SDR ASAA2016011815203Floor Panel · delaminatedFLOOR PANEL NR 2337 HAS AN AREA OF DELAMINATION. ACFT GROUNDED. REPAIRED AREA OF DELAMINATION ON FLOOR PANEL NR 2337 IAW SRM 53-00-50-2R-0, PARA 3.B, PG 1.SDR ASAA2016011815202Floor Panel · delaminatedFLOOR PANEL 2331 HAS AN AREA OF DELAMINATION. ACFT GROUNDED. REPAIRED AREA OF DELAMINATION ON FLOOR PANEL NR 2331 IAW SRM 53-00-50-2R-0, PARA 3.B, PG 1.SDR ASAA2016011815201Floor Panel · delaminatedFLOOR PANEL NR 2472 HAS AN AREA OF DELAMINATED. ACFT GROUNDED. REPAIRED AREA OF DELAMINED ON FLOOR PANEL NR 2472 IAW SRM 53-00-50-2R-0, PARA 3.B.SDR ASAA2016011815200Floor Panel · delaminatedFLOOR PANEL NR 2473 HAS AN AREA OF DELAMINATED AND EDGE DAMAGE. ACFT GROUNDED. REPAIRED FLOOR PANEL NR 2473 DELAMINATED AND EDGE DAMAGE IAW SRM 53-00-50-2R-0, PARA 3.B, PG 1.SDR AALA201601299025Floor Panel · delaminatedAIRCRAFT IN BASE MX. AFT GALLEY FLOOR PANEL 261PF DELAMINATED. REPLACED FLOOR PANEL IAW IRM 9701 REV G.SDR DALA2016011900440Floor Panel · delaminatedDELAMINATED FLOOR PANEL. FLOOR PANEL FABRICATED IAW AMM 53-20-01-201.SDR AALA201601209012Floor Panel · delaminatedAIRCRAFT WAS IN BASE MX. CABIN FLOOR PANEL 221EF HAS A 10 INCH AREA OF DELAMINATION. FABRICATED & INSTALLED REPLACEMENT PANEL IAW IRM 9701 REV G.SDR IPXA2016012198148Floor Panel · damagedINSPECTION TYPE:5 YR, MAIN CABIN FLOOR PANEL 231MJ HAS A BROKEN CORNER. REPAIRED FLOOR PANEL IAW SREO A300-5320-42721-F.SDR DALA2016011700411Floor Panel · corrodedCORROSION ON FLOOR PANEL 160G. THE FLOOR PANEL WAS REPLACE IAW DWG 9957828 AND CORROSION ON FILLER WAS ATTENDED IAW SRM 51-10-3, PAR 26-21-14.SDR AALA201601299013Floor Panel · delaminatedAIRCRAFT IN BASE MX. AFT CARGO COMPARTMENT FLOOR PANEL 151VG DELAMINATED. REPLACED FLOOR PANEL IAW IRM 9701 REV G.SDR AALA201602109006Floor Panel · delaminatedAIRCRAFT IN BASE MX. BULK CARGO COMPARTMENT FLOOR PANEL 161AF DELAMINATED. REPLACED FLOOR PANEL IAW IRM 9701 REV G.SDR AALA201602099015Floor Panel · delaminatedAIRCRAFT WAS IN BASE MX. CABIN FLOOR PANEL 151AF IS DELAMINATED. R & R FLOOR PANEL IAW SRM 53-02-00 PARA 8H FIG 209 & IRM 9701 REV G.SDR AALA201602099012Floor Panel · delaminatedAIRCRAFT WAS IN BASE MX. CABIN FLOOR PANEL 151DF IS DELAMINATED. R & R FLOOR PANEL IAW SRM 53-02-00 PARA 8H FIG 209 & IRM 9701 REV G.SDR AALA201602099011Floor Panel · delaminatedAIRCRAFT WAS IN BASE MX. CABIN FLOOR PANEL 151MF IS DELAMINATED. R & R FLOOR PANEL IAW SRM 53-02-00 PARA 8H FIG 209 & IRM 9701 REV G.SDR AALA201602099010Floor Panel · delaminatedAIRCRAFT WAS IN BASE MX. CABIN FLOOR PANEL 131JF IS DELAMINATED. R & R FLOOR PANEL IAW SRM 53-02-00 PARA 8H FIG 209 & IRM 9701 REV G.SDR AALA201602099009Floor Panel · delaminatedAIRCRAFT WAS IN BASE MX. CABIN FLOOR PANEL 151CF IS DELAMINATED. R & R FLOOR PANEL IAW SRM 53-02-00 PARA 8H FIG 209 & IRM 9701 REV G.SDR AALA201602099008Floor