REPAIR 1<BR>CLEANED AND PREPPED UPPER SURFACE IAW SRM 53-00-50SDR SWAA2022032983902Floor Panel · pulledA22-06; PASSENGER CABIN FLOOR PANEL 231ZF; UPPER SURFACE; PULLED FACE SHEET PLIES. / [01] EVALUATED AND FOUND MISSING FIBER ON UPPER SURFACE AS MARKED. NO DAMAGE TO COMPOSITE SUBSTRATE. FOUND TO BE REPAIRABLE IAW SRM 53-00-50-2R-1.<BR><BR>CLEANED AND PREPPED ISDR SWAA2022032983891Floor Panel · pulledA22-05; PASSENGER CABIN FLOOR PANEL 241AF; UPPER SURFACE; PULLED FACE SHEET PLIES. / [01] EVALUATED DAMAGE; UPPER SURFACE DAMAGE REPAIRABLE IAW B737 SRM 53-00-50-2R-1; TAP TEST GOOD; NO DELAMINATION.<BR><BR>CLEANED AND PREPPED REPAIR AREA IAW B737 SRM 53-00-50SDR SWAA2022032983901Floor Panel · pulledA22-04; PASSENGER CABIN FLOOR PANEL 231XF; UPPER SURFACE; PULLED FACE SHEET PLIES. / [01] EVALUATED AND FOUND MISSING FIBERS ON UPPER SURFACE. NO DAMAGE TO COMPOSITE SUBSTRATE. FOUND TO BE REPAIRABLE IAW SRM 53-00-50-2R-1.<BR><BR>CLEANED AND PREPPED IAW SRM 53SDR SWAA2022032983900Floor Panel · pulledA22-03; PASSENGER CABIN FLOOR PANEL 242F; UPPER SURFACE; PULLED FACE SHEET PLIES. / [01] EVALUATED DAMAGE; UPPER SURFACE IS REPAIRABLE IAW B737 SRM 53-00-50-2R-1. TAP TEST GOOD; NO DELAMINATION NOTED. <BR><BR>CLEANED AND PREPPED REPAIR AREA IAW B737 SRM 53-00-SDR SWAA2022032983899Floor Panel · pulledA22-02; PASSENGER CABIN FLOOR PANEL 242BF; UPPER SURFACE; PULLED FACE SHEET PLIES. / [01] EVALUATED AND FOUND MISSING PLIES ON UPPER SURFACE. NO DAMAGE TO COMPOSITE SUBSTRATE. FOUND TO BE REPAIRABLE IAW SRM 53-00-50-2R-1.<BR><BR>CLEANED AND PREPPED IAW SRM 53-SDR FDEA202203140504Floor Panel · crackedMAIN CABIN FLOOR PANEL 241KFF HAS PUNCTURE DAMAGE 2 PLACES, STA 829, LBL 80 REPAIRED MAIN CABIN FLOOR PANEL 2EA PLACES, STA 829 AND LBL 80 IAW B767 SRM 53-00-50- 2R, PARA. 4.D.SDR FDEA202203140503Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 242GFF HAS PUNCTURE DAMAGE, STA 880, RBL 57 REPAIRED MAIN CABIN FLOOR PANEL, STA 880 AND RBL 57 IAW B767 SRM 53-00-50-2R, PARA. 4.C.SDR FDEA202203140502Floor Panel · crackedMAIN CABIN FLOOR PANEL 241ZFF IS DENTED/CRACKED 2 PLACES, STA 1015, LBL 68 REPAIRED MAIN CABIN FLOOR PANEL 2EA PLACES, STA 1015 AND LBL 68 IAW B767 SRM 53-00-50- 2R, PARA. 4.D.SDR FDEA202203140499None · noneFORWARD CABIN - FLOOR PANEL #241GF FOUND DELAMINATED AT STA STATION 795 TO STATION 899. FORWARD CABIN FLOOR PANEL #241GF AT STATION 795 TO STATION 899 REMOVED AND REPLACED AS PER AMM 53-21-04. FLOOR PANEL FABRICATED AS PER FEDEX DRAWING SRZ-25- 005 REVISSDR DALA2022031501697None · noneSHIP 3101 - CORROSION FLOOR BEAM -Y1162.5 AT LEVEL OF FR 68 AT AFT GALLEY. CORRECTIVE ACTION: REPLACED FLOOR BEAM -Y1162.5 AND FASTENERS LOC. BTW FR68 AND FR69 AFT GALLEY AREA AS PER SRM A319 51-42.(2156850)SDR DALA2022031501696None · noneSHIP 3101 - CORROSION FLOOR BEAM LOC BTW -Y1292 AND -Y1162.5 AND BTW FR 66/67 AT AFT GALLEY. CORRECTIVE ACTION: REPLACED FLOOR BEAM -Y1292 AND FASTENERS LOC. BTW FR66 AND FR68 AFT GALLEY AREA AS PER SRM A319 51-42. (2156845)SDR DALA2022031501681None · noneSHIP 3270 CORROSION FLOOR BEAM -Y160 LOCATED BETWEEN FR68 TO FR70 AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A320 SRM 51-72-11. (2156811)SDR DALA2022031501680None · noneSHIP 3270 CORROSION FLOOR BEAM -Y160 AT FR68 AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A320 SRM 51-72-11. (2156809)SDR SWAA2022041883328Floor Panel · pulledAFT CABIN FLOOR PANEL 241ACF HAS PULLED THROUGH INSERTS / [01] IDENTIFIED FLOOR PANEL 241ACF IAW SRM 53-00-50-0I-1 FIG6. TABLE6. FOUND DAMAGE TO BE BEYOND ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA4.F. DAMAGE WILL BE REPAIRED IAW SRM 53-00-50-2R-1. REMOVED 2 SDR AALA202203250159Floor Panel · noneAIRCRAFT WAS NOT GROUNDED: FLOOR PANEL NEAR 2D AISLE SOFT + MAKING CRACKING SOUND WHEN STEPPING ON IT. **SUPPLEMENTAL REPORT FOR AALA202203150159: REMOVED FLOOR PANEL INSTALLED TAPE ON FLOOR PANEL PER AMM 53-21-00 AND RE-INSTALLED FLOOR PANEL ** (CLOSED)SDR SWAA2022031783453Floor Panel · damagedCABIN CENTER FLOOR AISLE PANEL POPPING AT SEAT ROW 7 / [01] REMOVED CABIN CENTER FLOOR AISLE PANEL AT SEAT ROW 7 PER AMM 53-21-00.;[02] INSTALLED NEW FLOORBOARD PER AMM 53-21-00-400-801SDR SWAA2022031783452Floor Panel · poppedCENTER FLOOR PANEL POPPING AT ROW 2 / [01] REMOVED PASSENGER CABIN CENTER FLOOR PANEL AT ROW 2. REF AMM 53-21-00;[02] REINSTALLED FLOORBOARD OVER AMM 53-21-00-400-801SDR AALA202203150159Floor Panel · noneAIRCRAFT WAS NOT GROUNDED: FLOOR PANEL NEAR 2D AISLE SOFT + MAKING CRACKING SOUND WHEN STEPPING ON IT. **SUPPLEMENTAL REPORT WILL BE SUBMITTED ** (OPEN)SDR DALA2022031401638None · noneSHIP 3225 CORROSION ANGLE WEB FLOOR STRUCTURE LOC AT LEVEL STR 23R BTW FR 20 AND FR 24 FWD GALLEY AREA. CORRECTIVE ACTION: REPLACED ANGLE WEB PER A320 SRM 51-42-11 AND 51-72-11. (2155435)
Back to JASC 5321