JASC 5321
Service difficulty reports · 49,369
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2021101221165Floor Panel · pulledFWD WET AREA FLOOR BOARD 221FF; UPPER SURFACE; AREAS OF COMPOSITE FACE SHEET PLIES PULLING; MRK'D. / REPAIRED UPPER SURFACE OF FLOOR PANEL 221FF IAW B737-800 SRM 53-00-50-2R-1 REPAIR 1 A57959 A13436SDR SWAA2021101221137Floor Panel · peelingPASSENGER CABIN FLOOR;PANEL 242D SEVERAL AREAS OF TOP SKIN PEELING / REPAIRED AREA'S ON UPPER SURFACE PULLED FIBERS ON PANEL 242D IAW B737-800 SRM 53-00-50-2R-1; SRM 53-00-50-2R-0SDR DALA2021092205689None · noneSHIP 649 INITIAL INSPECTION. TOOLS MARKS ON STABILIZER STRAP BTW STA. 1480 TO 1520, RBL 25 AT AFT CARGO COMPARTMENT CEILING AREA. CORRECTIVE ACTION: SUMMARY OF NRC 00633. STABILIZER STRAP BTW STA. 1480 TO 1520, RBL 25 WAS REPAIRED PER B757-200 SRM. (1955333)SDR AALA202109219552Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: AFT PASSENGER CABIN FLOOR PANEL 251WF DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-02-00-300-011 AND IRM 9701.SDR AALA202109218749Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: AFT PASSENGER CABIN FLOOR PANEL 261AG DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-02-00-300-011 AND IRM 9701.SDR DALA2021092105643None · noneSHIP 3250 CORROSION FLOOR BEAM +Y1292 AT FR16 AT FWD GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A320 SRM 51-42-11, AND 51-72-11. (1955240)SDR SWAA2021110119244Floor Panel · delaminatedDELAMINATED TOP LAYER ON FLOOR PANEL 222CF AT FWD GALLEY AREA ; 2021-431793 / [23] REPAIRED FLOOR PANEL 222CF AT FWD GALLEY AREA AS PER B737-700 SRM 53-00-50-2R-1 REPAIR 1.; [24] REPAIRED FLOOR PANEL 222CF AT FWD GALLEY AREA AS PER B737-700 SRM 53-00-50-2R-1 RSDR SWAA2021110119245Floor Panel · delaminatedDELAMINATED TOP LAYER ON FLOOR PANEL 221CF AT FWD GALLEY AREA ; 2021-431797 / [23] REPAIRED FLOOR PANEL 221CF AT FWD GALLEY AREA AS PER B737-700 SRM 53-00-50-2R-1 REPAIR 1.; [24] REPAIRED FLOOR PANEL 221CF AT FWD GALLEY AREA AS PER B737-700 SRM 53-00-50-2R-1 RSDR SWAA2021110119247Floor Panel · delaminatedDELAMINATED TOP LAYER ON FLOOR PANALE 221BF AT FWD GALLEY AREA ; 2021-431792 / [21] REPAIRED FLOOR PANEL 221BF AT FWD GALLEY AREA AS PER B737-700 SRM 53-00-50-2R-1 REPAIR 1.; [22] REPAIRED FLOOR PANEL 221BF AT FWD GALLEY AREA AS PER B737-700 SRM 53-00-50-2R-1 SDR SWAA2021110119248Floor Panel · delaminatedDELAMINATED TOP LAYER ON FLOOR PANEL 222DF AT FWD GALLEY AREA ; 2021-431794 / [21] REPAIRED FLOOR PANEL 222DF AT FWD GALLEY AREA AS PER B737-700 SRM 53-00-50-2R-1 REPAIR 1.; [22] REPAIRED FLOOR PANEL 222DF AT FWD GALLEY AREA AS PER B737-700 SRM 53-00-50-2R-1 RSDR