SDR SWAA2021081397440Floor Panel · delaminatedDELAMINATED FLOOR PANEL 232AF AT FWD GALLEY AREA ; 2021-311843 / [01] TOOL USED HOT BONDER P/N HCS9200B S/N 18165044 DUE DATE 15/FEB/22.; [02] REPAIRED FLOOR PANEL 232AF AT FWD GALLEY AREA AS PER B737-700 SRM 53-00-50-2R-1 REPAIR 1; [03] REPAIRED FLOOR PANEL 2SDR SWAA2021081297441Floor Panel · delaminatedDELAMINATED FLOOR PANEL 231AF AT FWD GALLEY AREA ; 2021-311844 / [01] TOOL USED HOT BONDER P/N HCS9200B S/N 18165044 DUE DATE 15/FEB/22.; [02] TOOL USED: SCALE P/N:SCA-301 S/N:AE-412137 DUE DATE:24-FEB-22; [03] REPAIRED FLOOR PANEL 231AF AT FWD GALLEY AREA AS SDR SWAA2021081297437Floor Panel · delaminatedDELAMINATED FLOOR PANEL 222AF AT FWD GALLEY AREA ; 2021-311837 / [01] TOOL USED HOT BONDER P/N HCS9200B S/N 18165044 DUE DATE 15/FEB/22.; [02] TOOL USED SCALE P/N SCA-301 S/N AE-412122 DUE DATE 24/FEB/22.; [03] REPAIRED FLOOR PANEL 222AF AT FWD GALLEY AREA AS SDR SWAA2021081297442Floor Panel · delaminatedDELAMINATED FLOOR PANEL 222BF AT FWD GALLEY AREA ; 2021-311838 / [01] TOOL USED HOT BONDER P/N HCS9200B S/N 18165044 DUE DATE 15/FEB/22.; [02] REPAIRED FLOOR PANEL 222BF AT FWD GALLEY AREA AS PER B737-700 SRM 53-00-50-2R-1 REPAIR 1; [03] REPAIRED FLOOR PANEL 2SDR SWAA2021081297438Floor Panel · delaminatedDELAMINATED FLOOR PANEL 221BF AT FWD GALLEY AREA ; 2021-311840 / [01] TOOL USED HOT BONDER P/N HCS9200B S/N 18165044 DUE DATE 15/FEB/22.; [02] TOOL USED HOT BONDER P/N:HCS9000B S/N:15092096 DUE DATE:14/DEC/21.; [03] TOOL USED SCALE P/N CL5000 S/N AE-408752 DUESDR SWAA2021081297439Floor Panel · delaminatedDELAMINATED FLOOR PANEL 221GF AT FWD GALLEY AREA ; 2021-311842 / [01] TOOL USED HOT BONDER P/N HCS9200B S/N 18165044 DUE DATE 15/FEB/2; [02] TOOL USED HOT BONDER P/N:HCS9200B S/N:18165044 DUE DATE:15-FEB-22; [03] TOOL USED SCALE P/N CL5000 S/N AE-408752 DUE DASDR SWAA2021081297443Floor Panel · delaminatedDELAMINATED FLOOR PANEL 241ZF AT AFT GALLEY AREA ; 2021-311839 / [01] TOOL USED HOT BONDER P/N HCS9200B S/N 18165044 DUE DATE 15/FEB/22.; [02] REPAIRED FLOOR PANEL 241ZF AT AFT GALLEY AREA AS PER B737-700 SRM 53-00-50-2R-1 REPAIR 1; [03] REPAIRED FLOOR PANEL 2SDR SWAA2021081297444Floor Panel · delaminatedDELAMINATED FLOOR PANEL 242WF AT AFT GALLEY AREA ; 2021-311841 / [01] TOOL USED HOT BONDER P/N HCS9200B S/N 18165044 DUE DATE 15/FEB/22.; [02] TOOL USED SCALE P/N SCA-301 S/N AE-412122 DUE DATE 24/FEB/22.; [03] REPAIRED FLOOR PANEL 242WF AT AFT GALLEY AREA AS SDR U2RA2021080400032Floor Panel · dentedDURING 12Y MAINTENANCE CHECK, FOUND CARGO COMPARTMENT FLOOR PANEL 151CF PUNCTURED. ACCOMPLISHED FIBERGLASS OVERLAY REPAIR PER A330 AMM 53-00-00-400-803-A AND