JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2016031602605Floorboard · delaminatedMAIN CABIN FLOORBOARD NR 222GF IS DELAMINATED. FLOORBOARD FOUND TO BE 50 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. REMOVED, FABRICATED AND INSTALLED A NEW FLOORBOARD IAW SRM 53-20-50, REPAIR 3, DWG NR 9936688, REV H, AND AMM SDR DALA2016031602185Floor Panel · corrodedAFT CABIN FLOOR PANEL 262FF IS CORRODED. REPLACED THE FLOOR PANEL IAW SRM 57-72-11. NO LIMITS IN SRM.SDR DALA2016031602184Floor Panel · corrodedAFT CABIN FLOOR PANEL IS CORRODED. REPLACED THE FLOOR PANEL IAW SRM 51-72-11. NO LIMITS IN SRM.SDR AALA201603179011Floor Panel · delaminatedAIRCRAFT IN BASE MX. FLOOR PANEL 261CG HAS CORRODED INSERTS & IS DELAMINATED. REPLACED FLOOR PANEL IAW IRM 9701 REV G.SDR DALA2016031602005Floor Panel · damagedBROKEN AND MISSING NUT ON FLOOR PANEL 200A. THE FLOOR PANEL WAS REPAIRED IAW SRM 51-70-10, SRM 51-30-2 AND DWG 9952523.SDR DALA2016031502603Floorboard · delaminatedMAIN CABIN FLOORBOARD 222JF IS DELAMINATED. FLOORBOARD FOUND TO BE 50 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. REMOVED, FABRICATED AND INSTALLED A NEW FLOORBOARD IAW SRM 53-20-50, REPAIR 3, DWG NR 9936585, REV G, AND AMM 53-SDR DALA2016031502602Floorboard · delaminatedMAIN CABIN FLOORBOARD 222BF IS DELAMINATED. FLOORBOARD FOUND TO BE 40 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. REMOVED, FABRICATED A NEW FLOORBOARD AND INSTALLED IAW SRM 53-20-50 REPAIR 3, DWG NR 9936585, REV G, AND AMM 53-2SDR DALA2016031502601Floorboard · delaminatedMAIN CABIN FLOORBOARD 222AVF IS DELAMINATED. FLOORBOARD FOUND TO BE 50 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. REMOVED AND FABRICATED A NEW FLOORBOARD. INSTALLED THE FLOORBOARD IAW SRM 53-20-50, REPAIR 3, DWG 9936584, RESDR DALA2016031502600Floorboard · delaminatedMAIN CABIN FLOORBOARD NR 221LF IS DELAMINATED. FLOORBOARD FOUND TO BE 50 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED A NEW FLOORBOARD IAW SRM 53-20-50, REPAIR 3 AND DWG 9936553, REV C.SDR DALA2016031502599Floorboard · delaminatedMAIN CABIN FLOORBOARD 211ALF IS DELAMINATED. FLOORBOARD FOUND TO BE 50 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED A NEW FLOORBOARD IAW SRM 53-20-50 REPAIR 3 AND DWG 9936537, REV AG.SDR DALA2016031502598Floorboard · delaminatedMAIN CABIN FLOORBOARD 221AF IS DELAMINATED. FLOORBOARD FOUND TO BE 40 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED A NEW FLOORBOARD IAW SRM 53-20-50. REPAIR 3 AND DWG 9936544, REV G.SDR DALA2016031502597Floorboard · delaminatedMAIN CABIN FLOORBOARD NR 221KF IS DELAMINATED. FLOORBOARD FOUND TO BE 40 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED A NEW FLOORBOARD IAW SRM 53-20-50, REPAIR 3 AND DWG 9936552, REV K.SDR DALA2016031502596Floorboard · delaminatedMAIN CABIN FLOORBOARD 221DF IS DELAMINATED. FLOORBOARD FOUND