Panel · delaminatedAIRCRAFT WAS IN BASE MX. CABIN FLOOR PANEL 151BF IS DELAMINATED. R & R FLOOR PANEL IAW SRM 53-02-00 PARA 8H FIG 209 & IRM 9701 REV G.SDR AALA201602059038Floor Panel · crackedAIRCRAFT IN BASE MX. CABIN FLOOR PANEL 271CF IS CRACKED ON BOTTOM SIDE INSERT HOLES. REPLACED FLOOR PANEL IAW SRM 53-02-00.SDR DALA2016011400303Channel · crackedCRACKED CHANNEL OF FLOOR PANEL. FLOOR PANEL REPAIRED IAW SRM 53-05, FIG 131B, AND SRM 51-70-1D PAR 10. HFEC INSPECTION WAS ACCOMPLISHED NO CRACKS FOUND AFTER STOP DRILL.SDR DALA2016012200580Floor Panel · damagedMAIN CABIN FLOOR PANEL 221 AF IS DAMAGED. MAIN CABIN FLOOR PANEL 221AF FOUND TO BE 50 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50. ALLOWABLE DAMAGE 1. FABRICATED NEW FLOOR PANEL NR 221AF DIM 36" X 11" IAW SRM 53-20-50, REPAIR 3 AND DWG 9936544, RESDR DALA2016011900471Floor Panel · puncturedMAIN CABIN FLOOR PANEL NR 222ZF HAS A PUNCTURE APPROXIMATELY BS 730, RBL 46. CUTOUT DAMAGED AREA ON MAIN CABIN FLOOR PANEL NR 222ZF, DIM 1.8" X 1.2", FABRICATED REPAIR PARTS, AND INSTALLED REPAIR PARTS, DOUBLER DIM. 4" X 5" IAW SRM 53-20-50, REPAIR 2.SDR DALA2016011600427Floorboard · delaminatedMAIN CABIN FLOORBOARD NR 211ATF IS DELAMINATED. FOUND TO BE 30 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED A NEW FLOORBOARD IAW SRM 53-20-50, REPAIR 3 AND DWG DWG 9936539, REV AB.SDR DALA2016011500360Floor Panel · damagedMAIN CABIN FLOOR PANEL 221BF IS DAMAGED. MAIN CABIN FLOOR PANEL 221BF FOUND TO BE 40 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED NEW FLOOR PANEL 221 BF DIM 40" X 36" IAW SRM 53-20-50 REPAIR 3 AND DWG 9936545, REV M.SDR DALA2016011500359Floorboard · delaminatedMAIN CABIN FLOORBOARD 221LF IS DELAMINATED. MAIN CABIN FLOOR PANEL 221LF FOUND TO BE 40 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED NEW FLOOR PANEL 221LF DIM 21" X 56" IAW SRM 53-20-50, REPAIR 3. DWG 9936553, REV: C.SDR DALA2016011500358Floorboard · delaminatedMAIN CABIN FLOORBOARD 211ANF IS DELAMINATED. MAIN CABIN FLOOR PANEL 211 AND FOUND TO BE 30 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED NEW FLOOR PANEL 211ANF DIM 22" X 29" IAW SRM 53-20-50, REPAIR 3 AND DWG 9936539 REVSDR DALA2016011500357Floorboard · delaminatedMAIN CABIN FLOORBOARD 222AEF IS DELAMINATED. MAIN CABIN FLOOR PANEL 222 AEF FOUND TO BE 30 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED NEW FLOOR PANEL 222AEF DIM 21" X 41" IAW SRM 53-20-50 REPAIR 3 AND DWG 9936640, RESDR DALA2016011500356Floor Panel · damagedMAIN CABIN FLOOR PANEL 221EF IS DAMAGED. MAIN CABIN FLOOR PANEL NR 221EF FOUND TO BE 40 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED NEW FLOOR PANEL 221EF DIM 40" X 9" IAW SRM 53-20-50. REPAIR 3 AND DWG 9936549, REV KSDR DALA2016011500355Floorboard · delaminatedMAIN CABIN FLOORBOARD, 211ALF IS DELAMINATED. MAIN CABIN FLOOR PANEL NR 211ALF FOUND