SWAA2021110119249Floor Panel · delaminatedDELAMINATED TOP LAYER ON FLOOR PANEL 222BF AT FWD GALLEY AREA ; 2021-431795 / [21] REPAIRED FLOOR PANEL 222BF AT FWD GALLEY AREA AS PER B737-700 SRM 53-00-50-2R-1 REPAIR 1.; [22] REPAIRED FLOOR PANEL 222BF AT FWD GALLEY AREA AS PER B737-700 SRM 53-00-50-2R-1 RSDR SWAA2021110119250Floor Panel · delaminatedDELAMINATED TOP LAYER ON FLOOR PANEL 222AF AT FWD GALLEY AREA ; 2021-431796 / [21] REPAIRED FLOOR PANEL 222AF AT FWD GALLEY AREA AS PER B737-700 SRM 53-00-50-2R-1 REPAIR 1.; [22] REPAIRED FLOOR PANEL 222AF AT FWD GALLEY AREA AS PER B737-700 SRM 53-00-50-2R-1 RSDR SWAA2021102819251Floor Panel · delaminatedDELAMINATED TOP LAYER ON FLOOR PANEL 221DF AT FWD GALLEY AREA ; 2021-A431798 / [20] REPAIRED FLOOR PANEL 221DF AT FWD GALLEY AREA AS PER B737-700 SRM 53-00-50-2R-1 REPAIR 1.; [21] REPAIRED FLOOR PANEL 221DF AT FWD GALLEY AREA AS PER B737-700 SRM 53-00-50-2R-1 SDR AALA202110080026Floor Panel · damagedAIRCRAFT WAS GROUNDED: FLOOR PANELS SOFT AND DEFLECTING AT ROWS 2-5. **SUPPLEMENTAL REPORT: REPLACED FLOOR PANELS 231AF, 231DF (AALA202110081458), AND 231GF (AALA202110081676) WITH NEW IAW AMM 53-21-00 AND AARD 53-00-50-01.** (CLOSED)SDR AALA202110081458Floor Panel · damagedAIRCRAFT WAS GROUNDED: FLOOR PANELS SOFT AND DEFLECTING AT ROWS 2-5. **SUPPLEMENTAL REPORT: REPLACED FLOOR PANELS 231AF, 231DF (AALA202110081458), AND 231GF (AALA202110081676) WITH NEW IAW AMM 53-21-00 AND AARD 53-00-50-01.** (CLOSED)SDR AALA202110081676Floor Panel · damagedAIRCRAFT WAS GROUNDED: FLOOR PANELS SOFT AND DEFLECTING AT ROWS 2-5. **SUPPLEMENTAL REPORT: REPLACED FLOOR PANELS 231AF (AALA202109230026), 231DF (AALA202110081458), AND 231GF WITH NEW IAW AMM 53-21-00 AND AARD 53-00-50-01.** (CLOSED)SDR AALA202110050265Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: DELAMINATION OF MAIN CABIN FLOOR PANEL 231ZH. REPLACED FLOOR PANEL WITH NEW IAW AA A321 AMM 53-00-00.SDR AALA202109230026None · noneAIRCRAFT WAS NOT GROUNDED: FLOOR PANEL SOFT AND DEFLECTING AT ROWS 2-5. **SUPPLEMENTAL REPORT WILL BE SUBMITTED.** (OPEN)SDR SWAA2021092321110Floor Panel · delaminatedFLOOR PANEL 241D DELAMINATED / PREPARED DAMAGED AREA FOR REPAIR AND REPAIRED AT FLOOR PANEL 241D AS PER B737-800 SRM 53-00-50-2R-7 MATERIAL USED PO 1694548 AND PO 1714421SDR DALA2021092205688None · noneSHIP 649 CORROSION ON L2 PASSENGER DOOR LOWER SILL UPPER SURFACE AT PAX CABIN, IN REF NRC 0772. CORRECTIVE ACTION: SUMMARY OF NRC 00971. LOWER SILL WAS REPLACED PER B757-200 SRM. (1954373)SDR DALA2021092205686None · noneSHIP 6807 CORROSION ON SUPPORT CHANNEL BTW BSTA 1660 TO BSTA 1680 RBL 54 MAIN DECK. CORRECTIVE ACTION: SUMMARY