EO CTRL #21097-2. REPAIR DIMENSIONS 5" X 6.5" (AREA A) AND 5.5" X 6" (AREA B).SDR U2RA2021080400031Floor Panel · puncturedDURING 12Y MAINTENANCE CHECK, FOUND FLOOR PANEL 151CF PUNCTURED. ACCOMPLISHED FIBERGLASS OVERLAY REPAIR PER A330 AMM 53-00-00-400-803-A, ECQ 720A, AND SVO 37457472. REPAIR DIMENSIONS 7" X 6".SDR U2RA2021080400030Floor Panel · puncturedDURING 12Y MAINTENANCE CHECK, FOUND FLOOR PANEL 152PG PUNCTURED. ACCOMPLISHED FIBERGLASS OVERLAY REPAIR PER A330 AMM 53-00-00-400-803-A, ECQ 720A, AND SVO 37457342. REPAIR DIMENSIONS 6" X 5".SDR U2RA2021080400029Floor Panel · gougedDURING 12Y MAINTENANCE CHECK, FOUND FLOOR PANEL 151RG GOUGED. ACCOMPLISHED FIBERGLASS OVERLAY REPAIR PER EO CTRL # 21097-1. REPAIR DIMENSIONS 1.5" X 2".SDR FDEA202107221840Floor Panel · delaminatedMAIN DECK CARGO COMPARTMENT - CABIN , FLOOR PANEL 243CF FOUND DELAMINATED. ( STATION 735 TO STATION 775 , X = -8.5 TO X = -27.5). DELAMINATED FLOOR PANEL 243CF AT CABIN STATION 735 TO STATION 775 , X = -8.5 TO X = -27.5 REMOVED AS PER AMM 53-21-04. FLOOR PSDR FDEA202107221839Floor Panel · delaminatedMAIN DECK CARGO COMPARTMENT - CABIN , FLOOR PANEL 243BF FOUND DELAMINATED. ( STATION 735 TO STATION 775 , X = 8.5 TO X = -8.5 ). DELAMINATED FLOOR PANEL 243BF AT CABIN STATION 735 TO STATION 775 , X = 8.5 TO X = -8.5 REMOVED AS PER AMM 53-21-04. FLOOR PANESDR FDEA202107221838Floor Panel · delaminatedMAIN DECK CARGO COMPARTMENT - CABIN , LEFT HAND FLOOR PANEL 231HF FOUND DELAMINATED. ( STATION 595 TO STATION 675 ). DELAMINATED LEFT HAND FLOOR PANEL 231HF AT CABIN STATION 595 TO STATION 675 REMOVED AS PER AMM 53-21-04. FLOOR PANEL 231HF FABRICATED AS PESDR IPXA2021080272292Floor Panel · damagedINSPECTION TYPE:A300PNL 221VF DAMAGED.FABBED IAW SREO A300-5320-40552-B.SDR SWAA2021072696680Floor Panel · crackedFWD CARGO PANEL 122ZFC HAS 2 CRACKS 1. 29' FROM FRONT EDGE AND 3' LONG 2. 22' FROM FRONT EDGE OF PANEL AND 1' LONGPERFORMED INTERIM REPAIR ON PANEL 1222ZFC PER EA 1-A25-3722REV.5. EVERY 8 DAYS PERFORM A DETAILED VISUAL INSPECTION OF THE REPAIRED AREA FOR ADDITSDR AALA202107237196Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: AFT CARGO COMPARTMENT FLOOR PANEL 151QE DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-02-00-300-011 AND IRM 9701.SDR AALA202107235242Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: AFT CARGO COMPARTMENT FLOOR PANEL 152JK DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-02-00-300-011 AND IRM 9701.SDR SWAA2021080597072Floor Panel · damagedCABIN FLOOR PANEL 241FF HAS BEEN REMOVED BECAUSE OF INSERT DAMAGE. REPLACED CABIN FLOOR PANEL 241FF PER AMM 53-21-00; [02] REPLACED AND INSTALLED CABIN