TO BE 50 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50, ALLOWABLE DAMAGE 1. FABRICATED NEW FLOOR PANEL NR 211ALF DIM 40" X 29" IAW SRM 53-20-50, REPAIR 3 AND DWG 993SDR DALA2016011500354Floorboard · delaminatedMAIN CABIN FLOORBOARD NR 222GF IS DELAMINATED. MAIN CABIN FLOOR PANEL NR 222GF FOUND TO BE 30 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED NEW FLOOR PANEL 222GF DIM 21" X 19" IAW SRM 53-20-50, REPAIR 3 AND DWG 9936688 SDR DALA2016011500353Floorboard · delaminatedMAIN CABIN FLOORBOARD 222ACF IS DELAMINATED. MAIN CABIN FLOOR 222ACF FOUND TO BE 50 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED NEW FLOOR PANEL NR 222ACF DIM 21" X 41" IAW SRM 53-20-50, REPAIR 3 AND DWG 9936640, REVSDR DALA2016011500352Floorboard · delaminatedMAIN CABIN FLOORBOARD 222LF IS DELAMINATED. MAIN CABIN FLOOR PANEL 222LF FOUND TO BE 40 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED NEW FLOOR PANEL NR 222LF DIM 21" X 76" IAW SRM 53-20-50. REPAIR 3 AND DWG 9936585, SDR DALA2016011500351Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 221CF IS DAMAGED. MAIN CABIN FLOOR PANEL 221CF FOUND TO BE 40 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE. FABRICATED NEW FLOOR PANEL NR 221CF DIM 40" X 12" IAW SRM 53-20-50, REPAIR 3 AND DWG 9936546, REV C.SDR DALA2016011500341Floor Panel · damagedMAIN CABIN FLOOR PANEL 221DF IS DAMAGED. MAIN CABIN FLOOR PANEL 221DF FOUND TO BE 50 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED NEW FLOOR PANEL NR 221DF DIM 20" X 36" IAW SRM 53-20-50. REPAIR 3 AND DWG 9936585, RESDR DALA2016011500340Floorboard · delaminatedMAIN CABIN FLOORBOARD NR 222AVF IS DELAMINATED. MAIN CABIN FLOOR PANEL NR 222AVF FOUND TO BE 40 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED NEW FLOOR PANEL 222AVF DIM 42" X 65" IAW SRM 53-20-50, REPAIR 3 AND DWG 993658SDR DALA2016011500339Floor Panel · damagedMAIN CABIN FLOOR PANEL 221FF IS DAMAGED. MAIN CABIN FLOOR PANEL 221FF FOUND TO BE 40 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED NEW FLOOR PANEL DIM 20" X 36" IAW SRM 53-20-50 REPAIR 3 AND DWG 9936585, REV: W.SDR DALA2016011500338Floorboard · delaminatedMAIN CABIN FLOORBOARD NR 211ASF. IS DELAMINATED. MAIN CABIN FLOOR PANEL NR 222ASF FOUND TO BE 50 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED NEW FLOOR PANEL 211, ASF DIM 11" X 15" IAW SRM 53-20-50, REPAIR 3 AND DWG 9SDR DALA2016011500337Floorboard · delaminatedMAIN CABIN FLOORBOARD 211 ARF IS DELAMINATED. MAIN CABIN FLOOR PANEL NR 211 ARF FOUND TO BE 50 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED NEW FLOOR PANEL NR 211ARF DIM 11" X 15" IAW SRM 53-20-50. REPAIR 3 AND DWG 99SDR DALA2016011500335Floorboard · delaminatedMAIN CABIN FLOORBOARD 222FF IS DELAMINATED. MAIN CABIN FLOORBOARD FOUND TO BE 60 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50, ALLOWABLE DAMAGE 1. FABRICATED