JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2014052783065Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL HAS NUMEROUS AREAS OF DAMAGE. FABRICATED AND REPLACED THE FLOOR PANEL IAW EO B767-5320-9693-H.SDR IPXA2014052783064Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL HAS NUMEROUS DAMAGES, FABRICATED AND REPLACED IAW EO B767-5320-9693-H.SDR FDEA201405251188Floorboard · crackedFORWARD CARGO BAY FLOORBOARD 132YF TOP SURFACE PUNCTURED. FABRICATED NEW FLOORBOARD IAW DWG SRZ-25-005. MAJOR REPAIR CAT A REPAIR.SDR USAA2014052700029Floor Panel · delaminatedS2 CHECK DELAMINATION ON FLOOR PANEL 232ZH AT FRAME 35.3, Z-500, -Y509.5. REPLACED FLOOR PANEL 232ZH IAW IRM 9701, REV G.SDR USAA2014052700028Floor Panel · delaminatedS2 CHECK DELAMINATION ON FLOOR PANEL 231ZH AT FRAME 35.3, Z-500, Y509.5. REPLACED FLOOR PANEL 231ZH IAW IRM 9701, REV G.SDR USAA2014052700027Floor Panel · delaminatedS2 CHECK DELAMINATION ON FLOOR PANEL 241EF AT FRAME 39, Z-500, Y=0. REPLACED FLOOR PANEL 241EF IAW IRM 9701, REV G.SDR USAA2014052700026Floor Panel · delaminatedS2 CHECK DELAMINATION ON FLOOR PANEL 231NG AT FRAME 37.5, Z-500, Y=0. REPLACED FLOOR PANEL 231NG IAW IRM 9701, REV G.SDR USAA2014052700025Floor Panel · delaminatedS2 CHECK DELAMINATION ON CABIN FLOOR PANEL 261DF AT FRAME 67, Z-500, Y=0. REPLACED CABIN FLOOR PANEL 261DF IAW IRM 9701, REV G.SDR USAA2014052700024Floor Panel · delaminatedS2 CHECK DELAMINATION ON CABIN FLOOR PANEL 261CG AT FRAME 65, Z-500, Y=0. REPLACED CABIN FLOOR PANEL 261CG IAW IRM 9701, REV G.SDR IPXA2014052783061Floor Panel · damagedMAIN DECK FLOOR PANEL AT FS 1705 RT 3 INCHES INBD OF SIDE WALL HAS A HOLE IN IT. REPAIRED IAW SRM 53-00-50-2R-1.SDR IPXA2014052783059Floor Panel · damagedMAIN DECK FLOOR PANEL DAMAGED RBL 20, BS 1591. REPAIRED SRM 53-00-50-2R-1.SDR SWAA2014061229005Floorboard · delaminatedMAIN CABIN FLOORBOARD 221 KF DELAMINATED. R & R FLOORBOARD IAW SRM.SDR SWAA2014061629050Floorboard · delaminatedMAIN CABIN FLOORBOARD 221DF DELAMINATED. R & R FLOORBOARD IAW SRM.SDR SWAA2014061229004Floorboard · delaminatedMAIN CABIN FLOORBOARD 221 RF DELAMINATED. R & R FLOORBOARD IAW SRM.SDR SWAA2014061229003Floorboard · delaminatedMAIN CABIN FLOORBOARD 222DF DELAMINATED. R & R FLOORBOARD IAW SRM.SDR SWAA2014061229002Floorboard · delaminatedMAIN CABIN FLOORBOARD 222FF DELAMINATED. R & R FLOORBOARD IAW SRM.SDR SWAA2014061229001Floorboard · delaminatedMAIN CABIN FLOORBOARD 221 EF DELAMINATED. R & R FLOORBOARD IAW SRM.SDR SWAA2014061229000Floorboard · delaminatedMAIN CABIN FLOORBOARD 221ALF DELAMINATED. R & R FLOORBOARD IAW SRM.SDR SWAA2014061228999Floorboard · delaminatedMAIN CABIN FLOORBOARD 221CF DELAMINATED. R & R FLOORBOARD IAW SRM.SDR