FLOOR PANEL 241FF PER AMM 53-21-00.SDR IPXA2021080572473Floor Panel · corrodedINSPECTION TYPE:2CFWD CABIN L/H FLOOR PANEL P/N WSP0791-501 IS CORRODED.REMOVED AND REPLACED CORRODED FWD CABIN L/H FLOOR PANEL P/N WSP0791-501 IAW AMM 53-21-04-400-801. (MINOR)SDR FDEA202107211825Floor Panel · delaminatedFORWARD CABIN FLOOR PANEL 227CF FOUND DELAMINATION FROM STATION 422 TO STATION 459 DELAMINATED FLOOR PANEL 227CF AT CABIN STATION 422 TO STATION 459 REMOVED AS PER AMM 53-21-04. FLOOR PANEL 227CF FABRICATED AS PER FEDEX DRAWING SRZ-25-005 REVISION R. FLOSDR SWAA2021072696676Floor Panel · crackedFWD CARGO PANEL 120ZAC HAS A 2' LONG CRACK 27' FROM LH EDGE OF PANELPERFORMED INTERIM REPAIR PER EA 1-A25-3722 REV 5 EVERY 8 DAYS PERFORM A DETAILED VISUAL INSPECTION OF THE REPAIRED AREA FOR ADDITIONAL DAMAGE AND REPAIR INTEGRITY. IF FURTHER DEFECTS ARE NOTEDSDR FDEA202107211829Floorboard · damagedFWD CARGO FLOOR PANEL ADA0241-51(127WF) FABRICATED NEW FLOOR REF FEDEX DWG SRZ-25-005SDR AALA202107222679Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: AFT CARGO COMPARTMENT FLOOR PANEL 151RG DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-02-00-300-011 AND IRM 9701.SDR SWAA2021081098388Floor Panel · corrodedCORROSION ON PANEL 140BF ; / [01] FABRICATED NEW ACB FLOOR PANEL 140BF FROM 071 2024T-3; LOT# 1461004-1 PER AMM 25-52-01-201-801 AND DWG 453A2610; [02] UPDATEDMEASUREMENTS AND ADDED OUT OF LIMITS STATEMENT=CORROSION ON ACB FLOOR PANEL 140DF DETERMINED TO BE OUSDR SWAA2021081096830Floor Panel · corrodedCORROSION ON PANEL 140DF ; / [01] CORROSION ON ACB FLOOR PANEL 140DF DETERMINED TO BE OUT OF LIMIT DUE TO LENGTH OF DAMAGE EXCEEDS 20' IAW SRM 53-00-53-1A-1 FIG 102; PANEL TO BE REPLACED ON FAULT TTG8Q005V6S1; [02] VERIFIED REPLACEMENT TO BE ACCOMPLISHED ON FASDR SWAA2021081096843Floor Panel · corrodedPANEL 140BF IS CORRODED AT ATTACH FASTNER HOLES ; / [01] CORROSION ON ACB FLOOR PANEL 140BF DETERMINED TO BE OUT OF LIMIT DUE TO LENGTH OF DAMAGE EXCEEDS 20' IAW SRM 53-00-53-1A-1 FIG 102; PANEL TO BE REPLACED ON FAULT TTG8Q005V49D; [02] VERIFIED OUT OF LIMITSSDR SWAA2021081096844Floor Panel · corrodedPANEL 140DF IS CORRODED AT ATTACH FASTNER HOLES ; / [01] FABRICATED NEW ACB FLOOR PANEL 140DF FROM 071 2024T-3; LOT# 1461004-1 PER AMM 25-52-01-201-801 AND DWG 453A2610; [02] CORROSION ON ACB FLOOR PANEL 140DF DETERMINED TO BE OUT OF LIMIT DUE TO LENGTH OF DAMSDR SWAA2021081096848Floor Panel · corrodedPANEL 140CF IS CORRODED AT FASTNER ATTACH HOLES ; / [01] FABRICATED NEW ACB FLOOR PANEL 140CF FROM 071 2024T-3 LOT# 1461004-1 PER AMM 25-52-01-201-801 AND DWG 453A2610; [02] CORROSION ON ACB FLOOR PANEL 140CF DETERMINED