A NEW FLOORBOARD IAW SRM 53-20-50. REPAIR 3 AND DWG 9936583, REV: E.SDR DALA2016011500334Floorboard · delaminatedMAIN CABIN FLOORBOARD 222APF IS DELAMINATED. MAIN CABIN FLOOR PANEL 222APF FOUND TO BE 30 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED NEW FLOOR PANEL 222APF DIM 21" X 76" IAW SRM 53-20-50, REPAIR 3 AND DWG 9936585, RESDR DALA2016011500332Floorboard · delaminatedMAIN CABIN FLOORBOARD 222RF IS DELAMINATED. MAIN CABIN FLOOR PANEL 222RF FOUND TO BE 50 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50, ALLOWABLE DAMAGE 1. FABRICATED NEW FLOOR PANEL NR 222RF DIM 21" X 76" IAW SRM 53-20-50. REPAIR 3 AND DWG 9936585, SDR DALA2016011500331Floor Panel · damagedMAIN CABIN FLOOR PANEL 221JF IS DAMAGED. MAIN CABIN FLOOR PANEL NR 221JF FOUND TO BE 30 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED NEW FLOOR PANEL DIM 60" X 8" IAW SRM 53-20-50, REPAIR 3 AND DWG 9936551, REV: AN.SDR DALA2016011500330Floorboard · delaminatedMAIN CABIN FLOORBOARD 223DF IS DELAMINATED. MAIN CABIN FLOOR PANEL 223DF FOUND TO BE 30 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED NEW FLOOR PANEL 223DF DIM 21" X 19" IAW SRM 53-20-50, REPAIR 3 AND DWG 9936688, REV: SDR DALA2016011500329Floorboard · delaminatedMAIN CABIN FLOORBOARD 222DF IS DELAMINATED. MAIN CABIN FLOOR PANEL 222DF FOUND TO BE 30 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50 ALLOWABLE DAMAGE 1. FABRICATED NEW FLOOR PANEL 222DF DIM 21" X 19" IAW SRM 53-20-50, REPAIR 3 AND DWG 9936688, REV: SDR DALA2016011500328Floorboard · delaminatedMAIN CABIN FLOORBOARD 221WF IS DELAMINATED. MAIN CABIN FLOOR PANEL 221WF FOUND TO BE 40 PERCENT DELAMINATED AND OUT OF LIMITS IAW SRM 53-20-50, ALLOWABLE DAMAGE 1. FABRICATED FLOOR PANEL 221 WF DIM 21" X 76" IAW SRM 53-20-50, REPAIR 3 AND 9936585, REV: G.SDR DALA2016011500327Floor Panel · puncturedAFT CABIN FLOOR PANEL UPPER SKIN IS PUNCTURED AT FS 986 BETWEEN RBL 44 AND RBL 54. REPAIRED AFT CABIN FLOOR PANEL UPPER SKIN AT FS 986, RBL 44-54 IAW SRM 53-20-50, REPAIR 2 AND DWG 9956320, REV: G.SDR DALA2016011400291Floor Panel · puncturedPUNCTURES ON FLOOR PANEL OF PASSENGER CABIN. FLOOR PANEL WERE FABRICATED IAW AMM 53-20-01-201.SDR AALA201602059037Floor Panel · crackedAIRCRAFT IN BASE MX. FWD CABIN FLOOR PANEL 231JF HAS CRACKS. REPLACED FLOOR PANEL IAW SRM 53-02-00.SDR AALA201602059036Floor Panel · delaminatedAIRCRAFT IN BASE MX. FWD CABIN FLOOR PANEL 221EF IS DELAMINATED. REPLACED FLOOR PANEL IAW SRM 53-02-00.SDR AALA201602059035Floor Panel · crackedAIRCRAFT IN BASE MX. FWD CABIN FLOOR PANEL 222JF HAS CRACKS. REPLACED FLOOR PANEL IAW SRM 53-02-00.SDR AALA201601129003Floor Panel · damagedMID CABIN FLOOR, NEXT TO THE 2R DOOR, IS SOFT IN 3 INCH AREA, APPROX 12 INCHES FROM BASE OF 2R DOOR, PARALLEL TO THRESHOLD OF DOOR. REPLACED HEATED FLOOR PANEL 28DS IAW AMM 20-25-16.
Back to JASC 5321