OF NRC 00488,LEVEL CORROSION 2:SUPPORT CHANNEL WAS REPLACED PER B757-200 SRM. (1954086)SDR SWAA2021100420965Splice Strap · corrodedFLOOR BOARD SPLICE STRAP BS727D+6; WL156; LBL22 TO RBL22 FOUND TO BE CORRODED ON UPPER SURFACE ; / [01] FLOOR BOARD SPLICE STRAP BS767+6 WL156 LBL22 TO RBL22 FOUND TO BE CORRODED ON UPPER SURFACE. NO ALLOWABLE DAMAGE FOUND IN B737-700 SRM FOR THIS PART REPAIR SDR FDEA202109182358Floor Panel · damagedTHE #147CF KEEL BEAM FLOOR WAS FOUND SOFTEN AND CAUSE BY HYD FLUID CONTAMINATION FABRICATED FLOOR PANEL #147CF I.A.W FEDEX DWG SRZ-25-005 REV.RSDR DALA2021092105648None · noneSHIP 649 ON REF NRC 0336 CORROSION ON SIDE PLATE LH SIDE BTW STATIONS: 1322 TO 1324// 1340 TO 1344// 1346 TO 1348// 1357 TO 1360 AT AFT CARGO COMPARTMENT. CORRECTIVE ACTION:SUMMARY OF N.R.C. 00904. CORROSION LEVEL. 2. SIDE PLATE LH SIDE BTW STATIONS: 1322 TO 1SDR DALA2021092105636None · noneCORROSION ON JAMB BTW STA Y=370 TO Y=425 AT FWD CARGO COMPARTMENT JAMB AREA. SUMMARY OF NRC 00216: CORROSION LEVEL 2, SECTION OF JAMB BTW STA Y=370 TO Y=425 AT FWD CARGO COMPARTMENT WAS REPLACED PER B717 SRM 53-20-15-2R-6. (LP #1953156)SDR SWAA2021101319769Panel · crackedPANEL 191FL HAS SEVERAL CRACKED / PULLED THROUGH FASTENER ATTACH HOLES ; / [01] PART/MATERIAL IDENTIFIED PER SRM 53-30-70-0I-1 FIG 2 TABLE 2 ITEM 4 .<BR>DAMAGE EXCEEDS ALLOWABLE DAMAGE AS GIVEN IN SRM 53-30-70-1A-1 PARA 4 B .<BR>REPAIR TO BE PERFORMED IAW SRM SDR SWAA2021101320669Floor Panel · crackedPANEL 191FR HAS SEVERAL CRACKED & PULLED THROUGH FASTENER HOLES. EXCEED ALLOWABLE DAMAGE LIMITS IAW SRM 53-30-70-1A-1 PARAGRAPH 4.B(6). REMOVED DAMAGE AND UPSIZED HOLES. PREPPED AND CLEANED HOLES IAW SRM 51-70-04-2R-9 PARAGRAPH 4.A-C. APPLIED FIBERGLASS/RSDR SWAA2021101321115Panel · corrodedAFT CARGO COMP.PANEL 140CF CORRODED AROUND EDGE FASTNER HOLES / CORROSION EXCEEDED LIMITS IAW SRM 53-00-53-1A-1 FIG 102; VERIFIED CORRECT MATERIAL 2024-T3 .071' IAW SRM 53-60-53-01-1 A-TAG# A67408; FABRICATED NEW AFT CARGO FLOOR PANEL 140CF IAW AMM 25-52-01-20SDR SWAA2021101121182Floor Panel · damagedPASSENGER CABIN ; FORWARD WET AREA FLOOR BOARD 221DF; COMPOSITE DAMAGE FROM TORN OUT INCERT. / REPAIRED AND INSTALLED 10 EA INSERTS ON PASSENGER CABIN FWD WET AREA FLOORBOARD 221DF DAMAGE FROM TORN OUT INSERT UPPER AND LWR SURFACE IAW SRM 53-00-50-2R-1; AND SRSDR SWAA2021101121185Floor Panel · pulledPASSENGER CABIN; FORWARD WET AREA FLOORBOARD 222BF HAS PULLED FIBER DAMAGE TO TOP STRANDS / REPAIRED DAMAGE TO UPPER SURFACE FLOOR BOARD 222BF IAW SRM 53-00-50-2R-0 REPAIR GENERAL AND SRM 53-00-50-2R-1 REPAIR 1 TAP TEST GOODSDR SWAA2021101119020Floor Panel · pulledAFT