TO BE OUT OF LIMIT DUE TO LENGTH OF DAMASDR SWAA2021081096849Floor Panel · corrodedPANEL 140AF IS CORRODED AT ATTACH FASTNER HOLES ; / [01] FABRICATED NEW ACB FLOOR PANEL 140AF FROM 071 2024T-3 LOT# 1461004-1 PER AMM 25-52-01-201-801 AND DWG 453A2610; [02] CORROSION ON ACB FLOOR PANEL 140AF DETERMINED TO BE OUT OF LIMIT DUE TO LENGTH OF DAMASDR CALA2021072101144Floor Panel · gougedA3NB-05-3-6022 AFT CARGO FLOOR STRUCTURE I/B FROM DOOR CUTOUT BE TWEEN C58-59 HAS GOUGE. DOT 102-94() REMOVED AND REPLACED SHEET COVER ASSY P/N 5347715400400, BATCH 0 003816227 IAW A319 SRM 51-42-11. RESORED FINISHED PROTECTION IAW A319 SRM 51-75-12. ACCOMPLISSDR SWAA2021090296449Floor Panel · delaminatedAFT CABIN WET AREA FLOOR PANEL 241ADF TOP SURFACE LAYER DELAMINATED STA 890 ; / [01] FABRICATED MAIN CABIN AFT WET AREA FLOOR PNL #241ADF PER BOEING DRAWING#815A0044-1; [02] VERIFIED STEP 1SDR SWAA2021072396364Floor Panel · damagedCABIN FLOOR PANEL 241AF HAS DAMAGED UPPER PLYS. EVALUATED AND FOUND TO BE BER DUE TO MULTIPLE AREAS OF DAMAGE TO UPPER FACE SHEET. FABRICATE NEW BOARD PER SAMPLE IAW SRM 53-00-50-2R-0 STEP1A NOTE AND STEP 4A. FABRICATED FLOOR PANEL PER SAMPLE IAW SRM 53-00-SDR SWAA2021072396365Floor Panel · damagedDOT -04-034 CABIN FLOOR PANEL 231XF HAS DAMAGED UPPER PLYS ; / [01] EVALUATED CABIN FLOOR PANEL 231XF; FOUND PANEL TO BE BEYOND ECONOMICAL REPAIR DUE TO PULLED FIBERS COVERING THE MAJORITY OF THE PANEL. REPLACED CABIN FLOOR PANEL 231XF BY FABRICATING NEW PANELSDR SWAA2021072396367Floor Panel · damagedCABIN FLOOR PANEL 242AF HAS DAMAGED UPPER PLYS. EVALUATED DAMAGE TO UPPER PLIES; DAMAGE IS REPAIRABLE IAW SRM 53-00-50-2R-1. TAP TESTED GOOD, NO DELAMINATION NOTED. CLEANED & PREPPED REPAIR AREA IAW SRM 53-00-50-2R-1 PAR 3; STEPS A;C;E;F;I; AND J. BONDED RSDR SWAA2021081296124Floor Panel · delaminatedDELAMINATED FLOOR PANEL 241ADF AT AFT GALLEY AND LAV ; 2021-311814 / [01] TOOL USED: HOT BONDER P/N:HCS9200B S/N:15102320 DUE DATE:19-NOV-21; SCALE P/N:SCA-301 S/N:AE-412137 DUE DATE:24-FEB-22; [02] TOOL USED: SCALE P/N:SCA-301 S/N:AE-412125 DUE DATE: 24-FEB-2SDR SWAA2021081096166Floor Panel · damagedPANEL 194BL HAS A DAMAGED FASTENER HOLE (MARKED) ; / [01] IDENTIFIED PANEL 194BL MATERIAL IAW SRM 53-60-70-0I-1 TABLE 2 FIGURE 2 ITEM 10. DAMAGE AT DISCREPANT LOCATION EXCEEDS ALLOWABLE DAMAGE LIMITS IAW SRM 53-60-70-1A-1 PARAGRAPH 4.C(6). DAMAGE WILL BE REPAISDR SWAA2021072296703Floor Panel · tornFWD CARGO COMPT; AFT FLOOR PANEL TORN BEYOND LIMITS TO REPAIR ; / [01] OK TO CONT PER MEL 25-16-01 SP1B AUTH #18656; [02] R/R FWD CARGO COMPT; AFT FLOOR PANEL REF AMM 25-52-10SDR IPXA2021073172302Floor Panel · damagedINSPECTION