SWAA2014061228998Floorboard · delaminatedMAIN CABIN FLOORBOARD 221 JF DELAMINATED. R & R FLOORBOARD IAW SRM.SDR SWAA2014061228997Floorboard · delaminatedMAIN CABIN FLOORBOARD 221 FF DELAMINATED. R & R FLOORBOARD IAW SRM.SDR SWAA2014061228996Floorboard · delaminatedMAIN CABIN FLOORBOARD 221 BF DELAMINATED. R & R FLOORBOARD IAW SRM.SDR SWAA2014053028549Floor Panel · crackedFLOOR PANEL 242WF CRACKED. R & R PANEL IAW MM.SDR FDEA201405231151Floor Panel · damagedFORWARD CARGO FLOOR PANEL 131QF DAMAGED. FABRICATED REPLACEMENT FLOOR PANEL 131QF ON STAM TRAVELER T14 1066340 IAW DWG SRZ-25-005. CLASSIFIED AS CAT A MAJOR REPAIR.SDR FDEA201405231150Floor Panel · damagedFORWARD CARGO FLOOR PANEL 132ZF DAMAGED. FABRICATED REPLACEMENT FLOOR PANEL ON STAM TRAVELER T14 1066342 IAW DWG SRZ- 25-005. CLASSIFIED AS CAT A MAJOR REPAIR.SDR USAA2014052200014Floor Panel · debondedRON VISIT DIS-BONDING ON FLOOR PANEL BETWEEN FRAME 16 TO FRAME 18, Y=0. REPAIRED FLOOR PANEL BETWEEN FRAME 16 TO FRAME 18, Y=0 IAW AMM 53-12-12-000-001-A.SDR FDEA201405211186Floor Panel · brokenMCD FLOOR PANEL 261VF BROKEN. FABRICATED FLOORBOARD PANEL 261VF IAW STAM TRAVELER T14 1071641 MATERIAL USED A402N 48X144 BATCH 1972508 PO 26684 PART MARK AS FX-R532B387100000 IAW DWG SRZ-25-005. MAJOR REPAIR CAT A REPAIR.SDR DALA14033349008Floor Panel · corrodedAFT CARGO FLOOR PANEL 181LF HAS CORROSION ON UPPER AND LOWER SURFACE. BLENDED & REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-01. FABRICATED NEW FLOOR PANEL IAW ER/A NR 228602-14.SDR DALA14031835806Floor Panel · corrodedDECKPLATE, BS 1680-1720, LT SIDEWALL TO RT SIDEWALL FOUND CORRODED ON UPPER SURFACE. REMOVED CORROSION AND FOUND TO BE WITHIN LIMITS IAW SRM 53-60-51. AREA F FOUND TO BE OUT OF LIMITS IAW SRM. REPAIRED AREA F IAW SRM. ACCOMPLISHED CORROSION PREVENTIVE FINISSDR IPXA201405283084Floor Panel · damagedCP10 INSPECTION, MAIN DECK FLOOR PANEL 242XJF HAS DAMAGED INSERT HOLE AND CORNER EDGE. FABRICATED NEW FLOOR PANEL IAW REO B757-5320-9692-H.SDR IPXA201405283083Floor Panel · damagedCP10 INSPECTION, MAIN DECK FLOOR PANEL 241XDF CORNER EDGES DAMAGED. FABRICATED NEW FLOOR PANEL IAW REO B757-5320-9692-H.SDR IPXA201405283082Floor Panel · damagedCP10 INSPECTION, MAIN DECK FLOOR PANEL 242XFF CORNER EDGE DAMAGED. FABRICATED NEW FLOOR PANEL IAW REO B757-53 20-9692-H.SDR IPXA201405283081Floor Panel · damagedCP10 INSPECTION, MAIN DECK FLOOR PANEL 241XJF CORNER EDGE DAMAGED. FABRICATED NEW FLOOR PANEL IAW SAEO B757-5320-9692-H.SDR IPXA201405283080Floor Panel · crackedCP10 INSPECTION, MAIN DECK FLOOR PANEL 241XCF DAMAGED CRACKED. FABRICATED NEW FLOOR PANEL IAW SREO B757-53 20-9692-H.SDR IPXA201405283079Floor Panel · damagedCP10 INSPECTION, MAIN DECK FLOOR PANEL 241XEF DAMAGED ON EDGES. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2014052883078Floor Panel · damagedCP10 INSPECTION, MAIN DECK FLOOR PANEL 242XDF CORNER EDGE DAMAGED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2014060983234Floor Panel · corroded4C INSPECTION, RIGID CARGO BARRIER FLOOR PANEL HAS CORROSION AT BS 475 X-47.50 REPAIRED FLOOR PANEL IAW EA 011-5310-01-A5383 AND EO 5310-54594-A.SDR SWIA201437906Floor Panel · crackedCRACK ON TRU FLOOR UNDER BRAKE ACCUMULATOR GAUGES, C-CHECK, REPAIRED FLOOR IAW REO.SDR FDEA201405171058Floor Panel · delaminatedMAIN DECK CARGO FLOOR PANEL 273HF FOUND DELAMINATED. FABRICATED IAW DRAWING SRZ 25-005 REVISION K. REMOVED AND REPLACED IAW AMM 53-21-04-4 REVISION 79. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100 REVISION 121.SDR FDEA201405171057Floor Panel · delaminatedMAIN DECK CARGO FLOOR PANEL 293DF FOUND DELAMINATED. FABRICATED IAW DRAWING SRZ 25-005 REVISION K. REMOVED AND REPLACED IAW AMM 53-21-04-4 REVISION 79. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100 REVISION 121.SDR FDEA201405171056Floor Panel · delaminatedMAIN DECK CARGO FLOOR PANEL 233DF FOUND DELAMINATED. FABRICATED IAW DRAWING SRZ 25-005 REVISION K. REMOVED AND REPLACED IAW AMM 53-21-04-4 REVISION 79. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100 REVISION 121.SDR SWAA2014061829169Floor Panel · corrodedFLOOR PANEL 120AF CORRODED ON FWD UPPER SURFACE. R & R FLOOR PANEL IAW SRM.SDR SWIA201437833Floor Panel · corrodedLEFT PRESSURE FLOOR DOUBLER BS 409+128 - 473.15 HAS FOUR AREAS OF CORROSION. C-CHECK, REMOVED CORROSION IAW REO.SDR SWIA201437832Floor Panel · corrodedLEFT PRESSURE FLOOR DOUBLER BS 473.15 - 513 HAS THREE AREAS OF CORROSION. C-CHECK, REMOVED CORROSION IAW REO.SDR SWIA201437831Floor Panel · corrodedLEFT PRESSURE FLOOR DOUBLER BS 513-559 HAS FIVE AREAS OF CORROSION. C-CHECK, REMOVED CORROSION IAW REO.SDR SWIA201437826Floor Panel · corrodedRT PRESSURE FLOOR DOUBLER BS 409+128-473.15 HAS FOUR AREAS OF CORROSION. C-CHECK REMOVED CORROSION IAW REO.SDR SWIA201437825Floor Panel · corrodedRIGHT PRESSURE FLOOR DOUBLER BS 473.15-513 HAS THREE AREAS OF CORROSION. C-CHECK REMOVED CORROSION IAW REO.SDR SWIA201437824Floor Panel · corrodedRIGHT PRESSURE FLOOR DOUBLER BS 513-559 HAS FOUR AREAS OF CORROSION. C-CHECK, REMOVED CORROSION IAW REO.SDR IPXA2014052883085Floorboard · delaminatedMAIN CABIN FLOORBOARD 251MG IS DELAMINATED ON LOWER SURFACE. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR FDEA201405151166Floor Panel · damagedMCD FLOOR PANEL 232CF AFT EDGE BROKEN. FABRICATED NEW FLOOR PANEL 232CF ON TRAVELER T14 1069960 IAW DWG SRZ-25-005. CLASSIFIED AS MAJOR CAT A REPAIR.
Back to JASC 5321