SDR AALA201509159006Floor Panel · delaminated3S CHECK, AFT GALLEY FLOOR PANEL 261DF, HAS DELAMINATION. REPLACED FLOOR PANEL IAW IRM 9701 REV G.SDR AALA201509039013Floor Panel · delaminated3S CHECK, FLOOR PANEL 221EF HAS DELAMINATION. REPLACED FLOOR PANEL IAW SRM 53-12-00-101 & 53-12-00-201.SDR AALA201509039012Floor Panel · delaminated3S CHECK, FLOOR PANEL 262BG HAS DELAMINATION. REPLACED FLOOR PANEL IAW IRM 9701.SDR AALA201509039011Floor Panel · delaminated3S CHECK, FLOOR PANEL 221PF HAS DELAMINATION. REPLACED FLOOR PANEL IAW SRM 53-12-00-101 & 53-12-00-201.SDR AALA201509019009Floor Panel · delaminated3S CHECK, AFT GALLEY FLOOR PANEL 261BG HAS DELAMINATION. REPLACED FLOOR PANEL IAW IRM 9701 REV G.SDR IPXA2015081592377Floorboard · damagedINSPECTION TYPE:C, MAIN CARGO DECK FLOORBOARD 242XHF DAMAGED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015081592376Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 241XHF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015081592375Floorboard · damagedINSPECTION TYPE:C, MAIN CARGO DECK FLOORBOARD 242XJF DAMAGED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015081592374Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO DECK FLOORBOARD 241XJF DAMAGED. FABRICATED MCD FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015081592373Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO DECK FLOORBOARD 242XCF DAMAGED . FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015081592372Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO DECK FLOORBOARD DAMAGED 241XDF. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015081592370Floor Panel · damagedINSPECTION TYPE:C, MAIN CARGO DECK FLOORBOARD DAMAGED 241XCF. FABRICATED MCD FLOOR PANEL 241XCF, PN 144N5361-54 IAW SREO B757-5320-9692-H FROM A402H-48X144 BATCH NR 2749199.SDR AALA201509159007Floor Panel · delaminated3S CHECK, CABIN FLOOR PANEL 222CF, HAS DELAMINATION. REPLACED PANEL IAW IRM 9701 REV G.SDR AALA201509049004Floor Panel · delaminated3S CHECK, FLOOR PANEL 251WF HAS DELAMINATION. REPLACED FLOOR PANEL IAW IRM 9701 REV G.SDR AALA201509019010Floor Panel · delaminated3S CHECK, PAX CABIN FLOOR PANEL 232 PF DELAMINATED. REPLACED FLOOR PANEL IAW SRM 53-02-00.SDR AALA201508259014Floor Panel · delaminated3S CHECK, PAX CABIN FLOOR PANEL 261PF HAS DELAMINATION. REPLACED FLOOR PANEL 261PF IAW SRM 53-02-00-201.SDR IPXA2015080992176Floor Panel · damagedMCD FLOOR PANEL POS 11-L DAMAGED. FABRICATED A NEW FLOOR PANEL IAW EO B767-5320=9693-H.SDR DALA2015080804882Floor Panel · brokenBROKEN CHANNEL AND FLOOR PANEL. FLOOR PANEL REPAIRED IAW SRM 51-20-0, 51-70-1, PARA 10.SDR DALA2015080704879Floor Panel · corrodedCORROSION ON FLOOR PANEL 160G. FILLER WAS REMOVED FROM PANEL IAW SRM 51-30-2 THEN NEW FILLER AND PANEL WERE FABRICATED IAW DWG 9957828 AND SRM 51-10-2. AFTER THAT, THE FABRICATED PARTS WERE TREATED AND PAINTED IAW SRM 51-10-3, PAR 21 AND 14. FINALLY FLOOR SDR AALA201508249005Floor Panel · delaminated3S CHECK, AFT GALLEY FLOOR PANEL 261AG DELAMINATED. REPLACED FLOOR PANEL IAW IRM 9701 REV G.SDR SWAA2015081342796Splice · corrodedAFT CARGO COMPARTMENT FLOOR PANEL SPLICE CORRODED BETWEEN BS 787 TO 767, BETWEEN STRINGER 24R TO 24L. R & R SPLICE IAW SRM.SDR DALA2015080504843Floor Panel · crackedCRACKED FLOOR PANEL. THE FLOOR PANEL WAS REPAIRED IAW SRM 53-01, FIG 4, 51-10-3, PAR 21 AND 14.SDR IPXA2015082192554Floor Panel · crackedINSPECTION TYPE: 10YR, MAIN CABIN FLOOR PANEL 231KJ IS CRACKED. FABRICATED A NEW FLOOR PANEL IAW EO A300-5320-40552-B.SDR SWAA2015081342795Floor Panel · corrodedAFT CARGO BAY FLOOR PANEL 140CF CORRODED ALONG THE EDGES. R & R FLOORBOARD IAW SRM.SDR DALA2015080104800Floor Panel · crackedCRACKED COCKPIT FLOOR PANEL 120D. A NEW FLOOR PANEL WAS ADJUSTED AND DRILLED IAW SRM 51-10-4.SDR IPXA2015080792126Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XJFS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SR EO B757-5320-9692H.SDR IPXA2015080792125Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XFF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SR EO B757-5320-9692H.SDR IPXA2015072991740Floorboard · delaminatedINSPECTION TYPE:C, MAIN DECK FLOORBOARD 232XJF DELAMINATED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692H.SDR IPXA2015072991739Floorboard · damagedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 231XMF HAS EDGE DAMAGE. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692H.SDR IPXA2015072991738Floorboard · delaminatedINSPECTION TYPE:C, MAIN DECK CARGO FLOORBOARD 232XCF DELAMINATED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692H.SDR IPXA2015072991737Floorboard · damagedINSPECTION TYPE:C, MAIN DECK FLOORBOARD 231XSF HAS EDGE DAMAGE. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692H.SDR IPXA2015072991736Floor Panel · delaminatedINSPECTION TYPE:C, MAIN CARGO FLOOR PANEL 231XCF FOUND DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B7575320-9692H.SDR IPXA2015081292278Floor Panel · crackedINSPECTION TYPE:C9, FOUND CRACK ON CARGO FLOOR PANEL, 232EFF AT BS 511-599, RBL 77 - 88. FABRICATED THE REPLACEMENT FLOOR PANEL IAW EO B767-5320-9693-H.SDR IPXA2015081192271Floor Panel · corrodedINSPECTION TYPE:C, FWD CARGO FLOOR PANEL 121BF HAS CHAFE MARKS/CORROSION ALSO INCLUDING UNDER AND AROUND THE MBA SYSTEM. BLENDED CHAFE MARKS AND CORROSION ON FWD CARGO FLOOR PANEL 121BF, ORG MAT=0.071, MAT REMOVED=0.011 MAT REM=0.0606 USING TR17809. FOUND TOSDR ASOA2015072713537Floor Panel · corrodedLEFT FLOOR SILL PANEL HAS CORROSION AROUND NUTPLATES BETWEEN FS 439 TO FS 461. R & R NUTPLATES BETWEEN FS 439.00 TO FS 461 IAW SRM 51-45-00 AND 51-42-06. COMPLIED WITH EC/TC REO:601R-53-41-666 01 AND REO:601R-53-41-666, REV C.SDR IPXA2015080792127Floor Panel · damagedINSPECTION TYPE: C, ELECTRICAL EQUIPMENT CENTER FLOOR PANEL 119AF HAS TORN FASTENER HOLES. FABRICATED A NEW FLOOR PANEL.SDR IPXA2015073191792Floor Panel · delaminatedINSPECTION TYPE:C, MAIN DECK CARGO FLOOR PANEL 241XEF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015073191791Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK CARGO FLOOR PANEL 242XCF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015073191790Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK CARGO FLOOR PANEL 242XMF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015073191789Floor Panel · delaminatedINSPECTION TYPE: C, MCD FLOOR PANEL 241XFF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015073191788Floor Panel · damagedINSPECTION TYPE :C, MAIN DECK CARGO FLOOR PANEL 241XHF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015073191787Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK CARGO FLOOR PANEL 242XLF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR SWIA201541392Floor Panel · crackedTRU BAY FLOOR CRACKED ON RT SIDE AT FS 193.00. REPAIRED RT TRU BAY FLOOR CRACK IAW STS EA.SDR DALA2015080204785Floor Panel · puncturedA ONE INCH HOLE IN THE AFT CARGO FLOOR FIVE FEET FWD OF OF DOOR. INSTALLED TEMP REPAIR IAW ERA 489384-14MA.SDR AALA201507299004Floorboard · damagedFLIGHT 570, FORWARD GALLEY FLOORBOARD, A BEAM OF COFFEEMAKER, CRACKING & GIVING WAY. REPLACED FLOOR PANEL 221EF IAW AMM 53-12-12.SDR AALA201507289003Floor Panel · delaminatedSY6 CHECK, CABIN FLOOR PANEL 262 BG HAS A 9 INCH BY 6 INCH AREA OF SURFACE DAMAGE. FABRICATED & INSTALLED REPLACEMENT FLOOR PANEL IAW 9701 REV G.SDR AALA201507289002Floor Panel · delaminatedSY6 CHECK, CABIN FLOOR PANEL 261DF HAS A 6 INCH BY 6 INCH AREA OF DELAMINATION AT THE AFT OTBD CORNER. FABRICATED & INSTALLED REPLACEMENT FLOOR PANEL IAW 9701 REV G.SDR AALA201507289001Floor Panel · delaminatedSY6 CHECK, CABIN FLOOR PANEL 261PF HAS A 9 INCH BY 6 INCH AREA OF DELAMINATION AT THE AFT OTBD CORNER. FABRICATED & INSTALLED REPLACEMENT FLOOR PANEL IAW 9701 REV G.SDR AALA201507279002Floor Panel · delaminatedRON, AFT CARGO PANEL 151DF, JUST FWD OF CARGO ENTRY, HAS A DELAMINATED AREA, APPROX 3 FEET BY 5 FEET. R & R FLOOR PANEL IAW AMM 53-42-14-400-001A.SDR AALA201507279001Floor Panel · delaminatedAFT CARGO FLOOR PANEL 151GF, DIRECTLY IN FRONT OF CARGO ENTRY, HAS DELAMINATED AREA, APPROX 15 INCHES BY 22 INCHES. R & R FLOOR PANEL IAW AMM 53-42-14-400-001A.
Back to JASC 5321