CABIN WET AREA FLOOR BOARD 241AAF; UPPER SURFACE; AREA OF COMPOSITE FACE SHEET PLIES PULLING / REPAIRED PANEL 241AAF I/A/W BOEING 737-800 SRM 53-00-50-2R0 AND 53-00-50-2R-1SDR SWAA2021101120286Floor Panel · pulledPASSENGER CABIN; FORWARD WET AREA FLOORBOARD 222BF HAS PULLED FIBER DAMAGE TO TOP STRANDS /SDR SWAA2021100519843Floor Panel · delaminatedDELAMINATED TOP LAYER ON FLOOR PANEL 242UF AT AFT GALLEY AREA ; 2021-392990 / [18] REPAIRED FLOOR PANEL 242UF AT AFT GALLEY AREA AS PER B737-700 SRM 53-00-50-2R-1 REPAIR 1.RII INSPECTIONSDR SWAA2021100519842Floor Panel · delaminatedDELAMINATED TOP LAYER ON FLOOR PANEL 242VF AT AFT GALLEY AREA ; 2021-392986 / [17] REPAIRED FLOOR PANEL 242VF AT AFT GALLEY AREA AS PER B737-700 SRM 53-00-50-2R-1 REPAIR 1; [18] REPAIRED FLOOR PANEL 242VF AT AFT GALLEY AREA AS PER B737-700 SRM 53-00-50-2R-1 RESDR SWAA2021100520742Floor Panel · delaminatedDELAMINATED TOP LAYER ON FLOOR PANEL 242UF AT AFT GALLEY AREA ; 2021-392990 / [17] REPAIRED FLOOR PANEL 242UF AT AFT GALLEY AREA AS PER B737-700 SRM 53-00-50-2R-1 REPAIR 1.; [18] REPAIRED FLOOR PANEL 242UF AT AFT GALLEY AREA AS PER B737-700 SRM 53-00-50-2R-1 RSDR SWAA2021100520741Floor Panel · delaminatedDELAMINATED TOP LAYER ON FLOOR PANEL 242VF AT AFT GALLEY AREA ; 2021-392986 / [17] REPAIRED FLOOR PANEL 242VF AT AFT GALLEY AREA AS PER B737-700 SRM 53-00-50-2R-1 REPAIR 1; [18] REPAIRED FLOOR PANEL 242VF AT AFT GALLEY AREA AS PER B737-700 SRM 53-00-50-2R-1 RESDR DALA2021092005606None · noneSHIP 649 CORROSION ON LH SIDE PLATE BTW STA 1301 TO 1302 IN ORDER TO PERFORM NRC 335. CORRECTIVE ACTION: SUMMARY OF NRC 00883: LH SIDE PLATE BTW STA 1301 TO 1302 WAS REPAIRED PER B757-200 SRM. (1952262)SDR DALA2021092005605None · noneSHIP 6807 CORROSION ON SUPPORT CHANNEL BEAM BTW BSTA 1300 TO BSTA 1320 LBL 22 PAX CABIN. CORRECTIVE ACTION: SUMMARY OF NRC 00553: SUPPORT CHANNEL BEAM BTW BSTA 1300 TO BSTA 1320 LBL 22 WAS REPLACED PER B757-200 SRM. (1952245)SDR DALA2021092005602None · noneSHIP 649 CORROSION ON SIDE PLATE LH SIDE UPPER AND LOWER FACES BTW STA= 806 TO STA= 807 AT FWD CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00976: LH SIDE PLATE FROM STA 770 TO 810 AT FWD CARGO COMPARTMENT WAS REPAIRED PER B757-200 SRM. (1951234)SDR DALA2021092005601None · noneSHIP 6807 CORROSION OUT OF LIMITS ON FLOOR STRUCTURE BEAM BSTA 377 BTW LBL 43 TO LBL 61. CORRECTIVE ACTION: SUMMARY OF NRC 00684: FLOOR STRUCTURE BEAM BSTA 377 BTW LBL 43 TO LBL 61 WAS REPAIRED PER B757-200 SRM. (1951233)SDR DALA2021092005600None · noneSHIP 6807 CORROSION ON GALLEY ATTACH FITTING. ON DECK PLATE(FWD MID) BTA1685. CORRECTIVE ACTION: SUMMARY OF NRC 00478: GALLEY