TO BE 50 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED A NEW FLOORBOARD IAW SRM 53-20-50, REPAIR 3 AND DWG 9936547, REV W.SDR DALA2016031502595Floorboard · delaminatedMAIN CABIN FLOORBOARD 221HF IS DELAMINATED. FLOORBOARD FOUND TO BE 50 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED A NEW FLOORBOARD IAW SRM 53-20-50, REPAIR 3 AND DWG 9965855, REV G.SDR DALA2016031502594Floorboard · delaminatedMAIN CABIN FLOORBOARD 221CF IS DELAMINATED. FLOORBOARD FOUND TO BE 30 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED A NEW FLOORBOARD IAW SRM 53-20-50, REPAIR 3 AND DWG 9936546, REV C.SDR DALA2016031502593Floorboard · delaminatedMAIN CABIN FLOORBOARD 221EF IS DELAMINATED. FLOORBOARD FOUND TO BE 40 PERCENT DELAMINATED AND OUT OF LIMITS IAW 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED A NEW FLOORBOARD IAW SRM 53-20-50, REPAIR 3 AND DWG 9936549 REV K.SDR DALA2016031502592Floorboard · delaminatedMAIN CABIN FLOORBOARD 221FF IS DELAMINATED. FLOORBOARD FOUND TO BE 50 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED A NEW FLOORBOARD IAW SRM 53-20-50, REPAIR 3 AND DWG 9936547, REV W.SDR DALA2016031502591Floorboard · delaminatedMAIN CABIN FLOORBOARD 221JF IS DELAMINATED. FLOORBOARD FOUND TO BE 30 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED A NEW FLOORBOARD IAW SRM 53-20-50, REPAIR 3 AND DWG NR 9936551, REV AN.SDR IPXA2016031400686Floorboard · damagedMAIN CARGO DECK FLOORBOARD DAMAGE AT POSITION 10L. FABRICATED A NEW FLOORBOARD IAW EO A300-5320-40552-B AND EO A300-5320-16407-E.SDR AALA20160330009Floor Support · crackedAIRCRAFT WAS GNDED. CABIN FLOOR PANEL BETWEEN SEATS 20B & 20D REPORTED TO BE SOFT. FOUND FLOOR PANEL SUPPORTS, 2 EACH, CRACKED. R & R SUPPORTS. SEE ALSO AALA 20160317006.SDR DALA2016031401911Doubler · corrodedCORROSION ON DOUBLER REPAIR FROM BS 640 TO BS 651 BETWEEN X=60 TO X=54 AT RT FLOOR CABIN PASSENGER AREAS WERE REPAIR IAW SRM 53-05, FIG 131A-2, SHEET 5.SDR DALA2016031302590Floorboard · delaminatedMAIN CABIN FLOORBOARD 222APF IS DELAMINATED. FLOORBOARD FOUND TO BE 30 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50, ALLOWABLE DAMAGE 1. FABRICATED A NEW FLOORBOARD IAW SRM 53-20-50 REPAIR 3 AND DWG 9936585, REV G.SDR DALA2016031302589Floorboard · delaminatedMAIN CABIN FLOORBOARD 222AMF IS DELAMINATED. FLOORBOARD FOUND TO BE 50 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED A NEW FLOORBOARD IAW IAW SRM 53-20-50. REPAIR 3 AND DWG 9936585, REV G.SDR DALA2016031302588Floorboard · delaminatedMAIN CABIN FLOORBOARD 222AHF IS DELAMINATED. FLOORBOARD FOUND TO BE 50 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED A NEW FLOORBOARD IAW SRM 53-20-50, REPAIR 3 AND DWG 9936585, REV G.SDR DALA2016031302587Floorboard · delaminatedMAIN CABIN FLOORBOARD 222AGF IS DELAMINATED. FLOORBOARD FOUND TO BE 30 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED A NEW FLOORBOARD IAW SRM 53-20-50, REPAIR 3 AND DWG 9936585, REV G.SDR DALA2016031302586Floorboard · delaminatedMAIN CABIN FLOORBOARD 222AAF IS DELAMINATED. FLOORBOARD FOUND TO BE 50 PERCENT DELAMINTED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED A NEW FLOORBOARD IAW SRM 53-20-50, REPAIR 3 AND DWG 9936640, REV D.SDR DALA2016031302585Floorboard · delaminatedMAIN CABIN FLOORBOARD 222ABF IS DELAMINATED. FLOORBOARD FOUND TO BE 40 PERCNET DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED A NEW FLOORBOARD IAW SRM 53-20-50, REPAIR 3 AND DWG 9936640, REV D.SDR DALA2016031302584Floorboard · delaminatedMAIN CABIN FLOORBOARD 221BF IS DELAMINATED. FLOORBOARD FOUND TO BE 50 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED A NEW FLOORBOARD IAW SRM 53-20-50, REPAIR 3 AND DWG 9936545, REV M.SDR DALA2016031302583Floorboard · delaminatedMAIN CABIN FLOORBOARD 221UF IS DELAMINATED. FLOORBOARD FOUND TO BE 40 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED A NEW FLOORBOARD IAW SRM 53-20-50, REPAIR 3 AND DWG 9936585, REV G.SDR DALA2016031302582Floorboard · delaminatedMAIN CABIN FLOORBOARD 211ANF IS DELAMINATED. FLOORBOARD FOUND TO BE 40 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED A NEW FLOORBOARD IAW SRM 53-20-50, REPAIR 3 AND DWG 9936539, REV AB.SDR DALA2016031302581Floorboard · delaminatedMAIN CABIN FLOORBOARD 222PF IS DELAMINATED. MAIN CABIN FLOORBOARD FOUND TO BE 40 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50, ALLOWABLE DAMAGE 1. FABRICATED NEW FLOORBOARD IAW SRM 53-20-50, REPAIR 3 AND DWG 9936585, REV G.SDR DALA2016031302580Floorboard · delaminatedMAIN CABIN FLOORBOARD 223DF IS DELAMINATED. MAIN CABIN FLOORBOARD FOUND TO BE 30 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED NEW FLOORBOARD IAW SRM 53-20-50 REPAIR 3 AND DWG 9936688, REV H.SDR ASAA2016031216079Floor Panel · corrodedAFT PIT NR 2 FLOOR PANEL IS CORRODED. ACFT GROUNDED. FABRICATED NR 2 AFT PIT PANEL IAW SRM 51-40-05-0G-0, PAGE 4, FIG 2, ALODINE NR 2 AFT PIT PANEL IAW SRM 51-20-01-0G-0, PAGE 4, STEP F, PRIMED NR 2 AFT PIT PANEL IAW BSOPM 20-41-02, PAGE 7, STEP F, TABLE 2. SDR ASAA2016031216074Floor Panel · corrodedFWD CARGO NR 4 FLOOR PANEL IS CORRODED. ACFT GROUNDED. REMOVED CORROSION AND CHECKED LIMTS FOUND FLOOR PANEL OUT OF LIMITS IAW SRM 53-60-53-1A-1, FIG 101 FABRICATED NEW FLOOR PANEL IAW SRM 51-40-05-0G-0, FIG 2 TO BE INSTALLED ON WO 1012735 1000-0159, W/O 327SDR DALA2016031301894Floor Panel · delaminatedFLOOR PANEL DELAMINATED FROM BS 110 TO 256 AT CABIN PAX. FLOOR PANEL FABRICATED IAW AMM 53-20-01-201.SDR AALA201603249011Floor Panel · delaminatedAIRCRAFT IN BASE MX. DELAMINATION ON FLOOR PANEL 251 LF, BETWEEN FRAME 54 & 58 AT -Y254 & Y254. REPLACED FLOOR PANEL 251 LF IAW SRM 53-02-00-201 PAR 8H FIG 209 IRM 9701 REV G.SDR AALA201603249010Floor Panel · delaminatedAIRCRAFT