TYPE:CPNL 231SG BROKENFABBED IAW SREO A300-5320-40552-BSDR IPXA2021072772152Floor Panel · damagedINSPECTION TYPE:SEGPNL 252BN DAMAGEDFABBED IAW SREO A300-40552-BSDR IPXA2021072572049Floor Panel · brokenINSPECTION TYPE:SEGMAIN CARGO DECK FLOOR PANEL 232QH 4TH HOLE BACK OUTBOARD SCREW IS STILL INSTALLED AND HONEYCOMB BROKENCOMPLIED WITH SREO A300-5320-42722-FSDR SWAA2021072195862Floor Panel · crackedFWD CARGO BIN FLOORING CRACKED ; / [01] OK TO CONTINUE PER MEL 25-16-01 SP#1B<BR>AUTH# 18481; [02] REF# 1874323 WORKING MEL 25-16-01 REMOVED AND REPLACED PANEL 120CF IAW AMM 25-52-10 CLEARS MEL ON LP# 1874326SDR SWAA2021090295419Floor Panel · delaminatedAFT CABIN FLOOR PANEL 241AAF TOP SURFACE LAYER DELAMINATED STA 960 ; / [01] FABRICATED AFT WET AREA CABIN FLOOR PANEL 241AAF PER B737-700 SRM 53-00-50-2R-0.; [02] VERIFIED FABRICATED AFT WET AREA CABIN FLOOR PANEL 241AAFSDR SWAA2021090295417Floor Panel · delaminatedAFT CABIN FLOOR PANEL 241YF TOP SURFACE LAYER DELAMINATED ; / [01] BEGAN FABRICATION OF AFT WET AREA CABIN FLOOR PANEL 241YF; PERFORMED CUT OUT; LOCATING; DRILLING AND INSTALLED INSERTS PER B737-700 SRM 53-00-50-2R-0.; [02] MEASUREMENTS; [03] FABRICATE NEW FLOSDR SWAA2021090295422Floor Panel · delaminatedAFT CABIN WET AREA. FLOOR PANEL 241ACF TOP SURFACE LAYER DELAMINATED ; / [01] BEGAN FABRICATION OF AFT WET AREA CABIN FLOOR PANEL 241ACF; PERFORMED CUT OUT; LOCATING; DRILLING AND INSTALLED INSERTS PER B737-700 SRM 53-00-50-2R-0.; [02] MEASUREMENTS; [03] FABRISDR SWAA2021090295413Floor Panel · delaminatedAFT CABIN WET AREA FLOOR PANEL 241ABF TOP SURFACE LAYER DELAMINATED ; / [01] MEASUREMENTS; [02] CLEANED FLOOR PANEL #241ABF TOP SURFACE PREPARED DAMAGE AREAS FOR REPAIR PERFORMED DRY OUT FOUND NO WATER AS PER B737 SRM 53-00-50-2R-7; [03] REPAIRED DAMAGE AREA OSDR SWAA2021090295414Floor Panel · corrodedCORROSION>>>>> FWD WET AREA FLOOR PANEL 221DF SEVERAL INSERTS CORRODED ; / [01] REMOVED PANEL 221DF REF: AMM 53-21-00-000-801. INSTALLATION OF NEW PANEL WILL BE ACCOMPLISHED ON TASK CARD TTG8Q005EFEE; [02] VERIFIED NEW PANELSDR SWAA2021090295418Floor Panel · delaminatedAFT CABIN WET AREA FLOOR PANEL 241XF TOP SURFACE LAYER DELAMINATED STA 890 ; / [01] FABRICATED AFT WET AREA CABIN FLOOR PANEL 241XF PER B737-700 SRM 53-00-50-2R-0 AND DWG 815A0044-5.; [02] VERIFIED 1;COMPLETESDR SWAA2021090295420Floor Panel · delaminatedAFT CABIN FLOOR PANEL 242UF STA 960 TOP SURFACE LAYER DELAMINATED ; / [01] MEASUREMENTS; [02] CLEANED AREA PERFORMED DRYING PROCESS NO WATER FOUND PREPARED AREA FOR REPAIR ON TOP SURFACE OF FLOOR PANEL #242UF AS PER B737 SRM 53-00-50-2R-7; [03] REPAIRED DAMAGE
Back to JASC 5321