ATTACH FITTING. ON DECK PLATE(FWD MID) BTA1685. WAS REPLACED PER B757-200 SRM. (1951230)SDR SWAA2021102819175Floor Panel · crackedCRACK FLOOR PANEL 120BF IN FWD CARGO. FABRICATED & DRILLED A NEW FLOOR PANEL 120BF IAW SRM 51-40-05, SRM 51-40-08, & DWG 453A1610-8. APPLIED PROTECTIVE TREATMENT IAW SRM 51-20-01-0G-0. REPLACED THE FLOOR PANEL.SDR SWAA2021101318819Floor Panel · corrodedAFT CARGO COMPARTMENT FLOOR PANEL 140DF IS CORRODED / EVALUATED CORROSION IAW SRM 53-00-53-52-1A-1 STEP 5(B) FIG 102 SHEET 1. DAMAGE IS GREATER THAN 20'. FOUND TO BE 'OUT OF LIMITS'. VERIFIED MATERIAL P/N 2024-T3-071 IAW SRM 53-60-53-01-1. FABRICATED NEW PANELSDR SWAA2021101318815Floor Panel · corrodedFORWARD CARGO COMPARTMENT FLOOR PANEL 120AF IS CORRODED / EVALUATED CORRODED AT FWD CARGO FLOOR PNL 120AF FOUND CORROSION EXCEDS 20' FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-1 FABRICATED NEW FLOOR PNL I-A-W MM 25-52-01-201-801SDR SWAA2021101318816Floor Panel · corrodedFORWARD CARGO COMPARTMENT FLOOR PANEL 120CF IS CORRODED / EVALUATED CORRODED AREA ON FLOOR PNL 120CF FOUND LENGTH EXCEDS 20 INCHES FOUND OUT OF LIMITS I-A-W SRM 53-00-53-1A-1 FABRICATED NEW FLOOR PNL I-A-W MM 25-52-01-201-801SDR SWAA2021101318817Floor Panel · corrodedFORWARD CARGO COMPARTMENT FLOOR PANEL 120DF IS CORRODED / EVALUATED CORRODED AREA ON FWD CARGO FLOOR PNL 120DF FOUND EXCED 20' FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-1. FABRICATED NEW FLOOR PNL I-A-W MM 25-52-01-201-801SDR SWAA2021101318818Floor Panel · corrodedAFT CARGO COMPARTMENT FLOOR PANEL 140BF IS CORRODED / EVALUATED CORROSION ON AFT CARGO FLOOR PANEL 140BF. CORROSION IS GREATER THAN 20'. FOUND TO BE 'OUT OF LIMITS' IAW SRM 53-00-53-1A-1 STEP 5(B) FIG 102 SHEET 1. VERIFIED MATERIAL P/N 2024-T3-071 IAW SRM 53-7SDR SWAA2021101318820Floor Panel · corrodedAFT CARGO COMPARTMENT FLOOR PANEL 140EF IS CORRODED / CORROSION EXCEEDS LIMITS IAW SRM 53-00-53-1A-1 FIG 102; VERIFIED CORRECT MATERIAL 2024-T3 .071' IAW AMM 25-52-01-201-801 ATAG# A67405; FABRICATED NEW AFT CARGO FLOOR PANEL 140EF IAW AMM 25-52-01-201-801 PARSDR SWAA2021101318821Floor Panel · corrodedAFT CARGO COMPARTMENT FLOOR PANEL 140AF IS CORRODED / EVALUATED CORROSION ON AFT CARGO COMPARTMENT FLOOR PNL 140AF; TOTAL ACCUMULATED DAMAGE LENGTH FOUND TO EXCEED TH E20' MAX ALLOWED OUT OF LIMITS IAW SRM 53-00-53-1A-1; NEW PANEL FABRICATED IAW AMM 25-52-01-2SDR SWAA2021092017955Floor Panel · crackedFWD CARGO PANEL 120YAC HAS A CRACK 3.5 LONG 27 FROM LH EDGE ; / [01] PERFORMED INTERIM REPAIR ON PANEL 120YAC PER EA M-21-125-00698. INITIAL AND REINSPECT EVERY 8 DAYS. FINAL REPAIR DUE WITHIN 730 DAYS.
Back to JASC 5321