IN BASE MX. DELAMINATION ON FLOOR PANEL 251 RF IN PAX CABIN, BETWEEN FRAME 58 & 62 AT -Y254 & Y254. REPLACED FLOOR PANEL 251 RF IAW SRM 53-02-00-201 PAR 8H FIG 209 IRM 9701.SDR AALA201603249015Floor Panel · delaminatedAIRCRAFT IN BASE MX. DELAMINATION ON FLOOR PANEL 252SF IN PAX CABIN, BETWEEN FRAME 58 & 62 AT -Y765 TO -Y254. REPLACED FLOOR PANEL 252SF IAW SRM 53-02-00-201 PAR 8H FIG 209 IRM 9701 REV G.SDR ASAA2016031115950Floor Panel · damagedAFT CARGO COMPARTMENT FLOOR PANEL 140EF HAS SEVERAL ELONGATED FASTENER HOLES. ACFT GROUNDED. FABRICATED AFT CARGO COMPARTMENT FLOOR PANEL 140EF IAW DWG 453A2610, REV A AND ALODINED AND PRIMED IAW SRM 51-20-01. PANEL IS GONNA BE INSTALLED, CUSTOMER CARD G6600SDR DALA2016031201885Floor Panel · corrodedCORROSION OR FLOOR PANEL 160G. FLOOR PANEL 160G WAS REPLACED; A NEW WAS FABRICATED IAW SRM 51-10-2, 51-10-4 AND DGW 9957828AB.SDR AALA201603249009Floor Panel · delaminatedAIRCRAFT IN BASE MX. DELAMINATION ON FLOOR PANEL 231WF IN PAX CABIN, BETWEEN FRAME 32 & 35, AT Y765 & Y1292. REPLACED FLOOR PANEL 231WF IAW SRM 53-02-00-201 PAR 8H FIG 209 & IRM 9701 REV G.SDR AALA201603249014Floor Panel · delaminatedAIRCRAFT IN BASE MX. DELAMINATION ON FWD GALLEY FLOOR PANEL 222EF, BETWEEN FRAME 13 & 20, AT -Y765 & Y254. REPLACED FLOOR PANEL IAW SRM 53-12-00-201 PAR 5F FIGURE 206 IRM 9701 REV G.SDR AALA201603249018Floor Panel · delaminatedAIRCRAFT IN BASE MX. DELAMINATION ON FLOOR PANEL 231KF IN PAX CABIN, BETWEEN FRAME 24 & 28 AT -Y254 & Y254. REPLACED FLOOR PANEL 231KF IAW SRM 53-02-00 PAR 8H FIG 209 IRM 9701 REV G.SDR AALA201603249017Floor Panel · delaminatedAIRCRAFT IN BASE MX. DELAMINATION ON FLOOR PANEL 231RF IN PAX CABIN, BETWEEN FRAME 28 & 32 AT -Y254 TO -Y765. REPLACED FLOOR PANEL IAW SRM 53-02-00-201 PAR 8H FIG.209 & IRM 9701 REV G.SDR AALA201603249016Floor Panel · delaminatedAIRCRAFT IN BASE MX. DELAMINATION ON FLOOR PANEL 221EF IN FWD GALLEY AREA, BETWEEN FRAME 20 & 24 AT -Y254 TO Y765. REPLACED FLOOR PANEL IAW SRM 53-12-00-201 PAR 5F FIGURE 206 & IRM 9701 REVISION G.SDR IPXA2016031600811Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XBF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016031600799Floor Panel · damagedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 221XCF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR FDEA201603100892Floor Panel · delaminatedMAIN DECK, STATION 1661 - 1741, RBL 38. R & R FLOOR PANEL 282CF.SDR FDEA201603100891Floor Panel · delaminatedMAIN DECK, STATION 1561 - 1661, RBL 38 IS DELAMINATED. R & R FLOOR PANEL 282AF.SDR IPXA2016040501675Floor Panel · corrodedINSPECTION TYPE:3C, MAIN CABIN RCB FLOOR PANEL HAS CORROSION BS 490 TO 500 X=-27.5 TO X= 32. ACCOMPLISHED BLEND REPAIR ON MAIN CABIN RCB FLOOR PANEL BS 490 TO 500 X=-27.5 TO X= -32 IAW EA 011-5310-01-A6163, REV I/R AND EO MD11-5310-60278-A.
Back to JASC 5321